Difference between revisions of "Gossen Metrawatt Metrahit 18S"

From sigrok
Jump to navigation Jump to search
m (Fixed C&P error)
 
(4 intermediate revisions by the same user not shown)
Line 3: Line 3:
| name            = [[Gossen Metrawatt]] Metrahit 18S
| name            = [[Gossen Metrawatt]] Metrahit 18S
| status          = supported
| status          = supported
| source_code_dir = gmx_mh_1x_2x
| source_code_dir = gmc-mh-1x-2x
| counts          = 31000
| counts          = 31000
| categories      = CAT III 1000 V, CAT IV 600 V
| categories      = CAT III 1000 V, CAT IV 600 V
Line 50: Line 50:
| 300 mV
| 300 mV
| 10 μV
| 10 μV
| ±(0,05% + 3)
| ±(0.05% + 3)
| mq V, unit V, mqflags DC
| mq V, unit V, mqflags DC
|  
| Input Impendance >10 GΩ


|-
|-
| 3 V
| 3 V
| 100 μV
| 100 μV
| rowspan="4" | ±(0,05% + 3)
| rowspan="4" | ±(0.05% + 3)
| "
| "
|  
|  
Line 63: Line 63:
|-
|-
| 30 V
| 30 V
| 100 μV
| 1 mV
| "
| "
|  
|  
Line 69: Line 69:
|-
|-
| 300 V
| 300 V
| 1 mV
| 10 mV
| "
| "
|  
|  
Line 75: Line 75:
|-
|-
| 1000 V
| 1000 V
| 10 mV
| 100 mV
| "
| "
|  
|  
Line 83: Line 83:
| 300 mV
| 300 mV
| 10 µV
| 10 µV
| ±(0,5% + 30) (> 500 Digit))
| ±(0.5% + 30) (> 500 Digit))
| mq V, unit V, mqflags AC,RMS
| mq V, unit V, mqflags AC,RMS
|
|
Line 90: Line 90:
| 3 V
| 3 V
| 100 μV
| 100 μV
| rowspan="4" | ±(0,5% + 30) (> 300 Digit)
| rowspan="4" | ±(0.5% + 30) (> 300 Digit)
| "
| "
|  
|  
Line 96: Line 96:
|-
|-
| 30 V
| 30 V
| 100 μV
| 1 mV
| "
| "
|  
|  
Line 102: Line 102:
|-
|-
| 300 V
| 300 V
| 1 mV
| 10 mV
| "
| "
|  
|  
Line 108: Line 108:
|-
|-
| 1000 V
| 1000 V
| 10 mV
| 100 mV
| "
| "
|  
|  
Line 116: Line 116:
| 300 mV
| 300 mV
| 10 μV
| 10 μV
| ±(0,5% + 30) (> 500 Digit))
| ±(0.5% + 30) (> 500 Digit))
| mq V, unit V, mqflags AC,DC,RMS
| mq V, unit V, mqflags AC,DC,RMS
|  
|  
Line 123: Line 123:
| 3 V
| 3 V
| 100 μV
| 100 μV
| rowspan="4" | ±(0,5% + 30) (> 300 Digit)
| rowspan="4" | ±(0.5% + 30) (> 300 Digit)
| "
| "
|  
|  
Line 129: Line 129:
|-
|-
| 30 V
| 30 V
| 100 μV
| 1 mV
| "
| "
|  
|  
Line 135: Line 135:
|-
|-
| 300 V
| 300 V
| 1 mV
| 10 mV
| "
| "
|  
|  
Line 141: Line 141:
|-
|-
| 1000 V
| 1000 V
| 10 mV
| 100 mV
| "
| "
|  
|  
Line 148: Line 148:
| V db≈
| V db≈
| -48 - 63 dB
| -48 - 63 dB
| 0,01 dB
| 0.01 dB
|  
|  
| mq V, unit V, mqflags AC,RMS
| mq V, unit V, mqflags AC,RMS
Line 156: Line 156:
| V db≈ rel
| V db≈ rel
| -48 - 63 dB
| -48 - 63 dB
| 0,01 dB
| 0.01 dB
|  
|  
| mq V, unit V, mqflags AC,RMS
| mq V, unit V, mqflags AC,RMS
Line 452: Line 452:
[[Category:Device]]
[[Category:Device]]
[[Category:Multimeter]]
[[Category:Multimeter]]
[[Category:In progress]]
[[Category:Supported]]

Latest revision as of 20:29, 21 September 2016

Gossen Metrawatt Metrahit 18S
Gossen Metrawatt Metrahit 18S small.png
Status supported
Source code gmc-mh-1x-2x
Counts 31000
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (RS232)
Measurements voltage, current, resistance, capacitance, temperature, diode, continuity
Features autorange, data hold, bargraph

The Gossen Metrawatt Metrahit 18S is a 31000 counts handheld digital multimeter with IR (RS232) connectivity.

