]> sigrok.org Git - sigrok-test.git/commitdiff
modbus: Add a few flowmeter test-cases.
authorUwe Hermann <redacted>
Sun, 30 Jun 2019 21:39:18 +0000 (23:39 +0200)
committerUwe Hermann <redacted>
Sun, 30 Jun 2019 21:39:18 +0000 (23:39 +0200)
decoder/test/modbus/flowmeter_graph_tool.output [new file with mode: 0644]
decoder/test/modbus/flowmeter_target_0liter_per_min.output [new file with mode: 0644]
decoder/test/modbus/flowmeter_target_15liter_per_min.output [new file with mode: 0644]
decoder/test/modbus/flowmeter_target_20liter_per_min.output [new file with mode: 0644]
decoder/test/modbus/test.conf

diff --git a/decoder/test/modbus/flowmeter_graph_tool.output b/decoder/test/modbus/flowmeter_graph_tool.output
new file mode 100644 (file)
index 0000000..f43ef38
--- /dev/null
@@ -0,0 +1,198 @@
+16632-19966 modbus: sc-server-id: "Slave ID: 247"
+16632-19966 modbus: cs-server-id: "Slave ID: 247"
+21303-24637 modbus: sc-function: "Function 3: Read Holding Registers"
+21303-24637 modbus: cs-function: "Function 3: Read Holding Registers"
+25953-29287 modbus: sc-length: "Byte count: 0"
+25953-33958 modbus: cs-address: "Start at address 0x0 / 30001"
+30624-38608 modbus: sc-error: "CRC should be 192 194"
+35274-43280 modbus: cs-length: "Read 2 units of data"
+39946-47930 modbus: sc-error: "Message too long"
+44596-52601 modbus: cs-crc: "CRC correct"
+69493-72827 modbus: sc-server-id: "Slave ID: 247"
+69493-72827 modbus: cs-server-id: "Slave ID: 247"
+74068-77402 modbus: sc-function: "Function 3: Read Holding Registers"
+74068-77402 modbus: cs-function: "Function 3: Read Holding Registers"
+78644-81978 modbus: sc-length: "Byte count: 4"
+78644-86553 modbus: cs-address: "Start at address 0x400 / 31025"
+83219-91129 modbus: sc-data: "0x0000 / 0"
+87795-95705 modbus: cs-length: "Read 0 units of data"
+92371-100280 modbus: sc-data: "0x0000 / 0"
+96946-104856 modbus: cs-error: "CRC should be 80 108"
+101522-109431 modbus: sc-crc: "CRC correct"
+106097-109431 modbus: cs-error: "Unknown function"
+266032-269366 modbus: sc-server-id: "Slave ID: 247"
+266032-269366 modbus: cs-server-id: "Slave ID: 247"
+270702-274036 modbus: sc-function: "Function 3: Read Holding Registers"
+270702-274036 modbus: cs-function: "Function 3: Read Holding Registers"
+275352-278686 modbus: sc-length: "Byte count: 0"
+275352-283358 modbus: cs-address: "Start at address 0x6 / 30007"
+280024-288008 modbus: sc-error: "CRC should be 192 194"
+284674-292679 modbus: cs-length: "Read 2 units of data"
+289345-297329 modbus: sc-error: "Message too long"
+293995-302001 modbus: cs-crc: "CRC correct"
+318889-322223 modbus: sc-server-id: "Slave ID: 247"
+318889-322223 modbus: cs-server-id: "Slave ID: 247"
+323465-326799 modbus: sc-function: "Function 3: Read Holding Registers"
+323465-326799 modbus: cs-function: "Function 3: Read Holding Registers"
+328041-331375 modbus: sc-length: "Byte count: 4"
+328041-335950 modbus: cs-address: "Start at address 0x400 / 31025"
+332616-340526 modbus: sc-data: "0x0000 / 0"
+337192-345101 modbus: cs-length: "Read 0 units of data"
+341767-349677 modbus: sc-data: "0x0000 / 0"
+346343-354253 modbus: cs-error: "CRC should be 80 108"
+350919-358828 modbus: sc-crc: "CRC correct"
+355494-358828 modbus: cs-error: "Unknown function"
+516264-519598 modbus: sc-server-id: "Slave ID: 247"
+516264-519598 modbus: cs-server-id: "Slave ID: 247"
+520934-524268 modbus: sc-function: "Function 3: Read Holding Registers"
+520934-524268 modbus: cs-function: "Function 3: Read Holding Registers"
+525584-528918 modbus: sc-length: "Byte count: 0"
+525584-533589 modbus: cs-address: "Start at address 0xA / 30011"
+530255-538239 modbus: sc-error: "CRC should be 192 194"
+534905-542911 modbus: cs-length: "Read 2 units of data"
+539577-547561 modbus: sc-error: "Message too long"
+544227-552232 modbus: cs-crc: "CRC correct"
+569118-572452 modbus: sc-server-id: "Slave ID: 247"
+569118-572452 modbus: cs-server-id: "Slave ID: 247"
+573694-577028 modbus: sc-function: "Function 3: Read Holding Registers"
+573694-577028 modbus: cs-function: "Function 3: Read Holding Registers"
+578269-581603 modbus: sc-length: "Byte count: 4"
+578269-586179 modbus: cs-address: "Start at address 0x400 / 31025"
+582845-590755 modbus: sc-data: "0x0000 / 0"
+587421-595330 modbus: cs-length: "Read 0 units of data"
+591996-599906 modbus: sc-data: "0x0000 / 0"
+596572-604481 modbus: cs-error: "CRC should be 80 108"
+601147-609057 modbus: sc-crc: "CRC correct"
+605723-609057 modbus: cs-error: "Unknown function"
+954633-957967 modbus: sc-server-id: "Slave ID: 247"
+954633-957967 modbus: cs-server-id: "Slave ID: 247"
+959303-962637 modbus: sc-function: "Function 3: Read Holding Registers"
+959303-962637 modbus: cs-function: "Function 3: Read Holding Registers"
+963953-967287 modbus: sc-length: "Byte count: 0"
+963953-971959 modbus: cs-address: "Start at address 0x0 / 30001"
+968625-976609 modbus: sc-error: "CRC should be 192 194"
+973275-981280 modbus: cs-length: "Read 2 units of data"
+977946-985930 modbus: sc-error: "Message too long"
+982596-990602 modbus: cs-crc: "CRC correct"
+1007493-1010827 modbus: sc-server-id: "Slave ID: 247"
+1007493-1010827 modbus: cs-server-id: "Slave ID: 247"
+1012069-1015403 modbus: sc-function: "Function 3: Read Holding Registers"
+1012069-1015403 modbus: cs-function: "Function 3: Read Holding Registers"
+1016644-1019978 modbus: sc-length: "Byte count: 4"
+1016644-1024554 modbus: cs-address: "Start at address 0x400 / 31025"
+1021220-1029129 modbus: sc-data: "0x0000 / 0"
+1025795-1033705 modbus: cs-length: "Read 0 units of data"
+1030371-1038281 modbus: sc-data: "0x0000 / 0"
+1034947-1042856 modbus: cs-error: "CRC should be 80 108"
+1039522-1047432 modbus: sc-crc: "CRC correct"
+1044098-1047432 modbus: cs-error: "Unknown function"
+1203307-1206641 modbus: sc-server-id: "Slave ID: 247"
+1203307-1206641 modbus: cs-server-id: "Slave ID: 247"
+1207977-1211311 modbus: sc-function: "Function 3: Read Holding Registers"
+1207977-1211311 modbus: cs-function: "Function 3: Read Holding Registers"
+1212627-1215961 modbus: sc-length: "Byte count: 0"
+1212627-1220633 modbus: cs-address: "Start at address 0x6 / 30007"
+1217299-1225283 modbus: sc-error: "CRC should be 192 194"
+1221949-1229955 modbus: cs-length: "Read 2 units of data"
+1226621-1234605 modbus: sc-error: "Message too long"
+1231271-1239276 modbus: cs-crc: "CRC correct"
+1256162-1259496 modbus: sc-server-id: "Slave ID: 247"
+1256162-1259496 modbus: cs-server-id: "Slave ID: 247"
+1260737-1264071 modbus: sc-function: "Function 3: Read Holding Registers"
+1260737-1264071 modbus: cs-function: "Function 3: Read Holding Registers"
+1265313-1268647 modbus: sc-length: "Byte count: 4"
+1265313-1273223 modbus: cs-address: "Start at address 0x400 / 31025"
+1269889-1277798 modbus: sc-data: "0x0000 / 0"
+1274464-1282374 modbus: cs-length: "Read 0 units of data"
+1279040-1286949 modbus: sc-data: "0x0000 / 0"
+1283615-1291525 modbus: cs-error: "CRC should be 80 108"
+1288191-1296101 modbus: sc-crc: "CRC correct"
+1292767-1296101 modbus: cs-error: "Unknown function"
+1453880-1457214 modbus: sc-server-id: "Slave ID: 247"
+1453880-1457214 modbus: cs-server-id: "Slave ID: 247"
+1458550-1461884 modbus: sc-function: "Function 3: Read Holding Registers"
+1458550-1461884 modbus: cs-function: "Function 3: Read Holding Registers"
+1463200-1466534 modbus: sc-length: "Byte count: 0"
+1463200-1471206 modbus: cs-address: "Start at address 0xA / 30011"
+1467872-1475856 modbus: sc-error: "CRC should be 192 194"
+1472522-1480527 modbus: cs-length: "Read 2 units of data"
+1477193-1485177 modbus: sc-error: "Message too long"
+1481843-1489849 modbus: cs-crc: "CRC correct"
+1506728-1510062 modbus: sc-server-id: "Slave ID: 247"
+1506728-1510062 modbus: cs-server-id: "Slave ID: 247"
+1511304-1514638 modbus: sc-function: "Function 3: Read Holding Registers"
+1511304-1514638 modbus: cs-function: "Function 3: Read Holding Registers"
+1515880-1519214 modbus: sc-length: "Byte count: 4"
+1515880-1523789 modbus: cs-address: "Start at address 0x400 / 31025"
+1520455-1528365 modbus: sc-data: "0x0000 / 0"
+1525031-1532941 modbus: cs-length: "Read 0 units of data"
+1529607-1537516 modbus: sc-data: "0x0000 / 0"
+1534182-1542092 modbus: cs-error: "CRC should be 80 108"
+1538758-1546667 modbus: sc-crc: "CRC correct"
+1543333-1546667 modbus: cs-error: "Unknown function"
+1891673-1895007 modbus: sc-server-id: "Slave ID: 247"
+1891673-1895007 modbus: cs-server-id: "Slave ID: 247"
+1896343-1899677 modbus: sc-function: "Function 3: Read Holding Registers"
+1896343-1899677 modbus: cs-function: "Function 3: Read Holding Registers"
+1900994-1904328 modbus: sc-length: "Byte count: 0"
+1900994-1908999 modbus: cs-address: "Start at address 0x0 / 30001"
+1905665-1913649 modbus: sc-error: "CRC should be 192 194"
+1910315-1918321 modbus: cs-length: "Read 2 units of data"
+1914987-1922971 modbus: sc-error: "Message too long"
+1919637-1927642 modbus: cs-crc: "CRC correct"
+1944531-1947865 modbus: sc-server-id: "Slave ID: 247"
+1944531-1947865 modbus: cs-server-id: "Slave ID: 247"
+1949107-1952441 modbus: sc-function: "Function 3: Read Holding Registers"
+1949107-1952441 modbus: cs-function: "Function 3: Read Holding Registers"
+1953683-1957017 modbus: sc-length: "Byte count: 4"
+1953683-1961592 modbus: cs-address: "Start at address 0x400 / 31025"
+1958258-1966168 modbus: sc-data: "0x0000 / 0"
+1962834-1970743 modbus: cs-length: "Read 0 units of data"
+1967409-1975319 modbus: sc-data: "0x0000 / 0"
+1971985-1979895 modbus: cs-error: "CRC should be 80 108"
+1976561-1984470 modbus: sc-crc: "CRC correct"
+1981136-1984470 modbus: cs-error: "Unknown function"
+2141585-2144919 modbus: sc-server-id: "Slave ID: 247"
+2141585-2144919 modbus: cs-server-id: "Slave ID: 247"
+2146255-2149589 modbus: sc-function: "Function 3: Read Holding Registers"
+2146255-2149589 modbus: cs-function: "Function 3: Read Holding Registers"
+2150905-2154239 modbus: sc-length: "Byte count: 0"
+2150905-2158911 modbus: cs-address: "Start at address 0x6 / 30007"
+2155577-2163561 modbus: sc-error: "CRC should be 192 194"
+2160227-2168232 modbus: cs-length: "Read 2 units of data"
+2164898-2172882 modbus: sc-error: "Message too long"
+2169548-2177554 modbus: cs-crc: "CRC correct"
+2194423-2197757 modbus: sc-server-id: "Slave ID: 247"
+2194423-2197757 modbus: cs-server-id: "Slave ID: 247"
+2198998-2202332 modbus: sc-function: "Function 3: Read Holding Registers"
+2198998-2202332 modbus: cs-function: "Function 3: Read Holding Registers"
+2203573-2206907 modbus: sc-length: "Byte count: 4"
+2203573-2211483 modbus: cs-address: "Start at address 0x400 / 31025"
+2208149-2216059 modbus: sc-data: "0x0000 / 0"
+2212725-2220634 modbus: cs-length: "Read 0 units of data"
+2217300-2225210 modbus: sc-data: "0x0000 / 0"
+2221876-2229785 modbus: cs-error: "CRC should be 80 108"
+2226451-2234361 modbus: sc-crc: "CRC correct"
+2231027-2234361 modbus: cs-error: "Unknown function"
+2391134-2394468 modbus: sc-server-id: "Slave ID: 247"
+2391134-2394468 modbus: cs-server-id: "Slave ID: 247"
+2395804-2399138 modbus: sc-function: "Function 3: Read Holding Registers"
+2395804-2399138 modbus: cs-function: "Function 3: Read Holding Registers"
+2400454-2403788 modbus: sc-length: "Byte count: 0"
+2400454-2408460 modbus: cs-address: "Start at address 0xA / 30011"
+2405126-2413110 modbus: sc-error: "CRC should be 192 194"
+2409776-2417781 modbus: cs-length: "Read 2 units of data"
+2414447-2422431 modbus: sc-error: "Message too long"
+2419097-2427103 modbus: cs-crc: "CRC correct"
+2444001-2447335 modbus: sc-server-id: "Slave ID: 247"
+2444001-2447335 modbus: cs-server-id: "Slave ID: 247"
+2448577-2451911 modbus: sc-function: "Function 3: Read Holding Registers"
+2448577-2451911 modbus: cs-function: "Function 3: Read Holding Registers"
+2453152-2456486 modbus: sc-length: "Byte count: 4"
+2453152-2461062 modbus: cs-address: "Start at address 0x400 / 31025"
+2457728-2465637 modbus: sc-data: "0x0000 / 0"
+2462303-2470213 modbus: cs-length: "Read 0 units of data"
+2466879-2474789 modbus: sc-data: "0x0000 / 0"
+2471455-2479364 modbus: cs-error: "CRC should be 80 108"
+2476030-2483940 modbus: sc-crc: "CRC correct"
+2480606-2483940 modbus: cs-error: "Unknown function"
diff --git a/decoder/test/modbus/flowmeter_target_0liter_per_min.output b/decoder/test/modbus/flowmeter_target_0liter_per_min.output
new file mode 100644 (file)
index 0000000..c295054
--- /dev/null
@@ -0,0 +1,1931 @@
+15363-18697 modbus: sc-server-id: "Slave ID: 247"
+15363-18697 modbus: cs-server-id: "Slave ID: 247"
+20012-23346 modbus: sc-function: "Function 3: Read Holding Registers"
+20012-23346 modbus: cs-function: "Function 3: Read Holding Registers"
+24683-28017 modbus: sc-length: "Byte count: 0"
+24683-32667 modbus: cs-address: "Start at address 0xD / 30014"
+29333-37339 modbus: sc-error: "CRC should be 192 194"
+34005-41989 modbus: cs-length: "Read 1 units of data"
+38655-46660 modbus: sc-error: "Message too long"
+43326-51310 modbus: cs-crc: "CRC correct"
+68161-71495 modbus: sc-server-id: "Slave ID: 247"
+68161-71495 modbus: cs-server-id: "Slave ID: 247"
+72737-76071 modbus: sc-function: "Function 3: Read Holding Registers"
+72737-76071 modbus: cs-function: "Function 3: Read Holding Registers"
+77313-80647 modbus: sc-length: "Byte count: 2"
+77313-85222 modbus: cs-address: "Start at address 0x200 / 30513"
+81888-89798 modbus: sc-data: "0x0008 / 8"
+86464-94373 modbus: cs-length: "Read 2161 units of data"
+91039-98949 modbus: sc-crc: "CRC correct"
+94373-100200 modbus: cs-error: "Message too short or not finished"
+263610-266944 modbus: sc-server-id: "Slave ID: 247"
+263610-266944 modbus: cs-server-id: "Slave ID: 247"
+268259-271593 modbus: sc-function: "Function 3: Read Holding Registers"
+268259-271593 modbus: cs-function: "Function 3: Read Holding Registers"
+272931-276265 modbus: sc-length: "Byte count: 64"
+272931-280915 modbus: cs-address: "Start at address 0x4082 / 46515"
+277581-285586 modbus: sc-data: "0x8200 / 33280"
+282252-290236 modbus: cs-length: "Read 2 units of data"
+286902-294908 modbus: sc-data: "0x0265 / 613"
+291574-299558 modbus: cs-crc: "CRC correct"
+294908-300809 modbus: sc-error: "Message too short or not finished"
+318520-321854 modbus: sc-server-id: "Slave ID: 247"
+318520-321854 modbus: cs-server-id: "Slave ID: 247"
+323096-326430 modbus: sc-function: "Function 3: Read Holding Registers"
+323096-326430 modbus: cs-function: "Function 3: Read Holding Registers"
+327671-331005 modbus: sc-length: "Byte count: 4"
+327671-335581 modbus: cs-address: "Start at address 0x400 / 31025"
+332247-340157 modbus: sc-data: "0x0000 / 0"
+336823-344732 modbus: cs-length: "Read 0 units of data"
+341398-349308 modbus: sc-data: "0x0003 / 3"
+345974-353883 modbus: cs-error: "CRC should be 80 108"
+350549-358459 modbus: sc-crc: "CRC correct"
+355125-358459 modbus: cs-error: "Unknown function"
+523270-526604 modbus: sc-server-id: "Slave ID: 247"
+523270-526604 modbus: cs-server-id: "Slave ID: 247"
+527919-531253 modbus: sc-function: "Function 3: Read Holding Registers"
+527919-531253 modbus: cs-function: "Function 3: Read Holding Registers"
+532591-535925 modbus: sc-length: "Byte count: 0"
+532591-540575 modbus: cs-address: "Start at address 0x0 / 30001"
+537241-545246 modbus: sc-error: "CRC should be 192 194"
+541912-549896 modbus: cs-length: "Read 15 units of data"
+546562-554568 modbus: sc-error: "Message too long"
+551234-559218 modbus: cs-crc: "CRC correct"
+576418-579752 modbus: sc-server-id: "Slave ID: 247"
+576418-579752 modbus: cs-server-id: "Slave ID: 247"
+580994-584328 modbus: sc-function: "Function 3: Read Holding Registers"
+580994-584328 modbus: cs-function: "Function 3: Read Holding Registers"
+585569-588903 modbus: sc-length: "Byte count: 30"
+585569-593479 modbus: cs-address: "Start at address 0x1E00 / 37681"
+590145-598055 modbus: sc-data: "0x0000 / 0"
+594721-602630 modbus: cs-length: "Read 0 units of data"
+599296-607206 modbus: sc-data: "0x0000 / 0"
+603872-611781 modbus: cs-error: "CRC should be 87 116"
+608447-616357 modbus: sc-data: "0x41B7 / 16823"
+613023-616357 modbus: cs-error: "Unknown function"
+617599-620933 modbus: cs-error: "Unknown function"
+617599-625508 modbus: sc-data: "0xC6FC / 50940"
+622174-625508 modbus: cs-error: "Unknown function"
+626750-630084 modbus: cs-error: "Unknown function"
+626750-634659 modbus: sc-data: "0x3E57 / 15959"
+631325-634659 modbus: cs-error: "Unknown function"
+635901-639235 modbus: cs-error: "Unknown function"
+635901-643811 modbus: sc-data: "0x9E9F / 40607"
+640477-643811 modbus: cs-error: "Unknown function"
+645052-648386 modbus: cs-error: "Unknown function"
+645052-652962 modbus: sc-data: "0x41A0 / 16800"
+649628-652962 modbus: cs-error: "Unknown function"
+654204-657538 modbus: cs-error: "Unknown function"
+654204-662113 modbus: sc-data: "0x0000 / 0"
+658779-662113 modbus: cs-error: "Unknown function"
+663355-666689 modbus: cs-error: "Unknown function"
+663355-671264 modbus: sc-data: "0x3AC3 / 15043"
+667930-671264 modbus: cs-error: "Unknown function"
+672506-675840 modbus: cs-error: "Unknown function"
+672506-680416 modbus: sc-data: "0x0FB5 / 4021"
+677082-680416 modbus: cs-error: "Unknown function"
+681657-684991 modbus: cs-error: "Unknown function"
+681657-689567 modbus: sc-data: "0x0000 / 0"
+686233-689567 modbus: cs-error: "Unknown function"
+690808-694142 modbus: cs-error: "Unknown function"
+690808-698718 modbus: sc-data: "0x0000 / 0"
+695384-698718 modbus: cs-error: "Unknown function"
+699960-703294 modbus: cs-error: "Unknown function"
+699960-707869 modbus: sc-data: "0x8000 / 32768"
+704535-707869 modbus: cs-error: "Unknown function"
+709111-712445 modbus: cs-error: "Unknown function"
+709111-717020 modbus: sc-data: "0x0008 / 8"
+713686-717020 modbus: cs-error: "Unknown function"
+718262-721596 modbus: cs-error: "Unknown function"
+718262-726172 modbus: sc-data: "0x0000 / 0"
+722838-726172 modbus: cs-error: "Unknown function"
+727413-730747 modbus: cs-error: "Unknown function"
+727413-735323 modbus: sc-crc: "CRC correct"
+731989-735323 modbus: cs-error: "Unknown function"
+889584-892918 modbus: sc-server-id: "Slave ID: 247"
+889584-892918 modbus: cs-server-id: "Slave ID: 247"
+894233-897567 modbus: sc-function: "Function 3: Read Holding Registers"
+894233-897567 modbus: cs-function: "Function 3: Read Holding Registers"
+898905-902239 modbus: sc-length: "Byte count: 0"
+898905-906889 modbus: cs-address: "Start at address 0xD / 30014"
+903555-911560 modbus: sc-error: "CRC should be 192 194"
+908226-916210 modbus: cs-length: "Read 1 units of data"
+912876-920882 modbus: sc-error: "Message too long"
+917548-925532 modbus: cs-crc: "CRC correct"
+942389-945723 modbus: sc-server-id: "Slave ID: 247"
+942389-945723 modbus: cs-server-id: "Slave ID: 247"
+946965-950299 modbus: sc-function: "Function 3: Read Holding Registers"
+946965-950299 modbus: cs-function: "Function 3: Read Holding Registers"
+951540-954874 modbus: sc-length: "Byte count: 2"
+951540-959450 modbus: cs-address: "Start at address 0x200 / 30513"
+956116-964026 modbus: sc-data: "0x0008 / 8"
+960692-968601 modbus: cs-length: "Read 2161 units of data"
+965267-973177 modbus: sc-crc: "CRC correct"
+968601-974428 modbus: cs-error: "Message too short or not finished"
+1138749-1142083 modbus: sc-server-id: "Slave ID: 247"
+1138749-1142083 modbus: cs-server-id: "Slave ID: 247"
+1143398-1146732 modbus: sc-function: "Function 3: Read Holding Registers"
+1143398-1146732 modbus: cs-function: "Function 3: Read Holding Registers"
+1148070-1151404 modbus: sc-length: "Byte count: 64"
+1148070-1156054 modbus: cs-address: "Start at address 0x4082 / 46515"
+1152720-1160725 modbus: sc-data: "0x8200 / 33280"
+1157391-1165376 modbus: cs-length: "Read 2 units of data"
+1162042-1170047 modbus: sc-data: "0x0265 / 613"
+1166713-1174697 modbus: cs-crc: "CRC correct"
+1170047-1175948 modbus: sc-error: "Message too short or not finished"
+1193632-1196966 modbus: sc-server-id: "Slave ID: 247"
+1193632-1196966 modbus: cs-server-id: "Slave ID: 247"
+1198207-1201541 modbus: sc-function: "Function 3: Read Holding Registers"
+1198207-1201541 modbus: cs-function: "Function 3: Read Holding Registers"
+1202783-1206117 modbus: sc-length: "Byte count: 4"
+1202783-1210693 modbus: cs-address: "Start at address 0x400 / 31025"
+1207359-1215268 modbus: sc-data: "0x0000 / 0"
+1211934-1219844 modbus: cs-length: "Read 0 units of data"
+1216510-1224419 modbus: sc-data: "0x0003 / 3"
+1221085-1228995 modbus: cs-error: "CRC should be 80 108"
+1225661-1233571 modbus: sc-crc: "CRC correct"
+1230237-1233571 modbus: cs-error: "Unknown function"
+1398239-1401573 modbus: sc-server-id: "Slave ID: 247"
+1398239-1401573 modbus: cs-server-id: "Slave ID: 247"
+1402888-1406222 modbus: sc-function: "Function 3: Read Holding Registers"
+1402888-1406222 modbus: cs-function: "Function 3: Read Holding Registers"
+1407559-1410893 modbus: sc-length: "Byte count: 0"
+1407559-1415543 modbus: cs-address: "Start at address 0x0 / 30001"
+1412209-1420215 modbus: sc-error: "CRC should be 192 194"
+1416881-1424865 modbus: cs-length: "Read 15 units of data"
+1421531-1429536 modbus: sc-error: "Message too long"
+1426202-1434186 modbus: cs-crc: "CRC correct"
+1453116-1456450 modbus: sc-server-id: "Slave ID: 247"
+1453116-1456450 modbus: cs-server-id: "Slave ID: 247"
+1457691-1461025 modbus: sc-function: "Function 3: Read Holding Registers"
+1457691-1461025 modbus: cs-function: "Function 3: Read Holding Registers"
+1462267-1465601 modbus: sc-length: "Byte count: 30"
+1462267-1470176 modbus: cs-address: "Start at address 0x1E00 / 37681"
+1466842-1474752 modbus: sc-data: "0x0000 / 0"
+1471418-1479328 modbus: cs-length: "Read 0 units of data"
+1475994-1483903 modbus: sc-data: "0x0000 / 0"
+1480569-1488479 modbus: cs-error: "CRC should be 87 116"
+1485145-1493055 modbus: sc-data: "0x41B7 / 16823"
+1489721-1493055 modbus: cs-error: "Unknown function"
+1494296-1497630 modbus: cs-error: "Unknown function"
+1494296-1502206 modbus: sc-data: "0xC6FC / 50940"
+1498872-1502206 modbus: cs-error: "Unknown function"
+1503447-1506781 modbus: cs-error: "Unknown function"
+1503447-1511357 modbus: sc-data: "0x3E57 / 15959"
+1508023-1511357 modbus: cs-error: "Unknown function"
+1512599-1515933 modbus: cs-error: "Unknown function"
+1512599-1520508 modbus: sc-data: "0x9E9F / 40607"
+1517174-1520508 modbus: cs-error: "Unknown function"
+1521750-1525084 modbus: cs-error: "Unknown function"
+1521750-1529659 modbus: sc-data: "0x41A0 / 16800"
+1526325-1529659 modbus: cs-error: "Unknown function"
+1530901-1534235 modbus: cs-error: "Unknown function"
+1530901-1538811 modbus: sc-data: "0x0000 / 0"
+1535477-1538811 modbus: cs-error: "Unknown function"
+1540052-1543386 modbus: cs-error: "Unknown function"
+1540052-1547962 modbus: sc-data: "0x3AC3 / 15043"
+1544628-1547962 modbus: cs-error: "Unknown function"
+1549204-1552538 modbus: cs-error: "Unknown function"
+1549204-1557113 modbus: sc-data: "0x0FB5 / 4021"
+1553779-1557113 modbus: cs-error: "Unknown function"
+1558355-1561689 modbus: cs-error: "Unknown function"
+1558355-1566264 modbus: sc-data: "0x0000 / 0"
+1562930-1566264 modbus: cs-error: "Unknown function"
+1567506-1570840 modbus: cs-error: "Unknown function"
+1567506-1575416 modbus: sc-data: "0x0000 / 0"
+1572082-1575416 modbus: cs-error: "Unknown function"
+1576657-1579991 modbus: cs-error: "Unknown function"
+1576657-1584567 modbus: sc-data: "0x8000 / 32768"
+1581233-1584567 modbus: cs-error: "Unknown function"
+1585808-1589142 modbus: cs-error: "Unknown function"
+1585808-1593718 modbus: sc-data: "0x0008 / 8"
+1590384-1593718 modbus: cs-error: "Unknown function"
+1594960-1598294 modbus: cs-error: "Unknown function"
+1594960-1602869 modbus: sc-data: "0x0000 / 0"
+1599535-1602869 modbus: cs-error: "Unknown function"
+1604111-1607445 modbus: cs-error: "Unknown function"
+1604111-1612020 modbus: sc-crc: "CRC correct"
+1608686-1612020 modbus: cs-error: "Unknown function"
+1765321-1768655 modbus: sc-server-id: "Slave ID: 247"
+1765321-1768655 modbus: cs-server-id: "Slave ID: 247"
+1769969-1773303 modbus: sc-function: "Function 3: Read Holding Registers"
+1769969-1773303 modbus: cs-function: "Function 3: Read Holding Registers"
+1774641-1777975 modbus: sc-length: "Byte count: 0"
+1774641-1782625 modbus: cs-address: "Start at address 0xD / 30014"
+1779291-1787296 modbus: sc-error: "CRC should be 192 194"
+1783962-1791947 modbus: cs-length: "Read 1 units of data"
+1788613-1796618 modbus: sc-error: "Message too long"
+1793284-1801268 modbus: cs-crc: "CRC correct"
+1818124-1821458 modbus: sc-server-id: "Slave ID: 247"
+1818124-1821458 modbus: cs-server-id: "Slave ID: 247"
+1822700-1826034 modbus: sc-function: "Function 3: Read Holding Registers"
+1822700-1826034 modbus: cs-function: "Function 3: Read Holding Registers"
+1827276-1830610 modbus: sc-length: "Byte count: 2"
+1827276-1835186 modbus: cs-address: "Start at address 0x200 / 30513"
+1831852-1839761 modbus: sc-data: "0x0008 / 8"
+1836427-1844337 modbus: cs-length: "Read 2161 units of data"
+1841003-1848912 modbus: sc-crc: "CRC correct"
+1844337-1850163 modbus: cs-error: "Message too short or not finished"
+2013654-2016988 modbus: sc-server-id: "Slave ID: 247"
+2013654-2016988 modbus: cs-server-id: "Slave ID: 247"
+2018303-2021637 modbus: sc-function: "Function 3: Read Holding Registers"
+2018303-2021637 modbus: cs-function: "Function 3: Read Holding Registers"
+2022974-2026308 modbus: sc-length: "Byte count: 64"
+2022974-2030958 modbus: cs-address: "Start at address 0x4082 / 46515"
+2027624-2035630 modbus: sc-data: "0x8200 / 33280"
+2032296-2040280 modbus: cs-length: "Read 2 units of data"
+2036946-2044951 modbus: sc-data: "0x0265 / 613"
+2041617-2049601 modbus: cs-crc: "CRC correct"
+2044951-2050852 modbus: sc-error: "Message too short or not finished"
+2068535-2071869 modbus: sc-server-id: "Slave ID: 247"
+2068535-2071869 modbus: cs-server-id: "Slave ID: 247"
+2073111-2076445 modbus: sc-function: "Function 3: Read Holding Registers"
+2073111-2076445 modbus: cs-function: "Function 3: Read Holding Registers"
+2077687-2081021 modbus: sc-length: "Byte count: 4"
+2077687-2085596 modbus: cs-address: "Start at address 0x400 / 31025"
+2082262-2090172 modbus: sc-data: "0x0000 / 0"
+2086838-2094747 modbus: cs-length: "Read 0 units of data"
+2091413-2099323 modbus: sc-data: "0x0003 / 3"
+2095989-2103899 modbus: cs-error: "CRC should be 80 108"
+2100565-2108474 modbus: sc-crc: "CRC correct"
+2105140-2108474 modbus: cs-error: "Unknown function"
+2287797-2291131 modbus: sc-server-id: "Slave ID: 247"
+2287797-2291131 modbus: cs-server-id: "Slave ID: 247"
+2292446-2295780 modbus: sc-function: "Function 3: Read Holding Registers"
+2292446-2295780 modbus: cs-function: "Function 3: Read Holding Registers"
+2297118-2300452 modbus: sc-length: "Byte count: 0"
+2297118-2305102 modbus: cs-address: "Start at address 0x0 / 30001"
+2301768-2309773 modbus: sc-error: "CRC should be 192 194"
+2306439-2314423 modbus: cs-length: "Read 15 units of data"
+2311089-2319095 modbus: sc-error: "Message too long"
+2315761-2323745 modbus: cs-crc: "CRC correct"
+2340940-2344274 modbus: sc-server-id: "Slave ID: 247"
+2340940-2344274 modbus: cs-server-id: "Slave ID: 247"
+2345516-2348850 modbus: sc-function: "Function 3: Read Holding Registers"
+2345516-2348850 modbus: cs-function: "Function 3: Read Holding Registers"
+2350091-2353425 modbus: sc-length: "Byte count: 30"
+2350091-2358001 modbus: cs-address: "Start at address 0x1E00 / 37681"
+2354667-2362577 modbus: sc-data: "0x0000 / 0"
+2359243-2367152 modbus: cs-length: "Read 0 units of data"
+2363818-2371728 modbus: sc-data: "0x0000 / 0"
+2368394-2376304 modbus: cs-error: "CRC should be 87 116"
+2372970-2380879 modbus: sc-data: "0x41B7 / 16823"
+2377545-2380879 modbus: cs-error: "Unknown function"
+2382121-2385455 modbus: cs-error: "Unknown function"
+2382121-2390030 modbus: sc-data: "0xC6FC / 50940"
+2386696-2390030 modbus: cs-error: "Unknown function"
+2391272-2394606 modbus: cs-error: "Unknown function"
+2391272-2399182 modbus: sc-data: "0x3E57 / 15959"
+2395848-2399182 modbus: cs-error: "Unknown function"
+2400423-2403757 modbus: cs-error: "Unknown function"
+2400423-2408333 modbus: sc-data: "0x9E9F / 40607"
+2404999-2408333 modbus: cs-error: "Unknown function"
+2409574-2412908 modbus: cs-error: "Unknown function"
+2409574-2417484 modbus: sc-data: "0x41A0 / 16800"
+2414150-2417484 modbus: cs-error: "Unknown function"
+2418726-2422060 modbus: cs-error: "Unknown function"
+2418726-2426635 modbus: sc-data: "0x0000 / 0"
+2423301-2426635 modbus: cs-error: "Unknown function"
+2427877-2431211 modbus: cs-error: "Unknown function"
+2427877-2435786 modbus: sc-data: "0x0000 / 0"
+2432452-2435786 modbus: cs-error: "Unknown function"
+2437028-2440362 modbus: cs-error: "Unknown function"
+2437028-2444938 modbus: sc-data: "0x0000 / 0"
+2441604-2444938 modbus: cs-error: "Unknown function"
+2446179-2449513 modbus: cs-error: "Unknown function"
+2446179-2454089 modbus: sc-data: "0x0000 / 0"
+2450755-2454089 modbus: cs-error: "Unknown function"
+2455331-2458665 modbus: cs-error: "Unknown function"
+2455331-2463240 modbus: sc-data: "0x0000 / 0"
+2459906-2463240 modbus: cs-error: "Unknown function"
+2464482-2467816 modbus: cs-error: "Unknown function"
+2464482-2472391 modbus: sc-data: "0x8000 / 32768"
+2469057-2472391 modbus: cs-error: "Unknown function"
+2473633-2476967 modbus: cs-error: "Unknown function"
+2473633-2481543 modbus: sc-data: "0x0008 / 8"
+2478209-2481543 modbus: cs-error: "Unknown function"
+2482784-2486118 modbus: cs-error: "Unknown function"
+2482784-2490694 modbus: sc-data: "0x0000 / 0"
+2487360-2490694 modbus: cs-error: "Unknown function"
+2491935-2495269 modbus: cs-error: "Unknown function"
+2491935-2499845 modbus: sc-crc: "CRC correct"
+2496511-2499845 modbus: cs-error: "Unknown function"
+2704004-2707338 modbus: sc-server-id: "Slave ID: 247"
+2704004-2707338 modbus: cs-server-id: "Slave ID: 247"
+2708653-2711987 modbus: sc-function: "Function 3: Read Holding Registers"
+2708653-2711987 modbus: cs-function: "Function 3: Read Holding Registers"
+2713324-2716658 modbus: sc-length: "Byte count: 0"
+2713324-2721308 modbus: cs-address: "Start at address 0xD / 30014"
+2717974-2725980 modbus: sc-error: "CRC should be 192 194"
+2722646-2730630 modbus: cs-length: "Read 1 units of data"
+2727296-2735302 modbus: sc-error: "Message too long"
+2731968-2739952 modbus: cs-crc: "CRC correct"
+2756801-2760135 modbus: sc-server-id: "Slave ID: 247"
