Commit | Line | Data |
---|---|---|
1 | ------------------------------------------------------------------------------- | |
2 | README.devices | |
3 | ------------------------------------------------------------------------------- | |
4 | ||
5 | This README contains various notes for users of libsigrok (or frontends | |
6 | that are based on libsigrok) about device- and/or driver-specific issues. | |
7 | ||
8 | ||
9 | Firmware | |
10 | -------- | |
11 | ||
12 | Some devices supported by libsigrok need a firmware to be uploaded every time | |
13 | the device is connected to the PC (usually via USB), before it can be used. | |
14 | ||
15 | The default location where libsigrok expects the firmware files is: | |
16 | ||
17 | $prefix/share/sigrok-firmware | |
18 | ||
19 | ($prefix is usually /usr/local or /usr, depending on your ./configure options) | |
20 | ||
21 | For further information see the section below and also: | |
22 | ||
23 | http://sigrok.org/wiki/Firmware | |
24 | ||
25 | ||
26 | Per-driver firmware requirements | |
27 | -------------------------------- | |
28 | ||
29 | The following drivers/devices require a firmware upload upon connection: | |
30 | ||
31 | - asix-sigma: The ASIX SIGMA and SIGMA2 require various firmware files, | |
32 | depending on the settings used. These files are available from our | |
33 | 'sigrok-firmware' repository/project under a license which allows us | |
34 | to redistribute them. | |
35 | ||
36 | - fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the | |
37 | firmware files from the 'sigrok-firmware-fx2lafw' repository/project. | |
38 | The firmware is written from scratch and licensed under the GNU GPLv2+. | |
39 | ||
40 | - hantek-dso: The Hantek DSO-2090 (and other supported models of the same | |
41 | series of Hantek PC oscilloscopes) need firmware files. | |
42 | These can be extracted from the vendor's Windows drivers using a tool | |
43 | from our 'sigrok-util' repository/project. | |
44 | ||
45 | - saleae-logic16: The Saleae Logic16 needs a firmware file for the | |
46 | Cypress FX2 chip in the device, as well as two FPGA bitstream files. | |
47 | These can be extracted from the vendor's Linux application using a tool | |
48 | from our 'sigrok-util' repository/project. | |
49 | ||
50 | - sysclk-lwla: The Sysclk LWLA1034 requires various bitstream files. | |
51 | These files are available from our 'sigrok-firmware' repository/project | |
52 | under a license which allows us to redistribute them. | |
53 | ||
54 | The following drivers/devices do not need any firmware upload: | |
55 | ||
56 | - agilent-dmm | |
57 | - appa-55ii | |
58 | - atten-pps3xxx | |
59 | - brymen-bm86x | |
60 | - brymen-dmm | |
61 | - cem-dt-885x | |
62 | - center-3xx (including all subdrivers) | |
63 | - chronovu-la | |
64 | - colead-slm | |
65 | - conrad-digi-35-cpu | |
66 | - demo | |
67 | - fluke-dmm | |
68 | - gmc-mh-1x-2x (including all subdrivers) | |
69 | - hameg-hmo | |
70 | - ikalogic-scanalogic2 | |
71 | - ikalogic-scanaplus | |
72 | - kecheng-kc-330b | |
73 | - lascar-el-usb | |
74 | - link-mso19 | |
75 | - mic-985xx (including all subdrivers) | |
76 | - norma-dmm | |
77 | - openbench-logic-sniffer | |
78 | - pipistrello-ols | |
79 | - rigol-ds | |
80 | - serial-dmm (including all subdrivers) | |
81 | - teleinfo | |
82 | - tondaj-sl-814 | |
83 | - uni-t-dmm (including all subdrivers) | |
84 | - uni-t-ut32x | |
85 | - victor-dmm | |
86 | - zeroplus-logic-cube | |
87 | ||
88 | ||
89 | Specifying serial ports | |
90 | ----------------------- | |
91 | ||
92 | Many devices supported by libsigrok use serial port based cables (real RS232 | |
93 | or USB-to-serial ones) to connect to a PC. | |
94 | ||
95 | For all these devices, you need to specify the serial port they are connected | |
96 | to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan | |
97 | for such devices without specifying a serial port. | |
98 | ||
99 | Example: | |
100 | ||
101 | $ sigrok-cli --driver <somedriver>:conn=/dev/ttyUSB0 ... | |
102 | ||
103 | The following drivers/devices require a serial port specification: | |
104 | ||
105 | - agilent-dmm | |
106 | - appa-55ii | |
