Bug 1525 - High voltage trace not displayed by PV
Summary: High voltage trace not displayed by PV
Status: RESOLVED FIXED
Alias: None
Product: PulseView
Classification: Unclassified
Component: Data display (show other bugs)
Version: 0.4.1
Hardware: All All
: Normal normal
Target Milestone: ---
Assignee: Nobody
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2020-03-20 15:39 CET by mrnuke
Modified: 2020-03-29 19:31 CEST (History)
1 user (show)



Attachments
Actual signal that was captured (33.21 KB, image/png)
2020-03-20 15:39 CET, mrnuke
Details
Waveform displayed by pulseview (106.29 KB, image/png)
2020-03-20 15:40 CET, mrnuke
Details
Capture file, as saved by pulseview (506 bytes, application/zip)
2020-03-20 15:40 CET, mrnuke
Details

Note You need to log in before you can comment on or make changes to this bug.
Description mrnuke 2020-03-20 15:39:02 CET
Created attachment 613 [details]
Actual signal that was captured

When viewing ridiculously high voltages PulseView does not display the trace.

Additional info:

The oscilloscope is configured to show 50V/div. Pulseview autoranges to 20V/div
CH4: 100x
Comment 1 mrnuke 2020-03-20 15:40:22 CET
Created attachment 614 [details]
Waveform displayed by pulseview
Comment 2 mrnuke 2020-03-20 15:40:50 CET
Created attachment 615 [details]
Capture file, as saved by pulseview
Comment 3 Uwe Hermann 2020-03-29 19:31:25 CEST
Fixed in 6202cf13abc361af4d1419dc56eaabc314900692, thanks!