Difference between revisions of "Gossen Metrawatt Metrahit X-Tra"

From sigrok
Jump to navigation Jump to search
m (Intermediate storage)
Line 3: Line 3:
| name            = Gossen Metrawatt Metrahit X-Tra
| name            = Gossen Metrawatt Metrahit X-Tra
| status          = planned
| status          = planned
<!--| source_code_dir = gmc-mh-sl -->
| source_code_dir = <!-- gmc-mh-sl -->
| counts          = 31000
| counts          = 31000
| categories      = CAT III 1000 V, CAT IV 600 V
| categories      = CAT III 1000 V, CAT IV 600 V
| connectivity    = Infrared (RS232)
| connectivity    = Infrared (USB)
| measurements    = voltage, current, resistance, capacitance, temperature, frequency, diode, continuity
| measurements    = voltage, current, resistance, capacitance, temperature, frequency, diode, continuity
| features        = autorange, data hold
| features        = autorange, data hold
| website        = [http://www.gossenmetrawatt.com/english/produkte/metrahit25s.htm]
| website        = [http://www.gossenmetrawatt.com/english/produkte/metrahitx-tra.htm]
}}
}}


Line 23: Line 23:
<!--
<!--
== Photos ==
== Photos ==


<gallery>
<gallery>
Line 35: Line 34:
== Using the device with sigrok ==
== Using the device with sigrok ==
The device is planned to be supported using a [[Gossen_Metrawatt#USB_X-Tra | USB X-Tra interface]] or similar IR to USB interface.<!-- by the driver gmc-mh-1x-2x-rs232 (actually this should work, but with [[User:Matthias Heidbrink | Matthias']] test device it did not, so it's untested). Set the multimeter to use the communication adaptor ''RS232''. -->
The device is planned to be supported using a [[Gossen_Metrawatt#USB_X-Tra | USB X-Tra interface]] or similar IR to USB interface.<!-- by the driver gmc-mh-1x-2x-rs232 (actually this should work, but with [[User:Matthias Heidbrink | Matthias']] test device it did not, so it's untested). Set the multimeter to use the communication adaptor ''RS232''. -->
<!--


== Measurement functions and ranges ==
== Measurement functions and ranges ==
Line 51: Line 48:
|-
|-
| rowspan="5" | V=
| rowspan="5" | V=
| 300 mV
| 100 mV
| 10 μV
| 10 μV
| rowspan="5" |±(0,05% 3)  
| rowspan="5" |±(0,09% 3)  
| mq V, unit V, mqflags DC
| mq V, unit V, mqflags DC
|  
| with ZERO


|-
|-
| 3 V
| 1 V
| 100 μV
| 100 μV
| "
| rowspan="4" |±(0,05% 3)
|  
|  


|-
|-
| 30 V
| 10 V
| 1 mV
| 1 mV
| "
| "
Line 70: Line 67:


|-
|-
| 300 V
| 100 V
| 10 mV
| 10 mV
| "
| "
Line 83: Line 80:
|-
|-
| rowspan="5" | V≈
| rowspan="5" | V≈
| 300 mV
| 100 mV
| 100 µV
| 10 µV
| ±(0,5% + 30) (> 500 Digit))
| ±(1% + 30) (> 300 Digit))
| mq V, unit V, mqflags AC,RMS
| mq V, unit V, mqflags AC,RMS
|
| min. 200 µV


|-
|-
| 3 V
| 1 V
| 100 μV
| 100 μV
| rowspan="4" | ±(0,2% + 30)
| rowspan="4" | ±(0,5% + 30) (> 200 Digit))
| "
| "
|  
|  


|-
|-
| 30 V
| 10 V
| 1 mV
| 1 mV
| "
| "
Line 103: Line 100:


|-
|-
| 300 V
| 100 V
| 10 mV
| 10 mV
| "
| "
Line 115: Line 112:


|-
|-
| V db≈
| rowspan="6" | XXX A=
| -48 - 63 dB
| 0,01 dB
| ± 0,1 dB
| mq V, unit V, mqflags AC,RMS
| Actually the 5 AC ranges, see there for accuracy.
 
