]> sigrok.org Git - libsigrok.git/blobdiff - hardware/fluke-dmm/api.c
output/csv: use intermediate time_t var, silence compiler warning
[libsigrok.git] / hardware / fluke-dmm / api.c
diff --git a/hardware/fluke-dmm/api.c b/hardware/fluke-dmm/api.c
deleted file mode 100644 (file)
index bf00b73..0000000
+++ /dev/null
@@ -1,432 +0,0 @@
-/*
- * This file is part of the sigrok project.
- *
- * Copyright (C) 2012 Bert Vermeulen <bert@biot.com>
- *
- * This program is free software: you can redistribute it and/or modify
- * it under the terms of the GNU General Public License as published by
- * the Free Software Foundation, either version 3 of the License, or
- * (at your option) any later version.
- *
- * This program is distributed in the hope that it will be useful,
- * but WITHOUT ANY WARRANTY; without even the implied warranty of
- * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
- * GNU General Public License for more details.
- *
- * You should have received a copy of the GNU General Public License
- * along with this program.  If not, see <http://www.gnu.org/licenses/>.
- */
-
-#include <glib.h>
-#include <sys/types.h>
-#include <sys/stat.h>
-#include <fcntl.h>
-#include <string.h>
-#include <errno.h>
-#include "libsigrok.h"
-#include "libsigrok-internal.h"
-#include "fluke-dmm.h"
-
-static const int hwopts[] = {
-       SR_CONF_CONN,
-       SR_CONF_SERIALCOMM,
-       0,
-};
-
-static const int hwcaps[] = {
-       SR_CONF_MULTIMETER,
-       SR_CONF_LIMIT_SAMPLES,
-       SR_CONF_LIMIT_MSEC,
-       SR_CONF_CONTINUOUS,
-       0,
-};
-
-SR_PRIV struct sr_dev_driver flukedmm_driver_info;
-static struct sr_dev_driver *di = &flukedmm_driver_info;
-
-static char *scan_conn[] = {
-       /* 287/289 */
-       "115200/8n1",
-       /* 187/189 */
-       "9600/8n1",
-       /* Scopemeter 190 series */
-       "1200/8n1",
-       NULL
-};
-
-static const struct flukedmm_profile supported_flukedmm[] = {
-       { FLUKE_187, "187", 100, 1000 },
-       { FLUKE_287, "287", 100, 1000 },
-       { FLUKE_190, "199B", 1000, 3500 },
-};
-
-
-/* Properly close and free all devices. */
-static int clear_instances(void)
-{
-       struct sr_dev_inst *sdi;
-       struct drv_context *drvc;
-       struct dev_context *devc;
-       GSList *l;
-
-       if (!(drvc = di->priv))
-               return SR_OK;
-
-       drvc = di->priv;
-       for (l = drvc->instances; l; l = l->next) {
-               if (!(sdi = l->data))
-                       continue;
-               if (!(devc = sdi->priv))
-                       continue;
-               sr_serial_dev_inst_free(devc->serial);
-               sr_dev_inst_free(sdi);
-       }
-       g_slist_free(drvc->instances);
-       drvc->instances = NULL;
-
-       return SR_OK;
-}
-
-static int hw_init(struct sr_context *sr_ctx)
-{
-       struct drv_context *drvc;
-
-       if (!(drvc = g_try_malloc0(sizeof(struct drv_context)))) {
-               sr_err("Driver context malloc failed.");
-               return SR_ERR_MALLOC;
-       }
-
-       drvc->sr_ctx = sr_ctx;
-       di->priv = drvc;
-
-       return SR_OK;
-}
-
-static GSList *fluke_scan(const char *conn, const char *serialcomm)
-{
-       struct sr_dev_inst *sdi;
-       struct drv_context *drvc;
-       struct dev_context *devc;
-       struct sr_probe *probe;
-       struct sr_serial_dev_inst *serial;
-       GSList *devices;
-       int retry, len, i, s;
-       char buf[128], *b, **tokens;
-
-       if (!(serial = sr_serial_dev_inst_new(conn, serialcomm)))
-               return NULL;
-
-       if (serial_open(serial, SERIAL_RDWR | SERIAL_NONBLOCK) != SR_OK)
-               return NULL;
-
-       drvc = di->priv;
-       b = buf;
-       retry = 0;
-       devices = NULL;
-       /* We'll try the discovery sequence three times in case the device
-        * is not in an idle state when we send ID. */
-       while (!devices && retry < 3) {
-               retry++;
-               serial_flush(serial);
-               if (serial_write(serial, "ID\r", 3) == -1) {
-                       sr_err("Unable to send ID string: %s.",
-                              strerror(errno));
-                       continue;
-               }
-
-               /* Response is first a CMD_ACK byte (ASCII '0' for OK,
-                * or '1' to signify an error. */
-               len = 128;
-               serial_readline(serial, &b, &len, 150);
-               if (len != 1)
-                       continue;