+2756801-2760135 modbus: cs-server-id: "Slave ID: 247"
+2761377-2764711 modbus: sc-function: "Function 3: Read Holding Registers"
+2761377-2764711 modbus: cs-function: "Function 3: Read Holding Registers"
+2765952-2769286 modbus: sc-length: "Byte count: 2"
+2765952-2773862 modbus: cs-address: "Start at address 0x200 / 30513"
+2770528-2778437 modbus: sc-data: "0x0008 / 8"
+2775103-2783013 modbus: cs-length: "Read 2161 units of data"
+2779679-2787589 modbus: sc-crc: "CRC correct"
+2783013-2788840 modbus: cs-error: "Message too short or not finished"
+2951100-2954434 modbus: sc-server-id: "Slave ID: 247"
+2951100-2954434 modbus: cs-server-id: "Slave ID: 247"
+2955749-2959083 modbus: sc-function: "Function 3: Read Holding Registers"
+2955749-2959083 modbus: cs-function: "Function 3: Read Holding Registers"
+2960420-2963754 modbus: sc-length: "Byte count: 64"
+2960420-2968404 modbus: cs-address: "Start at address 0x4082 / 46515"
+2965070-2973076 modbus: sc-data: "0x8200 / 33280"
+2969742-2977726 modbus: cs-length: "Read 2 units of data"
+2974392-2982397 modbus: sc-data: "0x0265 / 613"
+2979063-2987047 modbus: cs-crc: "CRC correct"
+2982397-2988298 modbus: sc-error: "Message too short or not finished"
+3005989-3009323 modbus: sc-server-id: "Slave ID: 247"
+3005989-3009323 modbus: cs-server-id: "Slave ID: 247"
+3010565-3013899 modbus: sc-function: "Function 3: Read Holding Registers"
+3010565-3013899 modbus: cs-function: "Function 3: Read Holding Registers"
+3015141-3018475 modbus: sc-length: "Byte count: 4"
+3015141-3023051 modbus: cs-address: "Start at address 0x400 / 31025"
+3019717-3027626 modbus: sc-data: "0x0000 / 0"
+3024292-3032202 modbus: cs-length: "Read 0 units of data"
+3028868-3036777 modbus: sc-data: "0x0003 / 3"
+3033443-3041353 modbus: cs-error: "CRC should be 80 108"
+3038019-3045929 modbus: sc-crc: "CRC correct"
+3042595-3045929 modbus: cs-error: "Unknown function"
+3207539-3210873 modbus: sc-server-id: "Slave ID: 247"
+3207539-3210873 modbus: cs-server-id: "Slave ID: 247"
+3212188-3215522 modbus: sc-function: "Function 3: Read Holding Registers"
+3212188-3215522 modbus: cs-function: "Function 3: Read Holding Registers"
+3216859-3220193 modbus: sc-length: "Byte count: 64"
+3216859-3224843 modbus: cs-address: "Start at address 0x4082 / 46515"
+3221509-3229515 modbus: sc-data: "0x8200 / 33280"
+3226181-3234165 modbus: cs-length: "Read 2 units of data"
+3230831-3238836 modbus: sc-data: "0x0265 / 613"
+3235502-3243487 modbus: cs-crc: "CRC correct"
+3238836-3244738 modbus: sc-error: "Message too short or not finished"
+3262432-3265766 modbus: sc-server-id: "Slave ID: 247"
+3262432-3265766 modbus: cs-server-id: "Slave ID: 247"
+3267008-3270342 modbus: sc-function: "Function 3: Read Holding Registers"
+3267008-3270342 modbus: cs-function: "Function 3: Read Holding Registers"
+3271583-3274917 modbus: sc-length: "Byte count: 4"
+3271583-3279493 modbus: cs-address: "Start at address 0x400 / 31025"
+3276159-3284068 modbus: sc-data: "0x0000 / 0"
+3280734-3288644 modbus: cs-length: "Read 0 units of data"
+3285310-3293220 modbus: sc-data: "0x0003 / 3"
+3289886-3297795 modbus: cs-error: "CRC should be 80 108"
+3294461-3302371 modbus: sc-crc: "CRC correct"
+3299037-3302371 modbus: cs-error: "Unknown function"
+3451670-3455004 modbus: sc-server-id: "Slave ID: 247"
+3451670-3455004 modbus: cs-server-id: "Slave ID: 247"
+3456319-3459653 modbus: sc-function: "Function 16: Write Multiple Registers"
+3456319-3459653 modbus: cs-function: "Function 16: Write Multiple Registers"
+3460990-3468974 modbus: sc-address: "Start at address 0x6 / 30007"
+3460990-3468974 modbus: cs-address: "Start at address 0x6 / 30007"
+3470312-3478296 modbus: sc-data: "Write 2 Registers"
+3470312-3478296 modbus: cs-length: "Write 2 Registers"
+3479633-3482967 modbus: cs-length: "Byte count: 4"
+3479633-3487617 modbus: sc-error: "CRC should be 181 95"
+3484283-3487617 modbus: cs-data: "Value 0x0"
+3488955-3492289 modbus: sc-error: "Message too long"
+3488955-3492289 modbus: cs-data: "Value 0x0"
+3493605-3496939 modbus: sc-error: "Message too long"
+3493605-3496939 modbus: cs-data: "Value 0x0"
+3498277-3501611 modbus: sc-error: "Message too long"
+3498277-3501611 modbus: cs-data: "Value 0x0"
+3502927-3506261 modbus: sc-error: "Message too long"
+3507598-3510932 modbus: sc-error: "Message too long"
+3502927-3510932 modbus: cs-crc: "CRC correct"
+3527896-3531230 modbus: sc-server-id: "Slave ID: 247"
+3527896-3531230 modbus: cs-server-id: "Slave ID: 247"
+3532471-3535805 modbus: sc-function: "Function 16: Write Multiple Registers"
+3532471-3535805 modbus: cs-function: "Function 16: Write Multiple Registers"
+3537047-3544956 modbus: sc-address: "Start at address 0x6 / 30007"
+3537047-3544956 modbus: cs-address: "Start at address 0x6 / 30007"
+3546198-3554107 modbus: sc-data: "Write 2 Registers"
+3546198-3554107 modbus: cs-length: "Write 2 Registers"
+3555349-3558683 modbus: cs-error: "Bad byte count, is 181, should be 4"
+3555349-3563259 modbus: sc-crc: "CRC correct"
+3559925-3563259 modbus: cs-data: "Value 0x5F"
+3893026-3896360 modbus: sc-server-id: "Slave ID: 247"
+3893026-3896360 modbus: cs-server-id: "Slave ID: 247"
+3897696-3901030 modbus: sc-function: "Function 3: Read Holding Registers"
+3897696-3901030 modbus: cs-function: "Function 3: Read Holding Registers"
+3902346-3905680 modbus: sc-error: "Error: Odd byte count (65)"
+3902346-3910351 modbus: cs-address: "Start at address 0x4139 / 46698"
+3907017-3915002 modbus: sc-data: "0x3900 / 14592"
+3911668-3919673 modbus: cs-length: "Read 1 units of data"
+3916339-3924323 modbus: sc-data: "0x0154 / 340"
+3920989-3928995 modbus: cs-crc: "CRC correct"
+3924323-3930246 modbus: sc-error: "Message too short or not finished"
+3945862-3949196 modbus: sc-server-id: "Slave ID: 247"
+3945862-3949196 modbus: cs-server-id: "Slave ID: 247"
+3950438-3953772 modbus: sc-function: "Function 3: Read Holding Registers"
+3950438-3953772 modbus: cs-function: "Function 3: Read Holding Registers"
+3955013-3958347 modbus: sc-length: "Byte count: 2"
+3955013-3962923 modbus: cs-address: "Start at address 0x200 / 30513"
+3959589-3967498 modbus: sc-data: "0x0002 / 2"
+3964164-3972074 modbus: cs-length: "Read 753 units of data"
+3968740-3976650 modbus: sc-crc: "CRC correct"
+3972074-3977901 modbus: cs-error: "Message too short or not finished"
+4138586-4141920 modbus: sc-server-id: "Slave ID: 247"
+4138586-4141920 modbus: cs-server-id: "Slave ID: 247"
+4143256-4146590 modbus: sc-function: "Function 6: Write Single Register"
+4143256-4146590 modbus: cs-function: "Function 6: Write Single Register"
+4147906-4155912 modbus: sc-address: "Address 0x5FFF / 54575"
+4147906-4155912 modbus: cs-address: "Address 0x5FFF / 54575"
+4157228-4165233 modbus: sc-data: "Register Value 0x2 / 2"
+4157228-4165233 modbus: cs-data: "Register Value 0x2 / 2"
+4166549-4174555 modbus: sc-crc: "CRC correct"
+4166549-4174555 modbus: cs-crc: "CRC correct"
+4217201-4220535 modbus: sc-server-id: "Slave ID: 247"
+4217201-4220535 modbus: cs-server-id: "Slave ID: 247"
+4221777-4225111 modbus: sc-function: "Function 6: Write Single Register"
+4221777-4225111 modbus: cs-function: "Function 6: Write Single Register"
+4226352-4234262 modbus: sc-address: "Address 0x5FFF / 54575"
+4226352-4234262 modbus: cs-address: "Address 0x5FFF / 54575"
+4235503-4243413 modbus: sc-data: "Register Value 0x2 / 2"
+4235503-4243413 modbus: cs-data: "Register Value 0x2 / 2"
+4244655-4252564 modbus: sc-crc: "CRC correct"
+4244655-4252564 modbus: cs-crc: "CRC correct"
+4389735-4393069 modbus: sc-server-id: "Slave ID: 247"
+4389735-4393069 modbus: cs-server-id: "Slave ID: 247"
+4394405-4397739 modbus: sc-function: "Function 3: Read Holding Registers"
+4394405-4397739 modbus: cs-function: "Function 3: Read Holding Registers"
+4399055-4402389 modbus: sc-length: "Byte count: 80"
+4399055-4407060 modbus: cs-address: "Start at address 0x5000 / 50481"
+4403726-4411711 modbus: sc-data: "0x0000 / 0"
+4408377-4416382 modbus: cs-length: "Read 25 units of data"
+4413048-4421032 modbus: sc-data: "0x1981 / 6529"
+4417698-4425704 modbus: cs-crc: "CRC correct"
+4421032-4426955 modbus: sc-error: "Message too short or not finished"
+4468964-4472298 modbus: sc-server-id: "Slave ID: 247"
+4468964-4472298 modbus: cs-server-id: "Slave ID: 247"
+4473539-4476873 modbus: sc-function: "Function 3: Read Holding Registers"
+4473539-4476873 modbus: cs-function: "Function 3: Read Holding Registers"
+4478115-4481449 modbus: sc-length: "Byte count: 50"
+4478115-4486024 modbus: cs-address: "Start at address 0x3200 / 42801"
+4482690-4490600 modbus: sc-data: "0x0000 / 0"
+4487266-4495176 modbus: cs-length: "Read 196 units of data"
+4491842-4499751 modbus: sc-data: "0xC420 / 50208"
+4496417-4504327 modbus: cs-error: "CRC should be 94 119"
+4500993-4508902 modbus: sc-data: "0x4000 / 16384"
+4505568-4508902 modbus: cs-error: "Unknown function"
+4510144-4513478 modbus: cs-error: "Unknown function"
+4510144-4518054 modbus: sc-data: "0x0504 / 1284"
+4514720-4518054 modbus: cs-error: "Unknown function"
+4519295-4522629 modbus: cs-error: "Unknown function"
+4519295-4527205 modbus: sc-data: "0x0000 / 0"
+4523871-4527205 modbus: cs-error: "Unknown function"
+4528446-4531780 modbus: cs-error: "Unknown function"
+4528446-4536356 modbus: sc-data: "0xFCFF / 64767"
+4533022-4536356 modbus: cs-error: "Unknown function"
+4537598-4540932 modbus: cs-error: "Unknown function"
+4537598-4545507 modbus: sc-data: "0xFFFF / 65535"
+4542173-4545507 modbus: cs-error: "Unknown function"
+4546749-4550083 modbus: cs-error: "Unknown function"
+4546749-4554658 modbus: sc-data: "0x0000 / 0"
+4551324-4554658 modbus: cs-error: "Unknown function"
+4555900-4559234 modbus: cs-error: "Unknown function"
+4555900-4563810 modbus: sc-data: "0x0000 / 0"
+4560476-4563810 modbus: cs-error: "Unknown function"
+4565051-4568385 modbus: cs-error: "Unknown function"
+4565051-4572961 modbus: sc-data: "0x0000 / 0"
+4569627-4572961 modbus: cs-error: "Unknown function"
+4574202-4577536 modbus: cs-error: "Unknown function"
+4574202-4582112 modbus: sc-data: "0x0000 / 0"
+4578778-4582112 modbus: cs-error: "Unknown function"
+4583354-4586688 modbus: cs-error: "Unknown function"
+4583354-4591263 modbus: sc-data: "0xD8FF / 55551"
+4587929-4591263 modbus: cs-error: "Unknown function"
+4592505-4595839 modbus: cs-error: "Unknown function"
+4592505-4600415 modbus: sc-data: "0xFFFF / 65535"
+4597081-4600415 modbus: cs-error: "Unknown function"
+4601656-4604990 modbus: cs-error: "Unknown function"
+4601656-4609566 modbus: sc-data: "0x0000 / 0"
+4606232-4609566 modbus: cs-error: "Unknown function"
+4610807-4614141 modbus: cs-error: "Unknown function"
+4610807-4618717 modbus: sc-data: "0x0500 / 1280"
+4615383-4618717 modbus: cs-error: "Unknown function"
+4619959-4623293 modbus: cs-error: "Unknown function"
+4619959-4627868 modbus: sc-data: "0x0000 / 0"
+4624534-4627868 modbus: cs-error: "Unknown function"
+4629110-4632444 modbus: cs-error: "Unknown function"
+4629110-4637019 modbus: sc-data: "0x0000 / 0"
+4633685-4637019 modbus: cs-error: "Unknown function"
+4638261-4641595 modbus: cs-error: "Unknown function"
+4638261-4646171 modbus: sc-data: "0x40DD / 16605"
+4642837-4646171 modbus: cs-error: "Unknown function"
+4647412-4650746 modbus: cs-error: "Unknown function"
+4647412-4655322 modbus: sc-data: "0x4300 / 17152"
+4651988-4655322 modbus: cs-error: "Unknown function"
+4656564-4659898 modbus: cs-error: "Unknown function"
+4656564-4664473 modbus: sc-data: "0x201B / 8219"
+4661139-4664473 modbus: cs-error: "Unknown function"
+4665715-4669049 modbus: cs-error: "Unknown function"
+4665715-4673624 modbus: sc-data: "0x4000 / 16384"
+4670290-4673624 modbus: cs-error: "Unknown function"
+4674866-4678200 modbus: cs-error: "Unknown function"
+4674866-4682776 modbus: sc-data: "0x0400 / 1024"
+4679442-4682776 modbus: cs-error: "Unknown function"
+4684017-4687351 modbus: cs-error: "Unknown function"
+4684017-4691927 modbus: sc-data: "0x0000 / 0"
+4688593-4691927 modbus: cs-error: "Unknown function"
+4693168-4696502 modbus: cs-error: "Unknown function"
+4693168-4701078 modbus: sc-data: "0xFCFF / 64767"
+4697744-4701078 modbus: cs-error: "Unknown function"
+4702320-4705654 modbus: cs-error: "Unknown function"
+4702320-4710229 modbus: sc-data: "0xFFFF / 65535"
+4706895-4710229 modbus: cs-error: "Unknown function"
+4711471-4714805 modbus: cs-error: "Unknown function"
+4711471-4719380 modbus: sc-crc: "CRC correct"
+4716046-4719380 modbus: cs-error: "Unknown function"
+4888129-4891463 modbus: sc-server-id: "Slave ID: 247"
+4888129-4891463 modbus: cs-server-id: "Slave ID: 247"
+4892799-4896133 modbus: sc-function: "Function 3: Read Holding Registers"
+4892799-4896133 modbus: cs-function: "Function 3: Read Holding Registers"
+4897449-4900783 modbus: sc-length: "Byte count: 16"
+4897449-4905455 modbus: cs-address: "Start at address 0x1004 / 34101"
+4902121-4910105 modbus: sc-data: "0x0400 / 1024"
+4906771-4914776 modbus: cs-length: "Read 4 units of data"
+4911442-4919426 modbus: sc-data: "0x0415 / 1045"
+4916092-4924098 modbus: cs-crc: "CRC correct"
+4919426-4925349 modbus: sc-error: "Message too short or not finished"
+4945113-4948447 modbus: sc-server-id: "Slave ID: 247"
+4945113-4948447 modbus: cs-server-id: "Slave ID: 247"
+4949689-4953023 modbus: sc-function: "Function 3: Read Holding Registers"
+4949689-4953023 modbus: cs-function: "Function 3: Read Holding Registers"
+4954264-4957598 modbus: sc-length: "Byte count: 8"
+4954264-4962174 modbus: cs-address: "Start at address 0x846 / 32119"
+4958840-4966749 modbus: sc-data: "0x4643 / 17987"
+4963415-4971325 modbus: cs-length: "Read 17201 units of data"
+4967991-4975901 modbus: sc-data: "0x3132 / 12594"
+4972567-4980476 modbus: cs-error: "CRC should be 66 13"
+4977142-4985052 modbus: sc-data: "0x0000 / 0"
+4981718-4985052 modbus: cs-error: "Unknown function"
+4986293-4989627 modbus: cs-error: "Unknown function"
+4986293-4994203 modbus: sc-data: "0x0000 / 0"
+4990869-4994203 modbus: cs-error: "Unknown function"
+4995445-4998779 modbus: cs-error: "Unknown function"
+4995445-5003354 modbus: sc-crc: "CRC correct"
+5000020-5003354 modbus: cs-error: "Unknown function"
+5139064-5142398 modbus: sc-server-id: "Slave ID: 247"
+5139064-5142398 modbus: cs-server-id: "Slave ID: 247"
+5143735-5147069 modbus: sc-function: "Function 3: Read Holding Registers"
+5143735-5147069 modbus: cs-function: "Function 3: Read Holding Registers"
+5148385-5151719 modbus: sc-length: "Byte count: 0"
+5148385-5156390 modbus: cs-address: "Start at address 0x23 / 30036"
+5153056-5161040 modbus: sc-error: "CRC should be 192 194"
+5157706-5165712 modbus: cs-length: "Read 4 units of data"
+5162378-5170362 modbus: sc-error: "Message too long"
+5167028-5175034 modbus: cs-crc: "CRC correct"
+5196018-5199352 modbus: sc-server-id: "Slave ID: 247"
+5196018-5199352 modbus: cs-server-id: "Slave ID: 247"
+5200593-5203927 modbus: sc-function: "Function 3: Read Holding Registers"
+5200593-5203927 modbus: cs-function: "Function 3: Read Holding Registers"
+5205169-5208503 modbus: sc-length: "Byte count: 8"
+5205169-5213079 modbus: cs-address: "Start at address 0x847 / 32120"
+5209745-5217654 modbus: sc-data: "0x4753 / 18259"
+5214320-5222230 modbus: cs-length: "Read 21315 units of data"
+5218896-5226805 modbus: sc-data: "0x4343 / 17219"
+5223471-5231381 modbus: cs-error: "CRC should be 158 40"
+5228047-5235957 modbus: sc-data: "0x3953 / 14675"
+5232623-5235957 modbus: cs-error: "Unknown function"
+5237198-5240532 modbus: cs-error: "Unknown function"
+5237198-5245108 modbus: sc-data: "0x4100 / 16640"
+5241774-5245108 modbus: cs-error: "Unknown function"
+5246349-5249683 modbus: cs-error: "Unknown function"
+5246349-5254259 modbus: sc-crc: "CRC correct"
+5250925-5254259 modbus: cs-error: "Unknown function"
+5389382-5392716 modbus: sc-server-id: "Slave ID: 247"
+5389382-5392716 modbus: cs-server-id: "Slave ID: 247"
+5394052-5397386 modbus: sc-function: "Function 3: Read Holding Registers"
+5394052-5397386 modbus: cs-function: "Function 3: Read Holding Registers"
+5398702-5402036 modbus: sc-length: "Byte count: 64"
+5398702-5406707 modbus: cs-address: "Start at address 0x4082 / 46515"
+5403373-5411357 modbus: sc-data: "0x8200 / 33280"
+5408023-5416029 modbus: cs-length: "Read 2 units of data"
+5412695-5420679 modbus: sc-data: "0x0265 / 613"
+5417345-5425351 modbus: cs-crc: "CRC correct"
+5420679-5426602 modbus: sc-error: "Message too short or not finished"
+5444297-5447631 modbus: sc-server-id: "Slave ID: 247"
+5444297-5447631 modbus: cs-server-id: "Slave ID: 247"
+5448872-5452206 modbus: sc-function: "Function 3: Read Holding Registers"
+5448872-5452206 modbus: cs-function: "Function 3: Read Holding Registers"
+5453448-5456782 modbus: sc-length: "Byte count: 4"
+5453448-5461357 modbus: cs-address: "Start at address 0x400 / 31025"
+5458023-5465933 modbus: sc-data: "0x0000 / 0"
+5462599-5470509 modbus: cs-length: "Read 0 units of data"
+5467175-5475084 modbus: sc-data: "0x0003 / 3"
+5471750-5479660 modbus: cs-error: "CRC should be 80 108"
+5476326-5484235 modbus: sc-crc: "CRC correct"
+5480901-5484235 modbus: cs-error: "Unknown function"
+5888288-5891622 modbus: sc-server-id: "Slave ID: 247"
+5888288-5891622 modbus: cs-server-id: "Slave ID: 247"
+5892958-5896292 modbus: sc-function: "Function 3: Read Holding Registers"
+5892958-5896292 modbus: cs-function: "Function 3: Read Holding Registers"
+5897608-5900942 modbus: sc-length: "Byte count: 0"
+5897608-5905614 modbus: cs-address: "Start at address 0x0 / 30001"
+5902280-5910264 modbus: sc-error: "CRC should be 192 194"
+5906930-5914935 modbus: cs-length: "Read 15 units of data"
+5911601-5919585 modbus: sc-error: "Message too long"
+5916251-5924257 modbus: cs-crc: "CRC correct"
+5941452-5944786 modbus: sc-server-id: "Slave ID: 247"
+5941452-5944786 modbus: cs-server-id: "Slave ID: 247"
+5946028-5949362 modbus: sc-function: "Function 3: Read Holding Registers"
+5946028-5949362 modbus: cs-function: "Function 3: Read Holding Registers"
+5950604-5953938 modbus: sc-length: "Byte count: 30"
+5950604-5958513 modbus: cs-address: "Start at address 0x1E00 / 37681"
+5955179-5963089 modbus: sc-data: "0x0000 / 0"
+5959755-5967664 modbus: cs-length: "Read 0 units of data"
+5964330-5972240 modbus: sc-data: "0x0000 / 0"
+5968906-5976816 modbus: cs-error: "CRC should be 87 116"
+5973482-5981391 modbus: sc-data: "0x41B7 / 16823"
+5978057-5981391 modbus: cs-error: "Unknown function"
+5982633-5985967 modbus: cs-error: "Unknown function"
+5982633-5990543 modbus: sc-data: "0xCBE0 / 52192"
+5987209-5990543 modbus: cs-error: "Unknown function"
+5991784-5995118 modbus: cs-error: "Unknown function"
+5991784-5999694 modbus: sc-data: "0x3E57 / 15959"
+5996360-5999694 modbus: cs-error: "Unknown function"
+6000935-6004269 modbus: cs-error: "Unknown function"
+6000935-6008845 modbus: sc-data: "0x9E9F / 40607"
+6005511-6008845 modbus: cs-error: "Unknown function"
+6010087-6013421 modbus: cs-error: "Unknown function"
+6010087-6017996 modbus: sc-data: "0x0000 / 0"
+6014662-6017996 modbus: cs-error: "Unknown function"
+6019238-6022572 modbus: cs-error: "Unknown function"
+6019238-6027147 modbus: sc-data: "0x0000 / 0"
+6023813-6027147 modbus: cs-error: "Unknown function"
+6028389-6031723 modbus: cs-error: "Unknown function"
+6028389-6036299 modbus: sc-data: "0x0000 / 0"
+6032965-6036299 modbus: cs-error: "Unknown function"
+6037540-6040874 modbus: cs-error: "Unknown function"
+6037540-6045450 modbus: sc-data: "0x0000 / 0"
+6042116-6045450 modbus: cs-error: "Unknown function"
+6046691-6050025 modbus: cs-error: "Unknown function"
+6046691-6054601 modbus: sc-data: "0x0000 / 0"
+6051267-6054601 modbus: cs-error: "Unknown function"
+6055843-6059177 modbus: cs-error: "Unknown function"
+6055843-6063752 modbus: sc-data: "0x0000 / 0"
+6060418-6063752 modbus: cs-error: "Unknown function"
+6064994-6068328 modbus: cs-error: "Unknown function"
+6064994-6072904 modbus: sc-data: "0x8000 / 32768"
+6069570-6072904 modbus: cs-error: "Unknown function"
+6074145-6077479 modbus: cs-error: "Unknown function"
+6074145-6082055 modbus: sc-data: "0x0008 / 8"
+6078721-6082055 modbus: cs-error: "Unknown function"
+6083296-6086630 modbus: cs-error: "Unknown function"
+6083296-6091206 modbus: sc-data: "0x0000 / 0"
+6087872-6091206 modbus: cs-error: "Unknown function"
+6092448-6095782 modbus: cs-error: "Unknown function"
+6092448-6100357 modbus: sc-crc: "CRC correct"
+6097023-6100357 modbus: cs-error: "Unknown function"
+6266760-6270094 modbus: sc-server-id: "Slave ID: 247"
+6266760-6270094 modbus: cs-server-id: "Slave ID: 247"
+6271430-6274764 modbus: sc-function: "Function 3: Read Holding Registers"
+6271430-6274764 modbus: cs-function: "Function 3: Read Holding Registers"
+6276080-6279414 modbus: sc-length: "Byte count: 0"
+6276080-6284086 modbus: cs-address: "Start at address 0xD / 30014"
+6280752-6288736 modbus: sc-error: "CRC should be 192 194"
+6285402-6293408 modbus: cs-length: "Read 1 units of data"
+6290074-6298058 modbus: sc-error: "Message too long"
+6294724-6302729 modbus: cs-crc: "CRC correct"
+6319590-6322924 modbus: sc-server-id: "Slave ID: 247"
+6319590-6322924 modbus: cs-server-id: "Slave ID: 247"
+6324166-6327500 modbus: sc-function: "Function 3: Read Holding Registers"
+6324166-6327500 modbus: cs-function: "Function 3: Read Holding Registers"
+6328741-6332075 modbus: sc-length: "Byte count: 2"
+6328741-6336651 modbus: cs-address: "Start at address 0x200 / 30513"
+6333317-6341227 modbus: sc-data: "0x0008 / 8"
+6337893-6345802 modbus: cs-length: "Read 2161 units of data"
+6342468-6350378 modbus: sc-crc: "CRC correct"
+6345802-6351629 modbus: cs-error: "Message too short or not finished"
+6513600-6516934 modbus: sc-server-id: "Slave ID: 247"
+6513600-6516934 modbus: cs-server-id: "Slave ID: 247"
+6518270-6521604 modbus: sc-function: "Function 3: Read Holding Registers"
+6518270-6521604 modbus: cs-function: "Function 3: Read Holding Registers"
+6522921-6526255 modbus: sc-length: "Byte count: 64"
+6522921-6530926 modbus: cs-address: "Start at address 0x4082 / 46515"
+6527592-6535576 modbus: sc-data: "0x8200 / 33280"
+6532242-6540248 modbus: cs-length: "Read 2 units of data"
+6536914-6544898 modbus: sc-data: "0x0265 / 613"
+6541564-6549569 modbus: cs-crc: "CRC correct"
+6544898-6550820 modbus: sc-error: "Message too short or not finished"
+6572393-6575727 modbus: sc-server-id: "Slave ID: 247"
+6572393-6575727 modbus: cs-server-id: "Slave ID: 247"
+6576968-6580302 modbus: sc-function: "Function 3: Read Holding Registers"
+6576968-6580302 modbus: cs-function: "Function 3: Read Holding Registers"
+6581544-6584878 modbus: sc-length: "Byte count: 4"
+6581544-6589454 modbus: cs-address: "Start at address 0x400 / 31025"
+6586120-6594029 modbus: sc-data: "0x0000 / 0"
+6590695-6598605 modbus: cs-length: "Read 0 units of data"
+6595271-6603180 modbus: sc-data: "0x0003 / 3"
+6599846-6607756 modbus: cs-error: "CRC should be 80 108"
+6604422-6612332 modbus: sc-crc: "CRC correct"
+6608998-6612332 modbus: cs-error: "Unknown function"
+6776545-6779879 modbus: sc-server-id: "Slave ID: 247"
+6776545-6779879 modbus: cs-server-id: "Slave ID: 247"
+6781215-6784549 modbus: sc-function: "Function 3: Read Holding Registers"
+6781215-6784549 modbus: cs-function: "Function 3: Read Holding Registers"
+6785865-6789199 modbus: sc-length: "Byte count: 0"
+6785865-6793871 modbus: cs-address: "Start at address 0x0 / 30001"
+6790537-6798521 modbus: sc-error: "CRC should be 192 194"
+6795187-6803192 modbus: cs-length: "Read 15 units of data"
+6799858-6807843 modbus: sc-error: "Message too long"
+6804509-6812514 modbus: cs-crc: "CRC correct"
+6829719-6833053 modbus: sc-server-id: "Slave ID: 247"
+6829719-6833053 modbus: cs-server-id: "Slave ID: 247"
+6834295-6837629 modbus: sc-function: "Function 3: Read Holding Registers"
+6834295-6837629 modbus: cs-function: "Function 3: Read Holding Registers"
+6838870-6842204 modbus: sc-length: "Byte count: 30"
+6838870-6846780 modbus: cs-address: "Start at address 0x1E00 / 37681"
+6843446-6851355 modbus: sc-data: "0x0000 / 0"
+6848021-6855931 modbus: cs-length: "Read 0 units of data"
+6852597-6860507 modbus: sc-data: "0x0000 / 0"
+6857173-6865082 modbus: cs-error: "CRC should be 87 116"
+6861748-6869658 modbus: sc-data: "0x41B7 / 16823"
+6866324-6869658 modbus: cs-error: "Unknown function"
+6870899-6874233 modbus: cs-error: "Unknown function"
+6870899-6878809 modbus: sc-data: "0xCBE0 / 52192"
+6875475-6878809 modbus: cs-error: "Unknown function"
+6880051-6883385 modbus: cs-error: "Unknown function"
+6880051-6887960 modbus: sc-data: "0x3E57 / 15959"
+6884626-6887960 modbus: cs-error: "Unknown function"
+6889202-6892536 modbus: cs-error: "Unknown function"
+6889202-6897112 modbus: sc-data: "0x9E9F / 40607"
+6893778-6897112 modbus: cs-error: "Unknown function"
+6898353-6901687 modbus: cs-error: "Unknown function"
+6898353-6906263 modbus: sc-data: "0x0000 / 0"
+6902929-6906263 modbus: cs-error: "Unknown function"
+6907504-6910838 modbus: cs-error: "Unknown function"
+6907504-6915414 modbus: sc-data: "0x0000 / 0"
+6912080-6915414 modbus: cs-error: "Unknown function"
+6916656-6919990 modbus: cs-error: "Unknown function"
+6916656-6924565 modbus: sc-data: "0x0000 / 0"
+6921231-6924565 modbus: cs-error: "Unknown function"
+6925807-6929141 modbus: cs-error: "Unknown function"
+6925807-6933716 modbus: sc-data: "0x0000 / 0"
+6930382-6933716 modbus: cs-error: "Unknown function"
+6934958-6938292 modbus: cs-error: "Unknown function"
+6934958-6942868 modbus: sc-data: "0x0000 / 0"
+6939534-6942868 modbus: cs-error: "Unknown function"
+6944109-6947443 modbus: cs-error: "Unknown function"
+6944109-6952019 modbus: sc-data: "0x0000 / 0"
+6948685-6952019 modbus: cs-error: "Unknown function"
+6953260-6956594 modbus: cs-error: "Unknown function"
+6953260-6961170 modbus: sc-data: "0x8000 / 32768"
+6957836-6961170 modbus: cs-error: "Unknown function"
+6962412-6965746 modbus: cs-error: "Unknown function"
+6962412-6970321 modbus: sc-data: "0x0008 / 8"
+6966987-6970321 modbus: cs-error: "Unknown function"
+6971563-6974897 modbus: cs-error: "Unknown function"
+6971563-6979472 modbus: sc-data: "0x0000 / 0"
+6976138-6979472 modbus: cs-error: "Unknown function"
+6980714-6984048 modbus: cs-error: "Unknown function"
+6980714-6988624 modbus: sc-crc: "CRC correct"
+6985290-6988624 modbus: cs-error: "Unknown function"
+7140171-7143505 modbus: sc-server-id: "Slave ID: 247"
+7140171-7143505 modbus: cs-server-id: "Slave ID: 247"
+7144842-7148176 modbus: sc-function: "Function 3: Read Holding Registers"
+7144842-7148176 modbus: cs-function: "Function 3: Read Holding Registers"
+7149492-7152826 modbus: sc-length: "Byte count: 0"
+7149492-7157497 modbus: cs-address: "Start at address 0xD / 30014"
+7154163-7162147 modbus: sc-error: "CRC should be 192 194"
+7158813-7166819 modbus: cs-length: "Read 1 units of data"
+7163485-7171469 modbus: sc-error: "Message too long"
+7168135-7176140 modbus: cs-crc: "CRC correct"
+7193038-7196372 modbus: sc-server-id: "Slave ID: 247"
+7193038-7196372 modbus: cs-server-id: "Slave ID: 247"
+7197614-7200948 modbus: sc-function: "Function 3: Read Holding Registers"
+7197614-7200948 modbus: cs-function: "Function 3: Read Holding Registers"
+7202189-7205523 modbus: sc-length: "Byte count: 2"
+7202189-7210099 modbus: cs-address: "Start at address 0x200 / 30513"
+7206765-7214674 modbus: sc-data: "0x0008 / 8"
+7211340-7219250 modbus: cs-length: "Read 2161 units of data"
+7215916-7223826 modbus: sc-crc: "CRC correct"
+7219250-7225077 modbus: cs-error: "Message too short or not finished"
+7388526-7391860 modbus: sc-server-id: "Slave ID: 247"
+7388526-7391860 modbus: cs-server-id: "Slave ID: 247"
+7393196-7396530 modbus: sc-function: "Function 3: Read Holding Registers"
+7393196-7396530 modbus: cs-function: "Function 3: Read Holding Registers"
+7397846-7401180 modbus: sc-length: "Byte count: 64"
+7397846-7405852 modbus: cs-address: "Start at address 0x4082 / 46515"
+7402518-7410502 modbus: sc-data: "0x8200 / 33280"
+7407168-7415173 modbus: cs-length: "Read 2 units of data"
+7411839-7419823 modbus: sc-data: "0x0265 / 613"
+7416489-7424495 modbus: cs-crc: "CRC correct"
+7419823-7425746 modbus: sc-error: "Message too short or not finished"
+7443423-7446757 modbus: sc-server-id: "Slave ID: 247"
+7443423-7446757 modbus: cs-server-id: "Slave ID: 247"
+7447998-7451332 modbus: sc-function: "Function 3: Read Holding Registers"
+7447998-7451332 modbus: cs-function: "Function 3: Read Holding Registers"
+7452574-7455908 modbus: sc-length: "Byte count: 4"
+7452574-7460484 modbus: cs-address: "Start at address 0x400 / 31025"
+7457150-7465059 modbus: sc-data: "0x0000 / 0"
+7461725-7469635 modbus: cs-length: "Read 0 units of data"
+7466301-7474210 modbus: sc-data: "0x0003 / 3"
+7470876-7478786 modbus: cs-error: "CRC should be 80 108"
+7475452-7483362 modbus: sc-crc: "CRC correct"
+7480028-7483362 modbus: cs-error: "Unknown function"
+7651471-7654805 modbus: sc-server-id: "Slave ID: 247"
+7651471-7654805 modbus: cs-server-id: "Slave ID: 247"
+7656141-7659475 modbus: sc-function: "Function 3: Read Holding Registers"
+7656141-7659475 modbus: cs-function: "Function 3: Read Holding Registers"
+7660791-7664125 modbus: sc-length: "Byte count: 0"
+7660791-7668797 modbus: cs-address: "Start at address 0x0 / 30001"
+7665463-7673447 modbus: sc-error: "CRC should be 192 194"
+7670113-7678118 modbus: cs-length: "Read 15 units of data"
+7674784-7682768 modbus: sc-error: "Message too long"
+7679434-7687440 modbus: cs-crc: "CRC correct"
+7704648-7707982 modbus: sc-server-id: "Slave ID: 247"
+7704648-7707982 modbus: cs-server-id: "Slave ID: 247"
+7709224-7712558 modbus: sc-function: "Function 3: Read Holding Registers"
+7709224-7712558 modbus: cs-function: "Function 3: Read Holding Registers"
+7713800-7717134 modbus: sc-length: "Byte count: 30"
+7713800-7721709 modbus: cs-address: "Start at address 0x1E00 / 37681"
+7718375-7726285 modbus: sc-data: "0x0000 / 0"
+7722951-7730861 modbus: cs-length: "Read 0 units of data"
+7727527-7735436 modbus: sc-data: "0x0000 / 0"
+7732102-7740012 modbus: cs-error: "CRC should be 87 116"
+7736678-7744587 modbus: sc-data: "0x41B7 / 16823"
+7741253-7744587 modbus: cs-error: "Unknown function"
+7745829-7749163 modbus: cs-error: "Unknown function"
+7745829-7753739 modbus: sc-data: "0xCBE0 / 52192"
+7750405-7753739 modbus: cs-error: "Unknown function"
+7754980-7758314 modbus: cs-error: "Unknown function"
+7754980-7762890 modbus: sc-data: "0x3E57 / 15959"
+7759556-7762890 modbus: cs-error: "Unknown function"
