+ * Sigma doesn't support limiting the number of samples, so we have to
+ * translate the number and the samplerate to an elapsed time.
+ *
+ * In addition we need to ensure that the last data cluster has passed
+ * the hardware pipeline, and became available to the PC side. With RLE
+ * compression up to 327ms could pass before another cluster accumulates
+ * at 200kHz samplerate when input pins don't change.
+ */
+SR_PRIV uint64_t sigma_limit_samples_to_msec(const struct dev_context *devc,
+ uint64_t limit_samples)
+{
+ uint64_t limit_msec;
+ uint64_t worst_cluster_time_ms;
+
+ limit_msec = limit_samples * 1000 / devc->cur_samplerate;
+ worst_cluster_time_ms = 65536 * 1000 / devc->cur_samplerate;
+ /*
+ * One cluster time is not enough to flush pipeline when sampling
+ * grounded pins with 1 sample limit at 200kHz. Hence the 2* fix.
+ */
+ return limit_msec + 2 * worst_cluster_time_ms;
+}
+