1 .TH SIGROK\-CLI 1 "May 29, 2012"
3 sigrok\-cli \- Command-line client for the sigrok software
5 .B sigrok\-cli [OPTIONS] [COMMAND]
7 \fBsigrok\-cli\fP is a cross-platform command line utility for the \fBsigrok\fP software.
9 The command-line frontend for sigrok cannot display graphical output, but is
10 still sufficient to run through the whole process of hardware initialization,
11 acquisition, protocol decoding and saving the session.
13 It is useful for running on remote or embedded systems, netbooks, PDAs,
14 and for various other use-cases. It can display samples on standard output or
15 save them in various file formats.
19 Show a help text and exit.
24 version, and information about supported hardware drivers, input file
25 formats, output file formats, and protocol decoders.
27 \fB\-\-driver\fP <drivername>
28 A driver must always be selected. Use the \fB-V\fP option to get a list of available drivers. Drivers can take options, in the form \fBkey=value\fP separated by colons.
30 Drivers communicating with hardware via a serial port always need the port specified as the \fBconn\fP option. For example, to use the Openbench Logic Sniffer:
32 .RB " $ " "sigrok\-cli \-\-driver=ols:conn=/dev/ttyACM0"
34 Some USB devices don't use a unique VendorID/ProductID combination, and thus need that specified as well. This also uses the \fBconn\fP option, using either \fBVendorID.ProductID\fP or \fBbus.address\fP:
36 .RB " $ " "sigrok\-cli \-\-driver=nexus-osciprime:conn=04b4.8613"
38 .BR "\-d, \-\-device " <device>
39 A colon-separated list of device options, where each option takes the form
41 For example, to set the samplerate on a device supported by the fx2lafw
42 driver, you might specify
44 .RB " $ " "sigrok\-cli \-\-driver=fx2lafw \-\-device samplerate=1m"
46 Samplerate is an option common to most logic analyzers. The argument specifies
47 the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
48 The following are all equivalent:
50 .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-device samplerate=1000000"
52 .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-device samplerate=1m"
54 .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-device \(dqsamplerate=1 MHz\(dq"
56 .BR "\-i, \-\-input\-file " <filename>
57 Load input from a file instead of a hardware device. If the
59 option is not supplied, sigrok-cli attempts to autodetect the file format of
62 .BR "\-I, \-\-input\-format " <format>
63 When loading an input file, assume it's in the specified format. If this
64 option is not supplied (in addition to
65 .BR \-\-input\-file ),
66 sigrok-cli attempts to autodetect the file format of the input file. Use the
68 option to see a list of available input formats. The format name may
69 optionally be followed by a colon-separated list of options, where each
73 .BR "\-o, \-\-output\-file " <filename>
74 Save output to a file instead of writing it to stdout. The default format
75 used when saving is the sigrok session file format. This can be changed with
80 .BR "\-O, \-\-output\-format " <formatname>
81 Set the output format to use. Use the
83 option to see a list of available output formats. The format name may
84 optionally be followed by a colon-separated list of options, where each
88 Supported formats currently include
96 .BR chronovu-la8 ", and"
103 formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus
105 will display 128 bits per line, in hexadecimal:
107 1:ffff ffff ffff ffff ffff ffff ffff ffff
108 2:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
110 The lines always start with the probe number (or name, if defined), followed by a colon. If no format is specified, it defaults to
114 1:11111111 11111111 11111111 11111111 [...]
115 2:11111111 00000000 11111111 00000000 [...]
117 .BR "\-p, \-\-probes " <probelist>
118 A comma-separated list of probes to be used in the session.
120 Note that sigrok always names the probes according to how they're shown on the enclosure of the hardware. If your logic analyzer numbers the probes 0-15, that's how you must specify them with this option. An oscilloscope's probes would generally be referred to as "CH1", "CH2", and so on. Use the \fB\-\-show\fP option to see a list of probe names for your device.
122 The default is to use all the probes available on a device. You can name
125 A range of probes can also be given, in the form
131 .B "sigrok\-cli \-\-driver fx2lafw \-\-samples 100 \-\-probes 1=CLK,2\-4,7"
133 CLK:11111111 11111111 11111111 11111111 [...]
134 2:11111111 11111111 11111111 11111111 [...]
135 3:11111111 11111111 11111111 11111111 [...]
136 4:11111111 11111111 11111111 11111111 [...]
137 7:11111111 11111111 11111111 11111111 [...]
139 The comma-separated list is processed from left to right, i.e. items farther
140 to the right override previous items. For example
142 will set the name of probe 1 to
147 will only select probes 5 and 6, and set their names to MISO and MOSI, the
149 .B "5=MOSI,6=MISO,1\-8"
150 will select probes 1\-8 (including 5 and 6, of course), but the names specified
151 for probes 5 and 6 will be reset to the defaults by the
155 .BR "\-t, \-\-triggers " <triggerlist>
156 A comma-separated list of triggers to use, of the form
157 .BR "<probe>=<trigger>" .
158 You can use the name or number of the probe, and the trigger itself is a
159 series of characters:
162 A low or high value on the pin.
165 A rising or falling value on the pin. An
167 effectively corresponds to
171 Any kind of change on a pin (either a rising or a falling edge).
173 Not every device supports all of these trigger types. Use the \fB\-\-show\fP command to see which triggers your device supports.