+7764132-7767466 modbus: cs-error: "Unknown function"
+7764132-7772041 modbus: sc-data: "0x9E9F / 40607"
+7768707-7772041 modbus: cs-error: "Unknown function"
+7773283-7776617 modbus: cs-error: "Unknown function"
+7773283-7781192 modbus: sc-data: "0x0000 / 0"
+7777858-7781192 modbus: cs-error: "Unknown function"
+7782434-7785768 modbus: cs-error: "Unknown function"
+7782434-7790344 modbus: sc-data: "0x0000 / 0"
+7787010-7790344 modbus: cs-error: "Unknown function"
+7791585-7794919 modbus: cs-error: "Unknown function"
+7791585-7799495 modbus: sc-data: "0x3AC3 / 15043"
+7796161-7799495 modbus: cs-error: "Unknown function"
+7800736-7804070 modbus: cs-error: "Unknown function"
+7800736-7808646 modbus: sc-data: "0x0FB5 / 4021"
+7805312-7808646 modbus: cs-error: "Unknown function"
+7809888-7813222 modbus: cs-error: "Unknown function"
+7809888-7817797 modbus: sc-data: "0x0000 / 0"
+7814463-7817797 modbus: cs-error: "Unknown function"
+7819039-7822373 modbus: cs-error: "Unknown function"
+7819039-7826948 modbus: sc-data: "0x0000 / 0"
+7823614-7826948 modbus: cs-error: "Unknown function"
+7828190-7831524 modbus: cs-error: "Unknown function"
+7828190-7836100 modbus: sc-data: "0x8000 / 32768"
+7832766-7836100 modbus: cs-error: "Unknown function"
+7837341-7840675 modbus: cs-error: "Unknown function"
+7837341-7845251 modbus: sc-data: "0x0008 / 8"
+7841917-7845251 modbus: cs-error: "Unknown function"
+7846493-7849827 modbus: cs-error: "Unknown function"
+7846493-7854402 modbus: sc-data: "0x0000 / 0"
+7851068-7854402 modbus: cs-error: "Unknown function"
+7855644-7858978 modbus: cs-error: "Unknown function"
+7855644-7863553 modbus: sc-crc: "CRC correct"
+7860219-7863553 modbus: cs-error: "Unknown function"
+8015204-8018538 modbus: sc-server-id: "Slave ID: 247"
+8015204-8018538 modbus: cs-server-id: "Slave ID: 247"
+8019874-8023208 modbus: sc-function: "Function 3: Read Holding Registers"
+8019874-8023208 modbus: cs-function: "Function 3: Read Holding Registers"
+8024524-8027858 modbus: sc-length: "Byte count: 0"
+8024524-8032530 modbus: cs-address: "Start at address 0xD / 30014"
+8029196-8037180 modbus: sc-error: "CRC should be 192 194"
+8033846-8041851 modbus: cs-length: "Read 1 units of data"
+8038517-8046501 modbus: sc-error: "Message too long"
+8043167-8051173 modbus: cs-crc: "CRC correct"
+8068046-8071380 modbus: sc-server-id: "Slave ID: 247"
+8068046-8071380 modbus: cs-server-id: "Slave ID: 247"
+8072621-8075955 modbus: sc-function: "Function 3: Read Holding Registers"
+8072621-8075955 modbus: cs-function: "Function 3: Read Holding Registers"
+8077197-8080531 modbus: sc-length: "Byte count: 2"
+8077197-8085107 modbus: cs-address: "Start at address 0x200 / 30513"
+8081773-8089682 modbus: sc-data: "0x0008 / 8"
+8086348-8094258 modbus: cs-length: "Read 2161 units of data"
+8090924-8098833 modbus: sc-crc: "CRC correct"
+8094258-8100084 modbus: cs-error: "Message too short or not finished"
+8263516-8266850 modbus: sc-server-id: "Slave ID: 247"
+8263516-8266850 modbus: cs-server-id: "Slave ID: 247"
+8268186-8271520 modbus: sc-function: "Function 3: Read Holding Registers"
+8268186-8271520 modbus: cs-function: "Function 3: Read Holding Registers"
+8272836-8276170 modbus: sc-length: "Byte count: 64"
+8272836-8280841 modbus: cs-address: "Start at address 0x4082 / 46515"
+8277507-8285491 modbus: sc-data: "0x8200 / 33280"
+8282157-8290163 modbus: cs-length: "Read 2 units of data"
+8286829-8294813 modbus: sc-data: "0x0265 / 613"
+8291479-8299484 modbus: cs-crc: "CRC correct"
+8294813-8300735 modbus: sc-error: "Message too short or not finished"
+8318431-8321765 modbus: sc-server-id: "Slave ID: 247"
+8318431-8321765 modbus: cs-server-id: "Slave ID: 247"
+8323006-8326340 modbus: sc-function: "Function 3: Read Holding Registers"
+8323006-8326340 modbus: cs-function: "Function 3: Read Holding Registers"
+8327582-8330916 modbus: sc-length: "Byte count: 4"
+8327582-8335491 modbus: cs-address: "Start at address 0x400 / 31025"
+8332157-8340067 modbus: sc-data: "0x0000 / 0"
+8336733-8344642 modbus: cs-length: "Read 0 units of data"
+8341308-8349218 modbus: sc-data: "0x0003 / 3"
+8345884-8353794 modbus: cs-error: "CRC should be 80 108"
+8350460-8358369 modbus: sc-crc: "CRC correct"
+8355035-8358369 modbus: cs-error: "Unknown function"
+8521853-8525187 modbus: sc-server-id: "Slave ID: 247"
+8521853-8525187 modbus: cs-server-id: "Slave ID: 247"
+8526523-8529857 modbus: sc-function: "Function 3: Read Holding Registers"
+8526523-8529857 modbus: cs-function: "Function 3: Read Holding Registers"
+8531173-8534507 modbus: sc-length: "Byte count: 0"
+8531173-8539179 modbus: cs-address: "Start at address 0x0 / 30001"
+8535845-8543829 modbus: sc-error: "CRC should be 192 194"
+8540495-8548500 modbus: cs-length: "Read 15 units of data"
+8545166-8553150 modbus: sc-error: "Message too long"
+8549816-8557822 modbus: cs-crc: "CRC correct"
+8575029-8578363 modbus: sc-server-id: "Slave ID: 247"
+8575029-8578363 modbus: cs-server-id: "Slave ID: 247"
+8579604-8582938 modbus: sc-function: "Function 3: Read Holding Registers"
+8579604-8582938 modbus: cs-function: "Function 3: Read Holding Registers"
+8584180-8587514 modbus: sc-length: "Byte count: 30"
+8584180-8592089 modbus: cs-address: "Start at address 0x1E00 / 37681"
+8588755-8596665 modbus: sc-data: "0x0000 / 0"
+8593331-8601241 modbus: cs-length: "Read 0 units of data"
+8597907-8605816 modbus: sc-data: "0x0000 / 0"
+8602482-8610392 modbus: cs-error: "CRC should be 87 116"
+8607058-8614968 modbus: sc-data: "0x41B7 / 16823"
+8611634-8614968 modbus: cs-error: "Unknown function"
+8616209-8619543 modbus: cs-error: "Unknown function"
+8616209-8624119 modbus: sc-data: "0xCBE0 / 52192"
+8620785-8624119 modbus: cs-error: "Unknown function"
+8625360-8628694 modbus: cs-error: "Unknown function"
+8625360-8633270 modbus: sc-data: "0x3E57 / 15959"
+8629936-8633270 modbus: cs-error: "Unknown function"
+8634512-8637846 modbus: cs-error: "Unknown function"
+8634512-8642421 modbus: sc-data: "0x9E9F / 40607"
+8639087-8642421 modbus: cs-error: "Unknown function"
+8643663-8646997 modbus: cs-error: "Unknown function"
+8643663-8651572 modbus: sc-data: "0x0000 / 0"
+8648238-8651572 modbus: cs-error: "Unknown function"
+8652814-8656148 modbus: cs-error: "Unknown function"
+8652814-8660724 modbus: sc-data: "0x0000 / 0"
+8657390-8660724 modbus: cs-error: "Unknown function"
+8661965-8665299 modbus: cs-error: "Unknown function"
+8661965-8669875 modbus: sc-data: "0x3AC3 / 15043"
+8666541-8669875 modbus: cs-error: "Unknown function"
+8671117-8674451 modbus: cs-error: "Unknown function"
+8671117-8679026 modbus: sc-data: "0x0FB5 / 4021"
+8675692-8679026 modbus: cs-error: "Unknown function"
+8680268-8683602 modbus: cs-error: "Unknown function"
+8680268-8688177 modbus: sc-data: "0x0000 / 0"
+8684843-8688177 modbus: cs-error: "Unknown function"
+8689419-8692753 modbus: cs-error: "Unknown function"
+8689419-8697329 modbus: sc-data: "0x0000 / 0"
+8693995-8697329 modbus: cs-error: "Unknown function"
+8698570-8701904 modbus: cs-error: "Unknown function"
+8698570-8706480 modbus: sc-data: "0x8000 / 32768"
+8703146-8706480 modbus: cs-error: "Unknown function"
+8707721-8711055 modbus: cs-error: "Unknown function"
+8707721-8715631 modbus: sc-data: "0x0008 / 8"
+8712297-8715631 modbus: cs-error: "Unknown function"
+8716873-8720207 modbus: cs-error: "Unknown function"
+8716873-8724782 modbus: sc-data: "0x0000 / 0"
+8721448-8724782 modbus: cs-error: "Unknown function"
+8726024-8729358 modbus: cs-error: "Unknown function"
+8726024-8733933 modbus: sc-crc: "CRC correct"
+8730599-8733933 modbus: cs-error: "Unknown function"
+8889937-8893271 modbus: sc-server-id: "Slave ID: 247"
+8889937-8893271 modbus: cs-server-id: "Slave ID: 247"
+8894608-8897942 modbus: sc-function: "Function 3: Read Holding Registers"
+8894608-8897942 modbus: cs-function: "Function 3: Read Holding Registers"
+8899257-8902591 modbus: sc-length: "Byte count: 0"
+8899257-8907263 modbus: cs-address: "Start at address 0xD / 30014"
+8903929-8911913 modbus: sc-error: "CRC should be 192 194"
+8908579-8916585 modbus: cs-length: "Read 1 units of data"
+8913251-8921235 modbus: sc-error: "Message too long"
+8917901-8925906 modbus: cs-crc: "CRC correct"
+8942767-8946101 modbus: sc-server-id: "Slave ID: 247"
+8942767-8946101 modbus: cs-server-id: "Slave ID: 247"
+8947343-8950677 modbus: sc-function: "Function 3: Read Holding Registers"
+8947343-8950677 modbus: cs-function: "Function 3: Read Holding Registers"
+8951919-8955253 modbus: sc-length: "Byte count: 2"
+8951919-8959828 modbus: cs-address: "Start at address 0x200 / 30513"
+8956494-8964404 modbus: sc-data: "0x0008 / 8"
+8961070-8968979 modbus: cs-length: "Read 2161 units of data"
+8965645-8973555 modbus: sc-crc: "CRC correct"
+8968979-8974806 modbus: cs-error: "Message too short or not finished"
+9138505-9141839 modbus: sc-server-id: "Slave ID: 247"
+9138505-9141839 modbus: cs-server-id: "Slave ID: 247"
+9143175-9146509 modbus: sc-function: "Function 3: Read Holding Registers"
+9143175-9146509 modbus: cs-function: "Function 3: Read Holding Registers"
+9147825-9151159 modbus: sc-length: "Byte count: 64"
+9147825-9155831 modbus: cs-address: "Start at address 0x4082 / 46515"
+9152497-9160481 modbus: sc-data: "0x8200 / 33280"
+9157147-9165153 modbus: cs-length: "Read 2 units of data"
+9161819-9169803 modbus: sc-data: "0x0265 / 613"
+9166469-9174474 modbus: cs-crc: "CRC correct"
+9169803-9175725 modbus: sc-error: "Message too short or not finished"
+9193412-9196746 modbus: sc-server-id: "Slave ID: 247"
+9193412-9196746 modbus: cs-server-id: "Slave ID: 247"
+9197988-9201322 modbus: sc-function: "Function 3: Read Holding Registers"
+9197988-9201322 modbus: cs-function: "Function 3: Read Holding Registers"
+9202563-9205897 modbus: sc-length: "Byte count: 4"
+9202563-9210473 modbus: cs-address: "Start at address 0x400 / 31025"
+9207139-9215049 modbus: sc-data: "0x0000 / 0"
+9211715-9219624 modbus: cs-length: "Read 0 units of data"
+9216290-9224200 modbus: sc-data: "0x0003 / 3"
+9220866-9228775 modbus: cs-error: "CRC should be 80 108"
+9225441-9233351 modbus: sc-crc: "CRC correct"
+9230017-9233351 modbus: cs-error: "Unknown function"
+9397952-9401286 modbus: sc-server-id: "Slave ID: 247"
+9397952-9401286 modbus: cs-server-id: "Slave ID: 247"
+9402622-9405956 modbus: sc-function: "Function 3: Read Holding Registers"
+9402622-9405956 modbus: cs-function: "Function 3: Read Holding Registers"
+9407272-9410606 modbus: sc-length: "Byte count: 0"
+9407272-9415278 modbus: cs-address: "Start at address 0x0 / 30001"
+9411944-9419928 modbus: sc-error: "CRC should be 192 194"
+9416594-9424599 modbus: cs-length: "Read 15 units of data"
+9421265-9429249 modbus: sc-error: "Message too long"
+9425915-9433921 modbus: cs-crc: "CRC correct"
+9452662-9455996 modbus: sc-server-id: "Slave ID: 247"
+9452662-9455996 modbus: cs-server-id: "Slave ID: 247"
+9457238-9460572 modbus: sc-function: "Function 3: Read Holding Registers"
+9457238-9460572 modbus: cs-function: "Function 3: Read Holding Registers"
+9461813-9465147 modbus: sc-length: "Byte count: 30"
+9461813-9469723 modbus: cs-address: "Start at address 0x1E00 / 37681"
+9466389-9474299 modbus: sc-data: "0x0000 / 0"
+9470965-9478874 modbus: cs-length: "Read 0 units of data"
+9475540-9483450 modbus: sc-data: "0x0000 / 0"
+9480116-9488025 modbus: cs-error: "CRC should be 87 116"
+9484691-9492601 modbus: sc-data: "0x41B7 / 16823"
+9489267-9492601 modbus: cs-error: "Unknown function"
+9493843-9497177 modbus: cs-error: "Unknown function"
+9493843-9501752 modbus: sc-data: "0xCBE0 / 52192"
+9498418-9501752 modbus: cs-error: "Unknown function"
+9502994-9506328 modbus: cs-error: "Unknown function"
+9502994-9510903 modbus: sc-data: "0x3E57 / 15959"
+9507569-9510903 modbus: cs-error: "Unknown function"
+9512145-9515479 modbus: cs-error: "Unknown function"
+9512145-9520055 modbus: sc-data: "0x9E9F / 40607"
+9516721-9520055 modbus: cs-error: "Unknown function"
+9521296-9524630 modbus: cs-error: "Unknown function"
+9521296-9529206 modbus: sc-data: "0x0000 / 0"
+9525872-9529206 modbus: cs-error: "Unknown function"
+9530447-9533781 modbus: cs-error: "Unknown function"
+9530447-9538357 modbus: sc-data: "0x0000 / 0"
+9535023-9538357 modbus: cs-error: "Unknown function"
+9539599-9542933 modbus: cs-error: "Unknown function"
+9539599-9547508 modbus: sc-data: "0x0000 / 0"
+9544174-9547508 modbus: cs-error: "Unknown function"
+9548750-9552084 modbus: cs-error: "Unknown function"
+9548750-9556660 modbus: sc-data: "0x0000 / 0"
+9553326-9556660 modbus: cs-error: "Unknown function"
+9557901-9561235 modbus: cs-error: "Unknown function"
+9557901-9565811 modbus: sc-data: "0x0000 / 0"
+9562477-9565811 modbus: cs-error: "Unknown function"
+9567052-9570386 modbus: cs-error: "Unknown function"
+9567052-9574962 modbus: sc-data: "0x0000 / 0"
+9571628-9574962 modbus: cs-error: "Unknown function"
+9576204-9579538 modbus: cs-error: "Unknown function"
+9576204-9584113 modbus: sc-data: "0x8000 / 32768"
+9580779-9584113 modbus: cs-error: "Unknown function"
+9585355-9588689 modbus: cs-error: "Unknown function"
+9585355-9593264 modbus: sc-data: "0x0008 / 8"
+9589930-9593264 modbus: cs-error: "Unknown function"
+9594506-9597840 modbus: cs-error: "Unknown function"
+9594506-9602416 modbus: sc-data: "0x0000 / 0"
+9599082-9602416 modbus: cs-error: "Unknown function"
+9603657-9606991 modbus: cs-error: "Unknown function"
+9603657-9611567 modbus: sc-crc: "CRC correct"
+9608233-9611567 modbus: cs-error: "Unknown function"
+9765503-9768837 modbus: sc-server-id: "Slave ID: 247"
+9765503-9768837 modbus: cs-server-id: "Slave ID: 247"
+9770173-9773507 modbus: sc-function: "Function 3: Read Holding Registers"
+9770173-9773507 modbus: cs-function: "Function 3: Read Holding Registers"
+9774823-9778157 modbus: sc-length: "Byte count: 0"
+9774823-9782829 modbus: cs-address: "Start at address 0xD / 30014"
+9779495-9787479 modbus: sc-error: "CRC should be 192 194"
+9784145-9792150 modbus: cs-length: "Read 1 units of data"
+9788816-9796800 modbus: sc-error: "Message too long"
+9793466-9801472 modbus: cs-crc: "CRC correct"
+9818321-9821655 modbus: sc-server-id: "Slave ID: 247"
+9818321-9821655 modbus: cs-server-id: "Slave ID: 247"
+9822897-9826231 modbus: sc-function: "Function 3: Read Holding Registers"
+9822897-9826231 modbus: cs-function: "Function 3: Read Holding Registers"
+9827472-9830806 modbus: sc-length: "Byte count: 2"
+9827472-9835382 modbus: cs-address: "Start at address 0x200 / 30513"
+9832048-9839957 modbus: sc-data: "0x0008 / 8"
+9836623-9844533 modbus: cs-length: "Read 2161 units of data"
+9841199-9849109 modbus: sc-crc: "CRC correct"
+9844533-9850360 modbus: cs-error: "Message too short or not finished"
+10013473-10016807 modbus: sc-server-id: "Slave ID: 247"
+10013473-10016807 modbus: cs-server-id: "Slave ID: 247"
+10018144-10021478 modbus: sc-function: "Function 3: Read Holding Registers"
+10018144-10021478 modbus: cs-function: "Function 3: Read Holding Registers"
+10022794-10026128 modbus: sc-length: "Byte count: 64"
+10022794-10030799 modbus: cs-address: "Start at address 0x4082 / 46515"
+10027465-10035449 modbus: sc-data: "0x8200 / 33280"
+10032115-10040121 modbus: cs-length: "Read 2 units of data"
+10036787-10044771 modbus: sc-data: "0x0265 / 613"
+10041437-10049442 modbus: cs-crc: "CRC correct"
+10044771-10050693 modbus: sc-error: "Message too short or not finished"
+10068394-10071728 modbus: sc-server-id: "Slave ID: 247"
+10068394-10071728 modbus: cs-server-id: "Slave ID: 247"
+10072969-10076303 modbus: sc-function: "Function 3: Read Holding Registers"
+10072969-10076303 modbus: cs-function: "Function 3: Read Holding Registers"
+10077545-10080879 modbus: sc-length: "Byte count: 4"
+10077545-10085455 modbus: cs-address: "Start at address 0x400 / 31025"
+10082121-10090030 modbus: sc-data: "0x0000 / 0"
+10086696-10094606 modbus: cs-length: "Read 0 units of data"
+10091272-10099181 modbus: sc-data: "0x0003 / 3"
+10095847-10103757 modbus: cs-error: "CRC should be 80 108"
+10100423-10108333 modbus: sc-crc: "CRC correct"
+10104999-10108333 modbus: cs-error: "Unknown function"
+10272621-10275955 modbus: sc-server-id: "Slave ID: 247"
+10272621-10275955 modbus: cs-server-id: "Slave ID: 247"
+10277292-10280626 modbus: sc-function: "Function 3: Read Holding Registers"
+10277292-10280626 modbus: cs-function: "Function 3: Read Holding Registers"
+10281942-10285276 modbus: sc-length: "Byte count: 0"
+10281942-10289947 modbus: cs-address: "Start at address 0x0 / 30001"
+10286613-10294597 modbus: sc-error: "CRC should be 192 194"
+10291263-10299269 modbus: cs-length: "Read 15 units of data"
+10295935-10303919 modbus: sc-error: "Message too long"
+10300585-10308590 modbus: cs-crc: "CRC correct"
+10325798-10329132 modbus: sc-server-id: "Slave ID: 247"
+10325798-10329132 modbus: cs-server-id: "Slave ID: 247"
+10330374-10333708 modbus: sc-function: "Function 3: Read Holding Registers"
+10330374-10333708 modbus: cs-function: "Function 3: Read Holding Registers"
+10334949-10338283 modbus: sc-length: "Byte count: 30"
+10334949-10342859 modbus: cs-address: "Start at address 0x1E00 / 37681"
+10339525-10347434 modbus: sc-data: "0x0000 / 0"
+10344100-10352010 modbus: cs-length: "Read 0 units of data"
+10348676-10356586 modbus: sc-data: "0x0000 / 0"
+10353252-10361161 modbus: cs-error: "CRC should be 87 116"
+10357827-10365737 modbus: sc-data: "0x41B7 / 16823"
+10362403-10365737 modbus: cs-error: "Unknown function"
+10366978-10370312 modbus: cs-error: "Unknown function"
+10366978-10374888 modbus: sc-data: "0xCBE0 / 52192"
+10371554-10374888 modbus: cs-error: "Unknown function"
+10376130-10379464 modbus: cs-error: "Unknown function"
+10376130-10384039 modbus: sc-data: "0x3E57 / 15959"
+10380705-10384039 modbus: cs-error: "Unknown function"
+10385281-10388615 modbus: cs-error: "Unknown function"
+10385281-10393190 modbus: sc-data: "0x9E9F / 40607"
+10389856-10393190 modbus: cs-error: "Unknown function"
+10394432-10397766 modbus: cs-error: "Unknown function"
+10394432-10402342 modbus: sc-data: "0x0000 / 0"
+10399008-10402342 modbus: cs-error: "Unknown function"
+10403583-10406917 modbus: cs-error: "Unknown function"
+10403583-10411493 modbus: sc-data: "0x0000 / 0"
+10408159-10411493 modbus: cs-error: "Unknown function"
+10412735-10416069 modbus: cs-error: "Unknown function"
+10412735-10420644 modbus: sc-data: "0x3AC3 / 15043"
+10417310-10420644 modbus: cs-error: "Unknown function"
+10421886-10425220 modbus: cs-error: "Unknown function"
+10421886-10429795 modbus: sc-data: "0x0FB5 / 4021"
+10426461-10429795 modbus: cs-error: "Unknown function"
+10431037-10434371 modbus: cs-error: "Unknown function"
+10431037-10438947 modbus: sc-data: "0x0000 / 0"
+10435613-10438947 modbus: cs-error: "Unknown function"
+10440188-10443522 modbus: cs-error: "Unknown function"
+10440188-10448098 modbus: sc-data: "0x0000 / 0"
+10444764-10448098 modbus: cs-error: "Unknown function"
+10449339-10452673 modbus: cs-error: "Unknown function"
+10449339-10457249 modbus: sc-data: "0x8000 / 32768"
+10453915-10457249 modbus: cs-error: "Unknown function"
+10458491-10461825 modbus: cs-error: "Unknown function"
+10458491-10466400 modbus: sc-data: "0x0008 / 8"
+10463066-10466400 modbus: cs-error: "Unknown function"
+10467642-10470976 modbus: cs-error: "Unknown function"
+10467642-10475551 modbus: sc-data: "0x0000 / 0"
+10472217-10475551 modbus: cs-error: "Unknown function"
+10476793-10480127 modbus: cs-error: "Unknown function"
+10476793-10484703 modbus: sc-crc: "CRC correct"
+10481369-10484703 modbus: cs-error: "Unknown function"
+10640258-10643592 modbus: sc-server-id: "Slave ID: 247"
+10640258-10643592 modbus: cs-server-id: "Slave ID: 247"
+10644928-10648262 modbus: sc-function: "Function 3: Read Holding Registers"
+10644928-10648262 modbus: cs-function: "Function 3: Read Holding Registers"
+10649578-10652912 modbus: sc-length: "Byte count: 0"
+10649578-10657584 modbus: cs-address: "Start at address 0xD / 30014"
+10654250-10662234 modbus: sc-error: "CRC should be 192 194"
+10658900-10666905 modbus: cs-length: "Read 1 units of data"
+10663571-10671555 modbus: sc-error: "Message too long"
+10668221-10676227 modbus: cs-crc: "CRC correct"
+10693095-10696429 modbus: sc-server-id: "Slave ID: 247"
+10693095-10696429 modbus: cs-server-id: "Slave ID: 247"
+10697670-10701004 modbus: sc-function: "Function 3: Read Holding Registers"
+10697670-10701004 modbus: cs-function: "Function 3: Read Holding Registers"
+10702246-10705580 modbus: sc-length: "Byte count: 2"
+10702246-10710156 modbus: cs-address: "Start at address 0x200 / 30513"
+10706822-10714731 modbus: sc-data: "0x0008 / 8"
+10711397-10719307 modbus: cs-length: "Read 2161 units of data"
+10715973-10723882 modbus: sc-crc: "CRC correct"
+10719307-10725133 modbus: cs-error: "Message too short or not finished"
+10888378-10891712 modbus: sc-server-id: "Slave ID: 247"
+10888378-10891712 modbus: cs-server-id: "Slave ID: 247"
+10893048-10896382 modbus: sc-function: "Function 3: Read Holding Registers"
+10893048-10896382 modbus: cs-function: "Function 3: Read Holding Registers"
+10897698-10901032 modbus: sc-length: "Byte count: 64"
+10897698-10905704 modbus: cs-address: "Start at address 0x4082 / 46515"
+10902370-10910354 modbus: sc-data: "0x8200 / 33280"
+10907020-10915025 modbus: cs-length: "Read 2 units of data"
+10911691-10919675 modbus: sc-data: "0x0265 / 613"
+10916341-10924347 modbus: cs-crc: "CRC correct"
+10919675-10925598 modbus: sc-error: "Message too short or not finished"
+10943297-10946631 modbus: sc-server-id: "Slave ID: 247"
+10943297-10946631 modbus: cs-server-id: "Slave ID: 247"
+10947873-10951207 modbus: sc-function: "Function 3: Read Holding Registers"
+10947873-10951207 modbus: cs-function: "Function 3: Read Holding Registers"
+10952449-10955783 modbus: sc-length: "Byte count: 4"
+10952449-10960358 modbus: cs-address: "Start at address 0x400 / 31025"
+10957024-10964934 modbus: sc-data: "0x0000 / 0"
+10961600-10969510 modbus: cs-length: "Read 0 units of data"
+10966176-10974085 modbus: sc-data: "0x0003 / 3"
+10970751-10978661 modbus: cs-error: "CRC should be 80 108"
+10975327-10983236 modbus: sc-crc: "CRC correct"
+10979902-10983236 modbus: cs-error: "Unknown function"
+11147846-11151180 modbus: sc-server-id: "Slave ID: 247"
+11147846-11151180 modbus: cs-server-id: "Slave ID: 247"
+11152516-11155850 modbus: sc-function: "Function 3: Read Holding Registers"
+11152516-11155850 modbus: cs-function: "Function 3: Read Holding Registers"
+11157166-11160500 modbus: sc-length: "Byte count: 0"
+11157166-11165171 modbus: cs-address: "Start at address 0x0 / 30001"
+11161837-11169821 modbus: sc-error: "CRC should be 192 194"
+11166487-11174493 modbus: cs-length: "Read 15 units of data"
+11171159-11179143 modbus: sc-error: "Message too long"
+11175809-11183815 modbus: cs-crc: "CRC correct"
+11201014-11204348 modbus: sc-server-id: "Slave ID: 247"
+11201014-11204348 modbus: cs-server-id: "Slave ID: 247"
+11205589-11208923 modbus: sc-function: "Function 3: Read Holding Registers"
+11205589-11208923 modbus: cs-function: "Function 3: Read Holding Registers"
+11210165-11213499 modbus: sc-length: "Byte count: 30"
+11210165-11218074 modbus: cs-address: "Start at address 0x1E00 / 37681"
+11214740-11222650 modbus: sc-data: "0x0000 / 0"
+11219316-11227226 modbus: cs-length: "Read 0 units of data"
+11223892-11231801 modbus: sc-data: "0x0000 / 0"
+11228467-11236377 modbus: cs-error: "CRC should be 87 116"
+11233043-11240952 modbus: sc-data: "0x41B7 / 16823"
+11237618-11240952 modbus: cs-error: "Unknown function"
+11242194-11245528 modbus: cs-error: "Unknown function"
+11242194-11250104 modbus: sc-data: "0xCBE0 / 52192"
+11246770-11250104 modbus: cs-error: "Unknown function"
+11251345-11254679 modbus: cs-error: "Unknown function"
+11251345-11259255 modbus: sc-data: "0x3E57 / 15959"
+11255921-11259255 modbus: cs-error: "Unknown function"
+11260497-11263831 modbus: cs-error: "Unknown function"
+11260497-11268406 modbus: sc-data: "0x9E9F / 40607"
+11265072-11268406 modbus: cs-error: "Unknown function"
+11269648-11272982 modbus: cs-error: "Unknown function"
+11269648-11277557 modbus: sc-data: "0x0000 / 0"
+11274223-11277557 modbus: cs-error: "Unknown function"
+11278799-11282133 modbus: cs-error: "Unknown function"
+11278799-11286709 modbus: sc-data: "0x0000 / 0"
+11283375-11286709 modbus: cs-error: "Unknown function"
+11287950-11291284 modbus: cs-error: "Unknown function"
+11287950-11295860 modbus: sc-data: "0x0000 / 0"
+11292526-11295860 modbus: cs-error: "Unknown function"
+11297101-11300435 modbus: cs-error: "Unknown function"
+11297101-11305011 modbus: sc-data: "0x0000 / 0"
+11301677-11305011 modbus: cs-error: "Unknown function"
+11306253-11309587 modbus: cs-error: "Unknown function"
+11306253-11314162 modbus: sc-data: "0x0000 / 0"
+11310828-11314162 modbus: cs-error: "Unknown function"
+11315404-11318738 modbus: cs-error: "Unknown function"
+11315404-11323313 modbus: sc-data: "0x0000 / 0"
+11319979-11323313 modbus: cs-error: "Unknown function"
+11324555-11327889 modbus: cs-error: "Unknown function"
+11324555-11332465 modbus: sc-data: "0x8000 / 32768"
+11329131-11332465 modbus: cs-error: "Unknown function"
+11333706-11337040 modbus: cs-error: "Unknown function"
+11333706-11341616 modbus: sc-data: "0x0008 / 8"
+11338282-11341616 modbus: cs-error: "Unknown function"
+11342858-11346192 modbus: cs-error: "Unknown function"
+11342858-11350767 modbus: sc-data: "0x0000 / 0"
+11347433-11350767 modbus: cs-error: "Unknown function"
+11352009-11355343 modbus: cs-error: "Unknown function"
+11352009-11359918 modbus: sc-crc: "CRC correct"
+11356584-11359918 modbus: cs-error: "Unknown function"
+11515119-11518453 modbus: sc-server-id: "Slave ID: 247"
+11515119-11518453 modbus: cs-server-id: "Slave ID: 247"
+11519790-11523124 modbus: sc-function: "Function 3: Read Holding Registers"
+11519790-11523124 modbus: cs-function: "Function 3: Read Holding Registers"
+11524440-11527774 modbus: sc-length: "Byte count: 0"
+11524440-11532445 modbus: cs-address: "Start at address 0xD / 30014"
+11529111-11537095 modbus: sc-error: "CRC should be 192 194"
+11533761-11541767 modbus: cs-length: "Read 1 units of data"
+11538433-11546417 modbus: sc-error: "Message too long"
+11543083-11551088 modbus: cs-crc: "CRC correct"
+11567946-11571280 modbus: sc-server-id: "Slave ID: 247"
+11567946-11571280 modbus: cs-server-id: "Slave ID: 247"
+11572522-11575856 modbus: sc-function: "Function 3: Read Holding Registers"
+11572522-11575856 modbus: cs-function: "Function 3: Read Holding Registers"
+11577098-11580432 modbus: sc-length: "Byte count: 2"
+11577098-11585007 modbus: cs-address: "Start at address 0x200 / 30513"
+11581673-11589583 modbus: sc-data: "0x0008 / 8"
+11586249-11594158 modbus: cs-length: "Read 2161 units of data"
+11590824-11598734 modbus: sc-crc: "CRC correct"
+11594158-11599985 modbus: cs-error: "Message too short or not finished"
+11763538-11766872 modbus: sc-server-id: "Slave ID: 247"
+11763538-11766872 modbus: cs-server-id: "Slave ID: 247"
+11768208-11771542 modbus: sc-function: "Function 3: Read Holding Registers"
+11768208-11771542 modbus: cs-function: "Function 3: Read Holding Registers"
+11772858-11776192 modbus: sc-length: "Byte count: 64"
+11772858-11780864 modbus: cs-address: "Start at address 0x4082 / 46515"
+11777530-11785514 modbus: sc-data: "0x8200 / 33280"
+11782180-11790185 modbus: cs-length: "Read 2 units of data"
+11786851-11794835 modbus: sc-data: "0x0265 / 613"
+11791501-11799507 modbus: cs-crc: "CRC correct"
+11794835-11800758 modbus: sc-error: "Message too short or not finished"
+11818435-11821769 modbus: sc-server-id: "Slave ID: 247"
+11818435-11821769 modbus: cs-server-id: "Slave ID: 247"
+11823011-11826345 modbus: sc-function: "Function 3: Read Holding Registers"
+11823011-11826345 modbus: cs-function: "Function 3: Read Holding Registers"
+11827586-11830920 modbus: sc-length: "Byte count: 4"
+11827586-11835496 modbus: cs-address: "Start at address 0x400 / 31025"
+11832162-11840072 modbus: sc-data: "0x0000 / 0"
+11836738-11844647 modbus: cs-length: "Read 0 units of data"
+11841313-11849223 modbus: sc-data: "0x0003 / 3"
+11845889-11853798 modbus: cs-error: "CRC should be 80 108"
+11850464-11858374 modbus: sc-crc: "CRC correct"
+11855040-11858374 modbus: cs-error: "Unknown function"
+12021875-12025209 modbus: sc-server-id: "Slave ID: 247"
+12021875-12025209 modbus: cs-server-id: "Slave ID: 247"
+12026546-12029880 modbus: sc-function: "Function 3: Read Holding Registers"
+12026546-12029880 modbus: cs-function: "Function 3: Read Holding Registers"
+12031196-12034530 modbus: sc-length: "Byte count: 0"
+12031196-12039201 modbus: cs-address: "Start at address 0x0 / 30001"
+12035867-12043851 modbus: sc-error: "CRC should be 192 194"
+12040517-12048523 modbus: cs-length: "Read 15 units of data"
+12045189-12053173 modbus: sc-error: "Message too long"
+12049839-12057844 modbus: cs-crc: "CRC correct"
+12075033-12078367 modbus: sc-server-id: "Slave ID: 247"
+12075033-12078367 modbus: cs-server-id: "Slave ID: 247"
+12079609-12082943 modbus: sc-function: "Function 3: Read Holding Registers"
+12079609-12082943 modbus: cs-function: "Function 3: Read Holding Registers"
+12084185-12087519 modbus: sc-length: "Byte count: 30"
+12084185-12092094 modbus: cs-address: "Start at address 0x1E00 / 37681"
+12088760-12096670 modbus: sc-data: "0x0000 / 0"
+12093336-12101245 modbus: cs-length: "Read 0 units of data"
+12097911-12105821 modbus: sc-data: "0x0000 / 0"
+12102487-12110397 modbus: cs-error: "CRC should be 87 116"
+12107063-12114972 modbus: sc-data: "0x41B7 / 16823"
+12111638-12114972 modbus: cs-error: "Unknown function"
+12116214-12119548 modbus: cs-error: "Unknown function"
+12116214-12124123 modbus: sc-data: "0xCBE0 / 52192"
+12120789-12124123 modbus: cs-error: "Unknown function"
+12125365-12128699 modbus: cs-error: "Unknown function"
+12125365-12133275 modbus: sc-data: "0x3E57 / 15959"
+12129941-12133275 modbus: cs-error: "Unknown function"
+12134516-12137850 modbus: cs-error: "Unknown function"
+12134516-12142426 modbus: sc-data: "0x9E9F / 40607"
+12139092-12142426 modbus: cs-error: "Unknown function"
+12143667-12147001 modbus: cs-error: "Unknown function"
+12143667-12151577 modbus: sc-data: "0x0000 / 0"
+12148243-12151577 modbus: cs-error: "Unknown function"
+12152819-12156153 modbus: cs-error: "Unknown function"
+12152819-12160728 modbus: sc-data: "0x0000 / 0"
+12157394-12160728 modbus: cs-error: "Unknown function"