-               if (buf[0] != '0')
-                       continue;
-
-               /* If CMD_ACK was OK, ID string follows. */
-               len = 128;
-               serial_readline(serial, &b, &len, 850);
-               if (len < 10)
-                       continue;
-               if (strcspn(buf, ",") < 15)
-                       /* Looks like it's comma-separated. */
-                       tokens = g_strsplit(buf, ",", 3);
-               else
-                       /* Fluke 199B, at least, uses semicolon. */
-                       tokens = g_strsplit(buf, ";", 3);
-               if (!strncmp("FLUKE", tokens[0], 5)
-                               && tokens[1] && tokens[2]) {
-                       for (i = 0; supported_flukedmm[i].model; i++) {
-                               if (strcmp(supported_flukedmm[i].modelname, tokens[0] + 6))
-                                       continue;
-                               /* Skip leading spaces in version number. */
-                               for (s = 0; tokens[1][s] == ' '; s++);
-                               if (!(sdi = sr_dev_inst_new(0, SR_ST_INACTIVE, "Fluke",
-                                               tokens[0] + 6, tokens[1] + s)))
-                                       return NULL;
-                               if (!(devc = g_try_malloc0(sizeof(struct dev_context)))) {
-                                       sr_err("Device context malloc failed.");
-                                       return NULL;
-                               }
-                               devc->profile = &supported_flukedmm[i];
-                               devc->serial = serial;
-                               sdi->priv = devc;
-                               sdi->driver = di;
-                               if (!(probe = sr_probe_new(0, SR_PROBE_ANALOG, TRUE, "P1")))
-                                       return NULL;
-                               sdi->probes = g_slist_append(sdi->probes, probe);
-                               drvc->instances = g_slist_append(drvc->instances, sdi);
-                               devices = g_slist_append(devices, sdi);
-                               break;
-                       }
-               }
-               g_strfreev(tokens);
-               if (devices)
-                       /* Found one. */
-                       break;
-       }
-       serial_close(serial);
-       if (!devices)
-               sr_serial_dev_inst_free(serial);
-
-       return devices;
-}
-
-static GSList *hw_scan(GSList *options)
-{
-       struct sr_config *src;
-       GSList *l, *devices;
-       int i;
-       const char *conn, *serialcomm;
-
-       conn = serialcomm = NULL;
-       for (l = options; l; l = l->next) {
-               src = l->data;
-               switch (src->key) {
-               case SR_CONF_CONN:
-                       conn = src->value;
-                       break;
-               case SR_CONF_SERIALCOMM:
-                       serialcomm = src->value;
-                       break;
-               }
-       }
-       if (!conn)
-               return NULL;
-
-       if (serialcomm) {
-               /* Use the provided comm specs. */
-               devices = fluke_scan(conn, serialcomm);
-       } else {
-               for (i = 0; scan_conn[i]; i++) {
-                       if ((devices = fluke_scan(conn, scan_conn[i])))
-                               break;
-                       /* The Scopemeter 199B, at least, requires this
-                        * after all the 115k/9.6k confusion. */
-                       g_usleep(5000);
-               }
-       }
-
-       return devices;
-}
-
-static GSList *hw_dev_list(void)
-{
-       struct drv_context *drvc;
-
-       drvc = di->priv;
-
-       return drvc->instances;
-}
-
-static int hw_dev_open(struct sr_dev_inst *sdi)
-{
-       struct dev_context *devc;
-
-       if (!(devc = sdi->priv)) {
-               sr_err("sdi->priv was NULL.");
-               return SR_ERR_BUG;
-       }
-
-       if (serial_open(devc->serial, SERIAL_RDWR | SERIAL_NONBLOCK) != SR_OK)
-               return SR_ERR;
-
-       sdi->status = SR_ST_ACTIVE;
-
-       return SR_OK;
-}
-
-static int hw_dev_close(struct sr_dev_inst *sdi)
-{
-       struct dev_context *devc;
-
-       if (!(devc = sdi->priv)) {
-               sr_err("sdi->priv was NULL.");
-               return SR_ERR_BUG;
-       }
-
-       if (devc->serial && devc->serial->fd != -1) {