Hardware

  • Battery: 9 V IEC 6 F 22 or IEC 6 LR 61 or corresponding rechargeable battery
  • Fuse:
    • Current 300 mA: FF (UR) 1,6 A/500G; 6,3x32 mm
    • Current 3A, 10A:
      • Siba Ultrarapid 16A/600 V≈ 10mm x 38 mm
      • Littlefuse KLK 15A/600 V≈ 13/32” / 1 1/2”
      • Bussmann KLK 15A/600 V≈ 13/32” / 1 1/2”
  • TODO.

Photos

Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 300 mV 10 μV ±(0.05% + 3) mq V, unit V, mqflags DC Input Impendance >10 GΩ
3 V 100 μV ±(0.05% + 3) "
30 V 1 mV "
300 V 10 mV "
1000 V 100 mV "
V≈ 300 mV 10 µV ±(0.5% + 30) (> 500 Digit)) mq V, unit V, mqflags AC,RMS
3 V 100 μV ±(0.5% + 30) (> 300 Digit) "
30 V 1 mV "
300 V 10 mV "
1000 V 100 mV "
V≃ 300 mV 10 μV ±(0.5% + 30) (> 500 Digit)) mq V, unit V, mqflags AC,DC,RMS
3 V 100 μV ±(0.5% + 30) (> 300 Digit) "
30 V 1 mV "
300 V 10 mV "
1000 V 100 mV "
V db≈ -48 - 63 dB 0.01 dB mq V, unit V, mqflags AC,RMS Actually 5 ranges.
V db≈ rel -48 - 63 dB 0.01 dB mq V, unit V, mqflags AC,RMS Actually 5 ranges. To activate, press yellow button in dB mode, then do second measurement. Cannot be distinguished from non-rel measurement remotely.
A=  300.00 µA 100 nA mq Curr., unit A, mqflags DC
3.0000 mA 1 µA "
30.000 mA 1 µA "
300.00 mA 10 µA "
3.0000 A 100 µA "
10.000 A 1 mA "
A≃  300.00 µA 100 nA mq Curr., unit A, mqflags AC,DC,RMS
3.0000 mA 1 µA "
30.000 mA 1 µA "
300.00 mA 10 µA "
3.0000 A 100 µA "
10.000 A 1 mA "
Ω 300.00 Ω 10 mΩ mq Res., unit Ω, mqflags -
3.0000 kΩ 100 mΩ "
30.000 kΩ 1 Ω "
300.00 kΩ 10 Ω "
3.0000 MΩ 100 Ω "
30.000 MΩ 1 kΩ "
Diode/Cont. 3.0000 V– 1 mV mq V, unit V, mqflags DC,DIODE Diode and cont. are identical on this device, just without beeper for diode.
Cap. F 3.000 nF 1 pF mq Cap., unit F, mqflags -
30.00 nF 10 pF "
300.0 nF 100 pF "
3.000 µF 1 nF "
30.00 µF 10 nF "
300.0 µF 100 nF ±(5.0% + 6) "
3.000 mF 1 µF "
10.00 mF 10 µF "
Hz≃ 300.00 Hz 0.01 Hz ±(0.1% + 3) mq Freq., unit Hz, mqflags AC,DC
3.0000 kHz 0.1 Hz "
30.000 kHz 1 Hz "
100.000 kHz 10 Hz "
°C Pt100 –200.0 - +100.0 °C 0.1 °C 2 Kelvin + 5 mq Temp., unit °C, mqflags -
Pt100 +100.0 - +800.0 °C ±(1.0% + 5) "
Pt1000 –100.0 - +100.0 °C 2 Kelvin + 5 "
Pt1000 +100.0 - +800.0 °C ±(1.0% + 5) "


Event count mq V, unit V, mqflags AC,RMS,REL Counts events >= 2500 digits that last >=2s with a break >=2s. To activate, switch to voltage ACDC, press yellow button twice. Press up to 4 times to cycle parameters, press long to stop. See manual. Not useful remotely because the current measurement value is sent, not the counter.
Stop Watch (Time data) To activate, select a 3V-1000V range manually, press yellow button, press AUTO for start/stop, DATA for reset. Delivers only invalid data ("Overflow") via IR on  Matthias' device.
Data Hold mqflags += HOLD Disabled while IR interface is active on  Matthias' device.
MIN mqflags += MIN Influences only display, via IR flag is set, but actual current value is delivered.
MAX mqflags += MAX Influences only display, via IR flag is set, but actual current value is delivered.

The column "sigrok result" contains in short form what the driver generates for the resp. data type.