+12161970-12165304 modbus: cs-error: "Unknown function"
+12161970-12169880 modbus: sc-data: "0x3AC3 / 15043"
+12166546-12169880 modbus: cs-error: "Unknown function"
+12171121-12174455 modbus: cs-error: "Unknown function"
+12171121-12179031 modbus: sc-data: "0x0FB5 / 4021"
+12175697-12179031 modbus: cs-error: "Unknown function"
+12180272-12183606 modbus: cs-error: "Unknown function"
+12180272-12188182 modbus: sc-data: "0x0000 / 0"
+12184848-12188182 modbus: cs-error: "Unknown function"
+12189424-12192758 modbus: cs-error: "Unknown function"
+12189424-12197333 modbus: sc-data: "0x0000 / 0"
+12193999-12197333 modbus: cs-error: "Unknown function"
+12198575-12201909 modbus: cs-error: "Unknown function"
+12198575-12206484 modbus: sc-data: "0x8000 / 32768"
+12203150-12206484 modbus: cs-error: "Unknown function"
+12207726-12211060 modbus: cs-error: "Unknown function"
+12207726-12215636 modbus: sc-data: "0x0008 / 8"
+12212302-12215636 modbus: cs-error: "Unknown function"
+12216877-12220211 modbus: cs-error: "Unknown function"
+12216877-12224787 modbus: sc-data: "0x0000 / 0"
+12221453-12224787 modbus: cs-error: "Unknown function"
+12226028-12229362 modbus: cs-error: "Unknown function"
+12226028-12233938 modbus: sc-crc: "CRC correct"
+12230604-12233938 modbus: cs-error: "Unknown function"
+12390408-12393742 modbus: sc-server-id: "Slave ID: 247"
+12390408-12393742 modbus: cs-server-id: "Slave ID: 247"
+12395078-12398412 modbus: sc-function: "Function 3: Read Holding Registers"
+12395078-12398412 modbus: cs-function: "Function 3: Read Holding Registers"
+12399728-12403062 modbus: sc-length: "Byte count: 0"
+12399728-12407733 modbus: cs-address: "Start at address 0xD / 30014"
+12404399-12412383 modbus: sc-error: "CRC should be 192 194"
+12409049-12417055 modbus: cs-length: "Read 1 units of data"
+12413721-12421705 modbus: sc-error: "Message too long"
+12418371-12426377 modbus: cs-crc: "CRC correct"
+12443240-12446574 modbus: sc-server-id: "Slave ID: 247"
+12443240-12446574 modbus: cs-server-id: "Slave ID: 247"
+12447816-12451150 modbus: sc-function: "Function 3: Read Holding Registers"
+12447816-12451150 modbus: cs-function: "Function 3: Read Holding Registers"
+12452391-12455725 modbus: sc-length: "Byte count: 2"
+12452391-12460301 modbus: cs-address: "Start at address 0x200 / 30513"
+12456967-12464876 modbus: sc-data: "0x0008 / 8"
+12461542-12469452 modbus: cs-length: "Read 2161 units of data"
+12466118-12474028 modbus: sc-crc: "CRC correct"
+12469452-12475279 modbus: cs-error: "Message too short or not finished"
+12638442-12641776 modbus: sc-server-id: "Slave ID: 247"
+12638442-12641776 modbus: cs-server-id: "Slave ID: 247"
+12643113-12646447 modbus: sc-function: "Function 3: Read Holding Registers"
+12643113-12646447 modbus: cs-function: "Function 3: Read Holding Registers"
+12647763-12651097 modbus: sc-length: "Byte count: 64"
+12647763-12655768 modbus: cs-address: "Start at address 0x4082 / 46515"
+12652434-12660418 modbus: sc-data: "0x8200 / 33280"
+12657084-12665090 modbus: cs-length: "Read 2 units of data"
+12661756-12669740 modbus: sc-data: "0x0265 / 613"
+12666406-12674411 modbus: cs-crc: "CRC correct"
+12669740-12675662 modbus: sc-error: "Message too short or not finished"
+12693339-12696673 modbus: sc-server-id: "Slave ID: 247"
+12693339-12696673 modbus: cs-server-id: "Slave ID: 247"
+12697914-12701248 modbus: sc-function: "Function 3: Read Holding Registers"
+12697914-12701248 modbus: cs-function: "Function 3: Read Holding Registers"
+12702490-12705824 modbus: sc-length: "Byte count: 4"
+12702490-12710400 modbus: cs-address: "Start at address 0x400 / 31025"
+12707066-12714975 modbus: sc-data: "0x0000 / 0"
+12711641-12719551 modbus: cs-length: "Read 0 units of data"
+12716217-12724126 modbus: sc-data: "0x0003 / 3"
+12720792-12728702 modbus: cs-error: "CRC should be 80 108"
+12725368-12733278 modbus: sc-crc: "CRC correct"
+12729944-12733278 modbus: cs-error: "Unknown function"
+12896907-12900241 modbus: sc-server-id: "Slave ID: 247"
+12896907-12900241 modbus: cs-server-id: "Slave ID: 247"
+12901578-12904912 modbus: sc-function: "Function 3: Read Holding Registers"
+12901578-12904912 modbus: cs-function: "Function 3: Read Holding Registers"
+12906228-12909562 modbus: sc-length: "Byte count: 0"
+12906228-12914233 modbus: cs-address: "Start at address 0x0 / 30001"
+12910899-12918883 modbus: sc-error: "CRC should be 192 194"
+12915549-12923555 modbus: cs-length: "Read 15 units of data"
+12920221-12928205 modbus: sc-error: "Message too long"
+12924871-12932876 modbus: cs-crc: "CRC correct"
+12950067-12953401 modbus: sc-server-id: "Slave ID: 247"
+12950067-12953401 modbus: cs-server-id: "Slave ID: 247"
+12954643-12957977 modbus: sc-function: "Function 3: Read Holding Registers"
+12954643-12957977 modbus: cs-function: "Function 3: Read Holding Registers"
+12959218-12962552 modbus: sc-length: "Byte count: 30"
+12959218-12967128 modbus: cs-address: "Start at address 0x1E00 / 37681"
+12963794-12971703 modbus: sc-data: "0x0000 / 0"
+12968369-12976279 modbus: cs-length: "Read 0 units of data"
+12972945-12980855 modbus: sc-data: "0x0000 / 0"
+12977521-12985430 modbus: cs-error: "CRC should be 87 116"
+12982096-12990006 modbus: sc-data: "0x41B7 / 16823"
+12986672-12990006 modbus: cs-error: "Unknown function"
+12991247-12994581 modbus: cs-error: "Unknown function"
+12991247-12999157 modbus: sc-data: "0xCBE0 / 52192"
+12995823-12999157 modbus: cs-error: "Unknown function"
+13000399-13003733 modbus: cs-error: "Unknown function"
+13000399-13008308 modbus: sc-data: "0x3E57 / 15959"
+13004974-13008308 modbus: cs-error: "Unknown function"
+13009550-13012884 modbus: cs-error: "Unknown function"
+13009550-13017460 modbus: sc-data: "0x9E9F / 40607"
+13014126-13017460 modbus: cs-error: "Unknown function"
+13018701-13022035 modbus: cs-error: "Unknown function"
+13018701-13026611 modbus: sc-data: "0x0000 / 0"
+13023277-13026611 modbus: cs-error: "Unknown function"
+13027852-13031186 modbus: cs-error: "Unknown function"
+13027852-13035762 modbus: sc-data: "0x0000 / 0"
+13032428-13035762 modbus: cs-error: "Unknown function"
+13037004-13040338 modbus: cs-error: "Unknown function"
+13037004-13044913 modbus: sc-data: "0x0000 / 0"
+13041579-13044913 modbus: cs-error: "Unknown function"
+13046155-13049489 modbus: cs-error: "Unknown function"
+13046155-13054064 modbus: sc-data: "0x0000 / 0"
+13050730-13054064 modbus: cs-error: "Unknown function"
+13055306-13058640 modbus: cs-error: "Unknown function"
+13055306-13063216 modbus: sc-data: "0x0000 / 0"
+13059882-13063216 modbus: cs-error: "Unknown function"
+13064457-13067791 modbus: cs-error: "Unknown function"
+13064457-13072367 modbus: sc-data: "0x0000 / 0"
+13069033-13072367 modbus: cs-error: "Unknown function"
+13073609-13076943 modbus: cs-error: "Unknown function"
+13073609-13081518 modbus: sc-data: "0x8000 / 32768"
+13078184-13081518 modbus: cs-error: "Unknown function"
+13082760-13086094 modbus: cs-error: "Unknown function"
+13082760-13090669 modbus: sc-data: "0x0008 / 8"
+13087335-13090669 modbus: cs-error: "Unknown function"
+13091911-13095245 modbus: cs-error: "Unknown function"
+13091911-13099821 modbus: sc-data: "0x0000 / 0"
+13096487-13099821 modbus: cs-error: "Unknown function"
+13101062-13104396 modbus: cs-error: "Unknown function"
+13101062-13108972 modbus: sc-crc: "CRC correct"
+13105638-13108972 modbus: cs-error: "Unknown function"
+13265120-13268454 modbus: sc-server-id: "Slave ID: 247"
+13265120-13268454 modbus: cs-server-id: "Slave ID: 247"
+13269790-13273124 modbus: sc-function: "Function 3: Read Holding Registers"
+13269790-13273124 modbus: cs-function: "Function 3: Read Holding Registers"
+13274440-13277774 modbus: sc-length: "Byte count: 0"
+13274440-13282446 modbus: cs-address: "Start at address 0xD / 30014"
+13279112-13287096 modbus: sc-error: "CRC should be 192 194"
+13283762-13291767 modbus: cs-length: "Read 1 units of data"
+13288433-13296417 modbus: sc-error: "Message too long"
+13293083-13301089 modbus: cs-crc: "CRC correct"
+13317962-13321296 modbus: sc-server-id: "Slave ID: 247"
+13317962-13321296 modbus: cs-server-id: "Slave ID: 247"
+13322537-13325871 modbus: sc-function: "Function 3: Read Holding Registers"
+13322537-13325871 modbus: cs-function: "Function 3: Read Holding Registers"
+13327113-13330447 modbus: sc-length: "Byte count: 2"
+13327113-13335023 modbus: cs-address: "Start at address 0x200 / 30513"
+13331689-13339598 modbus: sc-data: "0x0008 / 8"
+13336264-13344174 modbus: cs-length: "Read 2161 units of data"
+13340840-13348749 modbus: sc-crc: "CRC correct"
+13344174-13350000 modbus: cs-error: "Message too short or not finished"
+13513389-13516723 modbus: sc-server-id: "Slave ID: 247"
+13513389-13516723 modbus: cs-server-id: "Slave ID: 247"
+13518059-13521393 modbus: sc-function: "Function 3: Read Holding Registers"
+13518059-13521393 modbus: cs-function: "Function 3: Read Holding Registers"
+13522709-13526043 modbus: sc-length: "Byte count: 64"
+13522709-13530715 modbus: cs-address: "Start at address 0x4082 / 46515"
+13527381-13535365 modbus: sc-data: "0x8200 / 33280"
+13532031-13540037 modbus: cs-length: "Read 2 units of data"
+13536703-13544687 modbus: sc-data: "0x0265 / 613"
+13541353-13549358 modbus: cs-crc: "CRC correct"
+13544687-13550609 modbus: sc-error: "Message too short or not finished"
+13568294-13571628 modbus: sc-server-id: "Slave ID: 247"
+13568294-13571628 modbus: cs-server-id: "Slave ID: 247"
+13572870-13576204 modbus: sc-function: "Function 3: Read Holding Registers"
+13572870-13576204 modbus: cs-function: "Function 3: Read Holding Registers"
+13577446-13580780 modbus: sc-length: "Byte count: 4"
+13577446-13585355 modbus: cs-address: "Start at address 0x400 / 31025"
+13582021-13589931 modbus: sc-data: "0x0000 / 0"
+13586597-13594507 modbus: cs-length: "Read 0 units of data"
+13591173-13599082 modbus: sc-data: "0x0003 / 3"
+13595748-13603658 modbus: cs-error: "CRC should be 80 108"
+13600324-13608233 modbus: sc-crc: "CRC correct"
+13604899-13608233 modbus: cs-error: "Unknown function"
+13772942-13776276 modbus: sc-server-id: "Slave ID: 247"
+13772942-13776276 modbus: cs-server-id: "Slave ID: 247"
+13777613-13780947 modbus: sc-function: "Function 3: Read Holding Registers"
+13777613-13780947 modbus: cs-function: "Function 3: Read Holding Registers"
+13782263-13785597 modbus: sc-length: "Byte count: 0"
+13782263-13790268 modbus: cs-address: "Start at address 0x0 / 30001"
+13786934-13794918 modbus: sc-error: "CRC should be 192 194"
+13791584-13799590 modbus: cs-length: "Read 15 units of data"
+13796256-13804240 modbus: sc-error: "Message too long"
+13800906-13808911 modbus: cs-crc: "CRC correct"
+13826114-13829448 modbus: sc-server-id: "Slave ID: 247"
+13826114-13829448 modbus: cs-server-id: "Slave ID: 247"
+13830690-13834024 modbus: sc-function: "Function 3: Read Holding Registers"
+13830690-13834024 modbus: cs-function: "Function 3: Read Holding Registers"
+13835266-13838600 modbus: sc-length: "Byte count: 30"
+13835266-13843175 modbus: cs-address: "Start at address 0x1E00 / 37681"
+13839841-13847751 modbus: sc-data: "0x0000 / 0"
+13844417-13852327 modbus: cs-length: "Read 0 units of data"
+13848993-13856902 modbus: sc-data: "0x0000 / 0"
+13853568-13861478 modbus: cs-error: "CRC should be 87 116"
+13858144-13866053 modbus: sc-data: "0x41B7 / 16823"
+13862719-13866053 modbus: cs-error: "Unknown function"
+13867295-13870629 modbus: cs-error: "Unknown function"
+13867295-13875205 modbus: sc-data: "0xCBE0 / 52192"
+13871871-13875205 modbus: cs-error: "Unknown function"
+13876446-13879780 modbus: cs-error: "Unknown function"
+13876446-13884356 modbus: sc-data: "0x3E57 / 15959"
+13881022-13884356 modbus: cs-error: "Unknown function"
+13885598-13888932 modbus: cs-error: "Unknown function"
+13885598-13893507 modbus: sc-data: "0x9E9F / 40607"
+13890173-13893507 modbus: cs-error: "Unknown function"
+13894749-13898083 modbus: cs-error: "Unknown function"
+13894749-13902658 modbus: sc-data: "0x0000 / 0"
+13899324-13902658 modbus: cs-error: "Unknown function"
+13903900-13907234 modbus: cs-error: "Unknown function"
+13903900-13911810 modbus: sc-data: "0x0000 / 0"
+13908476-13911810 modbus: cs-error: "Unknown function"
+13913051-13916385 modbus: cs-error: "Unknown function"
+13913051-13920961 modbus: sc-data: "0x3C5B / 15451"
+13917627-13920961 modbus: cs-error: "Unknown function"
+13922202-13925536 modbus: cs-error: "Unknown function"
+13922202-13930112 modbus: sc-data: "0x71AC / 29100"
+13926778-13930112 modbus: cs-error: "Unknown function"
+13931354-13934688 modbus: cs-error: "Unknown function"
+13931354-13939263 modbus: sc-data: "0x0000 / 0"
+13935929-13939263 modbus: cs-error: "Unknown function"
+13940505-13943839 modbus: cs-error: "Unknown function"
+13940505-13948414 modbus: sc-data: "0x0000 / 0"
+13945080-13948414 modbus: cs-error: "Unknown function"
+13949656-13952990 modbus: cs-error: "Unknown function"
+13949656-13957566 modbus: sc-data: "0x8000 / 32768"
+13954232-13957566 modbus: cs-error: "Unknown function"
+13958807-13962141 modbus: cs-error: "Unknown function"
+13958807-13966717 modbus: sc-data: "0x0008 / 8"
+13963383-13966717 modbus: cs-error: "Unknown function"
+13967959-13971293 modbus: cs-error: "Unknown function"
+13967959-13975868 modbus: sc-data: "0x0000 / 0"
+13972534-13975868 modbus: cs-error: "Unknown function"
+13977110-13980444 modbus: cs-error: "Unknown function"
+13977110-13985019 modbus: sc-crc: "CRC correct"
+13981685-13985019 modbus: cs-error: "Unknown function"
+14140259-14143593 modbus: sc-server-id: "Slave ID: 247"
+14140259-14143593 modbus: cs-server-id: "Slave ID: 247"
+14144929-14148263 modbus: sc-function: "Function 3: Read Holding Registers"
+14144929-14148263 modbus: cs-function: "Function 3: Read Holding Registers"
+14149579-14152913 modbus: sc-length: "Byte count: 0"
+14149579-14157585 modbus: cs-address: "Start at address 0xD / 30014"
+14154251-14162235 modbus: sc-error: "CRC should be 192 194"
+14158901-14166906 modbus: cs-length: "Read 1 units of data"
+14163572-14171556 modbus: sc-error: "Message too long"
+14168222-14176228 modbus: cs-crc: "CRC correct"
+14193099-14196433 modbus: sc-server-id: "Slave ID: 247"
+14193099-14196433 modbus: cs-server-id: "Slave ID: 247"
+14197675-14201009 modbus: sc-function: "Function 3: Read Holding Registers"
+14197675-14201009 modbus: cs-function: "Function 3: Read Holding Registers"
+14202251-14205585 modbus: sc-length: "Byte count: 2"
+14202251-14210160 modbus: cs-address: "Start at address 0x200 / 30513"
+14206826-14214736 modbus: sc-data: "0x0008 / 8"
+14211402-14219311 modbus: cs-length: "Read 2161 units of data"
+14215977-14223887 modbus: sc-crc: "CRC correct"
+14219311-14225138 modbus: cs-error: "Message too short or not finished"
+14388635-14391969 modbus: sc-server-id: "Slave ID: 247"
+14388635-14391969 modbus: cs-server-id: "Slave ID: 247"
+14393305-14396639 modbus: sc-function: "Function 3: Read Holding Registers"
+14393305-14396639 modbus: cs-function: "Function 3: Read Holding Registers"
+14397955-14401289 modbus: sc-length: "Byte count: 64"
+14397955-14405961 modbus: cs-address: "Start at address 0x4082 / 46515"
+14402627-14410611 modbus: sc-data: "0x8200 / 33280"
+14407277-14415282 modbus: cs-length: "Read 2 units of data"
+14411948-14419932 modbus: sc-data: "0x0265 / 613"
+14416598-14424604 modbus: cs-crc: "CRC correct"
+14419932-14425855 modbus: sc-error: "Message too short or not finished"
+14443536-14446870 modbus: sc-server-id: "Slave ID: 247"
+14443536-14446870 modbus: cs-server-id: "Slave ID: 247"
+14448112-14451446 modbus: sc-function: "Function 3: Read Holding Registers"
+14448112-14451446 modbus: cs-function: "Function 3: Read Holding Registers"
+14452687-14456021 modbus: sc-length: "Byte count: 4"
+14452687-14460597 modbus: cs-address: "Start at address 0x400 / 31025"
+14457263-14465173 modbus: sc-data: "0x0000 / 0"
+14461839-14469748 modbus: cs-length: "Read 0 units of data"
+14466414-14474324 modbus: sc-data: "0x0003 / 3"
+14470990-14478899 modbus: cs-error: "CRC should be 80 108"
+14475565-14483475 modbus: sc-crc: "CRC correct"
+14480141-14483475 modbus: cs-error: "Unknown function"
+14647463-14650797 modbus: sc-server-id: "Slave ID: 247"
+14647463-14650797 modbus: cs-server-id: "Slave ID: 247"
+14652133-14655467 modbus: sc-function: "Function 3: Read Holding Registers"
+14652133-14655467 modbus: cs-function: "Function 3: Read Holding Registers"
+14656783-14660117 modbus: sc-length: "Byte count: 0"
+14656783-14664788 modbus: cs-address: "Start at address 0x0 / 30001"
+14661454-14669439 modbus: sc-error: "CRC should be 192 194"
+14666105-14674110 modbus: cs-length: "Read 15 units of data"
+14670776-14678760 modbus: sc-error: "Message too long"
+14675426-14683432 modbus: cs-crc: "CRC correct"
+14700628-14703962 modbus: sc-server-id: "Slave ID: 247"
+14700628-14703962 modbus: cs-server-id: "Slave ID: 247"
+14705204-14708538 modbus: sc-function: "Function 3: Read Holding Registers"
+14705204-14708538 modbus: cs-function: "Function 3: Read Holding Registers"
+14709779-14713113 modbus: sc-length: "Byte count: 30"
+14709779-14717689 modbus: cs-address: "Start at address 0x1E00 / 37681"
+14714355-14722265 modbus: sc-data: "0x0000 / 0"
+14718931-14726840 modbus: cs-length: "Read 0 units of data"
+14723506-14731416 modbus: sc-data: "0x0000 / 0"
+14728082-14735992 modbus: cs-error: "CRC should be 87 116"
+14732658-14740567 modbus: sc-data: "0x41B7 / 16823"
+14737233-14740567 modbus: cs-error: "Unknown function"
+14741809-14745143 modbus: cs-error: "Unknown function"
+14741809-14749718 modbus: sc-data: "0xCBE0 / 52192"
+14746384-14749718 modbus: cs-error: "Unknown function"
+14750960-14754294 modbus: cs-error: "Unknown function"
+14750960-14758870 modbus: sc-data: "0x3E57 / 15959"
+14755536-14758870 modbus: cs-error: "Unknown function"
+14760111-14763445 modbus: cs-error: "Unknown function"
+14760111-14768021 modbus: sc-data: "0x9E9F / 40607"
+14764687-14768021 modbus: cs-error: "Unknown function"
+14769262-14772596 modbus: cs-error: "Unknown function"
+14769262-14777172 modbus: sc-data: "0x0000 / 0"
+14773838-14777172 modbus: cs-error: "Unknown function"
+14778414-14781748 modbus: cs-error: "Unknown function"
+14778414-14786323 modbus: sc-data: "0x0000 / 0"
+14782989-14786323 modbus: cs-error: "Unknown function"
+14787565-14790899 modbus: cs-error: "Unknown function"
+14787565-14795475 modbus: sc-data: "0x3C5B / 15451"
+14792141-14795475 modbus: cs-error: "Unknown function"
+14796716-14800050 modbus: cs-error: "Unknown function"
+14796716-14804626 modbus: sc-data: "0x71AC / 29100"
+14801292-14804626 modbus: cs-error: "Unknown function"
+14805867-14809201 modbus: cs-error: "Unknown function"
+14805867-14813777 modbus: sc-data: "0x0000 / 0"
+14810443-14813777 modbus: cs-error: "Unknown function"
+14815019-14818353 modbus: cs-error: "Unknown function"
+14815019-14822928 modbus: sc-data: "0x0000 / 0"
+14819594-14822928 modbus: cs-error: "Unknown function"
+14824170-14827504 modbus: cs-error: "Unknown function"
+14824170-14832079 modbus: sc-data: "0x8000 / 32768"
+14828745-14832079 modbus: cs-error: "Unknown function"
+14833321-14836655 modbus: cs-error: "Unknown function"
+14833321-14841231 modbus: sc-data: "0x0008 / 8"
+14837897-14841231 modbus: cs-error: "Unknown function"
+14842472-14845806 modbus: cs-error: "Unknown function"
+14842472-14850382 modbus: sc-data: "0x0000 / 0"
+14847048-14850382 modbus: cs-error: "Unknown function"
+14851623-14854957 modbus: cs-error: "Unknown function"
+14851623-14859533 modbus: sc-crc: "CRC correct"
+14856199-14859533 modbus: cs-error: "Unknown function"
+15015184-15018518 modbus: sc-server-id: "Slave ID: 247"
+15015184-15018518 modbus: cs-server-id: "Slave ID: 247"
+15019855-15023189 modbus: sc-function: "Function 3: Read Holding Registers"
+15019855-15023189 modbus: cs-function: "Function 3: Read Holding Registers"
+15024505-15027839 modbus: sc-length: "Byte count: 0"
+15024505-15032510 modbus: cs-address: "Start at address 0xD / 30014"
+15029176-15037160 modbus: sc-error: "CRC should be 192 194"
+15033826-15041832 modbus: cs-length: "Read 1 units of data"
+15038498-15046482 modbus: sc-error: "Message too long"
+15043148-15051153 modbus: cs-crc: "CRC correct"
+15068003-15071337 modbus: sc-server-id: "Slave ID: 247"
+15068003-15071337 modbus: cs-server-id: "Slave ID: 247"
+15072579-15075913 modbus: sc-function: "Function 3: Read Holding Registers"
+15072579-15075913 modbus: cs-function: "Function 3: Read Holding Registers"
+15077154-15080488 modbus: sc-length: "Byte count: 2"
+15077154-15085064 modbus: cs-address: "Start at address 0x200 / 30513"
+15081730-15089639 modbus: sc-data: "0x0008 / 8"
+15086305-15094215 modbus: cs-length: "Read 2161 units of data"
+15090881-15098791 modbus: sc-crc: "CRC correct"
+15094215-15100042 modbus: cs-error: "Message too short or not finished"
+15263411-15266745 modbus: sc-server-id: "Slave ID: 247"
+15263411-15266745 modbus: cs-server-id: "Slave ID: 247"
+15268081-15271415 modbus: sc-function: "Function 3: Read Holding Registers"
+15268081-15271415 modbus: cs-function: "Function 3: Read Holding Registers"
+15272731-15276065 modbus: sc-length: "Byte count: 64"
+15272731-15280737 modbus: cs-address: "Start at address 0x4082 / 46515"
+15277403-15285387 modbus: sc-data: "0x8200 / 33280"
+15282053-15290058 modbus: cs-length: "Read 2 units of data"
+15286724-15294708 modbus: sc-data: "0x0265 / 613"
+15291374-15299380 modbus: cs-crc: "CRC correct"
+15294708-15300631 modbus: sc-error: "Message too short or not finished"
+15318336-15321670 modbus: sc-server-id: "Slave ID: 247"
+15318336-15321670 modbus: cs-server-id: "Slave ID: 247"
+15322911-15326245 modbus: sc-function: "Function 3: Read Holding Registers"
+15322911-15326245 modbus: cs-function: "Function 3: Read Holding Registers"
+15327487-15330821 modbus: sc-length: "Byte count: 4"
+15327487-15335397 modbus: cs-address: "Start at address 0x400 / 31025"
+15332063-15339972 modbus: sc-data: "0x0000 / 0"
+15336638-15344548 modbus: cs-length: "Read 0 units of data"
+15341214-15349123 modbus: sc-data: "0x0003 / 3"
+15345789-15353699 modbus: cs-error: "CRC should be 80 108"
+15350365-15358275 modbus: sc-crc: "CRC correct"
+15354941-15358275 modbus: cs-error: "Unknown function"
+15522730-15526064 modbus: sc-server-id: "Slave ID: 247"
+15522730-15526064 modbus: cs-server-id: "Slave ID: 247"
+15527400-15530734 modbus: sc-function: "Function 3: Read Holding Registers"
+15527400-15530734 modbus: cs-function: "Function 3: Read Holding Registers"
+15532050-15535384 modbus: sc-length: "Byte count: 0"
+15532050-15540055 modbus: cs-address: "Start at address 0x0 / 30001"
+15536721-15544706 modbus: sc-error: "CRC should be 192 194"
+15541372-15549377 modbus: cs-length: "Read 15 units of data"
+15546043-15554027 modbus: sc-error: "Message too long"
+15550693-15558698 modbus: cs-crc: "CRC correct"
+15575896-15579230 modbus: sc-server-id: "Slave ID: 247"
+15575896-15579230 modbus: cs-server-id: "Slave ID: 247"
+15580472-15583806 modbus: sc-function: "Function 3: Read Holding Registers"
+15580472-15583806 modbus: cs-function: "Function 3: Read Holding Registers"
+15585047-15588381 modbus: sc-length: "Byte count: 30"
+15585047-15592957 modbus: cs-address: "Start at address 0x1E00 / 37681"
+15589623-15597532 modbus: sc-data: "0x0000 / 0"
+15594198-15602108 modbus: cs-length: "Read 0 units of data"
+15598774-15606684 modbus: sc-data: "0x0000 / 0"
+15603350-15611259 modbus: cs-error: "CRC should be 87 116"
+15607925-15615835 modbus: sc-data: "0x41B7 / 16823"
+15612501-15615835 modbus: cs-error: "Unknown function"
+15617076-15620410 modbus: cs-error: "Unknown function"
+15617076-15624986 modbus: sc-data: "0xD0C0 / 53440"
+15621652-15624986 modbus: cs-error: "Unknown function"
+15626228-15629562 modbus: cs-error: "Unknown function"
+15626228-15634137 modbus: sc-data: "0x3E57 / 15959"
+15630803-15634137 modbus: cs-error: "Unknown function"
+15635379-15638713 modbus: cs-error: "Unknown function"
+15635379-15643289 modbus: sc-data: "0x9E9F / 40607"
+15639955-15643289 modbus: cs-error: "Unknown function"
+15644530-15647864 modbus: cs-error: "Unknown function"
+15644530-15652440 modbus: sc-data: "0x0000 / 0"
+15649106-15652440 modbus: cs-error: "Unknown function"
+15653681-15657015 modbus: cs-error: "Unknown function"
+15653681-15661591 modbus: sc-data: "0x0000 / 0"
+15658257-15661591 modbus: cs-error: "Unknown function"
+15662833-15666167 modbus: cs-error: "Unknown function"
+15662833-15670742 modbus: sc-data: "0x3C5B / 15451"
+15667408-15670742 modbus: cs-error: "Unknown function"
+15671984-15675318 modbus: cs-error: "Unknown function"
+15671984-15679893 modbus: sc-data: "0x71AC / 29100"
+15676559-15679893 modbus: cs-error: "Unknown function"
+15681135-15684469 modbus: cs-error: "Unknown function"
+15681135-15689045 modbus: sc-data: "0x0000 / 0"
+15685711-15689045 modbus: cs-error: "Unknown function"
+15690286-15693620 modbus: cs-error: "Unknown function"
+15690286-15698196 modbus: sc-data: "0x0000 / 0"
+15694862-15698196 modbus: cs-error: "Unknown function"
+15699437-15702771 modbus: cs-error: "Unknown function"
+15699437-15707347 modbus: sc-data: "0x8000 / 32768"
+15704013-15707347 modbus: cs-error: "Unknown function"
+15708589-15711923 modbus: cs-error: "Unknown function"
+15708589-15716498 modbus: sc-data: "0x0008 / 8"
+15713164-15716498 modbus: cs-error: "Unknown function"
+15717740-15721074 modbus: cs-error: "Unknown function"
+15717740-15725649 modbus: sc-data: "0x0000 / 0"
+15722315-15725649 modbus: cs-error: "Unknown function"
+15726891-15730225 modbus: cs-error: "Unknown function"
+15726891-15734801 modbus: sc-crc: "CRC correct"
+15731467-15734801 modbus: cs-error: "Unknown function"
+15893672-15897006 modbus: sc-server-id: "Slave ID: 247"
+15893672-15897006 modbus: cs-server-id: "Slave ID: 247"
+15898343-15901677 modbus: sc-function: "Function 3: Read Holding Registers"
+15898343-15901677 modbus: cs-function: "Function 3: Read Holding Registers"
+15902993-15906327 modbus: sc-length: "Byte count: 0"
+15902993-15910998 modbus: cs-address: "Start at address 0xD / 30014"
+15907664-15915648 modbus: sc-error: "CRC should be 192 194"
+15912314-15920320 modbus: cs-length: "Read 1 units of data"
+15916986-15924970 modbus: sc-error: "Message too long"
+15921636-15929641 modbus: cs-crc: "CRC correct"
+15946495-15949829 modbus: sc-server-id: "Slave ID: 247"
+15946495-15949829 modbus: cs-server-id: "Slave ID: 247"
+15951070-15954404 modbus: sc-function: "Function 3: Read Holding Registers"
+15951070-15954404 modbus: cs-function: "Function 3: Read Holding Registers"
+15955646-15958980 modbus: sc-length: "Byte count: 2"
+15955646-15963555 modbus: cs-address: "Start at address 0x200 / 30513"
+15960221-15968131 modbus: sc-data: "0x0008 / 8"
+15964797-15972706 modbus: cs-length: "Read 2161 units of data"
+15969372-15977282 modbus: sc-crc: "CRC correct"
+15972706-15978533 modbus: cs-error: "Message too short or not finished"
+16138379-16141713 modbus: sc-server-id: "Slave ID: 247"
+16138379-16141713 modbus: cs-server-id: "Slave ID: 247"
+16143049-16146383 modbus: sc-function: "Function 3: Read Holding Registers"
+16143049-16146383 modbus: cs-function: "Function 3: Read Holding Registers"
+16147700-16151034 modbus: sc-length: "Byte count: 64"
+16147700-16155705 modbus: cs-address: "Start at address 0x4082 / 46515"
+16152371-16160355 modbus: sc-data: "0x8200 / 33280"
+16157021-16165027 modbus: cs-length: "Read 2 units of data"
+16161693-16169677 modbus: sc-data: "0x0265 / 613"
+16166343-16174348 modbus: cs-crc: "CRC correct"
+16169677-16175599 modbus: sc-error: "Message too short or not finished"
+16193292-16196626 modbus: sc-server-id: "Slave ID: 247"
+16193292-16196626 modbus: cs-server-id: "Slave ID: 247"
+16197867-16201201 modbus: sc-function: "Function 3: Read Holding Registers"
+16197867-16201201 modbus: cs-function: "Function 3: Read Holding Registers"
+16202443-16205777 modbus: sc-length: "Byte count: 4"
+16202443-16210352 modbus: cs-address: "Start at address 0x400 / 31025"
+16207018-16214928 modbus: sc-data: "0x0000 / 0"
+16211594-16219504 modbus: cs-length: "Read 0 units of data"
+16216170-16224079 modbus: sc-data: "0x0003 / 3"
+16220745-16228655 modbus: cs-error: "CRC should be 80 108"
+16225321-16233230 modbus: sc-crc: "CRC correct"
+16229896-16233230 modbus: cs-error: "Unknown function"
+16397506-16400840 modbus: sc-server-id: "Slave ID: 247"
+16397506-16400840 modbus: cs-server-id: "Slave ID: 247"
+16402176-16405510 modbus: sc-function: "Function 3: Read Holding Registers"
+16402176-16405510 modbus: cs-function: "Function 3: Read Holding Registers"
+16406826-16410160 modbus: sc-length: "Byte count: 0"
+16406826-16414832 modbus: cs-address: "Start at address 0x0 / 30001"
+16411498-16419482 modbus: sc-error: "CRC should be 192 194"
+16416148-16424153 modbus: cs-length: "Read 15 units of data"
+16420819-16428803 modbus: sc-error: "Message too long"
+16425469-16433475 modbus: cs-crc: "CRC correct"
+16450670-16454004 modbus: sc-server-id: "Slave ID: 247"
+16450670-16454004 modbus: cs-server-id: "Slave ID: 247"
+16455245-16458579 modbus: sc-function: "Function 3: Read Holding Registers"
+16455245-16458579 modbus: cs-function: "Function 3: Read Holding Registers"
+16459821-16463155 modbus: sc-length: "Byte count: 30"
+16459821-16467730 modbus: cs-address: "Start at address 0x1E00 / 37681"
+16464396-16472306 modbus: sc-data: "0x0000 / 0"
+16468972-16476882 modbus: cs-length: "Read 0 units of data"
+16473548-16481457 modbus: sc-data: "0x0000 / 0"
+16478123-16486033 modbus: cs-error: "CRC should be 87 116"
+16482699-16490608 modbus: sc-data: "0x41B7 / 16823"
+16487274-16490608 modbus: cs-error: "Unknown function"
+16491850-16495184 modbus: cs-error: "Unknown function"
+16491850-16499760 modbus: sc-data: "0xD0C0 / 53440"
+16496426-16499760 modbus: cs-error: "Unknown function"
+16501001-16504335 modbus: cs-error: "Unknown function"
+16501001-16508911 modbus: sc-data: "0x3E57 / 15959"
+16505577-16508911 modbus: cs-error: "Unknown function"
+16510153-16513487 modbus: cs-error: "Unknown function"
+16510153-16518062 modbus: sc-data: "0x9E9F / 40607"
+16514728-16518062 modbus: cs-error: "Unknown function"
+16519304-16522638 modbus: cs-error: "Unknown function"
+16519304-16527213 modbus: sc-data: "0x0000 / 0"
+16523879-16527213 modbus: cs-error: "Unknown function"
+16528455-16531789 modbus: cs-error: "Unknown function"
+16528455-16536365 modbus: sc-data: "0x0000 / 0"
+16533031-16536365 modbus: cs-error: "Unknown function"
