Difference between revisions of "Hantek DSO-2250"

From sigrok
Jump to navigation Jump to search
Line 39: Line 39:
File:Dso2250-capture-channels.jpg|<small>Input channels front</small>
File:Dso2250-capture-channels.jpg|<small>Input channels front</small>
File:Dso2250-Cypress.jpg|<small>FX2 and EEPROM</small>
File:Dso2250-Cypress.jpg|<small>FX2 and EEPROM</small>
File:Dso2250-signal-gen.jpg|<small>1khz 2VPP signal generation circuitry, Cypress main EEPROM (U807), 3V3? Supply TPS54286</small>
File:Dso2250-signal-gen.jpg|<small>1khz 2VPP signal generation circuitry, Cypress main EEPROM (U807), 3V3? Supply TPS54286(U27)</small>
</gallery>
</gallery>



Revision as of 12:38, 24 March 2013

The Hantek DSO-2250 is an inexpensive USB-based oscilloscope. It has 2 channels, an analog bandwidth of 100MHz and 250MS/s sampling rate.

See Hantek DSO-2250/Info for more details (such as lsusb -vvv output) about the device.

For more information about the devices in Hantek's USB oscilloscope series, see Hantek DSO-2xxx/52xx.

Hardware

  • Main chip:Xilinx SPARTAN XC3S50AN
  • Main Oscillator: 100MHz 100.000 YX NH
  • USB: Cypress CY7C68013A-100AXC (FX2)
  • 512K x 8 High-speed CMOS static RAM: 2x ISSI IS61LV5128AL-10TLI (datasheet)
  • I2C EEPROM: Microchip 24LC02BI (for the USB VID/PID of the Cypress FX2)
  • Main Power Supply? (near the 1Khz 2VPP signal gen): TPS54286 (datasheet)
  • HC244SJ - octal buffer / line driver for SRAM? (U23)

Input stage (per channel):

Photos

Protocol

See Hantek_DSO-2xxx/52xx#Protocol.

Extracting the firmware

See Hantek_DSO-2xxx/52xx#Extracting_the_firmware.

Resources