Difference between revisions of "Protocol decoder:Easymatic"

From sigrok
Jump to navigation Jump to search
Line 72: Line 72:
{|  class="alternategrey sortable sigroktable"
{|  class="alternategrey sortable sigroktable"
!Frame (first byte)
!Frame (first byte)
!Equipement
!2sd byte
!2sd byte
!3th byte
!3th byte
Line 81: Line 82:
|-
|-
| 0A
| 0A
| Easymatic
| ?
| ?
| colspan="2"|?
| colspan="2"|?
Line 89: Line 91:
|-
|-
| 0B
| 0B
| Boiler
| ?
| ?
| ?
| ?
Line 97: Line 100:
|-
|-
| 0C
| 0C
| Easymatic
| 00?
| 00?
| colspan="2"| T°C max boiler
| colspan="2"| T°C max boiler
Line 104: Line 108:
|-
|-
| 0D
| 0D
| Boiler
| 00?
| 00?
| 00?
| 00?
Line 112: Line 117:
|-
|-
| 0E
| 0E
| Easymatic
| Hour
| Hour
| Day
| Day
Line 121: Line 127:
|-
|-
| 01
| 01
| Boiler
| 40?
| 40?
| colspan="2"| T°C drink water
| colspan="2"| T°C drink water
Line 128: Line 135:
|-
|-
| 02
| 02
| Easymatic
| C1?
| C1?
| colspan="2"| Set point room T°C day
| colspan="2"| Set point room T°C day
Line 135: Line 143:
|-
|-
| 03
| 03
| Boiler
| 00?
| 00?
| ?
| ?
Line 144: Line 153:
|-
|-
| 04
| 04
| Easymatic
| 05?
| 05?
| colspan="2"| Set point frost protection room T°C
| colspan="2"| Set point frost protection room T°C
Line 151: Line 161:
|-
|-
| 05
| 05
| Boiler
| Boiler bits command
| Boiler bits command
| colspan="2"| Set point frost protection room T°C
| colspan="2"| Set point frost protection room T°C

Revision as of 14:52, 21 November 2017

easymatic
File:Easymatic.jpg
Name EASYMATIC
Description Asynchronous, serial bus, differential
Status planned
License GPLv2+
Source code decoders/uart
Input logic
Output Easymatic protocol
Probes
Optional probes Thermostat, Boiler
Options invert_thermostat, invert_boiler

The easymatic protocol decoder can decode the thermostat Easymatic bus protocol used by De Dietrich.

Hardware

Differential link

The easymatic is linked to the boiler with two wires. This link can feed power to the easymatic. Easymatic can have two R4 accu in order to save data if the power cut. Boiler power is a 24V modulated with communication power.

Communication is always working.

[To be confirmed]

The hardware is similar to OpenTherm Specifications : - differential link - about 24V - tension modulation for boiler - intensity modulation for thermostat (easymatic) ?

In order to link with a logic analyzer Saleae Logic an interface must be done.

Electrical coding

[To be define]

Idle state

[To be define]

Protocol

Uart based

Whereas OpenTherm use Manchester code, the easymatic seems to be based on Universal Asynchronous Receiver Transmitter (UART). It's a : - 1200 bauds communication. - 8 bits of data - no parity - one stop bit

The bit order of the 8 data bits is LSB-first.

details

[To be discovered and detailed]

Frames are repeated twice

To be define : how an order is send

All frame are composed by 6 bytes Boiler frames begin with a byte in 01, 03, 05, 07, 09, 0B, 0D Thermostat frames begin with a "boiler beginning frame +1" : 02, 04, 06, 08, 0A, 0C, 0E

Frame 0A/0B

Frame (first byte) Equipement 2sd byte 3th byte 4th byte 5th byte 6th byte Comments
0A Easymatic ? ? ? ? ?
0B Boiler ? ? ? T°C exterior example : 70,0°C = 0700DEC = 02BCHEX
0C Easymatic 00? T°C max boiler Set point frost protection T°C exterior
0D Boiler 00? 00? 00? T°C exterior
0E Easymatic Hour Day Minutes FF? FF?
01 Boiler 40? T°C drink water T°C boiler water
02 Easymatic C1? Set point room T°C day Set point room T°C night
03 Boiler 00? ? ? ? ?
04 Easymatic 05? Set point frost protection room T°C Set point T°C drink water
05 Boiler Boiler bits command Set point frost protection room T°C Set point T°C drink water