+16537606-16540940 modbus: cs-error: "Unknown function"
+16537606-16545516 modbus: sc-data: "0x3AC3 / 15043"
+16542182-16545516 modbus: cs-error: "Unknown function"
+16546757-16550091 modbus: cs-error: "Unknown function"
+16546757-16554667 modbus: sc-data: "0x0FB5 / 4021"
+16551333-16554667 modbus: cs-error: "Unknown function"
+16555909-16559243 modbus: cs-error: "Unknown function"
+16555909-16563818 modbus: sc-data: "0x0000 / 0"
+16560484-16563818 modbus: cs-error: "Unknown function"
+16565060-16568394 modbus: cs-error: "Unknown function"
+16565060-16572969 modbus: sc-data: "0x0000 / 0"
+16569635-16572969 modbus: cs-error: "Unknown function"
+16574211-16577545 modbus: cs-error: "Unknown function"
+16574211-16582121 modbus: sc-data: "0x8000 / 32768"
+16578787-16582121 modbus: cs-error: "Unknown function"
+16583362-16586696 modbus: cs-error: "Unknown function"
+16583362-16591272 modbus: sc-data: "0x0008 / 8"
+16587938-16591272 modbus: cs-error: "Unknown function"
+16592514-16595848 modbus: cs-error: "Unknown function"
+16592514-16600423 modbus: sc-data: "0x0000 / 0"
+16597089-16600423 modbus: cs-error: "Unknown function"
+16601665-16604999 modbus: cs-error: "Unknown function"
+16601665-16609574 modbus: sc-crc: "CRC correct"
+16606240-16609574 modbus: cs-error: "Unknown function"
diff --git a/decoder/test/modbus/flowmeter_target_15liter_per_min.output b/decoder/test/modbus/flowmeter_target_15liter_per_min.output
new file mode 100644 (file)
index 0000000..4e38919
--- /dev/null
@@ -0,0 +1,2269 @@
+19247-22581 modbus: sc-server-id: "Slave ID: 247"
+19247-22581 modbus: cs-server-id: "Slave ID: 247"
+23896-27230 modbus: sc-function: "Function 3: Read Holding Registers"
+23896-27230 modbus: cs-function: "Function 3: Read Holding Registers"
+28568-31902 modbus: sc-length: "Byte count: 64"
+28568-36552 modbus: cs-address: "Start at address 0x4082 / 46515"
+33218-41223 modbus: sc-data: "0x8200 / 33280"
+37889-45873 modbus: cs-length: "Read 2 units of data"
+42539-50545 modbus: sc-data: "0x0265 / 613"
+47211-55195 modbus: cs-crc: "CRC correct"
+50545-56446 modbus: sc-error: "Message too short or not finished"
+74128-77462 modbus: sc-server-id: "Slave ID: 247"
+74128-77462 modbus: cs-server-id: "Slave ID: 247"
+78704-82038 modbus: sc-function: "Function 3: Read Holding Registers"
+78704-82038 modbus: cs-function: "Function 3: Read Holding Registers"
+83279-86613 modbus: sc-length: "Byte count: 4"
+83279-91189 modbus: cs-address: "Start at address 0x400 / 31025"
+87855-95764 modbus: sc-data: "0x0000 / 0"
+92430-100340 modbus: cs-length: "Read 0 units of data"
+97006-104916 modbus: sc-data: "0x0003 / 3"
+101582-109491 modbus: cs-error: "CRC should be 80 108"
+106157-114067 modbus: sc-crc: "CRC correct"
+110733-114067 modbus: cs-error: "Unknown function"
+279120-282454 modbus: sc-server-id: "Slave ID: 247"
+279120-282454 modbus: cs-server-id: "Slave ID: 247"
+283769-287103 modbus: sc-function: "Function 3: Read Holding Registers"
+283769-287103 modbus: cs-function: "Function 3: Read Holding Registers"
+288441-291775 modbus: sc-length: "Byte count: 0"
+288441-296425 modbus: cs-address: "Start at address 0x0 / 30001"
+293091-301096 modbus: sc-error: "CRC should be 192 194"
+297762-305746 modbus: cs-length: "Read 15 units of data"
+302412-310418 modbus: sc-error: "Message too long"
+307084-315068 modbus: cs-crc: "CRC correct"
+332260-335594 modbus: sc-server-id: "Slave ID: 247"
+332260-335594 modbus: cs-server-id: "Slave ID: 247"
+336836-340170 modbus: sc-function: "Function 3: Read Holding Registers"
+336836-340170 modbus: cs-function: "Function 3: Read Holding Registers"
+341411-344745 modbus: sc-length: "Byte count: 30"
+341411-349321 modbus: cs-address: "Start at address 0x1E00 / 37681"
+345987-353896 modbus: sc-data: "0x0000 / 0"
+350562-358472 modbus: cs-length: "Read 0 units of data"
+355138-363048 modbus: sc-data: "0x0000 / 0"
+359714-367623 modbus: cs-error: "CRC should be 87 116"
+364289-372199 modbus: sc-data: "0x41B8 / 16824"
+368865-372199 modbus: cs-error: "Unknown function"
+373441-376775 modbus: cs-error: "Unknown function"
+373441-381350 modbus: sc-data: "0x0194 / 404"
+378016-381350 modbus: cs-error: "Unknown function"
+382592-385926 modbus: cs-error: "Unknown function"
+382592-390501 modbus: sc-data: "0x3E57 / 15959"
+387167-390501 modbus: cs-error: "Unknown function"
+391743-395077 modbus: cs-error: "Unknown function"
+391743-399653 modbus: sc-data: "0x9E9F / 40607"
+396319-399653 modbus: cs-error: "Unknown function"
+400894-404228 modbus: cs-error: "Unknown function"
+400894-408804 modbus: sc-data: "0x41A0 / 16800"
+405470-408804 modbus: cs-error: "Unknown function"
+410045-413379 modbus: cs-error: "Unknown function"
+410045-417955 modbus: sc-data: "0x0000 / 0"
+414621-417955 modbus: cs-error: "Unknown function"
+419197-422531 modbus: cs-error: "Unknown function"
+419197-427106 modbus: sc-data: "0x3AC3 / 15043"
+423772-427106 modbus: cs-error: "Unknown function"
+428348-431682 modbus: cs-error: "Unknown function"
+428348-436257 modbus: sc-data: "0x0FB5 / 4021"
+432923-436257 modbus: cs-error: "Unknown function"
+437499-440833 modbus: cs-error: "Unknown function"
+437499-445409 modbus: sc-data: "0x0000 / 0"
+442075-445409 modbus: cs-error: "Unknown function"
+446650-449984 modbus: cs-error: "Unknown function"
+446650-454560 modbus: sc-data: "0x0000 / 0"
+451226-454560 modbus: cs-error: "Unknown function"
+455802-459136 modbus: cs-error: "Unknown function"
+455802-463711 modbus: sc-data: "0x8000 / 32768"
+460377-463711 modbus: cs-error: "Unknown function"
+464953-468287 modbus: cs-error: "Unknown function"
+464953-472862 modbus: sc-data: "0x0008 / 8"
+469528-472862 modbus: cs-error: "Unknown function"
+474104-477438 modbus: cs-error: "Unknown function"
+474104-482014 modbus: sc-data: "0x0000 / 0"
+478680-482014 modbus: cs-error: "Unknown function"
+483255-486589 modbus: cs-error: "Unknown function"
+483255-491165 modbus: sc-crc: "CRC correct"
+487831-491165 modbus: cs-error: "Unknown function"
+645754-649088 modbus: sc-server-id: "Slave ID: 247"
+645754-649088 modbus: cs-server-id: "Slave ID: 247"
+650403-653737 modbus: sc-function: "Function 3: Read Holding Registers"
+650403-653737 modbus: cs-function: "Function 3: Read Holding Registers"
+655075-658409 modbus: sc-length: "Byte count: 0"
+655075-663059 modbus: cs-address: "Start at address 0xD / 30014"
+659725-667730 modbus: sc-error: "CRC should be 192 194"
+664396-672380 modbus: cs-length: "Read 1 units of data"
+669046-677052 modbus: sc-error: "Message too long"
+673718-681702 modbus: cs-crc: "CRC correct"
+698569-701903 modbus: sc-server-id: "Slave ID: 247"
+698569-701903 modbus: cs-server-id: "Slave ID: 247"
+703145-706479 modbus: sc-function: "Function 3: Read Holding Registers"
+703145-706479 modbus: cs-function: "Function 3: Read Holding Registers"
+707720-711054 modbus: sc-length: "Byte count: 2"
+707720-715630 modbus: cs-address: "Start at address 0x200 / 30513"
+712296-720205 modbus: sc-data: "0x0008 / 8"
+716871-724781 modbus: cs-length: "Read 2161 units of data"
+721447-729357 modbus: sc-crc: "CRC correct"
+724781-730608 modbus: cs-error: "Message too short or not finished"
+894365-897699 modbus: sc-server-id: "Slave ID: 247"
+894365-897699 modbus: cs-server-id: "Slave ID: 247"
+899014-902348 modbus: sc-function: "Function 3: Read Holding Registers"
+899014-902348 modbus: cs-function: "Function 3: Read Holding Registers"
+903685-907019 modbus: sc-length: "Byte count: 64"
+903685-911669 modbus: cs-address: "Start at address 0x4082 / 46515"
+908335-916341 modbus: sc-data: "0x8200 / 33280"
+913007-920991 modbus: cs-length: "Read 2 units of data"
+917657-925662 modbus: sc-data: "0x0265 / 613"
+922328-930312 modbus: cs-crc: "CRC correct"
+925662-931563 modbus: sc-error: "Message too short or not finished"
+950722-954056 modbus: sc-server-id: "Slave ID: 247"
+950722-954056 modbus: cs-server-id: "Slave ID: 247"
+955297-958631 modbus: sc-function: "Function 3: Read Holding Registers"
+955297-958631 modbus: cs-function: "Function 3: Read Holding Registers"
+959873-963207 modbus: sc-length: "Byte count: 4"
+959873-967782 modbus: cs-address: "Start at address 0x400 / 31025"
+964448-972358 modbus: sc-data: "0x0000 / 0"
+969024-976934 modbus: cs-length: "Read 0 units of data"
+973600-981509 modbus: sc-data: "0x0003 / 3"
+978175-986085 modbus: cs-error: "CRC should be 80 108"
+982751-990660 modbus: sc-crc: "CRC correct"
+987326-990660 modbus: cs-error: "Unknown function"
+1152681-1156015 modbus: sc-server-id: "Slave ID: 247"
+1152681-1156015 modbus: cs-server-id: "Slave ID: 247"
+1157330-1160664 modbus: sc-function: "Function 3: Read Holding Registers"
+1157330-1160664 modbus: cs-function: "Function 3: Read Holding Registers"
+1162001-1165335 modbus: sc-length: "Byte count: 0"
+1162001-1169985 modbus: cs-address: "Start at address 0x0 / 30001"
+1166651-1174657 modbus: sc-error: "CRC should be 192 194"
+1171323-1179307 modbus: cs-length: "Read 15 units of data"
+1175973-1183978 modbus: sc-error: "Message too long"
+1180644-1188628 modbus: cs-crc: "CRC correct"
+1205838-1209172 modbus: sc-server-id: "Slave ID: 247"
+1205838-1209172 modbus: cs-server-id: "Slave ID: 247"
+1210414-1213748 modbus: sc-function: "Function 3: Read Holding Registers"
+1210414-1213748 modbus: cs-function: "Function 3: Read Holding Registers"
+1214989-1218323 modbus: sc-length: "Byte count: 30"
+1214989-1222899 modbus: cs-address: "Start at address 0x1E00 / 37681"
+1219565-1227474 modbus: sc-data: "0x0000 / 0"
+1224140-1232050 modbus: cs-length: "Read 0 units of data"
+1228716-1236626 modbus: sc-data: "0x0000 / 0"
+1233292-1241201 modbus: cs-error: "CRC should be 87 116"
+1237867-1245777 modbus: sc-data: "0x41B8 / 16824"
+1242443-1245777 modbus: cs-error: "Unknown function"
+1247018-1250352 modbus: cs-error: "Unknown function"
+1247018-1254928 modbus: sc-data: "0x0194 / 404"
+1251594-1254928 modbus: cs-error: "Unknown function"
+1256170-1259504 modbus: cs-error: "Unknown function"
+1256170-1264079 modbus: sc-data: "0x3E57 / 15959"
+1260745-1264079 modbus: cs-error: "Unknown function"
+1265321-1268655 modbus: cs-error: "Unknown function"
+1265321-1273230 modbus: sc-data: "0x9E9F / 40607"
+1269896-1273230 modbus: cs-error: "Unknown function"
+1274472-1277806 modbus: cs-error: "Unknown function"
+1274472-1282382 modbus: sc-data: "0x41A0 / 16800"
+1279048-1282382 modbus: cs-error: "Unknown function"
+1283623-1286957 modbus: cs-error: "Unknown function"
+1283623-1291533 modbus: sc-data: "0x0000 / 0"
+1288199-1291533 modbus: cs-error: "Unknown function"
+1292774-1296108 modbus: cs-error: "Unknown function"
+1292774-1300684 modbus: sc-data: "0x0000 / 0"
+1297350-1300684 modbus: cs-error: "Unknown function"
+1301926-1305260 modbus: cs-error: "Unknown function"
+1301926-1309835 modbus: sc-data: "0x0000 / 0"
+1306501-1309835 modbus: cs-error: "Unknown function"
+1311077-1314411 modbus: cs-error: "Unknown function"
+1311077-1318987 modbus: sc-data: "0x0000 / 0"
+1315653-1318987 modbus: cs-error: "Unknown function"
+1320228-1323562 modbus: cs-error: "Unknown function"
+1320228-1328138 modbus: sc-data: "0x0000 / 0"
+1324804-1328138 modbus: cs-error: "Unknown function"
+1329379-1332713 modbus: cs-error: "Unknown function"
+1329379-1337289 modbus: sc-data: "0x8000 / 32768"
+1333955-1337289 modbus: cs-error: "Unknown function"
+1338531-1341865 modbus: cs-error: "Unknown function"
+1338531-1346440 modbus: sc-data: "0x0008 / 8"
+1343106-1346440 modbus: cs-error: "Unknown function"
+1347682-1351016 modbus: cs-error: "Unknown function"
+1347682-1355591 modbus: sc-data: "0x0000 / 0"
+1352257-1355591 modbus: cs-error: "Unknown function"
+1356833-1360167 modbus: cs-error: "Unknown function"
+1356833-1364743 modbus: sc-crc: "CRC correct"
+1361409-1364743 modbus: cs-error: "Unknown function"
+1521064-1524398 modbus: sc-server-id: "Slave ID: 247"
+1521064-1524398 modbus: cs-server-id: "Slave ID: 247"
+1525713-1529047 modbus: sc-function: "Function 3: Read Holding Registers"
+1525713-1529047 modbus: cs-function: "Function 3: Read Holding Registers"
+1530384-1533718 modbus: sc-length: "Byte count: 0"
+1530384-1538368 modbus: cs-address: "Start at address 0xD / 30014"
+1535034-1543040 modbus: sc-error: "CRC should be 192 194"
+1539706-1547690 modbus: cs-length: "Read 1 units of data"
+1544356-1552361 modbus: sc-error: "Message too long"
+1549027-1557011 modbus: cs-crc: "CRC correct"
+1573863-1577197 modbus: sc-server-id: "Slave ID: 247"
+1573863-1577197 modbus: cs-server-id: "Slave ID: 247"
+1578438-1581772 modbus: sc-function: "Function 3: Read Holding Registers"
+1578438-1581772 modbus: cs-function: "Function 3: Read Holding Registers"
+1583014-1586348 modbus: sc-length: "Byte count: 2"
+1583014-1590923 modbus: cs-address: "Start at address 0x200 / 30513"
+1587589-1595499 modbus: sc-data: "0x0008 / 8"
+1592165-1600075 modbus: cs-length: "Read 2161 units of data"
+1596741-1604650 modbus: sc-crc: "CRC correct"
+1600075-1605901 modbus: cs-error: "Message too short or not finished"
+1769397-1772731 modbus: sc-server-id: "Slave ID: 247"
+1769397-1772731 modbus: cs-server-id: "Slave ID: 247"
+1774046-1777380 modbus: sc-function: "Function 3: Read Holding Registers"
+1774046-1777380 modbus: cs-function: "Function 3: Read Holding Registers"
+1778717-1782051 modbus: sc-length: "Byte count: 64"
+1778717-1786701 modbus: cs-address: "Start at address 0x4082 / 46515"
+1783367-1791373 modbus: sc-data: "0x8200 / 33280"
+1788039-1796023 modbus: cs-length: "Read 2 units of data"
+1792689-1800694 modbus: sc-data: "0x0265 / 613"
+1797360-1805345 modbus: cs-crc: "CRC correct"
+1800694-1806596 modbus: sc-error: "Message too short or not finished"
+1824273-1827607 modbus: sc-server-id: "Slave ID: 247"
+1824273-1827607 modbus: cs-server-id: "Slave ID: 247"
+1828849-1832183 modbus: sc-function: "Function 3: Read Holding Registers"
+1828849-1832183 modbus: cs-function: "Function 3: Read Holding Registers"
+1833425-1836759 modbus: sc-length: "Byte count: 4"
+1833425-1841334 modbus: cs-address: "Start at address 0x400 / 31025"
+1838000-1845910 modbus: sc-data: "0x0000 / 0"
+1842576-1850485 modbus: cs-length: "Read 0 units of data"
+1847151-1855061 modbus: sc-data: "0x0003 / 3"
+1851727-1859637 modbus: cs-error: "CRC should be 80 108"
+1856303-1864212 modbus: sc-crc: "CRC correct"
+1860878-1864212 modbus: cs-error: "Unknown function"
+2028310-2031644 modbus: sc-server-id: "Slave ID: 247"
+2028310-2031644 modbus: cs-server-id: "Slave ID: 247"
+2032959-2036293 modbus: sc-function: "Function 3: Read Holding Registers"
+2032959-2036293 modbus: cs-function: "Function 3: Read Holding Registers"
+2037631-2040965 modbus: sc-length: "Byte count: 0"
+2037631-2045615 modbus: cs-address: "Start at address 0x0 / 30001"
+2042281-2050286 modbus: sc-error: "CRC should be 192 194"
+2046952-2054936 modbus: cs-length: "Read 15 units of data"
+2051602-2059608 modbus: sc-error: "Message too long"
+2056274-2064258 modbus: cs-crc: "CRC correct"
+2081444-2084778 modbus: sc-server-id: "Slave ID: 247"
+2081444-2084778 modbus: cs-server-id: "Slave ID: 247"
+2086019-2089353 modbus: sc-function: "Function 3: Read Holding Registers"
+2086019-2089353 modbus: cs-function: "Function 3: Read Holding Registers"
+2090595-2093929 modbus: sc-length: "Byte count: 30"
+2090595-2098504 modbus: cs-address: "Start at address 0x1E00 / 37681"
+2095170-2103080 modbus: sc-data: "0x0000 / 0"
+2099746-2107656 modbus: cs-length: "Read 0 units of data"
+2104322-2112231 modbus: sc-data: "0x0000 / 0"
+2108897-2116807 modbus: cs-error: "CRC should be 87 116"
+2113473-2121382 modbus: sc-data: "0x41B8 / 16824"
+2118048-2121382 modbus: cs-error: "Unknown function"
+2122624-2125958 modbus: cs-error: "Unknown function"
+2122624-2130534 modbus: sc-data: "0x0194 / 404"
+2127200-2130534 modbus: cs-error: "Unknown function"
+2131775-2135109 modbus: cs-error: "Unknown function"
+2131775-2139685 modbus: sc-data: "0x3E57 / 15959"
+2136351-2139685 modbus: cs-error: "Unknown function"
+2140926-2144260 modbus: cs-error: "Unknown function"
+2140926-2148836 modbus: sc-data: "0x9E9F / 40607"
+2145502-2148836 modbus: cs-error: "Unknown function"
+2150078-2153412 modbus: cs-error: "Unknown function"
+2150078-2157987 modbus: sc-data: "0x41A0 / 16800"
+2154653-2157987 modbus: cs-error: "Unknown function"
+2159229-2162563 modbus: cs-error: "Unknown function"
+2159229-2167138 modbus: sc-data: "0x0000 / 0"
+2163804-2167138 modbus: cs-error: "Unknown function"
+2168380-2171714 modbus: cs-error: "Unknown function"
+2168380-2176290 modbus: sc-data: "0x3AC3 / 15043"
+2172956-2176290 modbus: cs-error: "Unknown function"
+2177531-2180865 modbus: cs-error: "Unknown function"
+2177531-2185441 modbus: sc-data: "0x0FB5 / 4021"
+2182107-2185441 modbus: cs-error: "Unknown function"
+2186683-2190017 modbus: cs-error: "Unknown function"
+2186683-2194592 modbus: sc-data: "0x0000 / 0"
+2191258-2194592 modbus: cs-error: "Unknown function"
+2195834-2199168 modbus: cs-error: "Unknown function"
+2195834-2203743 modbus: sc-data: "0x0000 / 0"
+2200409-2203743 modbus: cs-error: "Unknown function"
+2204985-2208319 modbus: cs-error: "Unknown function"
+2204985-2212895 modbus: sc-data: "0x8000 / 32768"
+2209561-2212895 modbus: cs-error: "Unknown function"
+2214136-2217470 modbus: cs-error: "Unknown function"
+2214136-2222046 modbus: sc-data: "0x0008 / 8"
+2218712-2222046 modbus: cs-error: "Unknown function"
+2223287-2226621 modbus: cs-error: "Unknown function"
+2223287-2231197 modbus: sc-data: "0x0000 / 0"
+2227863-2231197 modbus: cs-error: "Unknown function"
+2232439-2235773 modbus: cs-error: "Unknown function"
+2232439-2240348 modbus: sc-crc: "CRC correct"
+2237014-2240348 modbus: cs-error: "Unknown function"
+2395861-2399195 modbus: sc-server-id: "Slave ID: 247"
+2395861-2399195 modbus: cs-server-id: "Slave ID: 247"
+2400510-2403844 modbus: sc-function: "Function 3: Read Holding Registers"
+2400510-2403844 modbus: cs-function: "Function 3: Read Holding Registers"
+2405182-2408516 modbus: sc-length: "Byte count: 0"
+2405182-2413166 modbus: cs-address: "Start at address 0xD / 30014"
+2409832-2417837 modbus: sc-error: "CRC should be 192 194"
+2414503-2422487 modbus: cs-length: "Read 1 units of data"
+2419153-2427159 modbus: sc-error: "Message too long"
+2423825-2431809 modbus: cs-crc: "CRC correct"
+2448662-2451996 modbus: sc-server-id: "Slave ID: 247"
+2448662-2451996 modbus: cs-server-id: "Slave ID: 247"
+2453238-2456572 modbus: sc-function: "Function 3: Read Holding Registers"
+2453238-2456572 modbus: cs-function: "Function 3: Read Holding Registers"
+2457814-2461148 modbus: sc-length: "Byte count: 2"
+2457814-2465723 modbus: cs-address: "Start at address 0x200 / 30513"
+2462389-2470299 modbus: sc-data: "0x0008 / 8"
+2466965-2474874 modbus: cs-length: "Read 2161 units of data"
+2471540-2479450 modbus: sc-crc: "CRC correct"
+2474874-2480701 modbus: cs-error: "Message too short or not finished"
+2644130-2647464 modbus: sc-server-id: "Slave ID: 247"
+2644130-2647464 modbus: cs-server-id: "Slave ID: 247"
+2648779-2652113 modbus: sc-function: "Function 3: Read Holding Registers"
+2648779-2652113 modbus: cs-function: "Function 3: Read Holding Registers"
+2653451-2656785 modbus: sc-length: "Byte count: 64"
+2653451-2661435 modbus: cs-address: "Start at address 0x4082 / 46515"
+2658101-2666106 modbus: sc-data: "0x8200 / 33280"
+2662772-2670756 modbus: cs-length: "Read 2 units of data"
+2667422-2675428 modbus: sc-data: "0x0265 / 613"
+2672094-2680078 modbus: cs-crc: "CRC correct"
+2675428-2681329 modbus: sc-error: "Message too short or not finished"
+2699021-2702355 modbus: sc-server-id: "Slave ID: 247"
+2699021-2702355 modbus: cs-server-id: "Slave ID: 247"
+2703597-2706931 modbus: sc-function: "Function 3: Read Holding Registers"
+2703597-2706931 modbus: cs-function: "Function 3: Read Holding Registers"
+2708172-2711506 modbus: sc-length: "Byte count: 4"
+2708172-2716082 modbus: cs-address: "Start at address 0x400 / 31025"
+2712748-2720657 modbus: sc-data: "0x0000 / 0"
+2717323-2725233 modbus: cs-length: "Read 0 units of data"
+2721899-2729809 modbus: sc-data: "0x0003 / 3"
+2726475-2734384 modbus: cs-error: "CRC should be 80 108"
+2731050-2738960 modbus: sc-crc: "CRC correct"
+2735626-2738960 modbus: cs-error: "Unknown function"
+2921857-2925191 modbus: sc-server-id: "Slave ID: 247"
+2921857-2925191 modbus: cs-server-id: "Slave ID: 247"
+2926506-2929840 modbus: sc-function: "Function 3: Read Holding Registers"
+2926506-2929840 modbus: cs-function: "Function 3: Read Holding Registers"
+2931178-2934512 modbus: sc-length: "Byte count: 0"
+2931178-2939162 modbus: cs-address: "Start at address 0x0 / 30001"
+2935828-2943833 modbus: sc-error: "CRC should be 192 194"
+2940499-2948484 modbus: cs-length: "Read 15 units of data"
+2945150-2953155 modbus: sc-error: "Message too long"
+2949821-2957805 modbus: cs-crc: "CRC correct"
+2975014-2978348 modbus: sc-server-id: "Slave ID: 247"
+2975014-2978348 modbus: cs-server-id: "Slave ID: 247"
+2979589-2982923 modbus: sc-function: "Function 3: Read Holding Registers"
+2979589-2982923 modbus: cs-function: "Function 3: Read Holding Registers"
+2984165-2987499 modbus: sc-length: "Byte count: 30"
+2984165-2992074 modbus: cs-address: "Start at address 0x1E00 / 37681"
+2988740-2996650 modbus: sc-data: "0x0000 / 0"
+2993316-3001226 modbus: cs-length: "Read 0 units of data"
+2997892-3005801 modbus: sc-data: "0x0000 / 0"
+3002467-3010377 modbus: cs-error: "CRC should be 87 116"
+3007043-3014953 modbus: sc-data: "0x41B8 / 16824"
+3011619-3014953 modbus: cs-error: "Unknown function"
+3016194-3019528 modbus: cs-error: "Unknown function"
+3016194-3024104 modbus: sc-data: "0x0194 / 404"
+3020770-3024104 modbus: cs-error: "Unknown function"
+3025345-3028679 modbus: cs-error: "Unknown function"
+3025345-3033255 modbus: sc-data: "0x3E57 / 15959"
+3029921-3033255 modbus: cs-error: "Unknown function"
+3034497-3037831 modbus: cs-error: "Unknown function"
+3034497-3042406 modbus: sc-data: "0x9E9F / 40607"
+3039072-3042406 modbus: cs-error: "Unknown function"
+3043648-3046982 modbus: cs-error: "Unknown function"
+3043648-3051557 modbus: sc-data: "0x41A0 / 16800"
+3048223-3051557 modbus: cs-error: "Unknown function"
+3052799-3056133 modbus: cs-error: "Unknown function"
+3052799-3060709 modbus: sc-data: "0x0000 / 0"
+3057375-3060709 modbus: cs-error: "Unknown function"
+3061950-3065284 modbus: cs-error: "Unknown function"
+3061950-3069860 modbus: sc-data: "0x0000 / 0"
+3066526-3069860 modbus: cs-error: "Unknown function"
+3071101-3074435 modbus: cs-error: "Unknown function"
+3071101-3079011 modbus: sc-data: "0x0000 / 0"
+3075677-3079011 modbus: cs-error: "Unknown function"
+3080253-3083587 modbus: cs-error: "Unknown function"
+3080253-3088162 modbus: sc-data: "0x0000 / 0"
+3084828-3088162 modbus: cs-error: "Unknown function"
+3089404-3092738 modbus: cs-error: "Unknown function"
+3089404-3097314 modbus: sc-data: "0x0000 / 0"
+3093980-3097314 modbus: cs-error: "Unknown function"
+3098555-3101889 modbus: cs-error: "Unknown function"
+3098555-3106465 modbus: sc-data: "0x8000 / 32768"
+3103131-3106465 modbus: cs-error: "Unknown function"
+3107706-3111040 modbus: cs-error: "Unknown function"
+3107706-3115616 modbus: sc-data: "0x0008 / 8"
+3112282-3115616 modbus: cs-error: "Unknown function"
+3116858-3120192 modbus: cs-error: "Unknown function"
+3116858-3124767 modbus: sc-data: "0x0000 / 0"
+3121433-3124767 modbus: cs-error: "Unknown function"
+3126009-3129343 modbus: cs-error: "Unknown function"
+3126009-3133918 modbus: sc-crc: "CRC correct"
+3130584-3133918 modbus: cs-error: "Unknown function"
+3334353-3337687 modbus: sc-server-id: "Slave ID: 247"
+3334353-3337687 modbus: cs-server-id: "Slave ID: 247"
+3339002-3342336 modbus: sc-function: "Function 3: Read Holding Registers"
+3339002-3342336 modbus: cs-function: "Function 3: Read Holding Registers"
+3343673-3347007 modbus: sc-length: "Byte count: 0"
+3343673-3351657 modbus: cs-address: "Start at address 0xD / 30014"
+3348323-3356328 modbus: sc-error: "CRC should be 192 194"
+3352994-3360979 modbus: cs-length: "Read 1 units of data"
+3357645-3365650 modbus: sc-error: "Message too long"
+3362316-3370300 modbus: cs-crc: "CRC correct"
+3387157-3390491 modbus: sc-server-id: "Slave ID: 247"
+3387157-3390491 modbus: cs-server-id: "Slave ID: 247"
+3391732-3395066 modbus: sc-function: "Function 3: Read Holding Registers"
+3391732-3395066 modbus: cs-function: "Function 3: Read Holding Registers"
+3396308-3399642 modbus: sc-length: "Byte count: 2"
+3396308-3404217 modbus: cs-address: "Start at address 0x200 / 30513"
+3400883-3408793 modbus: sc-data: "0x0008 / 8"
+3405459-3413369 modbus: cs-length: "Read 2161 units of data"
+3410035-3417944 modbus: sc-crc: "CRC correct"
+3413369-3419195 modbus: cs-error: "Message too short or not finished"
+3582323-3585657 modbus: sc-server-id: "Slave ID: 247"
+3582323-3585657 modbus: cs-server-id: "Slave ID: 247"
+3586972-3590306 modbus: sc-function: "Function 3: Read Holding Registers"
+3586972-3590306 modbus: cs-function: "Function 3: Read Holding Registers"
+3591644-3594978 modbus: sc-length: "Byte count: 64"
+3591644-3599628 modbus: cs-address: "Start at address 0x4082 / 46515"
+3596294-3604299 modbus: sc-data: "0x8200 / 33280"
+3600965-3608949 modbus: cs-length: "Read 2 units of data"
+3605615-3613621 modbus: sc-data: "0x0265 / 613"
+3610287-3618271 modbus: cs-crc: "CRC correct"
+3613621-3619522 modbus: sc-error: "Message too short or not finished"
+3637203-3640537 modbus: sc-server-id: "Slave ID: 247"
+3637203-3640537 modbus: cs-server-id: "Slave ID: 247"
+3641779-3645113 modbus: sc-function: "Function 3: Read Holding Registers"
+3641779-3645113 modbus: cs-function: "Function 3: Read Holding Registers"
+3646355-3649689 modbus: sc-length: "Byte count: 4"
+3646355-3654264 modbus: cs-address: "Start at address 0x400 / 31025"
+3650930-3658840 modbus: sc-data: "0x0000 / 0"
+3655506-3663415 modbus: cs-length: "Read 0 units of data"
+3660081-3667991 modbus: sc-data: "0x0003 / 3"
+3664657-3672567 modbus: cs-error: "CRC should be 80 108"
+3669233-3677142 modbus: sc-crc: "CRC correct"
+3673808-3677142 modbus: cs-error: "Unknown function"
+3834965-3838299 modbus: sc-server-id: "Slave ID: 247"
+3834965-3838299 modbus: cs-server-id: "Slave ID: 247"
+3839614-3842948 modbus: sc-function: "Function 16: Write Multiple Registers"
+3839614-3842948 modbus: cs-function: "Function 16: Write Multiple Registers"
+3844286-3852270 modbus: sc-address: "Start at address 0x6 / 30007"
+3844286-3852270 modbus: cs-address: "Start at address 0x6 / 30007"
+3853607-3861591 modbus: sc-data: "Write 2 Registers"
+3853607-3861591 modbus: cs-length: "Write 2 Registers"
+3862929-3866263 modbus: cs-length: "Byte count: 4"
+3862929-3870913 modbus: sc-error: "CRC should be 181 95"
+3867579-3870913 modbus: cs-data: "Value 0x41"
+3872250-3875584 modbus: sc-error: "Message too long"
+3872250-3875584 modbus: cs-data: "Value 0x70"
+3876900-3880234 modbus: sc-error: "Message too long"
+3876900-3880234 modbus: cs-data: "Value 0x0"
+3881572-3884906 modbus: sc-error: "Message too long"
+3881572-3884906 modbus: cs-data: "Value 0x0"
+3886222-3889556 modbus: sc-error: "Message too long"
+3890893-3894227 modbus: sc-error: "Message too long"
+3886222-3894227 modbus: cs-crc: "CRC correct"
+3911194-3914528 modbus: sc-server-id: "Slave ID: 247"
+3911194-3914528 modbus: cs-server-id: "Slave ID: 247"
+3915770-3919104 modbus: sc-function: "Function 16: Write Multiple Registers"
+3915770-3919104 modbus: cs-function: "Function 16: Write Multiple Registers"
+3920345-3928255 modbus: sc-address: "Start at address 0x6 / 30007"
+3920345-3928255 modbus: cs-address: "Start at address 0x6 / 30007"
+3929497-3937406 modbus: sc-data: "Write 2 Registers"
+3929497-3937406 modbus: cs-length: "Write 2 Registers"
+3938648-3941982 modbus: cs-error: "Bad byte count, is 181, should be 4"
+3938648-3946557 modbus: sc-crc: "CRC correct"
+3943223-3946557 modbus: cs-data: "Value 0x5F"
+4519364-4522698 modbus: sc-server-id: "Slave ID: 247"
+4519364-4522698 modbus: cs-server-id: "Slave ID: 247"
+4524034-4527368 modbus: sc-function: "Function 3: Read Holding Registers"
+4524034-4527368 modbus: cs-function: "Function 3: Read Holding Registers"
+4528684-4532018 modbus: sc-length: "Byte count: 0"
+4528684-4536690 modbus: cs-address: "Start at address 0x0 / 30001"
+4533356-4541340 modbus: sc-error: "CRC should be 192 194"
+4538006-4546011 modbus: cs-length: "Read 15 units of data"
+4542677-4550661 modbus: sc-error: "Message too long"
+4547327-4555333 modbus: cs-crc: "CRC correct"
+4572526-4575860 modbus: sc-server-id: "Slave ID: 247"
+4572526-4575860 modbus: cs-server-id: "Slave ID: 247"
+4577102-4580436 modbus: sc-function: "Function 3: Read Holding Registers"
+4577102-4580436 modbus: cs-function: "Function 3: Read Holding Registers"
+4581677-4585011 modbus: sc-length: "Byte count: 30"
+4581677-4589587 modbus: cs-address: "Start at address 0x1E00 / 37681"
+4586253-4594162 modbus: sc-data: "0x0000 / 0"
+4590828-4598738 modbus: cs-length: "Read 0 units of data"
+4595404-4603314 modbus: sc-data: "0x0000 / 0"
+4599980-4607889 modbus: cs-error: "CRC should be 87 116"
+4604555-4612465 modbus: sc-data: "0x41B8 / 16824"
+4609131-4612465 modbus: cs-error: "Unknown function"
+4613706-4617040 modbus: cs-error: "Unknown function"
+4613706-4621616 modbus: sc-data: "0x0194 / 404"
+4618282-4621616 modbus: cs-error: "Unknown function"
+4622858-4626192 modbus: cs-error: "Unknown function"
+4622858-4630767 modbus: sc-data: "0x3E57 / 15959"
+4627433-4630767 modbus: cs-error: "Unknown function"
+4632009-4635343 modbus: cs-error: "Unknown function"
+4632009-4639919 modbus: sc-data: "0x9E9F / 40607"
+4636585-4639919 modbus: cs-error: "Unknown function"
+4641160-4644494 modbus: cs-error: "Unknown function"
+4641160-4649070 modbus: sc-data: "0x4170 / 16752"
+4645736-4649070 modbus: cs-error: "Unknown function"
+4650311-4653645 modbus: cs-error: "Unknown function"
+4650311-4658221 modbus: sc-data: "0x0000 / 0"
+4654887-4658221 modbus: cs-error: "Unknown function"
+4659463-4662797 modbus: cs-error: "Unknown function"
+4659463-4667372 modbus: sc-data: "0x3C5B / 15451"
+4664038-4667372 modbus: cs-error: "Unknown function"
+4668614-4671948 modbus: cs-error: "Unknown function"
+4668614-4676523 modbus: sc-data: "0x71AC / 29100"
+4673189-4676523 modbus: cs-error: "Unknown function"
+4677765-4681099 modbus: cs-error: "Unknown function"
+4677765-4685675 modbus: sc-data: "0x0000 / 0"
+4682341-4685675 modbus: cs-error: "Unknown function"