107 | - atten-pps3xxx | |
108 | - brymen-dmm | |
109 | - cem-dt-885x | |
110 | - center-3xx (including all subdrivers) | |
111 | - colead-slm | |
112 | - conrad-digi-35-cpu | |
113 | - fluke-dmm | |
114 | - gmc-mh-1x-2x (including all subdrivers) | |
115 | - hameg-hmo | |
116 | - link-mso19 | |
117 | - mic-985xx (including all subdrivers) | |
118 | - norma-dmm | |
119 | - openbench-logic-sniffer | |
120 | - rigol-ds (for RS232; not required for USBTMC or TCP) | |
121 | - serial-dmm (including all subdrivers) | |
122 | - teleinfo | |
123 | - tondaj-sl-814 | |
124 | ||
125 | The following drivers/devices do not require a serial port specification: | |
126 | ||
127 | - asix-sigma | |
128 | - brymen-bm86x | |
129 | - chronovu-la | |
130 | - demo | |
131 | - fx2lafw | |
132 | - hantek-dso | |
133 | - ikalogic-scanalogic2 | |
134 | - ikalogic-scanaplus | |
135 | - kecheng-kc-330b | |
136 | - lascar-el-usb | |
137 | - pipistrello-ols | |
138 | - rigol-ds (USBTMC or TCP) | |
139 | - saleae-logic16 | |
140 | - sysclk-lwla | |
141 | - uni-t-dmm (including all subdrivers) | |
142 | - uni-t-ut32x | |
143 | - victor-dmm | |
144 | - zeroplus-logic-cube | |
145 | ||
146 | ||
147 | Specifiying serial port parameters | |
148 | ---------------------------------- | |
149 | ||
150 | Every serial device's driver has default serial port parameters like baud | |
151 | rate, number of data bits, stop bits and handshake status. If a device requires | |
152 | different parameters, pass them as option "serialcomm" with the driver name. | |
153 | See libsigrok docs for the function serial_set_paramstr() for complete specs. | |
154 | ||
155 | Example: | |
156 | ||
157 | $ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1 | |
158 | ||
159 | ||
160 | Permissions of serial port based devices | |
161 | ---------------------------------------- | |
162 | ||
163 | When using devices supported by libsigrok that use serial port based cables | |
164 | (real RS232 or USB-to-serial ones) to connect to a PC, you need to ensure | |
165 | that the user running the libsigrok frontend has (read/write) permissions to | |
166 | access the serial port device (e.g. /dev/ttyS0, /dev/ttyUSB0, and so on). | |
167 | ||
168 | You can use 'chmod' to apply permissions as you see fit, and/or 'chown' to | |
169 | change the owner of the serial port device to a certain user or group. | |
170 | ||
171 | For USB-to-serial based devices, we recommended using our udev rules file | |
172 | (see below for details). | |
173 | ||
174 | ||
175 | Permissions for USB devices (udev rules file) | |
176 | --------------------------------------------- | |
177 | ||
178 | When using USB-based devices supported by libsigrok, the user running the | |
179 | libsigrok frontend (e.g. sigrok-cli) has to have (read/write) permissions | |
180 | for the respective USB device. | |
181 | ||
182 | On Linux, this is accomplished using either 'chmod' (not recommended) or | |
183 | using the udev rules file shipped with libsigrok (recommended). | |
184 | ||
185 | The file is available in contrib/z60_libsigrok.rules. It contains entries | |
186 | for all libsigrok-supported (USB-based) devices and changes their group | |
187 | to 'plugdev' and the permissions to '664'. | |
188 | ||
189 | When using a libsigrok package from your favorite Linux distribution, the | |
190 | packager will have already taken care of properly installing the udev file | |
191 | in the correct (distro-specific) place, and you don't have to do anything. | |
192 | The packager might also have adapted 'plugdev' and '664' as needed. | |
193 | ||
194 | If you're building from source, you need to copy the file to the place | |
195 | where your distro expects such files. This is beyond the scope of this README, | |
196 | but generally the location could be e.g. /etc/udev/rules.d, or maybe | |
197 | /lib/udev/rules.d, or something else. Afterwards you might have to restart | |
198 | udev, e.g. via '/etc/init.d/udev restart' or similar, and you'll have to | |
199 | re-attach your device via USB. | |
200 | ||
201 | Please consult the udev docs of your distro for details. | |
202 | ||
203 | ||