-               serial_close(devc->serial);
-               sdi->status = SR_ST_INACTIVE;
-       }
-
-       return SR_OK;
-}
-
-static int hw_cleanup(void)
-{
-
-       clear_instances();
-
-       return SR_OK;
-}
-
-static int config_get(int id, const void **data, const struct sr_dev_inst *sdi)
-{
-       (void)sdi;
-
-       switch (id) {
-       case SR_DI_HWOPTS:
-               *data = hwopts;
-               break;
-       case SR_DI_HWCAPS:
-               *data = hwcaps;
-               break;
-       default:
-               return SR_ERR_ARG;
-       }
-
-       return SR_OK;
-}
-
-static int config_set(int id, const void *value, const struct sr_dev_inst *sdi)
-{
-       struct dev_context *devc;
-
-       if (sdi->status != SR_ST_ACTIVE)
-               return SR_ERR;
-
-       if (!(devc = sdi->priv)) {
-               sr_err("sdi->priv was NULL.");
-               return SR_ERR_BUG;
-       }
-
-       switch (id) {
-       case SR_CONF_LIMIT_MSEC:
-               /* TODO: not yet implemented */
-               if (*(const uint64_t *)value == 0) {
-                       sr_err("LIMIT_MSEC can't be 0.");
-                       return SR_ERR;
-               }
-               devc->limit_msec = *(const uint64_t *)value;
-               sr_dbg("Setting time limit to %" PRIu64 "ms.",
-                      devc->limit_msec);
-               break;
-       case SR_CONF_LIMIT_SAMPLES:
-               devc->limit_samples = *(const uint64_t *)value;
-               sr_dbg("Setting sample limit to %" PRIu64 ".",
-                      devc->limit_samples);
-               break;
-       default:
-               sr_err("Unknown capability: %d.", id);
-               return SR_ERR;
-               break;
-       }
-
-       return SR_OK;
-}
-
-static int config_list(int key, const void **data, const struct sr_dev_inst *sdi)
-{
-
-       (void)sdi;
-
-       switch (key) {
-       default:
-               return SR_ERR_ARG;
-       }
-
-       return SR_OK;
-}
-
-static int hw_dev_acquisition_start(const struct sr_dev_inst *sdi,
-               void *cb_data)
-{
-       struct sr_datafeed_packet packet;
-       struct sr_datafeed_header header;
-       struct dev_context *devc;
-
-       if (!(devc = sdi->priv)) {
-               sr_err("sdi->priv was NULL.");
-               return SR_ERR_BUG;
-       }
-
-       sr_dbg("Starting acquisition.");
-
-       devc->cb_data = cb_data;
-
-       /* Send header packet to the session bus. */
-       sr_dbg("Sending SR_DF_HEADER.");
-       packet.type = SR_DF_HEADER;
-       packet.payload = (uint8_t *)&header;
-       header.feed_version = 1;
-       gettimeofday(&header.starttime, NULL);
-       sr_session_send(devc->cb_data, &packet);
-
-       /* Poll every 100ms, or whenever some data comes in. */
-       sr_source_add(devc->serial->fd, G_IO_IN, 50, fluke_receive_data, (void *)sdi);
-
-       if (serial_write(devc->serial, "QM\r", 3) == -1) {
-               sr_err("Unable to send QM: %s.", strerror(errno));
-               return SR_ERR;
-       }
-       devc->cmd_sent_at = g_get_monotonic_time() / 1000;
-       devc->expect_response = TRUE;
-
-       return SR_OK;
-}
-
-static int hw_dev_acquisition_stop(struct sr_dev_inst *sdi, void *cb_data)
-{
-       struct sr_datafeed_packet packet;
-       struct dev_context *devc;
-
-       if (sdi->status != SR_ST_ACTIVE)
-               return SR_ERR;
-
-       if (!(devc = sdi->priv)) {
-               sr_err("sdi->priv was NULL.");
-               return SR_ERR_BUG;
-       }
-
-       sr_dbg("Stopping acquisition.");
-
-       sr_source_remove(devc->serial->fd);
-       hw_dev_close((struct sr_dev_inst *)sdi);
-
-       /* Send end packet to the session bus. */
-       sr_dbg("Sending SR_DF_END.");
-       packet.type = SR_DF_END;
-       sr_session_send(cb_data, &packet);
-
-       return SR_OK;
-}
-
-SR_PRIV struct sr_dev_driver flukedmm_driver_info = {
-       .name = "fluke-dmm",
-       .longname = "Fluke 18x/28x series DMMs",
-       .api_version = 1,
-       .init = hw_init,
-       .cleanup = hw_cleanup,
-       .scan = hw_scan,
-       .dev_list = hw_dev_list,
-       .dev_clear = clear_instances,
-       .config_get = config_get,
-       .config_set = config_set,
-       .config_list = config_list,
-       .dev_open = hw_dev_open,
-       .dev_close = hw_dev_close,
-       .dev_acquisition_start = hw_dev_acquisition_start,
-       .dev_acquisition_stop = hw_dev_acquisition_stop,
-       .priv = NULL,
-};