+4686916-4690250 modbus: cs-error: "Unknown function"
+4686916-4694826 modbus: sc-data: "0x0000 / 0"
+4691492-4694826 modbus: cs-error: "Unknown function"
+4696067-4699401 modbus: cs-error: "Unknown function"
+4696067-4703977 modbus: sc-data: "0x8000 / 32768"
+4700643-4703977 modbus: cs-error: "Unknown function"
+4705219-4708553 modbus: cs-error: "Unknown function"
+4705219-4713128 modbus: sc-data: "0x0008 / 8"
+4709794-4713128 modbus: cs-error: "Unknown function"
+4714370-4717704 modbus: cs-error: "Unknown function"
+4714370-4722280 modbus: sc-data: "0x0000 / 0"
+4718946-4722280 modbus: cs-error: "Unknown function"
+4723521-4726855 modbus: cs-error: "Unknown function"
+4723521-4731431 modbus: sc-crc: "CRC correct"
+4728097-4731431 modbus: cs-error: "Unknown function"
+4898114-4901448 modbus: sc-server-id: "Slave ID: 247"
+4898114-4901448 modbus: cs-server-id: "Slave ID: 247"
+4902784-4906118 modbus: sc-function: "Function 3: Read Holding Registers"
+4902784-4906118 modbus: cs-function: "Function 3: Read Holding Registers"
+4907434-4910768 modbus: sc-length: "Byte count: 0"
+4907434-4915439 modbus: cs-address: "Start at address 0xD / 30014"
+4912105-4920090 modbus: sc-error: "CRC should be 192 194"
+4916756-4924761 modbus: cs-length: "Read 1 units of data"
+4921427-4929411 modbus: sc-error: "Message too long"
+4926077-4934083 modbus: cs-crc: "CRC correct"
+4950950-4954284 modbus: sc-server-id: "Slave ID: 247"
+4950950-4954284 modbus: cs-server-id: "Slave ID: 247"
+4955526-4958860 modbus: sc-function: "Function 3: Read Holding Registers"
+4955526-4958860 modbus: cs-function: "Function 3: Read Holding Registers"
+4960101-4963435 modbus: sc-length: "Byte count: 2"
+4960101-4968011 modbus: cs-address: "Start at address 0x200 / 30513"
+4964677-4972586 modbus: sc-data: "0x0008 / 8"
+4969252-4977162 modbus: cs-length: "Read 2161 units of data"
+4973828-4981738 modbus: sc-crc: "CRC correct"
+4977162-4982989 modbus: cs-error: "Message too short or not finished"
+5144143-5147477 modbus: sc-server-id: "Slave ID: 247"
+5144143-5147477 modbus: cs-server-id: "Slave ID: 247"
+5148813-5152147 modbus: sc-function: "Function 3: Read Holding Registers"
+5148813-5152147 modbus: cs-function: "Function 3: Read Holding Registers"
+5153464-5156798 modbus: sc-length: "Byte count: 64"
+5153464-5161469 modbus: cs-address: "Start at address 0x4082 / 46515"
+5158135-5166119 modbus: sc-data: "0x8200 / 33280"
+5162785-5170791 modbus: cs-length: "Read 2 units of data"
+5167457-5175441 modbus: sc-data: "0x0265 / 613"
+5172107-5180112 modbus: cs-crc: "CRC correct"
+5175441-5181363 modbus: sc-error: "Message too short or not finished"
+5199047-5202381 modbus: sc-server-id: "Slave ID: 247"
+5199047-5202381 modbus: cs-server-id: "Slave ID: 247"
+5203622-5206956 modbus: sc-function: "Function 3: Read Holding Registers"
+5203622-5206956 modbus: cs-function: "Function 3: Read Holding Registers"
+5208198-5211532 modbus: sc-length: "Byte count: 4"
+5208198-5216108 modbus: cs-address: "Start at address 0x400 / 31025"
+5212774-5220683 modbus: sc-data: "0x0000 / 0"
+5217349-5225259 modbus: cs-length: "Read 0 units of data"
+5221925-5229834 modbus: sc-data: "0x0003 / 3"
+5226500-5234410 modbus: cs-error: "CRC should be 80 108"
+5231076-5238986 modbus: sc-crc: "CRC correct"
+5235652-5238986 modbus: cs-error: "Unknown function"
+5405979-5409313 modbus: sc-server-id: "Slave ID: 247"
+5405979-5409313 modbus: cs-server-id: "Slave ID: 247"
+5410649-5413983 modbus: sc-function: "Function 3: Read Holding Registers"
+5410649-5413983 modbus: cs-function: "Function 3: Read Holding Registers"
+5415299-5418633 modbus: sc-length: "Byte count: 0"
+5415299-5423305 modbus: cs-address: "Start at address 0x0 / 30001"
+5419971-5427955 modbus: sc-error: "CRC should be 192 194"
+5424621-5432626 modbus: cs-length: "Read 15 units of data"
+5429292-5437276 modbus: sc-error: "Message too long"
+5433942-5441948 modbus: cs-crc: "CRC correct"
+5459155-5462489 modbus: sc-server-id: "Slave ID: 247"
+5459155-5462489 modbus: cs-server-id: "Slave ID: 247"
+5463730-5467064 modbus: sc-function: "Function 3: Read Holding Registers"
+5463730-5467064 modbus: cs-function: "Function 3: Read Holding Registers"
+5468306-5471640 modbus: sc-length: "Byte count: 30"
+5468306-5476216 modbus: cs-address: "Start at address 0x1E00 / 37681"
+5472882-5480791 modbus: sc-data: "0x0000 / 0"
+5477457-5485367 modbus: cs-length: "Read 0 units of data"
+5482033-5489942 modbus: sc-data: "0x0000 / 0"
+5486608-5494518 modbus: cs-error: "CRC should be 87 116"
+5491184-5499094 modbus: sc-data: "0x41B8 / 16824"
+5495760-5499094 modbus: cs-error: "Unknown function"
+5500335-5503669 modbus: cs-error: "Unknown function"
+5500335-5508245 modbus: sc-data: "0x0194 / 404"
+5504911-5508245 modbus: cs-error: "Unknown function"
+5509486-5512820 modbus: cs-error: "Unknown function"
+5509486-5517396 modbus: sc-data: "0x3E57 / 15959"
+5514062-5517396 modbus: cs-error: "Unknown function"
+5518638-5521972 modbus: cs-error: "Unknown function"
+5518638-5526547 modbus: sc-data: "0x9E9F / 40607"
+5523213-5526547 modbus: cs-error: "Unknown function"
+5527789-5531123 modbus: cs-error: "Unknown function"
+5527789-5535698 modbus: sc-data: "0x4170 / 16752"
+5532364-5535698 modbus: cs-error: "Unknown function"
+5536940-5540274 modbus: cs-error: "Unknown function"
+5536940-5544850 modbus: sc-data: "0x0000 / 0"
+5541516-5544850 modbus: cs-error: "Unknown function"
+5546091-5549425 modbus: cs-error: "Unknown function"
+5546091-5554001 modbus: sc-data: "0x3AC3 / 15043"
+5550667-5554001 modbus: cs-error: "Unknown function"
+5555243-5558577 modbus: cs-error: "Unknown function"
+5555243-5563152 modbus: sc-data: "0x0FB5 / 4021"
+5559818-5563152 modbus: cs-error: "Unknown function"
+5564394-5567728 modbus: cs-error: "Unknown function"
+5564394-5572303 modbus: sc-data: "0x0000 / 0"
+5568969-5572303 modbus: cs-error: "Unknown function"
+5573545-5576879 modbus: cs-error: "Unknown function"
+5573545-5581455 modbus: sc-data: "0x0000 / 0"
+5578121-5581455 modbus: cs-error: "Unknown function"
+5582696-5586030 modbus: cs-error: "Unknown function"
+5582696-5590606 modbus: sc-data: "0x8000 / 32768"
+5587272-5590606 modbus: cs-error: "Unknown function"
+5591847-5595181 modbus: cs-error: "Unknown function"
+5591847-5599757 modbus: sc-data: "0x0008 / 8"
+5596423-5599757 modbus: cs-error: "Unknown function"
+5600999-5604333 modbus: cs-error: "Unknown function"
+5600999-5608908 modbus: sc-data: "0x0000 / 0"
+5605574-5608908 modbus: cs-error: "Unknown function"
+5610150-5613484 modbus: cs-error: "Unknown function"
+5610150-5618059 modbus: sc-crc: "CRC correct"
+5614725-5618059 modbus: cs-error: "Unknown function"
+5771247-5774581 modbus: sc-server-id: "Slave ID: 247"
+5771247-5774581 modbus: cs-server-id: "Slave ID: 247"
+5775918-5779252 modbus: sc-function: "Function 3: Read Holding Registers"
+5775918-5779252 modbus: cs-function: "Function 3: Read Holding Registers"
+5780568-5783902 modbus: sc-length: "Byte count: 0"
+5780568-5788573 modbus: cs-address: "Start at address 0xD / 30014"
+5785239-5793223 modbus: sc-error: "CRC should be 192 194"
+5789889-5797895 modbus: cs-length: "Read 1 units of data"
+5794561-5802545 modbus: sc-error: "Message too long"
+5799211-5807216 modbus: cs-crc: "CRC correct"
+5824086-5827420 modbus: sc-server-id: "Slave ID: 247"
+5824086-5827420 modbus: cs-server-id: "Slave ID: 247"
+5828661-5831995 modbus: sc-function: "Function 3: Read Holding Registers"
+5828661-5831995 modbus: cs-function: "Function 3: Read Holding Registers"
+5833237-5836571 modbus: sc-length: "Byte count: 2"
+5833237-5841147 modbus: cs-address: "Start at address 0x200 / 30513"
+5837813-5845722 modbus: sc-data: "0x0008 / 8"
+5842388-5850298 modbus: cs-length: "Read 2161 units of data"
+5846964-5854873 modbus: sc-crc: "CRC correct"
+5850298-5856124 modbus: cs-error: "Message too short or not finished"
+6019879-6023213 modbus: sc-server-id: "Slave ID: 247"
+6019879-6023213 modbus: cs-server-id: "Slave ID: 247"
+6024549-6027883 modbus: sc-function: "Function 3: Read Holding Registers"
+6024549-6027883 modbus: cs-function: "Function 3: Read Holding Registers"
+6029200-6032534 modbus: sc-length: "Byte count: 64"
+6029200-6037205 modbus: cs-address: "Start at address 0x4082 / 46515"
+6033871-6041855 modbus: sc-data: "0x8200 / 33280"
+6038521-6046527 modbus: cs-length: "Read 2 units of data"
+6043193-6051177 modbus: sc-data: "0x0265 / 613"
+6047843-6055848 modbus: cs-crc: "CRC correct"
+6051177-6057099 modbus: sc-error: "Message too short or not finished"
+6074782-6078116 modbus: sc-server-id: "Slave ID: 247"
+6074782-6078116 modbus: cs-server-id: "Slave ID: 247"
+6079358-6082692 modbus: sc-function: "Function 3: Read Holding Registers"
+6079358-6082692 modbus: cs-function: "Function 3: Read Holding Registers"
+6083934-6087268 modbus: sc-length: "Byte count: 4"
+6083934-6091843 modbus: cs-address: "Start at address 0x400 / 31025"
+6088509-6096419 modbus: sc-data: "0x0000 / 0"
+6093085-6100994 modbus: cs-length: "Read 0 units of data"
+6097660-6105570 modbus: sc-data: "0x0003 / 3"
+6102236-6110146 modbus: cs-error: "CRC should be 80 108"
+6106812-6114721 modbus: sc-crc: "CRC correct"
+6111387-6114721 modbus: cs-error: "Unknown function"
+6279198-6282532 modbus: sc-server-id: "Slave ID: 247"
+6279198-6282532 modbus: cs-server-id: "Slave ID: 247"
+6283868-6287202 modbus: sc-function: "Function 3: Read Holding Registers"
+6283868-6287202 modbus: cs-function: "Function 3: Read Holding Registers"
+6288518-6291852 modbus: sc-length: "Byte count: 0"
+6288518-6296524 modbus: cs-address: "Start at address 0x0 / 30001"
+6293190-6301174 modbus: sc-error: "CRC should be 192 194"
+6297840-6305845 modbus: cs-length: "Read 15 units of data"
+6302511-6310495 modbus: sc-error: "Message too long"
+6307161-6315167 modbus: cs-crc: "CRC correct"
+6332368-6335702 modbus: sc-server-id: "Slave ID: 247"
+6332368-6335702 modbus: cs-server-id: "Slave ID: 247"
+6336944-6340278 modbus: sc-function: "Function 3: Read Holding Registers"
+6336944-6340278 modbus: cs-function: "Function 3: Read Holding Registers"
+6341520-6344854 modbus: sc-length: "Byte count: 30"
+6341520-6349429 modbus: cs-address: "Start at address 0x1E00 / 37681"
+6346095-6354005 modbus: sc-data: "0x0000 / 0"
+6350671-6358581 modbus: cs-length: "Read 0 units of data"
+6355247-6363156 modbus: sc-data: "0x0000 / 0"
+6359822-6367732 modbus: cs-error: "CRC should be 87 116"
+6364398-6372307 modbus: sc-data: "0x41B8 / 16824"
+6368973-6372307 modbus: cs-error: "Unknown function"
+6373549-6376883 modbus: cs-error: "Unknown function"
+6373549-6381459 modbus: sc-data: "0x0194 / 404"
+6378125-6381459 modbus: cs-error: "Unknown function"
+6382700-6386034 modbus: cs-error: "Unknown function"
+6382700-6390610 modbus: sc-data: "0x3E57 / 15959"
+6387276-6390610 modbus: cs-error: "Unknown function"
+6391851-6395185 modbus: cs-error: "Unknown function"
+6391851-6399761 modbus: sc-data: "0x9E9F / 40607"
+6396427-6399761 modbus: cs-error: "Unknown function"
+6401003-6404337 modbus: cs-error: "Unknown function"
+6401003-6408912 modbus: sc-data: "0x4170 / 16752"
+6405578-6408912 modbus: cs-error: "Unknown function"
+6410154-6413488 modbus: cs-error: "Unknown function"
+6410154-6418064 modbus: sc-data: "0x0000 / 0"
+6414730-6418064 modbus: cs-error: "Unknown function"
+6419305-6422639 modbus: cs-error: "Unknown function"
+6419305-6427215 modbus: sc-data: "0x3C5B / 15451"
+6423881-6427215 modbus: cs-error: "Unknown function"
+6428456-6431790 modbus: cs-error: "Unknown function"
+6428456-6436366 modbus: sc-data: "0x71AC / 29100"
+6433032-6436366 modbus: cs-error: "Unknown function"
+6437608-6440942 modbus: cs-error: "Unknown function"
+6437608-6445517 modbus: sc-data: "0x0000 / 0"
+6442183-6445517 modbus: cs-error: "Unknown function"
+6446759-6450093 modbus: cs-error: "Unknown function"
+6446759-6454668 modbus: sc-data: "0x0000 / 0"
+6451334-6454668 modbus: cs-error: "Unknown function"
+6455910-6459244 modbus: cs-error: "Unknown function"
+6455910-6463820 modbus: sc-data: "0x8000 / 32768"
+6460486-6463820 modbus: cs-error: "Unknown function"
+6465061-6468395 modbus: cs-error: "Unknown function"
+6465061-6472971 modbus: sc-data: "0x0008 / 8"
+6469637-6472971 modbus: cs-error: "Unknown function"
+6474212-6477546 modbus: cs-error: "Unknown function"
+6474212-6482122 modbus: sc-data: "0x0000 / 0"
+6478788-6482122 modbus: cs-error: "Unknown function"
+6483364-6486698 modbus: cs-error: "Unknown function"
+6483364-6491273 modbus: sc-crc: "CRC correct"
+6487939-6491273 modbus: cs-error: "Unknown function"
+6646301-6649635 modbus: sc-server-id: "Slave ID: 247"
+6646301-6649635 modbus: cs-server-id: "Slave ID: 247"
+6650971-6654305 modbus: sc-function: "Function 3: Read Holding Registers"
+6650971-6654305 modbus: cs-function: "Function 3: Read Holding Registers"
+6655621-6658955 modbus: sc-length: "Byte count: 0"
+6655621-6663627 modbus: cs-address: "Start at address 0xD / 30014"
+6660293-6668277 modbus: sc-error: "CRC should be 192 194"
+6664943-6672948 modbus: cs-length: "Read 1 units of data"
+6669614-6677598 modbus: sc-error: "Message too long"
+6674264-6682270 modbus: cs-crc: "CRC correct"
+6699119-6702453 modbus: sc-server-id: "Slave ID: 247"
+6699119-6702453 modbus: cs-server-id: "Slave ID: 247"
+6703695-6707029 modbus: sc-function: "Function 3: Read Holding Registers"
+6703695-6707029 modbus: cs-function: "Function 3: Read Holding Registers"
+6708271-6711605 modbus: sc-length: "Byte count: 2"
+6708271-6716180 modbus: cs-address: "Start at address 0x200 / 30513"
+6712846-6720756 modbus: sc-data: "0x0008 / 8"
+6717422-6725331 modbus: cs-length: "Read 2161 units of data"
+6721997-6729907 modbus: sc-crc: "CRC correct"
+6725331-6731158 modbus: cs-error: "Message too short or not finished"
+6894378-6897712 modbus: sc-server-id: "Slave ID: 247"
+6894378-6897712 modbus: cs-server-id: "Slave ID: 247"
+6899049-6902383 modbus: sc-function: "Function 3: Read Holding Registers"
+6899049-6902383 modbus: cs-function: "Function 3: Read Holding Registers"
+6903698-6907032 modbus: sc-length: "Byte count: 64"
+6903698-6911704 modbus: cs-address: "Start at address 0x4082 / 46515"
+6908370-6916354 modbus: sc-data: "0x8200 / 33280"
+6913020-6921026 modbus: cs-length: "Read 2 units of data"
+6917692-6925676 modbus: sc-data: "0x0265 / 613"
+6922342-6930347 modbus: cs-crc: "CRC correct"
+6925676-6931598 modbus: sc-error: "Message too short or not finished"
+6950544-6953878 modbus: sc-server-id: "Slave ID: 247"
+6950544-6953878 modbus: cs-server-id: "Slave ID: 247"
+6955120-6958454 modbus: sc-function: "Function 3: Read Holding Registers"
+6955120-6958454 modbus: cs-function: "Function 3: Read Holding Registers"
+6959695-6963029 modbus: sc-length: "Byte count: 4"
+6959695-6967605 modbus: cs-address: "Start at address 0x400 / 31025"
+6964271-6972180 modbus: sc-data: "0x0000 / 0"
+6968846-6976756 modbus: cs-length: "Read 0 units of data"
+6973422-6981332 modbus: sc-data: "0x0003 / 3"
+6977998-6985907 modbus: cs-error: "CRC should be 80 108"
+6982573-6990483 modbus: sc-crc: "CRC correct"
+6987149-6990483 modbus: cs-error: "Unknown function"
+7153633-7156967 modbus: sc-server-id: "Slave ID: 247"
+7153633-7156967 modbus: cs-server-id: "Slave ID: 247"
+7158303-7161637 modbus: sc-function: "Function 3: Read Holding Registers"
+7158303-7161637 modbus: cs-function: "Function 3: Read Holding Registers"
+7162953-7166287 modbus: sc-length: "Byte count: 0"
+7162953-7170958 modbus: cs-address: "Start at address 0x0 / 30001"
+7167624-7175609 modbus: sc-error: "CRC should be 192 194"
+7172275-7180280 modbus: cs-length: "Read 15 units of data"
+7176946-7184930 modbus: sc-error: "Message too long"
+7181596-7189602 modbus: cs-crc: "CRC correct"
+7206804-7210138 modbus: sc-server-id: "Slave ID: 247"
+7206804-7210138 modbus: cs-server-id: "Slave ID: 247"
+7211380-7214714 modbus: sc-function: "Function 3: Read Holding Registers"
+7211380-7214714 modbus: cs-function: "Function 3: Read Holding Registers"
+7215955-7219289 modbus: sc-length: "Byte count: 30"
+7215955-7223865 modbus: cs-address: "Start at address 0x1E00 / 37681"
+7220531-7228441 modbus: sc-data: "0x0000 / 0"
+7225107-7233016 modbus: cs-length: "Read 0 units of data"
+7229682-7237592 modbus: sc-data: "0x0000 / 0"
+7234258-7242168 modbus: cs-error: "CRC should be 87 116"
+7238834-7246743 modbus: sc-data: "0x41B8 / 16824"
+7243409-7246743 modbus: cs-error: "Unknown function"
+7247985-7251319 modbus: cs-error: "Unknown function"
+7247985-7255894 modbus: sc-data: "0x0194 / 404"
+7252560-7255894 modbus: cs-error: "Unknown function"
+7257136-7260470 modbus: cs-error: "Unknown function"
+7257136-7265046 modbus: sc-data: "0x3E57 / 15959"
+7261712-7265046 modbus: cs-error: "Unknown function"
+7266287-7269621 modbus: cs-error: "Unknown function"
+7266287-7274197 modbus: sc-data: "0x9E9F / 40607"
+7270863-7274197 modbus: cs-error: "Unknown function"
+7275438-7278772 modbus: cs-error: "Unknown function"
+7275438-7283348 modbus: sc-data: "0x4170 / 16752"
+7280014-7283348 modbus: cs-error: "Unknown function"
+7284590-7287924 modbus: cs-error: "Unknown function"
+7284590-7292499 modbus: sc-data: "0x0000 / 0"
+7289165-7292499 modbus: cs-error: "Unknown function"
+7293741-7297075 modbus: cs-error: "Unknown function"
+7293741-7301650 modbus: sc-data: "0x3AC3 / 15043"
+7298316-7301650 modbus: cs-error: "Unknown function"
+7302892-7306226 modbus: cs-error: "Unknown function"
+7302892-7310802 modbus: sc-data: "0x0FB5 / 4021"
+7307468-7310802 modbus: cs-error: "Unknown function"
+7312043-7315377 modbus: cs-error: "Unknown function"
+7312043-7319953 modbus: sc-data: "0x0000 / 0"
+7316619-7319953 modbus: cs-error: "Unknown function"
+7321195-7324529 modbus: cs-error: "Unknown function"
+7321195-7329104 modbus: sc-data: "0x0000 / 0"
+7325770-7329104 modbus: cs-error: "Unknown function"
+7330346-7333680 modbus: cs-error: "Unknown function"
+7330346-7338255 modbus: sc-data: "0x8000 / 32768"
+7334921-7338255 modbus: cs-error: "Unknown function"
+7339497-7342831 modbus: cs-error: "Unknown function"
+7339497-7347407 modbus: sc-data: "0x0008 / 8"
+7344073-7347407 modbus: cs-error: "Unknown function"
+7348648-7351982 modbus: cs-error: "Unknown function"
+7348648-7356558 modbus: sc-data: "0x0000 / 0"
+7353224-7356558 modbus: cs-error: "Unknown function"
+7357799-7361133 modbus: cs-error: "Unknown function"
+7357799-7365709 modbus: sc-crc: "CRC correct"
+7362375-7365709 modbus: cs-error: "Unknown function"
+7521568-7524902 modbus: sc-server-id: "Slave ID: 247"
+7521568-7524902 modbus: cs-server-id: "Slave ID: 247"
+7526238-7529572 modbus: sc-function: "Function 3: Read Holding Registers"
+7526238-7529572 modbus: cs-function: "Function 3: Read Holding Registers"
+7530888-7534222 modbus: sc-length: "Byte count: 0"
+7530888-7538894 modbus: cs-address: "Start at address 0xD / 30014"
+7535560-7543544 modbus: sc-error: "CRC should be 192 194"
+7540210-7548215 modbus: cs-length: "Read 1 units of data"
+7544881-7552865 modbus: sc-error: "Message too long"
+7549531-7557537 modbus: cs-crc: "CRC correct"
+7574387-7577721 modbus: sc-server-id: "Slave ID: 247"
+7574387-7577721 modbus: cs-server-id: "Slave ID: 247"
+7578963-7582297 modbus: sc-function: "Function 3: Read Holding Registers"
+7578963-7582297 modbus: cs-function: "Function 3: Read Holding Registers"
+7583538-7586872 modbus: sc-length: "Byte count: 2"
+7583538-7591448 modbus: cs-address: "Start at address 0x200 / 30513"
+7588114-7596023 modbus: sc-data: "0x0008 / 8"
+7592689-7600599 modbus: cs-length: "Read 2161 units of data"
+7597265-7605175 modbus: sc-crc: "CRC correct"
+7600599-7606426 modbus: cs-error: "Message too short or not finished"
+7769517-7772851 modbus: sc-server-id: "Slave ID: 247"
+7769517-7772851 modbus: cs-server-id: "Slave ID: 247"
+7774187-7777521 modbus: sc-function: "Function 3: Read Holding Registers"
+7774187-7777521 modbus: cs-function: "Function 3: Read Holding Registers"
+7778837-7782171 modbus: sc-length: "Byte count: 64"
+7778837-7786843 modbus: cs-address: "Start at address 0x4082 / 46515"
+7783509-7791493 modbus: sc-data: "0x8200 / 33280"
+7788159-7796164 modbus: cs-length: "Read 2 units of data"
+7792830-7800814 modbus: sc-data: "0x0265 / 613"
+7797480-7805486 modbus: cs-crc: "CRC correct"
+7800814-7806737 modbus: sc-error: "Message too short or not finished"
+7828464-7831798 modbus: sc-server-id: "Slave ID: 247"
+7828464-7831798 modbus: cs-server-id: "Slave ID: 247"
+7833039-7836373 modbus: sc-function: "Function 3: Read Holding Registers"
+7833039-7836373 modbus: cs-function: "Function 3: Read Holding Registers"
+7837615-7840949 modbus: sc-length: "Byte count: 4"
+7837615-7845524 modbus: cs-address: "Start at address 0x400 / 31025"
+7842190-7850100 modbus: sc-data: "0x0000 / 0"
+7846766-7854676 modbus: cs-length: "Read 0 units of data"
+7851342-7859251 modbus: sc-data: "0x0003 / 3"
+7855917-7863827 modbus: cs-error: "CRC should be 80 108"
+7860493-7868402 modbus: sc-crc: "CRC correct"
+7865068-7868402 modbus: cs-error: "Unknown function"
+8033464-8036798 modbus: sc-server-id: "Slave ID: 247"
+8033464-8036798 modbus: cs-server-id: "Slave ID: 247"
+8038135-8041469 modbus: sc-function: "Function 3: Read Holding Registers"
+8038135-8041469 modbus: cs-function: "Function 3: Read Holding Registers"
+8042785-8046119 modbus: sc-length: "Byte count: 0"
+8042785-8050790 modbus: cs-address: "Start at address 0x0 / 30001"
+8047456-8055440 modbus: sc-error: "CRC should be 192 194"
+8052106-8060112 modbus: cs-length: "Read 15 units of data"
+8056778-8064762 modbus: sc-error: "Message too long"
+8061428-8069433 modbus: cs-crc: "CRC correct"
+8086622-8089956 modbus: sc-server-id: "Slave ID: 247"
+8086622-8089956 modbus: cs-server-id: "Slave ID: 247"
+8091197-8094531 modbus: sc-function: "Function 3: Read Holding Registers"
+8091197-8094531 modbus: cs-function: "Function 3: Read Holding Registers"
+8095773-8099107 modbus: sc-length: "Byte count: 30"
+8095773-8103682 modbus: cs-address: "Start at address 0x1E00 / 37681"
+8100348-8108258 modbus: sc-data: "0x0000 / 0"
+8104924-8112834 modbus: cs-length: "Read 0 units of data"
+8109500-8117409 modbus: sc-data: "0x0000 / 0"
+8114075-8121985 modbus: cs-error: "CRC should be 87 116"
+8118651-8126560 modbus: sc-data: "0x41B8 / 16824"
+8123226-8126560 modbus: cs-error: "Unknown function"
+8127802-8131136 modbus: cs-error: "Unknown function"
+8127802-8135712 modbus: sc-data: "0x0194 / 404"
+8132378-8135712 modbus: cs-error: "Unknown function"
+8136953-8140287 modbus: cs-error: "Unknown function"
+8136953-8144863 modbus: sc-data: "0x3E57 / 15959"
+8141529-8144863 modbus: cs-error: "Unknown function"
+8146105-8149439 modbus: cs-error: "Unknown function"
+8146105-8154014 modbus: sc-data: "0x9E9F / 40607"
+8150680-8154014 modbus: cs-error: "Unknown function"
+8155256-8158590 modbus: cs-error: "Unknown function"
+8155256-8163165 modbus: sc-data: "0x4170 / 16752"
+8159831-8163165 modbus: cs-error: "Unknown function"
+8164407-8167741 modbus: cs-error: "Unknown function"
+8164407-8172317 modbus: sc-data: "0x0000 / 0"
+8168983-8172317 modbus: cs-error: "Unknown function"
+8173558-8176892 modbus: cs-error: "Unknown function"
+8173558-8181468 modbus: sc-data: "0x3C5B / 15451"
+8178134-8181468 modbus: cs-error: "Unknown function"
+8182709-8186043 modbus: cs-error: "Unknown function"
+8182709-8190619 modbus: sc-data: "0x71AC / 29100"
+8187285-8190619 modbus: cs-error: "Unknown function"
+8191861-8195195 modbus: cs-error: "Unknown function"
+8191861-8199770 modbus: sc-data: "0x0000 / 0"
+8196436-8199770 modbus: cs-error: "Unknown function"
+8201012-8204346 modbus: cs-error: "Unknown function"
+8201012-8208921 modbus: sc-data: "0x0000 / 0"
+8205587-8208921 modbus: cs-error: "Unknown function"
+8210163-8213497 modbus: cs-error: "Unknown function"
+8210163-8218073 modbus: sc-data: "0x8000 / 32768"
+8214739-8218073 modbus: cs-error: "Unknown function"
+8219314-8222648 modbus: cs-error: "Unknown function"
+8219314-8227224 modbus: sc-data: "0x0008 / 8"
+8223890-8227224 modbus: cs-error: "Unknown function"
+8228466-8231800 modbus: cs-error: "Unknown function"
+8228466-8236375 modbus: sc-data: "0x0000 / 0"
+8233041-8236375 modbus: cs-error: "Unknown function"
+8237617-8240951 modbus: cs-error: "Unknown function"
+8237617-8245526 modbus: sc-crc: "CRC correct"
+8242192-8245526 modbus: cs-error: "Unknown function"
+8396280-8399614 modbus: sc-server-id: "Slave ID: 247"
+8396280-8399614 modbus: cs-server-id: "Slave ID: 247"
+8400950-8404284 modbus: sc-function: "Function 3: Read Holding Registers"
+8400950-8404284 modbus: cs-function: "Function 3: Read Holding Registers"
+8405600-8408934 modbus: sc-length: "Byte count: 0"
+8405600-8413606 modbus: cs-address: "Start at address 0xD / 30014"
+8410272-8418256 modbus: sc-error: "CRC should be 192 194"
+8414922-8422927 modbus: cs-length: "Read 1 units of data"
+8419593-8427577 modbus: sc-error: "Message too long"
+8424243-8432249 modbus: cs-crc: "CRC correct"
+8449109-8452443 modbus: sc-server-id: "Slave ID: 247"
+8449109-8452443 modbus: cs-server-id: "Slave ID: 247"
+8453684-8457018 modbus: sc-function: "Function 3: Read Holding Registers"
+8453684-8457018 modbus: cs-function: "Function 3: Read Holding Registers"
+8458260-8461594 modbus: sc-length: "Byte count: 2"
+8458260-8466170 modbus: cs-address: "Start at address 0x200 / 30513"
+8462836-8470745 modbus: sc-data: "0x0008 / 8"
+8467411-8475321 modbus: cs-length: "Read 2161 units of data"
+8471987-8479896 modbus: sc-crc: "CRC correct"
+8475321-8481147 modbus: cs-error: "Message too short or not finished"
+8644037-8647371 modbus: sc-server-id: "Slave ID: 247"
+8644037-8647371 modbus: cs-server-id: "Slave ID: 247"
+8648707-8652041 modbus: sc-function: "Function 3: Read Holding Registers"
+8648707-8652041 modbus: cs-function: "Function 3: Read Holding Registers"
+8653358-8656692 modbus: sc-length: "Byte count: 64"
+8653358-8661363 modbus: cs-address: "Start at address 0x4082 / 46515"
+8658029-8666013 modbus: sc-data: "0x8200 / 33280"
+8662679-8670685 modbus: cs-length: "Read 2 units of data"
+8667351-8675335 modbus: sc-data: "0x0265 / 613"
+8672001-8680006 modbus: cs-crc: "CRC correct"
+8675335-8681257 modbus: sc-error: "Message too short or not finished"
+8698948-8702282 modbus: sc-server-id: "Slave ID: 247"
+8698948-8702282 modbus: cs-server-id: "Slave ID: 247"
+8703523-8706857 modbus: sc-function: "Function 3: Read Holding Registers"
+8703523-8706857 modbus: cs-function: "Function 3: Read Holding Registers"
+8708099-8711433 modbus: sc-length: "Byte count: 4"
+8708099-8716008 modbus: cs-address: "Start at address 0x400 / 31025"
+8712674-8720584 modbus: sc-data: "0x0000 / 0"
+8717250-8725160 modbus: cs-length: "Read 0 units of data"
+8721826-8729735 modbus: sc-data: "0x0003 / 3"
+8726401-8734311 modbus: cs-error: "CRC should be 80 108"
+8730977-8738886 modbus: sc-crc: "CRC correct"
+8735552-8738886 modbus: cs-error: "Unknown function"
+8905297-8908631 modbus: sc-server-id: "Slave ID: 247"
+8905297-8908631 modbus: cs-server-id: "Slave ID: 247"
+8909967-8913301 modbus: sc-function: "Function 3: Read Holding Registers"
+8909967-8913301 modbus: cs-function: "Function 3: Read Holding Registers"
+8914617-8917951 modbus: sc-length: "Byte count: 0"
+8914617-8922623 modbus: cs-address: "Start at address 0x0 / 30001"
+8919289-8927273 modbus: sc-error: "CRC should be 192 194"
+8923939-8931944 modbus: cs-length: "Read 15 units of data"
+8928610-8936594 modbus: sc-error: "Message too long"
+8933260-8941266 modbus: cs-crc: "CRC correct"
+8958458-8961792 modbus: sc-server-id: "Slave ID: 247"
+8958458-8961792 modbus: cs-server-id: "Slave ID: 247"
+8963033-8966367 modbus: sc-function: "Function 3: Read Holding Registers"
+8963033-8966367 modbus: cs-function: "Function 3: Read Holding Registers"
+8967609-8970943 modbus: sc-length: "Byte count: 30"
+8967609-8975518 modbus: cs-address: "Start at address 0x1E00 / 37681"
+8972184-8980094 modbus: sc-data: "0x0000 / 0"
+8976760-8984670 modbus: cs-length: "Read 0 units of data"
+8981336-8989245 modbus: sc-data: "0x0000 / 0"
+8985911-8993821 modbus: cs-error: "CRC should be 87 116"
+8990487-8998396 modbus: sc-data: "0x41B8 / 16824"
+8995062-8998396 modbus: cs-error: "Unknown function"
+8999638-9002972 modbus: cs-error: "Unknown function"
+8999638-9007548 modbus: sc-data: "0x0194 / 404"
+9004214-9007548 modbus: cs-error: "Unknown function"
+9008789-9012123 modbus: cs-error: "Unknown function"
+9008789-9016699 modbus: sc-data: "0x3E57 / 15959"
+9013365-9016699 modbus: cs-error: "Unknown function"
+9017940-9021274 modbus: cs-error: "Unknown function"
+9017940-9025850 modbus: sc-data: "0x9E9F / 40607"
+9022516-9025850 modbus: cs-error: "Unknown function"
+9027092-9030426 modbus: cs-error: "Unknown function"
+9027092-9035001 modbus: sc-data: "0x4170 / 16752"
+9031667-9035001 modbus: cs-error: "Unknown function"
+9036243-9039577 modbus: cs-error: "Unknown function"
+9036243-9044153 modbus: sc-data: "0x0000 / 0"
+9040819-9044153 modbus: cs-error: "Unknown function"
+9045394-9048728 modbus: cs-error: "Unknown function"
+9045394-9053304 modbus: sc-data: "0x3C5B / 15451"
+9049970-9053304 modbus: cs-error: "Unknown function"
+9054545-9057879 modbus: cs-error: "Unknown function"
+9054545-9062455 modbus: sc-data: "0x71AC / 29100"
+9059121-9062455 modbus: cs-error: "Unknown function"
+9063697-9067031 modbus: cs-error: "Unknown function"
+9063697-9071606 modbus: sc-data: "0x0000 / 0"
+9068272-9071606 modbus: cs-error: "Unknown function"
+9072848-9076182 modbus: cs-error: "Unknown function"
+9072848-9080757 modbus: sc-data: "0x0000 / 0"
+9077423-9080757 modbus: cs-error: "Unknown function"
+9081999-9085333 modbus: cs-error: "Unknown function"
+9081999-9089909 modbus: sc-data: "0x8000 / 32768"
+9086575-9089909 modbus: cs-error: "Unknown function"
+9091150-9094484 modbus: cs-error: "Unknown function"
+9091150-9099060 modbus: sc-data: "0x0008 / 8"
+9095726-9099060 modbus: cs-error: "Unknown function"
+9100301-9103635 modbus: cs-error: "Unknown function"
+9100301-9108211 modbus: sc-data: "0x0000 / 0"
+9104877-9108211 modbus: cs-error: "Unknown function"
+9109453-9112787 modbus: cs-error: "Unknown function"
+9109453-9117362 modbus: sc-crc: "CRC correct"
+9114028-9117362 modbus: cs-error: "Unknown function"
+9271355-9274689 modbus: sc-server-id: "Slave ID: 247"
+9271355-9274689 modbus: cs-server-id: "Slave ID: 247"
+9276025-9279359 modbus: sc-function: "Function 3: Read Holding Registers"
+9276025-9279359 modbus: cs-function: "Function 3: Read Holding Registers"