204 | Cypress FX2 based devices | |
205 | ------------------------- | |
206 | ||
207 | Devices using the Cypress FX2(LP) chip without any specific USB VID/PID will | |
208 | be enumerated with VID/PID 04b4:8613 (the default for "unconfigured FX2"). | |
209 | These are usually "FX2 eval boards" (that can also be used as LAs, though). | |
210 | ||
211 | On Linux, the 'usbtest' driver will usually grab such devices, and they will | |
212 | thus not be usable by libsigrok (and frontends). | |
213 | ||
214 | You can fix this by running 'rmmod usbtest' as root before using the device. | |
215 | ||
216 | ||
217 | UNI-T DMM (and rebranded models) cables | |
218 | --------------------------------------- | |
219 | ||
220 | UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can | |
221 | ship with different PC connectivity cables: | |
222 | ||
223 | - UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490) | |
224 | - UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008) | |
225 | - UT-D02 (RS232 cable) | |
226 | ||
227 | The above cables are all physically compatible (same IR connector shape) | |
228 | with all/most currently known UNI-T multimeters. For example, you can | |
229 | use either of the UT-D04 USB/HID cables or the UT-D02 RS232 cable with | |
230 | the UNI-T UT61D multimeter. | |
231 | ||
232 | When using the UT-D02 RS232 cable with any of the supported UNI-T DMMs, | |
233 | you have to use the respective driver with a '-ser' drivername suffix | |
234 | (internally all of these models are handled by the 'serial-dmm' driver). | |
235 | ||
236 | You also need to specify the serial port via the 'conn' option, e.g. | |
237 | /dev/ttyUSB0 (attached via a USB-to-serial cable) or /dev/ttyS0 (actual | |
238 | RS232 port) on Linux (see above). | |
239 | ||
240 | Finally, the user running the frontend (e.g. sigrok-cli) also needs | |
241 | permissions to access the respective serial port (see above). | |
242 | ||
243 | Examples (sigrok-cli): | |
244 | ||
245 | $ sigrok-cli --driver uni-t-ut61e-ser:conn=/dev/ttyUSB0 ... | |
246 | $ sigrok-cli --driver voltcraft-vc820-ser:conn=/dev/ttyS0 ... | |
247 | ||
248 | When using any of the UT-D04 USB/HID cables you have to use the respective | |
249 | driver _without_ the '-ser' drivername suffix (internally all of these models | |
250 | are handled by the 'uni-t-dmm' driver). | |
251 | ||
252 | You also need to specify the USB vendor/device IDs of the cable. | |
253 | Autodetection is not possible here, since various other products use the | |
254 | USB VID/PID of those cables too, and there is no way to distinguish them. | |
255 | ||
256 | Since the UT-D04 cables are USB based (but don't use a USB-to-serial chip) | |
257 | there is no need to specify a serial port via 'conn', of course. | |
258 | However, the user running the frontend does also need to have permissions | |
259 | to access the respective USB device (see above). | |
260 | ||
261 | Examples (sigrok-cli): | |
262 | ||
263 | $ sigrok-cli --driver uni-t-ut61e:conn=1a86.e008 ... | |
264 | $ sigrok-cli --driver voltcraft-vc820:conn=04fa.2490 ... | |
265 | ||
266 | ||
267 | UNI-T UT-D04 cable issue on Linux | |
268 | --------------------------------- | |
269 | ||
270 | The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have | |
271 | a very specific problem on Linux. Apparently it requires to be put into | |
272 | suspend (and woken up again) before it is usable. This seems to be a | |
273 | Linux-only issue, Windows is not affected by this since apparently the | |
274 | Windows kernel does this for every USB device, always. | |
275 | ||
276 | Thus, if you want to use any of the UNI-T DMMs with this specific cable, | |
277 | you'll have to run the following script (as root) once, every time you attach | |
278 | the cable via USB. The script was written by Ralf Burger. | |
279 | ||
280 | See also: http://erste.de/UT61/index.html | |
281 | ||
282 | #!/bin/bash | |
283 | for dat in /sys/bus/usb/devices/*; do | |
284 | if test -e $dat/manufacturer; then | |
285 | grep "WCH.CN" $dat/manufacturer > /dev/null && echo auto > ${dat}/power/level && echo 0 > ${dat}/power/autosuspend | |
