]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
doc: update README, optional conn= specs for UNI-T meters
[libsigrok.git] / README.devices
index f5c8e976d148233bcde49cffd0d5755579cbed90..9ab254a13b00c8ff44beba2f2bbcd1daf115e45a 100644 (file)
@@ -115,6 +115,7 @@ The following drivers/devices do not need any firmware upload:
  - scpi-pps
  - serial-dmm (including all subdrivers)
  - serial-lcr (including all subdrivers)
+ - siglent-sds
  - teleinfo
  - testo
  - tondaj-sl-814
@@ -129,7 +130,14 @@ Specifying serial ports
 -----------------------
 
 Many devices supported by libsigrok use serial port based cables (real RS232
-or USB-to-serial ones) to connect to a PC.
+or USB-to-serial ones, CDC class) to connect to a PC. These serial cables are
+supported by the libserialport library. Some vendors prefer to use HID chips
+instead of CDC chips in their serial cables. These cables can get supported
+by means of the hidapi library. Note that each chip type requires specific
+support in the libsigrok library. Bluetooth connected devices may be supported
+as well when they communicate by means of RFCOMM channels, or one of the
+implemented BLE notification/indication approaches, and one of the Bluetooth
+supporting platforms is used.
 
 For all these devices, you need to specify the serial port they are connected
 to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan
@@ -138,9 +146,12 @@ for such devices without specifying a serial port.
 Example:
 
  $ sigrok-cli --driver <somedriver>:conn=/dev/ttyUSB0 ...
+ $ sigrok-cli --driver <somedriver>:conn=hid/cp2110 ...
+ $ sigrok-cli --driver <somedriver>:conn=bt/rfcomm/01-23-45-67-89-ab ...
 
 The following drivers/devices require a serial port specification. Some of
-the drivers implement a default for the connection.
+the drivers implement a default for the connection. Some of the drivers
+can auto-detect USB connected devices.
 
  - agilent-dmm
  - appa-55ii
@@ -162,6 +173,8 @@ the drivers implement a default for the connection.
  - serial-lcr (including all subdrivers)
  - teleinfo
  - tondaj-sl-814
+ - uni-t-dmm (all -ser subdrivers)
+ - uni-t-ut32x
 
 The following drivers/devices do not require a serial port specification:
 
@@ -179,8 +192,7 @@ The following drivers/devices do not require a serial port specification:
  - rigol-ds (USBTMC or TCP)
  - saleae-logic16
  - sysclk-lwla
- - uni-t-dmm (including all subdrivers)
- - uni-t-ut32x
+ - uni-t-dmm (all non -ser subdrivers)
  - victor-dmm
  - yokogawa-dlm (USBTMC or TCP)
  - zeroplus-logic-cube
@@ -192,11 +204,14 @@ or VXI communication parameters. See these examples:
  $ sigrok-cli --driver <somedriver>:conn=<vid>.<pid> ...
  $ sigrok-cli --driver <somedriver>:conn=tcp-raw/<ipaddr>/<port> ...
  $ sigrok-cli --driver <somedriver>:conn=vxi/<ipaddr> ...
+ $ sigrok-cli --driver <somedriver>:conn=usbtmc/<bus>.<addr> ...
 
 The following drivers/devices accept network communication parameters:
 
  - hameg-hmo
  - rigol-ds
+ - scpi-dmm
+ - siglent-sds
  - yokogawa-dlm
 
 
@@ -282,9 +297,11 @@ UNI-T DMM (and rebranded models) cables
 UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can
 ship with different PC connectivity cables:
 
+ - UT-D02 (RS232 cable)
  - UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490)
  - UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008)
- - UT-D02 (RS232 cable)
+ - UT-D07 (Bluetooth adapter, ISSC BL79 BLETR chip)
+ - UT-D09 (USB/HID cable with SiL CP2110 chip, USB VID/PID 10c4:ea80)
 
 The above cables are all physically compatible (same IR connector shape)
 with all/most currently known UNI-T multimeters. For example, you can
@@ -359,7 +376,9 @@ a short list for convenience:
 
  - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
    interface panel on top.
+ - Brymen BM257s: Press HOLD during power-on.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
+ - EEVBlog 121GW: Hold "1ms PEAK" until the "BT" indicator is shown.
  - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
    - Power on the device with the "DATA" button pressed.
    - Metrahit 2x devices must be configured for the respective interface type.