+9280675-9284009 modbus: sc-length: "Byte count: 0"
+9280675-9288680 modbus: cs-address: "Start at address 0xD / 30014"
+9285346-9293331 modbus: sc-error: "CRC should be 192 194"
+9289997-9298002 modbus: cs-length: "Read 1 units of data"
+9294668-9302652 modbus: sc-error: "Message too long"
+9299318-9307324 modbus: cs-crc: "CRC correct"
+9324195-9327529 modbus: sc-server-id: "Slave ID: 247"
+9324195-9327529 modbus: cs-server-id: "Slave ID: 247"
+9328770-9332104 modbus: sc-function: "Function 3: Read Holding Registers"
+9328770-9332104 modbus: cs-function: "Function 3: Read Holding Registers"
+9333346-9336680 modbus: sc-length: "Byte count: 2"
+9333346-9341255 modbus: cs-address: "Start at address 0x200 / 30513"
+9337921-9345831 modbus: sc-data: "0x0008 / 8"
+9342497-9350407 modbus: cs-length: "Read 2161 units of data"
+9347073-9354982 modbus: sc-crc: "CRC correct"
+9350407-9356233 modbus: cs-error: "Message too short or not finished"
+9519261-9522595 modbus: sc-server-id: "Slave ID: 247"
+9519261-9522595 modbus: cs-server-id: "Slave ID: 247"
+9523932-9527266 modbus: sc-function: "Function 3: Read Holding Registers"
+9523932-9527266 modbus: cs-function: "Function 3: Read Holding Registers"
+9528582-9531916 modbus: sc-length: "Byte count: 64"
+9528582-9536587 modbus: cs-address: "Start at address 0x4082 / 46515"
+9533253-9541237 modbus: sc-data: "0x8200 / 33280"
+9537903-9545909 modbus: cs-length: "Read 2 units of data"
+9542575-9550559 modbus: sc-data: "0x0265 / 613"
+9547225-9555230 modbus: cs-crc: "CRC correct"
+9550559-9556481 modbus: sc-error: "Message too short or not finished"
+9574189-9577523 modbus: sc-server-id: "Slave ID: 247"
+9574189-9577523 modbus: cs-server-id: "Slave ID: 247"
+9578765-9582099 modbus: sc-function: "Function 3: Read Holding Registers"
+9578765-9582099 modbus: cs-function: "Function 3: Read Holding Registers"
+9583340-9586674 modbus: sc-length: "Byte count: 4"
+9583340-9591250 modbus: cs-address: "Start at address 0x400 / 31025"
+9587916-9595826 modbus: sc-data: "0x0000 / 0"
+9592492-9600401 modbus: cs-length: "Read 0 units of data"
+9597067-9604977 modbus: sc-data: "0x0003 / 3"
+9601643-9609552 modbus: cs-error: "CRC should be 80 108"
+9606218-9614128 modbus: sc-crc: "CRC correct"
+9610794-9614128 modbus: cs-error: "Unknown function"
+9778068-9781402 modbus: sc-server-id: "Slave ID: 247"
+9778068-9781402 modbus: cs-server-id: "Slave ID: 247"
+9782738-9786072 modbus: sc-function: "Function 3: Read Holding Registers"
+9782738-9786072 modbus: cs-function: "Function 3: Read Holding Registers"
+9787388-9790722 modbus: sc-length: "Byte count: 0"
+9787388-9795394 modbus: cs-address: "Start at address 0x0 / 30001"
+9792060-9800044 modbus: sc-error: "CRC should be 192 194"
+9796710-9804715 modbus: cs-length: "Read 15 units of data"
+9801381-9809365 modbus: sc-error: "Message too long"
+9806031-9814037 modbus: cs-crc: "CRC correct"
+9831229-9834563 modbus: sc-server-id: "Slave ID: 247"
+9831229-9834563 modbus: cs-server-id: "Slave ID: 247"
+9835805-9839139 modbus: sc-function: "Function 3: Read Holding Registers"
+9835805-9839139 modbus: cs-function: "Function 3: Read Holding Registers"
+9840381-9843715 modbus: sc-length: "Byte count: 30"
+9840381-9848290 modbus: cs-address: "Start at address 0x1E00 / 37681"
+9844956-9852866 modbus: sc-data: "0x0000 / 0"
+9849532-9857441 modbus: cs-length: "Read 0 units of data"
+9854107-9862017 modbus: sc-data: "0x0000 / 0"
+9858683-9866593 modbus: cs-error: "CRC should be 87 116"
+9863259-9871168 modbus: sc-data: "0x41B8 / 16824"
+9867834-9871168 modbus: cs-error: "Unknown function"
+9872410-9875744 modbus: cs-error: "Unknown function"
+9872410-9880320 modbus: sc-data: "0x0678 / 1656"
+9876986-9880320 modbus: cs-error: "Unknown function"
+9881561-9884895 modbus: cs-error: "Unknown function"
+9881561-9889471 modbus: sc-data: "0x3E57 / 15959"
+9886137-9889471 modbus: cs-error: "Unknown function"
+9890712-9894046 modbus: cs-error: "Unknown function"
+9890712-9898622 modbus: sc-data: "0x9E9F / 40607"
+9895288-9898622 modbus: cs-error: "Unknown function"
+9899864-9903198 modbus: cs-error: "Unknown function"
+9899864-9907773 modbus: sc-data: "0x4170 / 16752"
+9904439-9907773 modbus: cs-error: "Unknown function"
+9909015-9912349 modbus: cs-error: "Unknown function"
+9909015-9916924 modbus: sc-data: "0x0000 / 0"
+9913590-9916924 modbus: cs-error: "Unknown function"
+9918166-9921500 modbus: cs-error: "Unknown function"
+9918166-9926076 modbus: sc-data: "0x3C5B / 15451"
+9922742-9926076 modbus: cs-error: "Unknown function"
+9927317-9930651 modbus: cs-error: "Unknown function"
+9927317-9935227 modbus: sc-data: "0x71AC / 29100"
+9931893-9935227 modbus: cs-error: "Unknown function"
+9936469-9939803 modbus: cs-error: "Unknown function"
+9936469-9944378 modbus: sc-data: "0x0000 / 0"
+9941044-9944378 modbus: cs-error: "Unknown function"
+9945620-9948954 modbus: cs-error: "Unknown function"
+9945620-9953529 modbus: sc-data: "0x0000 / 0"
+9950195-9953529 modbus: cs-error: "Unknown function"
+9954771-9958105 modbus: cs-error: "Unknown function"
+9954771-9962681 modbus: sc-data: "0x8000 / 32768"
+9959347-9962681 modbus: cs-error: "Unknown function"
+9963922-9967256 modbus: cs-error: "Unknown function"
+9963922-9971832 modbus: sc-data: "0x0008 / 8"
+9968498-9971832 modbus: cs-error: "Unknown function"
+9973073-9976407 modbus: cs-error: "Unknown function"
+9973073-9980983 modbus: sc-data: "0x0000 / 0"
+9977649-9980983 modbus: cs-error: "Unknown function"
+9982225-9985559 modbus: cs-error: "Unknown function"
+9982225-9990134 modbus: sc-crc: "CRC correct"
+9986800-9990134 modbus: cs-error: "Unknown function"
+10146750-10150084 modbus: sc-server-id: "Slave ID: 247"
+10146750-10150084 modbus: cs-server-id: "Slave ID: 247"
+10151420-10154754 modbus: sc-function: "Function 3: Read Holding Registers"
+10151420-10154754 modbus: cs-function: "Function 3: Read Holding Registers"
+10156070-10159404 modbus: sc-length: "Byte count: 0"
+10156070-10164075 modbus: cs-address: "Start at address 0xD / 30014"
+10160741-10168725 modbus: sc-error: "CRC should be 192 194"
+10165391-10173397 modbus: cs-length: "Read 1 units of data"
+10170063-10178047 modbus: sc-error: "Message too long"
+10174713-10182718 modbus: cs-crc: "CRC correct"
+10199566-10202900 modbus: sc-server-id: "Slave ID: 247"
+10199566-10202900 modbus: cs-server-id: "Slave ID: 247"
+10204142-10207476 modbus: sc-function: "Function 3: Read Holding Registers"
+10204142-10207476 modbus: cs-function: "Function 3: Read Holding Registers"
+10208717-10212051 modbus: sc-length: "Byte count: 2"
+10208717-10216627 modbus: cs-address: "Start at address 0x200 / 30513"
+10213293-10221203 modbus: sc-data: "0x0008 / 8"
+10217869-10225778 modbus: cs-length: "Read 2161 units of data"
+10222444-10230354 modbus: sc-crc: "CRC correct"
+10225778-10231605 modbus: cs-error: "Message too short or not finished"
+10393995-10397329 modbus: sc-server-id: "Slave ID: 247"
+10393995-10397329 modbus: cs-server-id: "Slave ID: 247"
+10398665-10401999 modbus: sc-function: "Function 3: Read Holding Registers"
+10398665-10401999 modbus: cs-function: "Function 3: Read Holding Registers"
+10403315-10406649 modbus: sc-length: "Byte count: 64"
+10403315-10411321 modbus: cs-address: "Start at address 0x4082 / 46515"
+10407987-10415971 modbus: sc-data: "0x8200 / 33280"
+10412637-10420642 modbus: cs-length: "Read 2 units of data"
+10417308-10425292 modbus: sc-data: "0x0265 / 613"
+10421958-10429964 modbus: cs-crc: "CRC correct"
+10425292-10431215 modbus: sc-error: "Message too short or not finished"
+10448911-10452245 modbus: sc-server-id: "Slave ID: 247"
+10448911-10452245 modbus: cs-server-id: "Slave ID: 247"
+10453487-10456821 modbus: sc-function: "Function 3: Read Holding Registers"
+10453487-10456821 modbus: cs-function: "Function 3: Read Holding Registers"
+10458062-10461396 modbus: sc-length: "Byte count: 4"
+10458062-10465972 modbus: cs-address: "Start at address 0x400 / 31025"
+10462638-10470547 modbus: sc-data: "0x0000 / 0"
+10467213-10475123 modbus: cs-length: "Read 0 units of data"
+10471789-10479699 modbus: sc-data: "0x0003 / 3"
+10476365-10484274 modbus: cs-error: "CRC should be 80 108"
+10480940-10488850 modbus: sc-crc: "CRC correct"
+10485516-10488850 modbus: cs-error: "Unknown function"
+10653676-10657010 modbus: sc-server-id: "Slave ID: 247"
+10653676-10657010 modbus: cs-server-id: "Slave ID: 247"
+10658346-10661680 modbus: sc-function: "Function 3: Read Holding Registers"
+10658346-10661680 modbus: cs-function: "Function 3: Read Holding Registers"
+10662996-10666330 modbus: sc-length: "Byte count: 0"
+10662996-10671002 modbus: cs-address: "Start at address 0x0 / 30001"
+10667668-10675652 modbus: sc-error: "CRC should be 192 194"
+10672318-10680324 modbus: cs-length: "Read 15 units of data"
+10676990-10684973 modbus: sc-error: "Message too long"
+10681639-10689645 modbus: cs-crc: "CRC correct"
+10708655-10711989 modbus: sc-server-id: "Slave ID: 247"
+10708655-10711989 modbus: cs-server-id: "Slave ID: 247"
+10713231-10716565 modbus: sc-function: "Function 3: Read Holding Registers"
+10713231-10716565 modbus: cs-function: "Function 3: Read Holding Registers"
+10717806-10721140 modbus: sc-length: "Byte count: 30"
+10717806-10725716 modbus: cs-address: "Start at address 0x1E00 / 37681"
+10722382-10730291 modbus: sc-data: "0x0000 / 0"
+10726957-10734867 modbus: cs-length: "Read 0 units of data"
+10731533-10739443 modbus: sc-data: "0x0000 / 0"
+10736109-10744018 modbus: cs-error: "CRC should be 87 116"
+10740684-10748594 modbus: sc-data: "0x41B8 / 16824"
+10745260-10748594 modbus: cs-error: "Unknown function"
+10749835-10753169 modbus: cs-error: "Unknown function"
+10749835-10757745 modbus: sc-data: "0x0678 / 1656"
+10754411-10757745 modbus: cs-error: "Unknown function"
+10758987-10762321 modbus: cs-error: "Unknown function"
+10758987-10766896 modbus: sc-data: "0x3E57 / 15959"
+10763562-10766896 modbus: cs-error: "Unknown function"
+10768138-10771472 modbus: cs-error: "Unknown function"
+10768138-10776047 modbus: sc-data: "0x9E9F / 40607"
+10772713-10776047 modbus: cs-error: "Unknown function"
+10777289-10780623 modbus: cs-error: "Unknown function"
+10777289-10785199 modbus: sc-data: "0x4170 / 16752"
+10781865-10785199 modbus: cs-error: "Unknown function"
+10786440-10789774 modbus: cs-error: "Unknown function"
+10786440-10794350 modbus: sc-data: "0x0000 / 0"
+10791016-10794350 modbus: cs-error: "Unknown function"
+10795592-10798926 modbus: cs-error: "Unknown function"
+10795592-10803501 modbus: sc-data: "0x3AC3 / 15043"
+10800167-10803501 modbus: cs-error: "Unknown function"
+10804743-10808077 modbus: cs-error: "Unknown function"
+10804743-10812652 modbus: sc-data: "0x0FB5 / 4021"
+10809318-10812652 modbus: cs-error: "Unknown function"
+10813894-10817228 modbus: cs-error: "Unknown function"
+10813894-10821804 modbus: sc-data: "0x0000 / 0"
+10818470-10821804 modbus: cs-error: "Unknown function"
+10823045-10826379 modbus: cs-error: "Unknown function"
+10823045-10830955 modbus: sc-data: "0x0000 / 0"
+10827621-10830955 modbus: cs-error: "Unknown function"
+10832196-10835530 modbus: cs-error: "Unknown function"
+10832196-10840106 modbus: sc-data: "0x8000 / 32768"
+10836772-10840106 modbus: cs-error: "Unknown function"
+10841348-10844682 modbus: cs-error: "Unknown function"
+10841348-10849257 modbus: sc-data: "0x0008 / 8"
+10845923-10849257 modbus: cs-error: "Unknown function"
+10850499-10853833 modbus: cs-error: "Unknown function"
+10850499-10858408 modbus: sc-data: "0x0000 / 0"
+10855074-10858408 modbus: cs-error: "Unknown function"
+10859650-10862984 modbus: cs-error: "Unknown function"
+10859650-10867560 modbus: sc-crc: "CRC correct"
+10864226-10867560 modbus: cs-error: "Unknown function"
+11020907-11024241 modbus: sc-server-id: "Slave ID: 247"
+11020907-11024241 modbus: cs-server-id: "Slave ID: 247"
+11025577-11028911 modbus: sc-function: "Function 3: Read Holding Registers"
+11025577-11028911 modbus: cs-function: "Function 3: Read Holding Registers"
+11030227-11033561 modbus: sc-length: "Byte count: 0"
+11030227-11038233 modbus: cs-address: "Start at address 0xD / 30014"
+11034899-11042883 modbus: sc-error: "CRC should be 192 194"
+11039549-11047554 modbus: cs-length: "Read 1 units of data"
+11044220-11052205 modbus: sc-error: "Message too long"
+11048871-11056876 modbus: cs-crc: "CRC correct"
+11073742-11077076 modbus: sc-server-id: "Slave ID: 247"
+11073742-11077076 modbus: cs-server-id: "Slave ID: 247"
+11078318-11081652 modbus: sc-function: "Function 3: Read Holding Registers"
+11078318-11081652 modbus: cs-function: "Function 3: Read Holding Registers"
+11082893-11086227 modbus: sc-length: "Byte count: 2"
+11082893-11090803 modbus: cs-address: "Start at address 0x200 / 30513"
+11087469-11095378 modbus: sc-data: "0x0008 / 8"
+11092044-11099954 modbus: cs-length: "Read 2161 units of data"
+11096620-11104530 modbus: sc-crc: "CRC correct"
+11099954-11105781 modbus: cs-error: "Message too short or not finished"
+11269390-11272724 modbus: sc-server-id: "Slave ID: 247"
+11269390-11272724 modbus: cs-server-id: "Slave ID: 247"
+11274060-11277394 modbus: sc-function: "Function 3: Read Holding Registers"
+11274060-11277394 modbus: cs-function: "Function 3: Read Holding Registers"
+11278710-11282044 modbus: sc-length: "Byte count: 64"
+11278710-11286715 modbus: cs-address: "Start at address 0x4082 / 46515"
+11283381-11291366 modbus: sc-data: "0x8200 / 33280"
+11288032-11296037 modbus: cs-length: "Read 2 units of data"
+11292703-11300687 modbus: sc-data: "0x0265 / 613"
+11297353-11305359 modbus: cs-crc: "CRC correct"
+11300687-11306610 modbus: sc-error: "Message too short or not finished"
+11324309-11327643 modbus: sc-server-id: "Slave ID: 247"
+11324309-11327643 modbus: cs-server-id: "Slave ID: 247"
+11328884-11332218 modbus: sc-function: "Function 3: Read Holding Registers"
+11328884-11332218 modbus: cs-function: "Function 3: Read Holding Registers"
+11333460-11336794 modbus: sc-length: "Byte count: 4"
+11333460-11341369 modbus: cs-address: "Start at address 0x400 / 31025"
+11338035-11345945 modbus: sc-data: "0x0000 / 0"
+11342611-11350521 modbus: cs-length: "Read 0 units of data"
+11347187-11355096 modbus: sc-data: "0x0003 / 3"
+11351762-11359672 modbus: cs-error: "CRC should be 80 108"
+11356338-11364247 modbus: sc-crc: "CRC correct"
+11360913-11364247 modbus: cs-error: "Unknown function"
+11529092-11532426 modbus: sc-server-id: "Slave ID: 247"
+11529092-11532426 modbus: cs-server-id: "Slave ID: 247"
+11533763-11537097 modbus: sc-function: "Function 3: Read Holding Registers"
+11533763-11537097 modbus: cs-function: "Function 3: Read Holding Registers"
+11538413-11541747 modbus: sc-length: "Byte count: 0"
+11538413-11546418 modbus: cs-address: "Start at address 0x0 / 30001"
+11543084-11551068 modbus: sc-error: "CRC should be 192 194"
+11547734-11555740 modbus: cs-length: "Read 15 units of data"
+11552406-11560390 modbus: sc-error: "Message too long"
+11557056-11565061 modbus: cs-crc: "CRC correct"
+11582259-11585593 modbus: sc-server-id: "Slave ID: 247"
+11582259-11585593 modbus: cs-server-id: "Slave ID: 247"
+11586834-11590168 modbus: sc-function: "Function 3: Read Holding Registers"
+11586834-11590168 modbus: cs-function: "Function 3: Read Holding Registers"
+11591410-11594744 modbus: sc-length: "Byte count: 30"
+11591410-11599320 modbus: cs-address: "Start at address 0x1E00 / 37681"
+11595986-11603895 modbus: sc-data: "0x0000 / 0"
+11600561-11608471 modbus: cs-length: "Read 0 units of data"
+11605137-11613046 modbus: sc-data: "0x0000 / 0"
+11609712-11617622 modbus: cs-error: "CRC should be 87 116"
+11614288-11622198 modbus: sc-data: "0x41B8 / 16824"
+11618864-11622198 modbus: cs-error: "Unknown function"
+11623439-11626773 modbus: cs-error: "Unknown function"
+11623439-11631349 modbus: sc-data: "0x0678 / 1656"
+11628015-11631349 modbus: cs-error: "Unknown function"
+11632590-11635924 modbus: cs-error: "Unknown function"
+11632590-11640500 modbus: sc-data: "0x3E57 / 15959"
+11637166-11640500 modbus: cs-error: "Unknown function"
+11641742-11645076 modbus: cs-error: "Unknown function"
+11641742-11649651 modbus: sc-data: "0x9E9F / 40607"
+11646317-11649651 modbus: cs-error: "Unknown function"
+11650893-11654227 modbus: cs-error: "Unknown function"
+11650893-11658803 modbus: sc-data: "0x4170 / 16752"
+11655469-11658803 modbus: cs-error: "Unknown function"
+11660044-11663378 modbus: cs-error: "Unknown function"
+11660044-11667954 modbus: sc-data: "0x0000 / 0"
+11664620-11667954 modbus: cs-error: "Unknown function"
+11669195-11672529 modbus: cs-error: "Unknown function"
+11669195-11677105 modbus: sc-data: "0x3AC3 / 15043"
+11673771-11677105 modbus: cs-error: "Unknown function"
+11678347-11681681 modbus: cs-error: "Unknown function"
+11678347-11686256 modbus: sc-data: "0x0FB5 / 4021"
+11682922-11686256 modbus: cs-error: "Unknown function"
+11687498-11690832 modbus: cs-error: "Unknown function"
+11687498-11695407 modbus: sc-data: "0x0000 / 0"
+11692073-11695407 modbus: cs-error: "Unknown function"
+11696649-11699983 modbus: cs-error: "Unknown function"
+11696649-11704559 modbus: sc-data: "0x0000 / 0"
+11701225-11704559 modbus: cs-error: "Unknown function"
+11705800-11709134 modbus: cs-error: "Unknown function"
+11705800-11713710 modbus: sc-data: "0x8000 / 32768"
+11710376-11713710 modbus: cs-error: "Unknown function"
+11714951-11718285 modbus: cs-error: "Unknown function"
+11714951-11722861 modbus: sc-data: "0x0008 / 8"
+11719527-11722861 modbus: cs-error: "Unknown function"
+11724103-11727437 modbus: cs-error: "Unknown function"
+11724103-11732012 modbus: sc-data: "0x0000 / 0"
+11728678-11732012 modbus: cs-error: "Unknown function"
+11733254-11736588 modbus: cs-error: "Unknown function"
+11733254-11741164 modbus: sc-crc: "CRC correct"
+11737830-11741164 modbus: cs-error: "Unknown function"
+11895875-11899209 modbus: sc-server-id: "Slave ID: 247"
+11895875-11899209 modbus: cs-server-id: "Slave ID: 247"
+11900546-11903880 modbus: sc-function: "Function 3: Read Holding Registers"
+11900546-11903880 modbus: cs-function: "Function 3: Read Holding Registers"
+11905196-11908530 modbus: sc-length: "Byte count: 0"
+11905196-11913201 modbus: cs-address: "Start at address 0xD / 30014"
+11909867-11917851 modbus: sc-error: "CRC should be 192 194"
+11914517-11922523 modbus: cs-length: "Read 1 units of data"
+11919189-11927173 modbus: sc-error: "Message too long"
+11923839-11931844 modbus: cs-crc: "CRC correct"
+11948698-11952032 modbus: sc-server-id: "Slave ID: 247"
+11948698-11952032 modbus: cs-server-id: "Slave ID: 247"
+11953273-11956607 modbus: sc-function: "Function 3: Read Holding Registers"
+11953273-11956607 modbus: cs-function: "Function 3: Read Holding Registers"
+11957849-11961183 modbus: sc-length: "Byte count: 2"
+11957849-11965758 modbus: cs-address: "Start at address 0x200 / 30513"
+11962424-11970334 modbus: sc-data: "0x0008 / 8"
+11967000-11974910 modbus: cs-length: "Read 2161 units of data"
+11971576-11979485 modbus: sc-crc: "CRC correct"
+11974910-11980736 modbus: cs-error: "Message too short or not finished"
+12143483-12146817 modbus: sc-server-id: "Slave ID: 247"
+12143483-12146817 modbus: cs-server-id: "Slave ID: 247"
+12148154-12151488 modbus: sc-function: "Function 3: Read Holding Registers"
+12148154-12151488 modbus: cs-function: "Function 3: Read Holding Registers"
+12152804-12156138 modbus: sc-length: "Byte count: 64"
+12152804-12160809 modbus: cs-address: "Start at address 0x4082 / 46515"
+12157475-12165459 modbus: sc-data: "0x8200 / 33280"
+12162125-12170131 modbus: cs-length: "Read 2 units of data"
+12166797-12174781 modbus: sc-data: "0x0265 / 613"
+12171447-12179452 modbus: cs-crc: "CRC correct"
+12174781-12180703 modbus: sc-error: "Message too short or not finished"
+12198407-12201741 modbus: sc-server-id: "Slave ID: 247"
+12198407-12201741 modbus: cs-server-id: "Slave ID: 247"
+12202982-12206316 modbus: sc-function: "Function 3: Read Holding Registers"
+12202982-12206316 modbus: cs-function: "Function 3: Read Holding Registers"
+12207558-12210892 modbus: sc-length: "Byte count: 4"
+12207558-12215467 modbus: cs-address: "Start at address 0x400 / 31025"
+12212133-12220043 modbus: sc-data: "0x0000 / 0"
+12216709-12224618 modbus: cs-length: "Read 0 units of data"
+12221284-12229194 modbus: sc-data: "0x0003 / 3"
+12225860-12233770 modbus: cs-error: "CRC should be 80 108"
+12230436-12238345 modbus: sc-crc: "CRC correct"
+12235011-12238345 modbus: cs-error: "Unknown function"
+12406812-12410146 modbus: sc-server-id: "Slave ID: 247"
+12406812-12410146 modbus: cs-server-id: "Slave ID: 247"
+12411482-12414816 modbus: sc-function: "Function 3: Read Holding Registers"
+12411482-12414816 modbus: cs-function: "Function 3: Read Holding Registers"
+12416132-12419466 modbus: sc-length: "Byte count: 0"
+12416132-12424138 modbus: cs-address: "Start at address 0x0 / 30001"
+12420804-12428788 modbus: sc-error: "CRC should be 192 194"
+12425454-12433459 modbus: cs-length: "Read 15 units of data"
+12430125-12438110 modbus: sc-error: "Message too long"
+12434776-12442781 modbus: cs-crc: "CRC correct"
+12459970-12463304 modbus: sc-server-id: "Slave ID: 247"
+12459970-12463304 modbus: cs-server-id: "Slave ID: 247"
+12464546-12467880 modbus: sc-function: "Function 3: Read Holding Registers"
+12464546-12467880 modbus: cs-function: "Function 3: Read Holding Registers"
+12469121-12472455 modbus: sc-length: "Byte count: 30"
+12469121-12477031 modbus: cs-address: "Start at address 0x1E00 / 37681"
+12473697-12481607 modbus: sc-data: "0x0000 / 0"
+12478273-12486182 modbus: cs-length: "Read 0 units of data"
+12482848-12490758 modbus: sc-data: "0x0000 / 0"
+12487424-12495333 modbus: cs-error: "CRC should be 87 116"
+12491999-12499909 modbus: sc-data: "0x41B8 / 16824"
+12496575-12499909 modbus: cs-error: "Unknown function"
+12501151-12504485 modbus: cs-error: "Unknown function"
+12501151-12509060 modbus: sc-data: "0x0678 / 1656"
+12505726-12509060 modbus: cs-error: "Unknown function"
+12510302-12513636 modbus: cs-error: "Unknown function"
+12510302-12518212 modbus: sc-data: "0x3E57 / 15959"
+12514878-12518212 modbus: cs-error: "Unknown function"
+12519453-12522787 modbus: cs-error: "Unknown function"
+12519453-12527363 modbus: sc-data: "0x9E9F / 40607"
+12524029-12527363 modbus: cs-error: "Unknown function"
+12528604-12531938 modbus: cs-error: "Unknown function"
+12528604-12536514 modbus: sc-data: "0x4170 / 16752"
+12533180-12536514 modbus: cs-error: "Unknown function"
+12537756-12541090 modbus: cs-error: "Unknown function"
+12537756-12545665 modbus: sc-data: "0x0000 / 0"
+12542331-12545665 modbus: cs-error: "Unknown function"
+12546907-12550241 modbus: cs-error: "Unknown function"
+12546907-12554816 modbus: sc-data: "0x3AC3 / 15043"
+12551482-12554816 modbus: cs-error: "Unknown function"
+12556058-12559392 modbus: cs-error: "Unknown function"
+12556058-12563968 modbus: sc-data: "0x0FB5 / 4021"
+12560634-12563968 modbus: cs-error: "Unknown function"
+12565209-12568543 modbus: cs-error: "Unknown function"
+12565209-12573119 modbus: sc-data: "0x0000 / 0"
+12569785-12573119 modbus: cs-error: "Unknown function"
+12574360-12577694 modbus: cs-error: "Unknown function"
+12574360-12582270 modbus: sc-data: "0x0000 / 0"
+12578936-12582270 modbus: cs-error: "Unknown function"
+12583512-12586846 modbus: cs-error: "Unknown function"
+12583512-12591421 modbus: sc-data: "0x8000 / 32768"
+12588087-12591421 modbus: cs-error: "Unknown function"
+12592663-12595997 modbus: cs-error: "Unknown function"
+12592663-12600573 modbus: sc-data: "0x0008 / 8"
+12597239-12600573 modbus: cs-error: "Unknown function"
+12601814-12605148 modbus: cs-error: "Unknown function"
+12601814-12609724 modbus: sc-data: "0x0000 / 0"
+12606390-12609724 modbus: cs-error: "Unknown function"
+12610965-12614299 modbus: cs-error: "Unknown function"
+12610965-12618875 modbus: sc-crc: "CRC correct"
+12615541-12618875 modbus: cs-error: "Unknown function"
+12771142-12774476 modbus: sc-server-id: "Slave ID: 247"
+12771142-12774476 modbus: cs-server-id: "Slave ID: 247"
+12775812-12779146 modbus: sc-function: "Function 3: Read Holding Registers"
+12775812-12779146 modbus: cs-function: "Function 3: Read Holding Registers"
+12780462-12783796 modbus: sc-length: "Byte count: 0"
+12780462-12788468 modbus: cs-address: "Start at address 0xD / 30014"
+12785134-12793118 modbus: sc-error: "CRC should be 192 194"
+12789784-12797789 modbus: cs-length: "Read 1 units of data"
+12794455-12802440 modbus: sc-error: "Message too long"
+12799106-12807111 modbus: cs-crc: "CRC correct"
+12823965-12827299 modbus: sc-server-id: "Slave ID: 247"
+12823965-12827299 modbus: cs-server-id: "Slave ID: 247"
+12828541-12831875 modbus: sc-function: "Function 3: Read Holding Registers"
+12828541-12831875 modbus: cs-function: "Function 3: Read Holding Registers"
+12833116-12836450 modbus: sc-length: "Byte count: 2"
+12833116-12841026 modbus: cs-address: "Start at address 0x200 / 30513"
+12837692-12845602 modbus: sc-data: "0x0008 / 8"
+12842268-12850177 modbus: cs-length: "Read 2161 units of data"
+12846843-12854753 modbus: sc-crc: "CRC correct"
+12850177-12856004 modbus: cs-error: "Message too short or not finished"
+13018665-13021999 modbus: sc-server-id: "Slave ID: 247"
+13018665-13021999 modbus: cs-server-id: "Slave ID: 247"
+13023335-13026669 modbus: sc-function: "Function 3: Read Holding Registers"
+13023335-13026669 modbus: cs-function: "Function 3: Read Holding Registers"
+13027985-13031319 modbus: sc-length: "Byte count: 64"
+13027985-13035991 modbus: cs-address: "Start at address 0x4082 / 46515"
+13032657-13040641 modbus: sc-data: "0x8200 / 33280"
+13037307-13045312 modbus: cs-length: "Read 2 units of data"
+13041978-13049962 modbus: sc-data: "0x0265 / 613"
+13046628-13054634 modbus: cs-crc: "CRC correct"
+13049962-13055885 modbus: sc-error: "Message too short or not finished"
+13073570-13076904 modbus: sc-server-id: "Slave ID: 247"
+13073570-13076904 modbus: cs-server-id: "Slave ID: 247"
+13078146-13081480 modbus: sc-function: "Function 3: Read Holding Registers"
+13078146-13081480 modbus: cs-function: "Function 3: Read Holding Registers"
+13082721-13086055 modbus: sc-length: "Byte count: 4"
+13082721-13090631 modbus: cs-address: "Start at address 0x400 / 31025"
+13087297-13095207 modbus: sc-data: "0x0000 / 0"
+13091873-13099782 modbus: cs-length: "Read 0 units of data"
+13096448-13104358 modbus: sc-data: "0x0003 / 3"
+13101024-13108933 modbus: cs-error: "CRC should be 80 108"
+13105599-13113509 modbus: sc-crc: "CRC correct"
+13110175-13113509 modbus: cs-error: "Unknown function"
+13285513-13288847 modbus: sc-server-id: "Slave ID: 247"
+13285513-13288847 modbus: cs-server-id: "Slave ID: 247"
+13290183-13293517 modbus: sc-function: "Function 3: Read Holding Registers"
+13290183-13293517 modbus: cs-function: "Function 3: Read Holding Registers"
+13294833-13298167 modbus: sc-length: "Byte count: 0"
+13294833-13302839 modbus: cs-address: "Start at address 0x0 / 30001"
+13299505-13307489 modbus: sc-error: "CRC should be 192 194"
+13304155-13312161 modbus: cs-length: "Read 15 units of data"
+13308827-13316811 modbus: sc-error: "Message too long"
+13313477-13321482 modbus: cs-crc: "CRC correct"
+13338670-13342004 modbus: sc-server-id: "Slave ID: 247"
+13338670-13342004 modbus: cs-server-id: "Slave ID: 247"
+13343245-13346579 modbus: sc-function: "Function 3: Read Holding Registers"
+13343245-13346579 modbus: cs-function: "Function 3: Read Holding Registers"
+13347821-13351155 modbus: sc-length: "Byte count: 30"
+13347821-13355730 modbus: cs-address: "Start at address 0x1E00 / 37681"
+13352396-13360306 modbus: sc-data: "0x0000 / 0"
+13356972-13364882 modbus: cs-length: "Read 0 units of data"
+13361548-13369457 modbus: sc-data: "0x0000 / 0"
+13366123-13374033 modbus: cs-error: "CRC should be 87 116"
+13370699-13378608 modbus: sc-data: "0x41B8 / 16824"
+13375274-13378608 modbus: cs-error: "Unknown function"
+13379850-13383184 modbus: cs-error: "Unknown function"
+13379850-13387760 modbus: sc-data: "0x0678 / 1656"
+13384426-13387760 modbus: cs-error: "Unknown function"
+13389001-13392335 modbus: cs-error: "Unknown function"
+13389001-13396911 modbus: sc-data: "0x3E57 / 15959"
+13393577-13396911 modbus: cs-error: "Unknown function"
+13398153-13401487 modbus: cs-error: "Unknown function"
+13398153-13406062 modbus: sc-data: "0x9E9F / 40607"
+13402728-13406062 modbus: cs-error: "Unknown function"
+13407304-13410638 modbus: cs-error: "Unknown function"
+13407304-13415213 modbus: sc-data: "0x4170 / 16752"
+13411879-13415213 modbus: cs-error: "Unknown function"
+13416455-13419789 modbus: cs-error: "Unknown function"
+13416455-13424365 modbus: sc-data: "0x0000 / 0"
+13421031-13424365 modbus: cs-error: "Unknown function"
+13425606-13428940 modbus: cs-error: "Unknown function"
+13425606-13433516 modbus: sc-data: "0x3AC3 / 15043"
+13430182-13433516 modbus: cs-error: "Unknown function"
+13434757-13438091 modbus: cs-error: "Unknown function"
+13434757-13442667 modbus: sc-data: "0x0FB5 / 4021"
+13439333-13442667 modbus: cs-error: "Unknown function"
+13443909-13447243 modbus: cs-error: "Unknown function"
+13443909-13451818 modbus: sc-data: "0x0000 / 0"
+13448484-13451818 modbus: cs-error: "Unknown function"
+13453060-13456394 modbus: cs-error: "Unknown function"
+13453060-13460969 modbus: sc-data: "0x0000 / 0"
+13457635-13460969 modbus: cs-error: "Unknown function"
+13462211-13465545 modbus: cs-error: "Unknown function"
+13462211-13470121 modbus: sc-data: "0x8000 / 32768"
+13466787-13470121 modbus: cs-error: "Unknown function"
+13471362-13474696 modbus: cs-error: "Unknown function"
+13471362-13479272 modbus: sc-data: "0x0008 / 8"
+13475938-13479272 modbus: cs-error: "Unknown function"
+13480514-13483848 modbus: cs-error: "Unknown function"
+13480514-13488423 modbus: sc-data: "0x0000 / 0"
+13485089-13488423 modbus: cs-error: "Unknown function"
+13489665-13492999 modbus: cs-error: "Unknown function"
+13489665-13497574 modbus: sc-crc: "CRC correct"
+13494240-13497574 modbus: cs-error: "Unknown function"
+13646132-13649466 modbus: sc-server-id: "Slave ID: 247"
+13646132-13649466 modbus: cs-server-id: "Slave ID: 247"
+13650802-13654136 modbus: sc-function: "Function 3: Read Holding Registers"
+13650802-13654136 modbus: cs-function: "Function 3: Read Holding Registers"
+13655452-13658786 modbus: sc-length: "Byte count: 0"
+13655452-13663457 modbus: cs-address: "Start at address 0xD / 30014"
+13660123-13668108 modbus: sc-error: "CRC should be 192 194"
