Difference between revisions of "RS PRO S2"

From sigrok
Jump to navigation Jump to search
(→‎Hardware: MCU, ADC, BLE SoC)
(Photos and Teardown)
Line 26: Line 26:
** '''Current range 400mA''': Amp rating: 0.44A, Voltage rating: 1kV, Interrupting rating: 10kA, Opening: Fast acting, Size: 10mm x 34.9mm
** '''Current range 400mA''': Amp rating: 0.44A, Voltage rating: 1kV, Interrupting rating: 10kA, Opening: Fast acting, Size: 10mm x 34.9mm
* '''Power supply:''' 2 x IEC LR6 1.5V (works fine with IEC HR6 1.2V)
* '''Power supply:''' 2 x IEC LR6 1.5V (works fine with IEC HR6 1.2V)
= Photos and Teardown =
<gallery>
File:RS PRO S2 - 01 - Front.png|<small>Front view</small>
File:RS PRO S2 - 02 - SmuView.png|<small>S2 connected to SmuView visualizing readings from the power grid</small>
File:RS PRO S2 - 03.jpg|<small>Measuring voltage from the power grid</small>
File:RS PRO S2 - 04 - Display-Light.jpg|<small>Display close-up with backlight on</small>
File:RS PRO S2 - 05 - Rear.jpg|<small>Rear view</small>
File:RS PRO S2 - 06 - Magnetic sticker.jpg|<small>Magnetic sticker close up</small>
File:RS PRO S2 - Magnetic sticker.jpg|<small>Magnetic sticker inside view</small>
File:RS PRO S2 - 07.jpg|<small>Protective sleeve removed</small>
File:RS PRO S2 - 08 - Rear.jpg|<small>Rear</small>
File:RS PRO S2 - Teardown - 01.jpg|<small>Teardown 1/12</small>
File:RS PRO S2 - Teardown - 02.jpg|<small>Teardown 2/12</small>
File:RS PRO S2 - Teardown - 03.jpg|<small>Teardown 3/12</small>
File:RS PRO S2 - Teardown - 04.jpg|<small>Teardown 4/12</small>
File:RS PRO S2 - Teardown - 05.jpg|<small>Teardown 5/12</small>
File:RS PRO S2 - Teardown - 06.jpg|<small>Teardown 6/12</small>
File:RS PRO S2 - Teardown - 07.jpg|<small>Teardown 7/12</small>
File:RS PRO S2 - Teardown - 08.jpg|<small>Teardown 8/12</small>
File:RS PRO S2 - Teardown - 09.jpg|<small>Teardown 9/12</small>
File:RS PRO S2 - Teardown - 10.jpg|<small>Teardown 10/12</small>
File:RS PRO S2 - Teardown - 11.jpg|<small>Teardown 11/12</small>
File:RS PRO S2 - Teardown - 12.jpg|<small>Teardown 12/12</small>
</gallery>


= Resources =
= Resources =

Revision as of 18:10, 26 November 2020

RS PRO S2
RS PRO S2 - 01 - Front.png
Status in progress
Source code appa-dmm
Counts 6000
IEC 61010-1 CAT III (1000V) / CAT IV (600V)
Connectivity Bluetooth LE
Measurements voltage, frequency, resistance, continuity, diode, capacitance, current, temperature
Features autorange, data hold, min/max, relative, non-contact voltage detection hi/lo, backlight, true-rms, data logging, single value storage, auto-v/loz, VFD, built-in magnetic sticker, µA current range
Website rsonline-privat.de

The RS PRO S2 is a 6000 counts, CAT IV (600V) / CAT III (1000V) handheld logging digital multimeter with Bluetooth LE connectivity and long battery duration. It is marketed as a "HVAC Multimeter" (optimized for the needs of heating, ventilation, and air conditioning technicians).

It is based on the APPA S2, See also: APPA Multimeters.

A sigrok-driver supporting these APPA-based devices ("appa-dmm" in sigrok) has been created and will be included in mainline sigrok once it passes acception (see developement repository github.com/Cymaphore/libsigrok branch appa-dmm).

Hardware

  • MCU: Atmel ATSAML22N18A-U
  • ADC-ID: Hycontek HY12P65
  • BLE-SoC: AMICCOM A8105
  • Fuses:
    • Current range 400mA: Amp rating: 0.44A, Voltage rating: 1kV, Interrupting rating: 10kA, Opening: Fast acting, Size: 10mm x 34.9mm
  • Power supply: 2 x IEC LR6 1.5V (works fine with IEC HR6 1.2V)

Photos and Teardown

Resources