<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://sigrok.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Flaviu</id>
	<title>sigrok - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://sigrok.org/w/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Flaviu"/>
	<link rel="alternate" type="text/html" href="https://sigrok.org/wiki/Special:Contributions/Flaviu"/>
	<updated>2026-04-08T14:05:44Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.37.1</generator>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16610</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16610"/>
		<updated>2023-09-30T19:27:22Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: /* Floppy Drive */ add floppy emulator details.&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
=== Links ===&lt;br /&gt;
&lt;br /&gt;
* [https://github.com/kiwih/agilent-rs232 Communicating with the osciliscope in Python to perform a waveform dump]&lt;br /&gt;
* [https://01001000.xyz/2020-05-07-Walkthrough-Agilent-Oscilloscope-RS232/ blog post explaining how the above code was written]&lt;br /&gt;
&lt;br /&gt;
== Floppy Drive ==&lt;br /&gt;
&lt;br /&gt;
The floppy drive [https://youtu.be/aVNfFewFn_Y?t=1581 is a TEAC FD-05HF.]&lt;br /&gt;
&lt;br /&gt;
The Gotek SFR1M44-DU26 USB floppy emulator is compatible once modified &amp;amp; flashed with FlashFloppy firmware. See [https://github.com/andrewpono/TDS3000-Series-Gotek-FlashFloppy TDS3000 series oscilloscope floppy drive replacement] for an overview of the process&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5464x-service-guide Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5462x-service-guide Agilent 54620-Series Service Guide]&lt;br /&gt;
* [https://web.archive.org/web/20230911223237/https://www.6thplanet.com/store/technical/pdf/Teac-FD05-Series.pdf TEAC FD-05 Datasheet]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16592</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16592"/>
		<updated>2023-09-11T22:35:12Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: /* Links */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
=== Links ===&lt;br /&gt;
&lt;br /&gt;
* [https://github.com/kiwih/agilent-rs232 Communicating with the osciliscope in Python to perform a waveform dump]&lt;br /&gt;
* [https://01001000.xyz/2020-05-07-Walkthrough-Agilent-Oscilloscope-RS232/ blog post explaining how the above code was written]&lt;br /&gt;
&lt;br /&gt;
== Floppy Drive ==&lt;br /&gt;
&lt;br /&gt;
The floppy drive [https://youtu.be/aVNfFewFn_Y?t=1581 is a TEAC FD-05HF.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5464x-service-guide Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5462x-service-guide Agilent 54620-Series Service Guide]&lt;br /&gt;
* [https://web.archive.org/web/20230911223237/https://www.6thplanet.com/store/technical/pdf/Teac-FD05-Series.pdf TEAC FD-05 Datasheet]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16591</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16591"/>
		<updated>2023-09-11T22:35:02Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: /* Protocol */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
=== Links ===&lt;br /&gt;
&lt;br /&gt;
- [https://github.com/kiwih/agilent-rs232 Communicating with the osciliscope in Python to perform a waveform dump]&lt;br /&gt;
- [https://01001000.xyz/2020-05-07-Walkthrough-Agilent-Oscilloscope-RS232/ blog post explaining how the above code was written]&lt;br /&gt;
&lt;br /&gt;
== Floppy Drive ==&lt;br /&gt;
&lt;br /&gt;
The floppy drive [https://youtu.be/aVNfFewFn_Y?t=1581 is a TEAC FD-05HF.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5464x-service-guide Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5462x-service-guide Agilent 54620-Series Service Guide]&lt;br /&gt;
* [https://web.archive.org/web/20230911223237/https://www.6thplanet.com/store/technical/pdf/Teac-FD05-Series.pdf TEAC FD-05 Datasheet]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16590</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16590"/>
		<updated>2023-09-11T22:33:25Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
== Floppy Drive ==&lt;br /&gt;
&lt;br /&gt;
The floppy drive [https://youtu.be/aVNfFewFn_Y?t=1581 is a TEAC FD-05HF.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5464x-service-guide Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5462x-service-guide Agilent 54620-Series Service Guide]&lt;br /&gt;
* [https://web.archive.org/web/20230911223237/https://www.6thplanet.com/store/technical/pdf/Teac-FD05-Series.pdf TEAC FD-05 Datasheet]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16334</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=16334"/>
		<updated>2022-09-14T01:03:01Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Update links to manuals&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://web.archive.org/web/https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5464x-service-guide Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://archive.org/details/agilent-5462x-service-guide Agilent 54620-Series Service Guide]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14047</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14047"/>
		<updated>2019-01-26T19:21:17Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_54622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=File:Agilent_5622A_Front.jpg&amp;diff=14046</id>
		<title>File:Agilent 5622A Front.jpg</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=File:Agilent_5622A_Front.jpg&amp;diff=14046"/>
		<updated>2019-01-26T19:20:56Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Flaviu moved page File:Agilent 5622A Front.jpg to File:Agilent 54622A Front.jpg: typo in filename&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;#REDIRECT [[File:Agilent 54622A Front.jpg]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14045</id>
