Difference between revisions of "Siglent SDS2000X series"

From sigrok
Jump to navigation Jump to search
m
(7 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[File:SiglentSDS2X.png|thumb|right|Siglent SDS2304X]]
[[File:sds2304x-mugshot.png|thumb|right|Siglent SDS2304X]]


TODO: Description.
The '''Siglent SDS2000X series''' of oscilloscopes supports samplerates of 2GSa/s, up to 4 analog channels with up to 300MHz bandwidth, and up to 16 logic channels with up to 500MSa/s.
 
See [[Siglent SDS2000X series/Info]] for more details (such as '''lsusb -v''' output) about the device.


== Hardware ==
== Hardware ==


The Siglent SDS2000X series oscilloscopes are capable of sampling up to 2GSa/s 140 Mpts/CH memory for the analog channels. Due to the fact that the 2 channels are shared, if both channels are on the sampling is limited to 1GSa/s and 70 Mpts/CH memory per channel. This is also true with the 4 channel devices. The analog channels have history memory where 80000 frames are stored and can be viewed via the scopes History function.  
The Siglent SDS2000X series oscilloscopes are capable of sampling up to 2GSa/s 140 Mpts/CH memory for the analog channels. Due to the fact that the 2 channels are shared, if both channels are on the sampling is limited to 1GSa/s and 70 Mpts/CH memory per channel. This is also true with the 4 channel devices. The analog channels have history memory where 80000 frames are stored and can be viewed via the scopes History function.


All device have the Logic Analyzer and DDS arbitrary waveform generator build in. Keep in mind that for the Logic Analyzer and waveform generator an extra software option must be purchased. For the Logic Analyzer and additional probe device (SPL2016) must also be purchased. The Logic Analyzer is capable 500 MSa/s with 140 Mpts/CH memory.
All devices have the logic analyzer and DDS arbitrary waveform generator built-in. Keep in mind that for the logic analyzer and waveform generator an extra software option must be purchased. For the logic analyzer an additional probe device (SPL2016) must also be purchased. The logic analyzer is capable 500 MSa/s with 140 Mpts/CH memory.


An extra software option to decode serial protocols is also available on all devices.
An extra software option to decode serial protocols is also available on all devices.


The model numbers are for the 2 channel 70Mhz bw: SDS2072X, 100Mhz bw: SDS2102X, 200Mhz bw: SDS2202X and 300Mhz bw: SDS3202X
{| class="wikitable"
The model numbers are for the 4 channel 70Mhz bw: SDS2074X, 100Mhz bw: SDS2104X, 200Mhz bw: SDS2204X and 300Mhz bw: SDS3204X
!Model || Bandwidth || Analog channels || Digital channels
|-
|| SDS2304X || 300MHz || 4 || 16
|-
|| SDS2302X || 300MHz || 2 || 16
|-
|| SDS2204X || 200MHz || 4 || 16
|-
|| SDS2202X || 200MHz || 2 || 16
|-
|| SDS2104X || 100MHz || 4 || 16
|-
|| SDS2102X || 100MHz || 2 || 16
|-
|| SDS2074X || 70MHz || 4 || 16
|-
|| SDS2072X || 70MHz || 2 || 16
|}


== Photos ==
== Photos ==


<gallery>
<gallery>
File:SiglentSDS2X.png|<small>Siglent SDS2304X</small>
File:sds2304x-front.png|<small>SDS2304X, front view</small>
File:SiglentSPL2016.png|<small>Siglent Logic-Probe SPL2016</small>
File:sds2000x-connectors.png|<small>SDS2000X, rear connectors</small>
File:sds2000x-analog-probe.png|<small>Analog probe (one per channel)</small>
File:sds2000x-logic-probe-2.png|<small>Logic probes cable, PCIe to IDC, SPL2016</small>
File:sds2000x-logic-probe-1.png|<small>Logic probes, IDC to cable ends, EZ-Hooks</small>
File:sds2000x-logic-probe-3.png|<small>Logic probes, IDX boxes, colour codes, 2x GND per 8 channels</small>
</gallery>
</gallery>


Line 34: Line 57:
[[Category:Oscilloscope]]
[[Category:Oscilloscope]]
[[Category:Mixed-signal oscilloscope]]
[[Category:Mixed-signal oscilloscope]]
[[Category:Planned]]
[[Category:In progress]]

Revision as of 23:32, 3 June 2017

Siglent SDS2304X

The Siglent SDS2000X series of oscilloscopes supports samplerates of 2GSa/s, up to 4 analog channels with up to 300MHz bandwidth, and up to 16 logic channels with up to 500MSa/s.

See Siglent SDS2000X series/Info for more details (such as lsusb -v output) about the device.

Hardware

The Siglent SDS2000X series oscilloscopes are capable of sampling up to 2GSa/s 140 Mpts/CH memory for the analog channels. Due to the fact that the 2 channels are shared, if both channels are on the sampling is limited to 1GSa/s and 70 Mpts/CH memory per channel. This is also true with the 4 channel devices. The analog channels have history memory where 80000 frames are stored and can be viewed via the scopes History function.

All devices have the logic analyzer and DDS arbitrary waveform generator built-in. Keep in mind that for the logic analyzer and waveform generator an extra software option must be purchased. For the logic analyzer an additional probe device (SPL2016) must also be purchased. The logic analyzer is capable 500 MSa/s with 140 Mpts/CH memory.

An extra software option to decode serial protocols is also available on all devices.

Model Bandwidth Analog channels Digital channels
SDS2304X 300MHz 4 16
SDS2302X 300MHz 2 16
SDS2204X 200MHz 4 16
SDS2202X 200MHz 2 16
SDS2104X 100MHz 4 16
SDS2102X 100MHz 2 16
SDS2074X 70MHz 4 16
SDS2072X 70MHz 2 16

Photos

Protocol

All devices support USB (USBTMC) and LAN (VXI-11) by default, and are implementing the IEEE488.2 protocol.

Resources