Attaching a 'timing' decoder on a signal yields following view: http://public.pipapo.org/pulseview3.png There is enough space on the long gap in the signal to display the timing, but it is greyed out. Surprisingly when scrolling to the right, so that the end of that gap is not visible, the timing is rendered correctly: http://public.pipapo.org/pulseview4.png Scrolling to the left and changing zoom level still keeps it greyed out.
Hi, please attach a measurement that this happens with.
Created attachment 221 [details] sample (same as in bug #744) The problem shows up when you attach the 'timing' decoder to channel 2 or 3 (short spikes), but not on channel 5 (more evenly distributed signal)
Fix is here: https://github.com/abraxa/pulseview/commit/920eb49e49115b2d9bd85b8f9ec1a82f5c6e7671 Please report any further issues you encounter, thanks
Fixed in bdc2a99bcaa5aba7c6de2543bab6534299b8a5ee, thanks!
*** Bug 735 has been marked as a duplicate of this bug. ***