286 | fi | |
287 | done | |
288 | ||
289 | ||
290 | Enabling multimeter / data logger measurement output | |
291 | ---------------------------------------------------- | |
292 | ||
293 | Some multimeters or data loggers will not start outputting measurement data | |
294 | unless a certain action has been performed by the user beforehand. This is | |
295 | usually mentioned in the vendor manual of the respective device, but here's | |
296 | a short list for convenience: | |
297 | ||
298 | - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the | |
299 | interface panel on top. | |
300 | - Digitek DT4000ZC: Briefly press the "RS232" button. | |
301 | - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232: | |
302 | - Power on the device with the "DATA" button pressed. | |
303 | - Metrahit 2x devices must be configured for the respective interface type. | |
304 | - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232: | |
305 | - 'BD232' interface: | |
306 | The multimeter must be configured for the respective interface type. | |
307 | - 'SI232-II' interface ("PC Mode"): | |
308 | The multimeter must be configured for interface type 'BD232' (all), | |
309 | 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must | |
310 | be configured to the same baud rate as the host (default 9600). | |
311 | Multimeter and interface must be configured to the same address. | |
312 | - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power | |
313 | on the device with "FUNC" pressed (to power the interface from the DMM). | |
314 | - PCE PCE-DM32: Briefly press the "RS232" button. | |
315 | - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together. | |
316 | - TekPower TP4000ZC: Briefly press the "RS232" button. | |
317 | - Tenma 72-7750: Briefly press the "RS232C" button. | |
318 | - UNI-T UT60G: Briefly press the "RS232C" button. | |
319 | - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second. | |
320 | - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it | |
321 | appears that in practice you don't have to press the button (at least on | |
322 | some versions of the device), simply connect the device via USB. | |
323 | - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM. | |
324 | - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second. | |
325 | - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds. | |
326 | ||
327 | ||
328 | ChronoVu LA8/LA16 USB VID/PIDs | |
329 | ------------------------------ | |
330 | ||
331 | The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously, | |
332 | the device shipped with a USB VID/PID of 0403:6001, which is the standard ID | |
333 | for FTDI FT232 USB chips. | |
334 | ||
335 | Since this made it hard to distinguish the LA8/LA16 from any other device | |
336 | with this FTDI chip connected to the PC, the vendor later shipped the | |
337 | device with a USB VID/PID of 0403:8867. | |
338 | ||
339 | The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and | |
340 | automatically finds devices with either VID/PID pair. | |
341 | ||
342 | ||
343 | OLS | |
344 | --- | |
345 | ||
346 | The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer | |
347 | driver in libsigrok assumes a somewhat recent firmware has been flashed onto | |
348 | the OLS (it doesn't need a firmware upload every time it's attached via USB, | |
349 | since the firmware is stored in the device permanently). | |
350 | ||
351 | The most recent firmware version that is tested is 3.07. | |
352 | ||
353 | If you use any older firmware and your OLS is not found or is not working | |
354 | properly, please upgrade to at least this firmware version. Check the | |
355 | Dangerous Prototypes wiki for firmware upgrade instructions: | |
356 | ||
357 | http://dangerousprototypes.com/docs/Logic_Sniffer_upgrade_procedure | |
358 | ||
359 | Also, you need to specify a serial port for the OLS in the frontends, e.g. | |
360 | using the 'conn' option in sigrok-cli, and you also need to have the | |
361 | permissions to access the serial port (see above). | |
362 | ||
363 | Example: | |
364 | ||
365 | $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ... | |