		<title>File:Agilent 54622A Front.jpg</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14045"/>
		<updated>2019-01-26T19:20:56Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Flaviu moved page File:Agilent 5622A Front.jpg to File:Agilent 54622A Front.jpg: typo in filename&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Licensing ==&lt;br /&gt;
{{PD}}&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14044</id>
		<title>File:Agilent 54622A Front.jpg</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14044"/>
		<updated>2019-01-26T19:19:32Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Flaviu uploaded a new version of File:Agilent 5622A Front.jpg&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Licensing ==&lt;br /&gt;
{{PD}}&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14042</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14042"/>
		<updated>2019-01-26T18:40:33Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Add categories&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_5622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = Not Supported‏‎&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide.]&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Device]]&lt;br /&gt;
[[Category:Logic analyzer]]&lt;br /&gt;
[[Category:Oscilloscope]]&lt;br /&gt;
[[Category:Mixed-signal oscilloscope]]&lt;br /&gt;
[[Category:Not Supported‏‎]]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14041</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14041"/>
		<updated>2019-01-26T18:38:45Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_5622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = unsupported&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Protocol ==&lt;br /&gt;
&lt;br /&gt;
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer&amp;#039;s Guide]&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14040</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14040"/>
		<updated>2019-01-26T18:36:48Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_5622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = unsupported&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Resources ==&lt;br /&gt;
&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/5968-8152EN.pdf Agilent 54600-Series Data Sheet]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97036.pdf Agilent 54600-Series User&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf Agilent 54600-Series Programmer&amp;#039;s Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]&lt;br /&gt;
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14034</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14034"/>
		<updated>2019-01-26T16:33:37Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =  [[File:Agilent_5622A_Front.jpg|180px]]&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = unsupported&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Models ==&lt;br /&gt;
&lt;br /&gt;
{| border=&amp;quot;0&amp;quot; style=&amp;quot;font-size: smaller&amp;quot; class=&amp;quot;alternategrey sortable sigroktable&amp;quot;&lt;br /&gt;
! Model&lt;br /&gt;
! Bandwidth (Hz)&lt;br /&gt;
! Max Sample Rate (Sa/s)&lt;br /&gt;
! Memory (MB)&lt;br /&gt;
! Digital Inputs&lt;br /&gt;
! Analog Inputs&lt;br /&gt;
! Input Impedance (Ω)&lt;br /&gt;
|-&lt;br /&gt;
| 54621A&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54621D&lt;br /&gt;
| 60 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54622D&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54624A&lt;br /&gt;
| 100 M&lt;br /&gt;
| 200 M&lt;br /&gt;
| 4&lt;br /&gt;
| &lt;br /&gt;
| 4&lt;br /&gt;
| 1 M&lt;br /&gt;
|-&lt;br /&gt;
| 54641A&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54641D&lt;br /&gt;
| 350 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642A&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| &lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|-&lt;br /&gt;
| 54642D&lt;br /&gt;
| 500 M&lt;br /&gt;
| 2 G&lt;br /&gt;
| 8&lt;br /&gt;
| 16&lt;br /&gt;
| 2&lt;br /&gt;
| 1 M, 50&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14033</id>
		<title>File:Agilent 54622A Front.jpg</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=File:Agilent_54622A_Front.jpg&amp;diff=14033"/>
		<updated>2019-01-26T16:32:57Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== Licensing ==&lt;br /&gt;
{{PD}}&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
	<entry>
		<id>https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14032</id>
		<title>Agilent 54600 Series</title>
		<link rel="alternate" type="text/html" href="https://sigrok.org/w/index.php?title=Agilent_54600_Series&amp;diff=14032"/>
		<updated>2019-01-23T00:59:51Z</updated>

		<summary type="html">&lt;p&gt;Flaviu: Add infobox&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Infobox oscilloscope&lt;br /&gt;
| image               =&lt;br /&gt;
| name                = Agilent 54600 series&lt;br /&gt;
| status              = unsupported&lt;br /&gt;
| source_code_dir     = ?&lt;br /&gt;
| channels            = 2-4 analog, 16 digital (D models only)&lt;br /&gt;
| samplerate          = 200-2000MSa/s (depending on model)&lt;br /&gt;
| bandwidth           = 60-500MHz (depending on model)&lt;br /&gt;
| memory              = 4MSa-8MSa (mode/ch-dependent) (depending on model)&lt;br /&gt;
| triggers            = edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI&lt;br /&gt;
| input_impedance     = 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)&lt;br /&gt;
| vertical_resolution = 8bits&lt;br /&gt;
| display             = 7&amp;quot; raster monochrome CRT&lt;br /&gt;
| connectivity        = 3.5&amp;quot; 1.44MiB floppy, RS232, parallel port&lt;br /&gt;
| website             = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]&lt;br /&gt;
}}&lt;/div&gt;</summary>
		<author><name>Flaviu</name></author>
	</entry>
</feed>