Difference between revisions of "Kingst LA5016"

From sigrok
Jump to navigation Jump to search
(fixup image refs)
(reference "the series" from the LA5016 device page)
 
Line 7: Line 7:
| samplerate      = 500MHz max.
| samplerate      = 500MHz max.
| samplerate_state = —
| samplerate_state = —
| triggers        = Level (multiple channels)<br/>Edge (one channel)
| triggers        = Level, Edge
| voltages        = -50V &mdash; 50V tolerant
| voltages        = -50V &mdash; +50V tolerant
| threshold        = -4.0V&mdash;+4.0V, min step 0.01V
| threshold        = -4.0V &mdash; +4.0V, min step 0.01V
| memory          = 2Gib RAM (256MiB)
| memory          = 2Gib RAM (256MiB)
| compression      = Yes
| compression      = Yes
Line 16: Line 16:


The '''Kingst LA5016''' is a USB-based, 16-channel logic analyser with 500MHz maximum sampling rate and 256MiB sample memory.
The '''Kingst LA5016''' is a USB-based, 16-channel logic analyser with 500MHz maximum sampling rate and 256MiB sample memory.
It is part of the '''Kingst LA series''', see the [[Kingst LA2016]] page for more details. All devices are supported by a single driver named '''kingst-la2016'''.
It is part of the [[Kingst LA Series]] and is supported by the '''kingst-la2016''' sigrok driver.


The USB identification is identical to Kingst LA2016, the same VID:PID and the same USB endpoints are used.
The USB identification is shared among Kingst LA devices. See [[Kingst LA2016]], the same VID:PID and the same USB endpoints are used.


== Hardware ==
== Hardware ==
Line 44: Line 44:
== Protocol ==
== Protocol ==


See the [[Kingst LA2016]] device page. It's all the same just with a higher maximum samplerate, and a different base clock.
See the [[Kingst LA Series]] page, all devices communicate to the host in identical ways.


== Firmware ==
== Firmware ==


Device firmware must be extracted from vendor software before sigrok use. See [[Kingst LA2016]] for details.
Device firmware must be extracted from vendor software before sigrok use. See [[Kingst LA Series]] for details.


[[Category:Device]]
[[Category:Device]]
[[Category:Logic analyzer]]
[[Category:Logic analyzer]]
[[Category:Supported]]
[[Category:Supported]]

Latest revision as of 15:25, 27 February 2022

Kingst LA5016
Kingst-la5016-mugshot.png
Status supported
Source code kingst-la2016
Channels 16
Samplerate 500MHz max.
Samplerate (state)
Triggers Level, Edge
Min/max voltage -50V — +50V tolerant
Threshold voltage -4.0V — +4.0V, min step 0.01V
Memory 2Gib RAM (256MiB)
Compression Yes
Website qdkingst.com

The Kingst LA5016 is a USB-based, 16-channel logic analyser with 500MHz maximum sampling rate and 256MiB sample memory. It is part of the Kingst LA Series and is supported by the kingst-la2016 sigrok driver.

The USB identification is shared among Kingst LA devices. See Kingst LA2016, the same VID:PID and the same USB endpoints are used.

Hardware

TODO Add more details.

  • Cypress FX2 MCU
  • AT24C02 EEPROM
  • Cyclone IV FPGA (Altera/Intel)
  • U10 authentication device
  • 2Gib DRAM
  • a bunch of regulators
  • opamp for input threshold control

Photos

Protocol

See the Kingst LA Series page, all devices communicate to the host in identical ways.

Firmware