|-
| rowspan="6" | A=
| 300.00 µA
| 300.00 µA
| 10 nA
| 10 nA
Line 164: Line 153:


|-
|-
| rowspan="6" | A≃
| rowspan="6" | XXX A≃
| 300.00 µA
| 300.00 µA
| 10 nA
| 10 nA
Line 202: Line 191:
|  
|  
|-
|-
| rowspan="6" | Ω
| rowspan="6" | XXX Ω
| 300.00 Ω
| 300.00 Ω
| 10 mΩ
| 10 mΩ
Line 241: Line 230:


|-
|-
| Ohm/Cont.
| XXX Ohm/Cont.
| 300 Ω
| 300 Ω
| 100 mΩ
| 100 mΩ
Line 249: Line 238:


|-
|-
| Diode
| XXX Diode
| 3 V
| 3 V
| 1 mV
| 1 mV
Line 257: Line 246:


|-
|-
| rowspan="8" | Cap. F
| rowspan="8" | XXX Cap. F
| 3.000 nF
| 3.000 nF
| 1 pF
| 1 pF
Line 309: Line 298:


|-
|-
| rowspan="3" | Hz≈, ≃
| rowspan="3" | Hz (V)
| 300.00 Hz
| 100.00 Hz
| 0.01 Hz
| 0.01 Hz
| rowspan="3" | ±(0.1% + 1)
| rowspan="5" | ±(0.05% + 3)
| mq Freq., unit Hz, mqflags AC,DC
| mq Freq., unit Hz, mqflags AC,DC
| To activate in AC, press yellow button twice.
|  


|-
|-
| 3.0000 kHz
| 100.00 kHz
| 0.1 Hz
| 10 Hz
| "
| "
|  
|  


|-
|-
| 100.000 kHz
| 100.00 Hz -<br/>1.0000 MHz
| 10 Hz
| 0.01 Hz - 100 Hz
| "
| "
| MHz mode, voltage must not exceed 5 V!
|-
| rowspan="2" | Hz (A)
| 1,0000 kHz
| 0.1 Hz
| mq Freq., unit Hz, mqflags AC,DC
|  
|  


|-
|-
| rowspan="3" | °C
| 30.00 kHz
| Pt100/Pt1000<br> –200.0 - -100.0 °C
| 10 Hz
| rowspan="3" | 0.1 °C
| "
| 1 K
|  
| mq Temp., unit °C, mqflags -
|


|-
|-
| Pt100/Pt1000<br> -100.0 - +100.0 °C
| rowspan="3" | %
| 0,8 K
| 2,0-98%<br/>100 Hz - 1 kHz
| "
| rowspan="3" | 0.01 %
|
| ±(0,1%)
| mq Duty., unit %, mqflags -
|  


|-
|-
| Pt100/Pt1000<br> +100.0 - +850.0 °C
| 5,0-95%<br/> ... - 10 kHz
| ±(0,5% + 3)
| rowspan="2" | ±(0,1% per kHz)
| "
| "
|
|  


|-
|-
| °F
| 10-90%<br/> ... - 100 kHz
| "
| "
| "
|  
| "
| style="background: #FFFF00" | mq Temp., unit °C (!), mqflags -
| Details and ranges like °C. The protocol does not allow to distinguish between °C and °F, so the unit is always °C.




|-
| rowspan="3" | °C/°F
| Pt100<br>–200.0 - +850.0 °C
| rowspan="3" | 0.1 °C
| rowspan="2" | ±(0,3% +15)
| mq Temp., unit °C/°F, mqflags -
| Measurement switchable between °C and °F.


|-
|-
| Event count 
| Pt1000<br> -150.0 - +850.0 °C
|
| "
|
|
 
| style="background: #FFFF00; "| mq V, unit V, mqflags AC,RMS,REL
| To activate, switch to voltage AC, press yellow button twice. Press up to 4 times to cycle parameters, press long to stop. See manual. Not useful remotely because the voltage measurement value is sent, not the counter.
|-
|-
| Stop Watch 
| Type K<br> -250 - +1372.0 °C
|
| ±(1% + 5K)
|  100 ns
| "
|
|
| style="background: #ff0000; "| (Time data)
| Max. 100 Min. Press AUTO for start/stop, DATA for reset. Not useful remotely because the stop watch delivers only zeros.
|-
| Data Hold 
|
|
| style="background: #ff0000; "| mqflags += HOLD
| Disabled while IR interface is active on [[User:Matthias Heidbrink | Matthias']] test device.
|-
| MIN
|
|
| style="background: #ff0000; "| mqflags += MIN
| Influences only display, via IR flag is set, but actual current value is delivered.
|-
| MAX
|
|
| style="background: #ff0000; "| mqflags += MAX
| Influences only display, via IR flag is set, but actual current value is delivered.


|-
|-
|}
|}
The ''Accuracy'' row was simplified, see manual for exact specs. If the value contains three values, the middle value is % or range.
The ''Accuracy'' row was simplified, see manual for exact specs.