175 .BR "\-w, \-\-wait-trigger"
176 Don't output any sample data (even if it's actually received from the hardware) before the trigger condition is met. In other words, do not output any pre-trigger data. This option is useful if you don't care about the data that came before the trigger (but the hardware delivers this data to sigrok nonetheless).
178 .BR "\-a, \-\-protocol\-decoders " <list>
179 This option allows the user to specify a comma-separated list of protocol
180 decoders to be used in this session. The decoders are specified by their
188 .B "sigrok\-cli \-i <file.sr> \-a i2c"
190 Each protocol decoder can optionally be followed by a colon-separated list
191 of options, where each option takes the form
197 .B "sigrok\-cli \-i <file.sr> \-a uart:baudrate=115200:parity=odd"
199 The list of supported options depends entirely on the protocol decoder. Every
200 protocol decoder has different options it supports.
202 Any "options" specified for a protocol decoder which are not actually
203 supported options, will be interpreted as being probe name/number assignments.
208 .B "sigrok\-cli \-i <file.sr>"
210 .B " \-a spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0"
214 is an option supported by the
216 protocol decoder. Additionally, the user tells sigrok to decode the SPI
217 protocol using probe 1 as MISO signal for SPI, probe 5 as MOSI, probe 3
218 as SCK, and probe 0 as CS# signal.
220 .BR "\-s, \-\-protocol\-decoder\-stack " <stack>
221 This option allows the user to specify a protocol decoder stack, i.e.
222 the way in which one protocol decoder's output gets piped into another
223 protocol decoder. If not specified, the stack will be set up in the same
224 order in which the protocol decoders were given with the
225 .B \-\-protocol-decoders
228 The decoders are specified by their ID, as shown in the
230 output. In addition to the
232 option, all protocol decoders that are used in a stack, must also be specified
233 (together with their options, if any) using the
240 .B "sigrok\-cli \-i <file.sr> \-a i2c:sda=4:scl=7,rtc8564"
242 .B " \-s i2c,rtc8564"
246 option specifies that the output of the
249 .BR rtc8564 " decoder,"
251 .BR rtc8564 " decoder"
252 is stacked on top of the
255 The respective protocol decoder options and probe name/number assignments
256 must be given using the
258 option (you cannot specify them in the
262 .BR "\-A, \-\-protocol\-decoder\-annotations " <annotations>
263 By default, only the stack's topmost protocol decoder's annotation output is
264 shown. With this option another decoder's annotation can be selected for
265 display, by specifying its ID:
268 .B "sigrok\-cli \-i <file.sr> \-a i2c,i2cfilter,edid -A i2c"
270 If a protocol decoder has multiple annotation formats, you can also specify
271 which of them to show by specifying its short description like this:
274 .B "sigrok\-cli \-i <file.sr> \-a i2c,i2cfilter,edid"
278 You can also select multiple protocol decoders, with an optional selected
279 annotation format each, by separating them with commas:
282 .B "sigrok\-cli \-i <file.sr> \-a i2c,i2cfilter,edid"
284 .B " \-A i2c=rawhex,edid"
286 .BR "\-l, \-\-loglevel " <level>
287 Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP doesn't support setting the two loglevels independently. The higher the
288 number, the more debug output will be printed. Valid loglevels are:
296 \fB3\fP Informational
304 Show information about the selected option. For example, to see options for a connected fx2lafw device:
307 .B "sigrok\-cli \-\-driver fx2lafw \-\-show
309 In order to properly get device options for your hardware, some drivers might need a serial port specified:
312 .B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show
314 To view the documentation for a protocol decoder:
317 .B "sigrok\-cli \-\-protocol-decoders i2c \-\-show
319 .B "\-D, \-\-list\-devices"
320 List all devices found on the system. This actively scans for devices that can be detected automatically.
325 milliseconds, then quit. You can optionally follow the number by
327 to state the number of seconds to sample instead. For example,
329 will sample for two seconds.
331 .BR "\-\-samples " <numsamples>
337 Sample continuously until stopped. Not all devices support this.
339 In order to get exactly 100 samples from the connected fx2lafw-supported logic analyzer hardware, run the following command:
341 .B " sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
343 If you want to sample data for 3 seconds, use:
345 .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3000"
347 Alternatively, you can also use:
349 .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
351 To capture data from the first 4 probes using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
352 0:high, 1:rising, 2:low, 3:high, use:
355 \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-device samplerate=10m \\
356 \fB\-\-output\-format bits \-\-probes 0\-3 \-\-time 100 \\
357 \fB\-\-wait\-trigger \-\-triggers 0=1,1=r,2=0,3=1
361 exits with 0 on success, 1 on most failures.
366 Please report any bugs on the sigrok\-devel mailing list
367 .RB "(" sigrok\-devel@lists.souceforge.net ")."
370 is covered by the GNU General Public License (GPL). Some portions are
371 licensed under the "GPL v2 or later", some under "GPL v3 or later".
373 Please see the individual source code files.
375 This manual page was written by Uwe Hermann <uwe@hermann\-uwe.de>.