The column "sigrok result" contains in short form what the driver generates for the resp. data type.
The column "sigrok result" contains in short form what the driver generates for the resp. data type.
-->
 





Revision as of 00:22, 31 March 2016

Gossen Metrawatt Metrahit X-Tra
Status planned
Counts 31000
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (USB)
Measurements voltage, current, resistance, capacitance, temperature, frequency, diode, continuity
Features autorange, data hold
Website [1]

The Gossen Metrawatt Metrahit X-Tra is a 4.5 digit, 12000 counts 1000V CAT III/600 V CAT IV handheld digital multimeter with IR (USB) connectivity.

Hardware

  • Power supply:
    • Battery: 2x 1,5 V IEC R 6, IEC LR 6 or corresponding NiCd rechargeable batteries
  • Fuse:
    • Current: FF (UR) 10 A/1000 V AC/DC (30 kA) 10 mm x 38 mm

Using the device with sigrok

The device is planned to be supported using a USB X-Tra interface or similar IR to USB interface.

Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 100 mV 10 μV ±(0,09% 3) mq V, unit V, mqflags DC with ZERO
1 V 100 μV ±(0,05% 3)
10 V 1 mV "
100 V 10 mV "
1000 V 100 mV "
V≈ 100 mV 10 µV ±(1% + 30) (> 300 Digit)) mq V, unit V, mqflags AC,RMS min. 200 µV
1 V 100 μV ±(0,5% + 30) (> 200 Digit)) "
10 V 1 mV "
100 V 10 mV "
1000 V 100 mV "
XXX A=  300.00 µA 10 nA 0,1% + 5 mq Curr., unit A, mqflags DC
3.0000 mA 100 nA "
30.000 mA 1 mA 0,05% + 5 "
300.00 mA 10 µA 0,5% + 5 "
3.0000 A 100 µA 0,5% + 10 "
10.000 A 1 mA "
XXX A≃  300.00 µA 10 nA 0,5% + 30 mq Curr., unit A, mqflags AC,DC,RMS
3.0000 mA 100 nA "
30.000 mA 1 µA "
300.00 mA 10 µA "
3.0000 A 100 µA 0,75% + 30 "
10.000 A 1 mA "
XXX Ω 300.00 Ω 10 mΩ 0,1% + 5 mq Res., unit Ω, mqflags -
3.0000 kΩ 100 mΩ "
30.000 kΩ 1 Ω "
300.00 kΩ 10 Ω "
3.0000 MΩ 100 Ω "
30.000 MΩ 1k Ω 2% + 5 "
XXX Ohm/Cont. 300 Ω 100 mΩ 1% + 3% mq Res., unit Ω, mqflags -
XXX Diode 3 V 1 mV 0.2% + 3 mq V, unit V, mqflags DC,DIODE
XXX Cap. F 3.000 nF 1 pF 1.0% + 5 mq Cap., unit F, mqflags -
30.00 nF 10 pF "
300.0 nF 100 pF "
3.000 µF 1 nF "
30.00 µF 10 nF "
300.0 µF 100 nF ±(5.0% + 6) "
3.000 mF 1 µF "
30.00 mF 1 µF ±(5.0% + 30) "
Hz (V) 100.00 Hz 0.01 Hz ±(0.05% + 3) mq Freq., unit Hz, mqflags AC,DC
100.00 kHz 10 Hz "
100.00 Hz -
1.0000 MHz
0.01 Hz - 100 Hz " MHz mode, voltage must not exceed 5 V!
Hz (A) 1,0000 kHz 0.1 Hz mq Freq., unit Hz, mqflags AC,DC
30.00 kHz 10 Hz "
% 2,0-98%
100 Hz - 1 kHz
0.01 % ±(0,1%) mq Duty., unit %, mqflags -
5,0-95%
... - 10 kHz
±(0,1% per kHz) "
10-90%
... - 100 kHz
"


°C/°F Pt100
–200.0 - +850.0 °C
0.1 °C ±(0,3% +15) mq Temp., unit °C/°F, mqflags - Measurement switchable between °C and °F.
Pt1000
-150.0 - +850.0 °C
"
Type K
-250 - +1372.0 °C
±(1% + 5K) "

The Accuracy row was simplified, see manual for exact specs.

The column "sigrok result" contains in short form what the driver generates for the resp. data type.