+13664774-13672779 modbus: cs-length: "Read 1 units of data"
+13669445-13677429 modbus: sc-error: "Message too long"
+13674095-13682101 modbus: cs-crc: "CRC correct"
+13698973-13702307 modbus: sc-server-id: "Slave ID: 247"
+13698973-13702307 modbus: cs-server-id: "Slave ID: 247"
+13703549-13706883 modbus: sc-function: "Function 3: Read Holding Registers"
+13703549-13706883 modbus: cs-function: "Function 3: Read Holding Registers"
+13708124-13711458 modbus: sc-length: "Byte count: 2"
+13708124-13716034 modbus: cs-address: "Start at address 0x200 / 30513"
+13712700-13720609 modbus: sc-data: "0x0008 / 8"
+13717275-13725185 modbus: cs-length: "Read 2161 units of data"
+13721851-13729761 modbus: sc-crc: "CRC correct"
+13725185-13731012 modbus: cs-error: "Message too short or not finished"
+13893526-13896860 modbus: sc-server-id: "Slave ID: 247"
+13893526-13896860 modbus: cs-server-id: "Slave ID: 247"
+13898197-13901531 modbus: sc-function: "Function 3: Read Holding Registers"
+13898197-13901531 modbus: cs-function: "Function 3: Read Holding Registers"
+13902847-13906181 modbus: sc-length: "Byte count: 64"
+13902847-13910852 modbus: cs-address: "Start at address 0x4082 / 46515"
+13907518-13915502 modbus: sc-data: "0x8200 / 33280"
+13912168-13920174 modbus: cs-length: "Read 2 units of data"
+13916840-13924824 modbus: sc-data: "0x0265 / 613"
+13921490-13929495 modbus: cs-crc: "CRC correct"
+13924824-13930746 modbus: sc-error: "Message too short or not finished"
+13948447-13951781 modbus: sc-server-id: "Slave ID: 247"
+13948447-13951781 modbus: cs-server-id: "Slave ID: 247"
+13953023-13956357 modbus: sc-function: "Function 3: Read Holding Registers"
+13953023-13956357 modbus: cs-function: "Function 3: Read Holding Registers"
+13957599-13960933 modbus: sc-length: "Byte count: 4"
+13957599-13965509 modbus: cs-address: "Start at address 0x400 / 31025"
+13962175-13970084 modbus: sc-data: "0x0000 / 0"
+13966750-13974660 modbus: cs-length: "Read 0 units of data"
+13971326-13979235 modbus: sc-data: "0x0003 / 3"
+13975901-13983811 modbus: cs-error: "CRC should be 80 108"
+13980477-13988387 modbus: sc-crc: "CRC correct"
+13985053-13988387 modbus: cs-error: "Unknown function"
+14152760-14156094 modbus: sc-server-id: "Slave ID: 247"
+14152760-14156094 modbus: cs-server-id: "Slave ID: 247"
+14157430-14160764 modbus: sc-function: "Function 3: Read Holding Registers"
+14157430-14160764 modbus: cs-function: "Function 3: Read Holding Registers"
+14162080-14165414 modbus: sc-length: "Byte count: 0"
+14162080-14170085 modbus: cs-address: "Start at address 0x0 / 30001"
+14166751-14174735 modbus: sc-error: "CRC should be 192 194"
+14171401-14179407 modbus: cs-length: "Read 15 units of data"
+14176073-14184057 modbus: sc-error: "Message too long"
+14180723-14188728 modbus: cs-crc: "CRC correct"
+14205929-14209263 modbus: sc-server-id: "Slave ID: 247"
+14205929-14209263 modbus: cs-server-id: "Slave ID: 247"
+14210506-14213840 modbus: sc-function: "Function 3: Read Holding Registers"
+14210506-14213840 modbus: cs-function: "Function 3: Read Holding Registers"
+14215081-14218415 modbus: sc-length: "Byte count: 30"
+14215081-14222991 modbus: cs-address: "Start at address 0x1E00 / 37681"
+14219657-14227566 modbus: sc-data: "0x0000 / 0"
+14224232-14232142 modbus: cs-length: "Read 0 units of data"
+14228808-14236718 modbus: sc-data: "0x0000 / 0"
+14233384-14241293 modbus: cs-error: "CRC should be 87 116"
+14237959-14245869 modbus: sc-data: "0x41B8 / 16824"
+14242535-14245869 modbus: cs-error: "Unknown function"
+14247110-14250444 modbus: cs-error: "Unknown function"
+14247110-14255020 modbus: sc-data: "0x0678 / 1656"
+14251686-14255020 modbus: cs-error: "Unknown function"
+14256262-14259596 modbus: cs-error: "Unknown function"
+14256262-14264171 modbus: sc-data: "0x3E57 / 15959"
+14260837-14264171 modbus: cs-error: "Unknown function"
+14265413-14268747 modbus: cs-error: "Unknown function"
+14265413-14273323 modbus: sc-data: "0x9E9F / 40607"
+14269989-14273323 modbus: cs-error: "Unknown function"
+14274564-14277898 modbus: cs-error: "Unknown function"
+14274564-14282474 modbus: sc-data: "0x4170 / 16752"
+14279140-14282474 modbus: cs-error: "Unknown function"
+14283715-14287049 modbus: cs-error: "Unknown function"
+14283715-14291625 modbus: sc-data: "0x0000 / 0"
+14288291-14291625 modbus: cs-error: "Unknown function"
+14292867-14296201 modbus: cs-error: "Unknown function"
+14292867-14300776 modbus: sc-data: "0x3AC3 / 15043"
+14297442-14300776 modbus: cs-error: "Unknown function"
+14302018-14305352 modbus: cs-error: "Unknown function"
+14302018-14309927 modbus: sc-data: "0x0FB5 / 4021"
+14306593-14309927 modbus: cs-error: "Unknown function"
+14311169-14314503 modbus: cs-error: "Unknown function"
+14311169-14319079 modbus: sc-data: "0x0000 / 0"
+14315745-14319079 modbus: cs-error: "Unknown function"
+14320320-14323654 modbus: cs-error: "Unknown function"
+14320320-14328230 modbus: sc-data: "0x0000 / 0"
+14324896-14328230 modbus: cs-error: "Unknown function"
+14329471-14332805 modbus: cs-error: "Unknown function"
+14329471-14337381 modbus: sc-data: "0x8000 / 32768"
+14334047-14337381 modbus: cs-error: "Unknown function"
+14338623-14341957 modbus: cs-error: "Unknown function"
+14338623-14346532 modbus: sc-data: "0x0008 / 8"
+14343198-14346532 modbus: cs-error: "Unknown function"
+14347774-14351108 modbus: cs-error: "Unknown function"
+14347774-14355683 modbus: sc-data: "0x0000 / 0"
+14352349-14355683 modbus: cs-error: "Unknown function"
+14356925-14360259 modbus: cs-error: "Unknown function"
+14356925-14364835 modbus: sc-crc: "CRC correct"
+14361501-14364835 modbus: cs-error: "Unknown function"
+14521164-14524498 modbus: sc-server-id: "Slave ID: 247"
+14521164-14524498 modbus: cs-server-id: "Slave ID: 247"
+14525834-14529168 modbus: sc-function: "Function 3: Read Holding Registers"
+14525834-14529168 modbus: cs-function: "Function 3: Read Holding Registers"
+14530484-14533818 modbus: sc-length: "Byte count: 0"
+14530484-14538490 modbus: cs-address: "Start at address 0xD / 30014"
+14535156-14543140 modbus: sc-error: "CRC should be 192 194"
+14539806-14547811 modbus: cs-length: "Read 1 units of data"
+14544477-14552461 modbus: sc-error: "Message too long"
+14549127-14557133 modbus: cs-crc: "CRC correct"
+14573981-14577315 modbus: sc-server-id: "Slave ID: 247"
+14573981-14577315 modbus: cs-server-id: "Slave ID: 247"
+14578556-14581890 modbus: sc-function: "Function 3: Read Holding Registers"
+14578556-14581890 modbus: cs-function: "Function 3: Read Holding Registers"
+14583132-14586466 modbus: sc-length: "Byte count: 2"
+14583132-14591041 modbus: cs-address: "Start at address 0x200 / 30513"
+14587707-14595617 modbus: sc-data: "0x0008 / 8"
+14592283-14600193 modbus: cs-length: "Read 2161 units of data"
+14596859-14604768 modbus: sc-crc: "CRC correct"
+14600193-14606019 modbus: cs-error: "Message too short or not finished"
+14769198-14772532 modbus: sc-server-id: "Slave ID: 247"
+14769198-14772532 modbus: cs-server-id: "Slave ID: 247"
+14773869-14777203 modbus: sc-function: "Function 3: Read Holding Registers"
+14773869-14777203 modbus: cs-function: "Function 3: Read Holding Registers"
+14778519-14781853 modbus: sc-length: "Byte count: 64"
+14778519-14786524 modbus: cs-address: "Start at address 0x4082 / 46515"
+14783190-14791174 modbus: sc-data: "0x8200 / 33280"
+14787840-14795846 modbus: cs-length: "Read 2 units of data"
+14792512-14800496 modbus: sc-data: "0x0265 / 613"
+14797162-14805167 modbus: cs-crc: "CRC correct"
+14800496-14806418 modbus: sc-error: "Message too short or not finished"
+14824106-14827440 modbus: sc-server-id: "Slave ID: 247"
+14824106-14827440 modbus: cs-server-id: "Slave ID: 247"
+14828681-14832015 modbus: sc-function: "Function 3: Read Holding Registers"
+14828681-14832015 modbus: cs-function: "Function 3: Read Holding Registers"
+14833257-14836591 modbus: sc-length: "Byte count: 4"
+14833257-14841166 modbus: cs-address: "Start at address 0x400 / 31025"
+14837832-14845742 modbus: sc-data: "0x0000 / 0"
+14842408-14850317 modbus: cs-length: "Read 0 units of data"
+14846983-14854893 modbus: sc-data: "0x0003 / 3"
+14851559-14859469 modbus: cs-error: "CRC should be 80 108"
+14856135-14864044 modbus: sc-crc: "CRC correct"
+14860710-14864044 modbus: cs-error: "Unknown function"
+15026981-15030315 modbus: sc-server-id: "Slave ID: 247"
+15026981-15030315 modbus: cs-server-id: "Slave ID: 247"
+15031651-15034985 modbus: sc-function: "Function 3: Read Holding Registers"
+15031651-15034985 modbus: cs-function: "Function 3: Read Holding Registers"
+15036302-15039636 modbus: sc-length: "Byte count: 0"
+15036302-15044307 modbus: cs-address: "Start at address 0x0 / 30001"
+15040973-15048957 modbus: sc-error: "CRC should be 192 194"
+15045623-15053628 modbus: cs-length: "Read 15 units of data"
+15050294-15058278 modbus: sc-error: "Message too long"
+15054944-15062950 modbus: cs-crc: "CRC correct"
+15080158-15083492 modbus: sc-server-id: "Slave ID: 247"
+15080158-15083492 modbus: cs-server-id: "Slave ID: 247"
+15084733-15088067 modbus: sc-function: "Function 3: Read Holding Registers"
+15084733-15088067 modbus: cs-function: "Function 3: Read Holding Registers"
+15089309-15092643 modbus: sc-length: "Byte count: 30"
+15089309-15097219 modbus: cs-address: "Start at address 0x1E00 / 37681"
+15093885-15101794 modbus: sc-data: "0x0000 / 0"
+15098460-15106370 modbus: cs-length: "Read 0 units of data"
+15103036-15110945 modbus: sc-data: "0x0000 / 0"
+15107611-15115521 modbus: cs-error: "CRC should be 87 116"
+15112187-15120097 modbus: sc-data: "0x41B8 / 16824"
+15116763-15120097 modbus: cs-error: "Unknown function"
+15121338-15124672 modbus: cs-error: "Unknown function"
+15121338-15129248 modbus: sc-data: "0x0678 / 1656"
+15125914-15129248 modbus: cs-error: "Unknown function"
+15130489-15133823 modbus: cs-error: "Unknown function"
+15130489-15138399 modbus: sc-data: "0x3E57 / 15959"
+15135065-15138399 modbus: cs-error: "Unknown function"
+15139641-15142975 modbus: cs-error: "Unknown function"
+15139641-15147550 modbus: sc-data: "0x9E9F / 40607"
+15144216-15147550 modbus: cs-error: "Unknown function"
+15148792-15152126 modbus: cs-error: "Unknown function"
+15148792-15156701 modbus: sc-data: "0x4170 / 16752"
+15153367-15156701 modbus: cs-error: "Unknown function"
+15157943-15161277 modbus: cs-error: "Unknown function"
+15157943-15165853 modbus: sc-data: "0x0000 / 0"
+15162519-15165853 modbus: cs-error: "Unknown function"
+15167094-15170428 modbus: cs-error: "Unknown function"
+15167094-15175004 modbus: sc-data: "0x3AC3 / 15043"
+15171670-15175004 modbus: cs-error: "Unknown function"
+15176246-15179580 modbus: cs-error: "Unknown function"
+15176246-15184155 modbus: sc-data: "0x0FB5 / 4021"
+15180821-15184155 modbus: cs-error: "Unknown function"
+15185397-15188731 modbus: cs-error: "Unknown function"
+15185397-15193306 modbus: sc-data: "0x0000 / 0"
+15189972-15193306 modbus: cs-error: "Unknown function"
+15194548-15197882 modbus: cs-error: "Unknown function"
+15194548-15202458 modbus: sc-data: "0x0000 / 0"
+15199124-15202458 modbus: cs-error: "Unknown function"
+15203699-15207033 modbus: cs-error: "Unknown function"
+15203699-15211609 modbus: sc-data: "0x8000 / 32768"
+15208275-15211609 modbus: cs-error: "Unknown function"
+15212850-15216184 modbus: cs-error: "Unknown function"
+15212850-15220760 modbus: sc-data: "0x0008 / 8"
+15217426-15220760 modbus: cs-error: "Unknown function"
+15222002-15225336 modbus: cs-error: "Unknown function"
+15222002-15229911 modbus: sc-data: "0x0000 / 0"
+15226577-15229911 modbus: cs-error: "Unknown function"
+15231153-15234487 modbus: cs-error: "Unknown function"
+15231153-15239062 modbus: sc-crc: "CRC correct"
+15235728-15239062 modbus: cs-error: "Unknown function"
+15396153-15399487 modbus: sc-server-id: "Slave ID: 247"
+15396153-15399487 modbus: cs-server-id: "Slave ID: 247"
+15400824-15404158 modbus: sc-function: "Function 3: Read Holding Registers"
+15400824-15404158 modbus: cs-function: "Function 3: Read Holding Registers"
+15405474-15408808 modbus: sc-length: "Byte count: 0"
+15405474-15413479 modbus: cs-address: "Start at address 0xD / 30014"
+15410145-15418129 modbus: sc-error: "CRC should be 192 194"
+15414795-15422801 modbus: cs-length: "Read 1 units of data"
+15419467-15427451 modbus: sc-error: "Message too long"
+15424117-15432122 modbus: cs-crc: "CRC correct"
+15448988-15452322 modbus: sc-server-id: "Slave ID: 247"
+15448988-15452322 modbus: cs-server-id: "Slave ID: 247"
+15453564-15456898 modbus: sc-function: "Function 3: Read Holding Registers"
+15453564-15456898 modbus: cs-function: "Function 3: Read Holding Registers"
+15458140-15461474 modbus: sc-length: "Byte count: 2"
+15458140-15466049 modbus: cs-address: "Start at address 0x200 / 30513"
+15462715-15470625 modbus: sc-data: "0x0008 / 8"
+15467291-15475200 modbus: cs-length: "Read 2161 units of data"
+15471866-15479776 modbus: sc-crc: "CRC correct"
+15475200-15481027 modbus: cs-error: "Message too short or not finished"
+15644017-15647351 modbus: sc-server-id: "Slave ID: 247"
+15644017-15647351 modbus: cs-server-id: "Slave ID: 247"
+15648688-15652022 modbus: sc-function: "Function 3: Read Holding Registers"
+15648688-15652022 modbus: cs-function: "Function 3: Read Holding Registers"
+15653338-15656672 modbus: sc-length: "Byte count: 64"
+15653338-15661343 modbus: cs-address: "Start at address 0x4082 / 46515"
+15658009-15665993 modbus: sc-data: "0x8200 / 33280"
+15662659-15670665 modbus: cs-length: "Read 2 units of data"
+15667331-15675315 modbus: sc-data: "0x0265 / 613"
+15671981-15679986 modbus: cs-crc: "CRC correct"
+15675315-15681237 modbus: sc-error: "Message too short or not finished"
+15698931-15702265 modbus: sc-server-id: "Slave ID: 247"
+15698931-15702265 modbus: cs-server-id: "Slave ID: 247"
+15703507-15706841 modbus: sc-function: "Function 3: Read Holding Registers"
+15703507-15706841 modbus: cs-function: "Function 3: Read Holding Registers"
+15708082-15711416 modbus: sc-length: "Byte count: 4"
+15708082-15715992 modbus: cs-address: "Start at address 0x400 / 31025"
+15712658-15720568 modbus: sc-data: "0x0000 / 0"
+15717234-15725143 modbus: cs-length: "Read 0 units of data"
+15721809-15729719 modbus: sc-data: "0x0003 / 3"
+15726385-15734294 modbus: cs-error: "CRC should be 80 108"
+15730960-15738870 modbus: sc-crc: "CRC correct"
+15735536-15738870 modbus: cs-error: "Unknown function"
+15903336-15906670 modbus: sc-server-id: "Slave ID: 247"
+15903336-15906670 modbus: cs-server-id: "Slave ID: 247"
+15908006-15911340 modbus: sc-function: "Function 3: Read Holding Registers"
+15908006-15911340 modbus: cs-function: "Function 3: Read Holding Registers"
+15912656-15915990 modbus: sc-length: "Byte count: 0"
+15912656-15920662 modbus: cs-address: "Start at address 0x0 / 30001"
+15917328-15925312 modbus: sc-error: "CRC should be 192 194"
+15921978-15929983 modbus: cs-length: "Read 15 units of data"
+15926649-15934633 modbus: sc-error: "Message too long"
+15931299-15939305 modbus: cs-crc: "CRC correct"
+15956491-15959825 modbus: sc-server-id: "Slave ID: 247"
+15956491-15959825 modbus: cs-server-id: "Slave ID: 247"
+15961067-15964401 modbus: sc-function: "Function 3: Read Holding Registers"
+15961067-15964401 modbus: cs-function: "Function 3: Read Holding Registers"
+15965642-15968976 modbus: sc-length: "Byte count: 30"
+15965642-15973552 modbus: cs-address: "Start at address 0x1E00 / 37681"
+15970218-15978128 modbus: sc-data: "0x0000 / 0"
+15974794-15982703 modbus: cs-length: "Read 0 units of data"
+15979369-15987279 modbus: sc-data: "0x0000 / 0"
+15983945-15991855 modbus: cs-error: "CRC should be 87 116"
+15988521-15996430 modbus: sc-data: "0x41B8 / 16824"
+15993096-15996430 modbus: cs-error: "Unknown function"
+15997672-16001006 modbus: cs-error: "Unknown function"
+15997672-16005581 modbus: sc-data: "0x0678 / 1656"
+16002247-16005581 modbus: cs-error: "Unknown function"
+16006823-16010157 modbus: cs-error: "Unknown function"
+16006823-16014733 modbus: sc-data: "0x3E57 / 15959"
+16011399-16014733 modbus: cs-error: "Unknown function"
+16015974-16019308 modbus: cs-error: "Unknown function"
+16015974-16023884 modbus: sc-data: "0x9E9F / 40607"
+16020550-16023884 modbus: cs-error: "Unknown function"
+16025125-16028459 modbus: cs-error: "Unknown function"
+16025125-16033035 modbus: sc-data: "0x4170 / 16752"
+16029701-16033035 modbus: cs-error: "Unknown function"
+16034277-16037611 modbus: cs-error: "Unknown function"
+16034277-16042186 modbus: sc-data: "0x0000 / 0"
+16038852-16042186 modbus: cs-error: "Unknown function"
+16043428-16046762 modbus: cs-error: "Unknown function"
+16043428-16051337 modbus: sc-data: "0x3AC3 / 15043"
+16048003-16051337 modbus: cs-error: "Unknown function"
+16052579-16055913 modbus: cs-error: "Unknown function"
+16052579-16060489 modbus: sc-data: "0x0FB5 / 4021"
+16057155-16060489 modbus: cs-error: "Unknown function"
+16061730-16065064 modbus: cs-error: "Unknown function"
+16061730-16069640 modbus: sc-data: "0x0000 / 0"
+16066306-16069640 modbus: cs-error: "Unknown function"
+16070882-16074216 modbus: cs-error: "Unknown function"
+16070882-16078791 modbus: sc-data: "0x0000 / 0"
+16075457-16078791 modbus: cs-error: "Unknown function"
+16080033-16083367 modbus: cs-error: "Unknown function"
+16080033-16087942 modbus: sc-data: "0x8000 / 32768"
+16084608-16087942 modbus: cs-error: "Unknown function"
+16089184-16092518 modbus: cs-error: "Unknown function"
+16089184-16097094 modbus: sc-data: "0x0008 / 8"
+16093760-16097094 modbus: cs-error: "Unknown function"
+16098335-16101669 modbus: cs-error: "Unknown function"
+16098335-16106245 modbus: sc-data: "0x0000 / 0"
+16102911-16106245 modbus: cs-error: "Unknown function"
+16107486-16110820 modbus: cs-error: "Unknown function"
+16107486-16115396 modbus: sc-crc: "CRC correct"
+16112062-16115396 modbus: cs-error: "Unknown function"
+16271228-16274562 modbus: sc-server-id: "Slave ID: 247"
+16271228-16274562 modbus: cs-server-id: "Slave ID: 247"
+16275898-16279232 modbus: sc-function: "Function 3: Read Holding Registers"
+16275898-16279232 modbus: cs-function: "Function 3: Read Holding Registers"
+16280549-16283883 modbus: sc-length: "Byte count: 0"
+16280549-16288554 modbus: cs-address: "Start at address 0xD / 30014"
+16285220-16293204 modbus: sc-error: "CRC should be 192 194"
+16289870-16297875 modbus: cs-length: "Read 1 units of data"
+16294541-16302526 modbus: sc-error: "Message too long"
+16299192-16307197 modbus: cs-crc: "CRC correct"
+16324048-16327382 modbus: sc-server-id: "Slave ID: 247"
+16324048-16327382 modbus: cs-server-id: "Slave ID: 247"
+16328624-16331958 modbus: sc-function: "Function 3: Read Holding Registers"
+16328624-16331958 modbus: cs-function: "Function 3: Read Holding Registers"
+16333199-16336533 modbus: sc-length: "Byte count: 2"
+16333199-16341109 modbus: cs-address: "Start at address 0x200 / 30513"
+16337775-16345684 modbus: sc-data: "0x0008 / 8"
+16342350-16350260 modbus: cs-length: "Read 2161 units of data"
+16346926-16354836 modbus: sc-crc: "CRC correct"
+16350260-16356087 modbus: cs-error: "Message too short or not finished"
+16518708-16522042 modbus: sc-server-id: "Slave ID: 247"
+16518708-16522042 modbus: cs-server-id: "Slave ID: 247"
+16523378-16526712 modbus: sc-function: "Function 3: Read Holding Registers"
+16523378-16526712 modbus: cs-function: "Function 3: Read Holding Registers"
+16528029-16531363 modbus: sc-length: "Byte count: 64"
+16528029-16536034 modbus: cs-address: "Start at address 0x4082 / 46515"
+16532700-16540684 modbus: sc-data: "0x8200 / 33280"
+16537350-16545356 modbus: cs-length: "Read 2 units of data"
+16542022-16550006 modbus: sc-data: "0x0265 / 613"
+16546672-16554677 modbus: cs-crc: "CRC correct"
+16550006-16555928 modbus: sc-error: "Message too short or not finished"
+16573627-16576961 modbus: sc-server-id: "Slave ID: 247"
+16573627-16576961 modbus: cs-server-id: "Slave ID: 247"
+16578203-16581537 modbus: sc-function: "Function 3: Read Holding Registers"
+16578203-16581537 modbus: cs-function: "Function 3: Read Holding Registers"
+16582778-16586112 modbus: sc-length: "Byte count: 4"
+16582778-16590688 modbus: cs-address: "Start at address 0x400 / 31025"
+16587354-16595263 modbus: sc-data: "0x0000 / 0"
+16591929-16599839 modbus: cs-length: "Read 0 units of data"
+16596505-16604415 modbus: sc-data: "0x0003 / 3"
+16601081-16608990 modbus: cs-error: "CRC should be 80 108"
+16605656-16613566 modbus: sc-crc: "CRC correct"
+16610232-16613566 modbus: cs-error: "Unknown function"
+16783018-16786352 modbus: sc-server-id: "Slave ID: 247"
+16783018-16786352 modbus: cs-server-id: "Slave ID: 247"
+16787688-16791022 modbus: sc-function: "Function 16: Write Multiple Registers"
+16787688-16791022 modbus: cs-function: "Function 16: Write Multiple Registers"
+16792338-16800344 modbus: sc-address: "Start at address 0x6 / 30007"
+16792338-16800344 modbus: cs-address: "Start at address 0x6 / 30007"
+16801660-16809665 modbus: sc-data: "Write 2 Registers"
+16801660-16809665 modbus: cs-length: "Write 2 Registers"
+16810982-16814316 modbus: cs-length: "Byte count: 4"
+16810982-16818987 modbus: sc-error: "CRC should be 181 95"
+16815653-16818987 modbus: cs-data: "Value 0x41"
+16820303-16823637 modbus: sc-error: "Message too long"
+16820303-16823637 modbus: cs-data: "Value 0x70"
+16824975-16828309 modbus: sc-error: "Message too long"
+16824975-16828309 modbus: cs-data: "Value 0x0"
+16829625-16832959 modbus: sc-error: "Message too long"
+16829625-16832959 modbus: cs-data: "Value 0x0"
+16834296-16837630 modbus: sc-error: "Message too long"
+16838946-16842280 modbus: sc-error: "Message too long"
+16834296-16842280 modbus: cs-crc: "CRC correct"
+16859212-16862546 modbus: sc-server-id: "Slave ID: 247"
+16859212-16862546 modbus: cs-server-id: "Slave ID: 247"
+16863788-16867122 modbus: sc-function: "Function 16: Write Multiple Registers"
+16863788-16867122 modbus: cs-function: "Function 16: Write Multiple Registers"
+16868364-16876273 modbus: sc-address: "Start at address 0x6 / 30007"
+16868364-16876273 modbus: cs-address: "Start at address 0x6 / 30007"
+16877515-16885425 modbus: sc-data: "Write 2 Registers"
+16877515-16885425 modbus: cs-length: "Write 2 Registers"
+16886666-16890000 modbus: cs-error: "Bad byte count, is 181, should be 4"
+16886666-16894576 modbus: sc-crc: "CRC correct"
+16891242-16894576 modbus: cs-data: "Value 0x5F"
+17519656-17522990 modbus: sc-server-id: "Slave ID: 247"
+17519656-17522990 modbus: cs-server-id: "Slave ID: 247"
+17524305-17527639 modbus: sc-function: "Function 3: Read Holding Registers"
+17524305-17527639 modbus: cs-function: "Function 3: Read Holding Registers"
+17528976-17532310 modbus: sc-length: "Byte count: 0"
+17528976-17536961 modbus: cs-address: "Start at address 0x0 / 30001"
+17533627-17541632 modbus: sc-error: "CRC should be 192 194"
+17538298-17546282 modbus: cs-length: "Read 15 units of data"
+17542948-17550953 modbus: sc-error: "Message too long"
+17547619-17555604 modbus: cs-crc: "CRC correct"
+17572799-17576133 modbus: sc-server-id: "Slave ID: 247"
+17572799-17576133 modbus: cs-server-id: "Slave ID: 247"
+17577376-17580710 modbus: sc-function: "Function 3: Read Holding Registers"
+17577376-17580710 modbus: cs-function: "Function 3: Read Holding Registers"
+17581951-17585285 modbus: sc-length: "Byte count: 30"
+17581951-17589861 modbus: cs-address: "Start at address 0x1E00 / 37681"
+17586527-17594436 modbus: sc-data: "0x0000 / 0"
+17591102-17599012 modbus: cs-length: "Read 0 units of data"
+17595678-17603588 modbus: sc-data: "0x0000 / 0"
+17600254-17608163 modbus: cs-error: "CRC should be 87 116"
+17604829-17612739 modbus: sc-data: "0x41B8 / 16824"
+17609405-17612739 modbus: cs-error: "Unknown function"
+17613981-17617315 modbus: cs-error: "Unknown function"
+17613981-17621890 modbus: sc-data: "0x0678 / 1656"
+17618556-17621890 modbus: cs-error: "Unknown function"
+17623132-17626466 modbus: cs-error: "Unknown function"
+17623132-17631041 modbus: sc-data: "0x3E57 / 15959"
+17627707-17631041 modbus: cs-error: "Unknown function"
+17632283-17635617 modbus: cs-error: "Unknown function"
+17632283-17640193 modbus: sc-data: "0x9E9F / 40607"
+17636859-17640193 modbus: cs-error: "Unknown function"
+17641434-17644768 modbus: cs-error: "Unknown function"
+17641434-17649344 modbus: sc-data: "0x4170 / 16752"
+17646010-17649344 modbus: cs-error: "Unknown function"
+17650585-17653919 modbus: cs-error: "Unknown function"
+17650585-17658495 modbus: sc-data: "0x0000 / 0"
+17655161-17658495 modbus: cs-error: "Unknown function"
+17659737-17663071 modbus: cs-error: "Unknown function"
+17659737-17667646 modbus: sc-data: "0x3C5B / 15451"
+17664312-17667646 modbus: cs-error: "Unknown function"
+17668888-17672222 modbus: cs-error: "Unknown function"
+17668888-17676797 modbus: sc-data: "0x71AC / 29100"
+17673463-17676797 modbus: cs-error: "Unknown function"
+17678039-17681373 modbus: cs-error: "Unknown function"
+17678039-17685949 modbus: sc-data: "0x0000 / 0"
+17682615-17685949 modbus: cs-error: "Unknown function"
+17687190-17690524 modbus: cs-error: "Unknown function"
+17687190-17695100 modbus: sc-data: "0x0000 / 0"
+17691766-17695100 modbus: cs-error: "Unknown function"
+17696341-17699675 modbus: cs-error: "Unknown function"
+17696341-17704251 modbus: sc-data: "0x8000 / 32768"
+17700917-17704251 modbus: cs-error: "Unknown function"
+17705493-17708827 modbus: cs-error: "Unknown function"
+17705493-17713402 modbus: sc-data: "0x0008 / 8"
+17710068-17713402 modbus: cs-error: "Unknown function"
+17714644-17717978 modbus: cs-error: "Unknown function"
+17714644-17722554 modbus: sc-data: "0x0000 / 0"
+17719220-17722554 modbus: cs-error: "Unknown function"
+17723795-17727129 modbus: cs-error: "Unknown function"
+17723795-17731705 modbus: sc-crc: "CRC correct"
+17728371-17731705 modbus: cs-error: "Unknown function"
+17895590-17898924 modbus: sc-server-id: "Slave ID: 247"
+17895590-17898924 modbus: cs-server-id: "Slave ID: 247"
+17900239-17903573 modbus: sc-function: "Function 3: Read Holding Registers"
+17900239-17903573 modbus: cs-function: "Function 3: Read Holding Registers"
+17904910-17908244 modbus: sc-length: "Byte count: 0"
+17904910-17912895 modbus: cs-address: "Start at address 0xD / 30014"
+17909561-17917566 modbus: sc-error: "CRC should be 192 194"
+17914232-17922216 modbus: cs-length: "Read 1 units of data"
+17918882-17926888 modbus: sc-error: "Message too long"
+17923554-17931538 modbus: cs-crc: "CRC correct"
+17948390-17951724 modbus: sc-server-id: "Slave ID: 247"
+17948390-17951724 modbus: cs-server-id: "Slave ID: 247"
+17952966-17956300 modbus: sc-function: "Function 3: Read Holding Registers"
+17952966-17956300 modbus: cs-function: "Function 3: Read Holding Registers"
+17957541-17960875 modbus: sc-length: "Byte count: 2"
+17957541-17965451 modbus: cs-address: "Start at address 0x200 / 30513"
+17962117-17970027 modbus: sc-data: "0x0008 / 8"
+17966693-17974602 modbus: cs-length: "Read 2161 units of data"
+17971268-17979178 modbus: sc-crc: "CRC correct"
+17974602-17980429 modbus: cs-error: "Message too short or not finished"
+18143838-18147172 modbus: sc-server-id: "Slave ID: 247"
+18143838-18147172 modbus: cs-server-id: "Slave ID: 247"
+18148487-18151821 modbus: sc-function: "Function 3: Read Holding Registers"
+18148487-18151821 modbus: cs-function: "Function 3: Read Holding Registers"
+18153158-18156492 modbus: sc-length: "Byte count: 64"
+18153158-18161142 modbus: cs-address: "Start at address 0x4082 / 46515"
+18157808-18165814 modbus: sc-data: "0x8200 / 33280"
+18162480-18170464 modbus: cs-length: "Read 2 units of data"
+18167130-18175135 modbus: sc-data: "0x0265 / 613"
+18171801-18179786 modbus: cs-crc: "CRC correct"
+18175135-18181037 modbus: sc-error: "Message too short or not finished"
+18198723-18202057 modbus: sc-server-id: "Slave ID: 247"
+18198723-18202057 modbus: cs-server-id: "Slave ID: 247"
+18203299-18206633 modbus: sc-function: "Function 3: Read Holding Registers"
+18203299-18206633 modbus: cs-function: "Function 3: Read Holding Registers"
+18207874-18211208 modbus: sc-length: "Byte count: 4"
+18207874-18215784 modbus: cs-address: "Start at address 0x400 / 31025"
+18212450-18220359 modbus: sc-data: "0x0000 / 0"
+18217025-18224935 modbus: cs-length: "Read 0 units of data"
+18221601-18229511 modbus: sc-data: "0x0003 / 3"
+18226177-18234086 modbus: cs-error: "CRC should be 80 108"
+18230752-18238662 modbus: sc-crc: "CRC correct"
+18235328-18238662 modbus: cs-error: "Unknown function"
+18404116-18407450 modbus: sc-server-id: "Slave ID: 247"
+18404116-18407450 modbus: cs-server-id: "Slave ID: 247"
+18408765-18412099 modbus: sc-function: "Function 3: Read Holding Registers"
+18408765-18412099 modbus: cs-function: "Function 3: Read Holding Registers"
+18413437-18416771 modbus: sc-length: "Byte count: 0"
+18413437-18421421 modbus: cs-address: "Start at address 0x0 / 30001"
+18418087-18426092 modbus: sc-error: "CRC should be 192 194"
+18422758-18430743 modbus: cs-length: "Read 15 units of data"
+18427409-18435414 modbus: sc-error: "Message too long"
+18432080-18440064 modbus: cs-crc: "CRC correct"
+18457271-18460605 modbus: sc-server-id: "Slave ID: 247"
+18457271-18460605 modbus: cs-server-id: "Slave ID: 247"
+18461847-18465181 modbus: sc-function: "Function 3: Read Holding Registers"
+18461847-18465181 modbus: cs-function: "Function 3: Read Holding Registers"
+18466422-18469756 modbus: sc-length: "Byte count: 30"
+18466422-18474332 modbus: cs-address: "Start at address 0x1E00 / 37681"
+18470998-18478907 modbus: sc-data: "0x0000 / 0"
+18475573-18483483 modbus: cs-length: "Read 0 units of data"
+18480149-18488059 modbus: sc-data: "0x0000 / 0"
+18484725-18492634 modbus: cs-error: "CRC should be 87 116"
+18489300-18497210 modbus: sc-data: "0x41B8 / 16824"
+18493876-18497210 modbus: cs-error: "Unknown function"
+18498451-18501785 modbus: cs-error: "Unknown function"
+18498451-18506361 modbus: sc-data: "0x0678 / 1656"
+18503027-18506361 modbus: cs-error: "Unknown function"
+18507603-18510937 modbus: cs-error: "Unknown function"
+18507603-18515512 modbus: sc-data: "0x3E57 / 15959"
+18512178-18515512 modbus: cs-error: "Unknown function"
+18516754-18520088 modbus: cs-error: "Unknown function"
+18516754-18524663 modbus: sc-data: "0x9E9F / 40607"
+18521329-18524663 modbus: cs-error: "Unknown function"
+18525905-18529239 modbus: cs-error: "Unknown function"
+18525905-18533815 modbus: sc-data: "0x4170 / 16752"
+18530481-18533815 modbus: cs-error: "Unknown function"
+18535056-18538390 modbus: cs-error: "Unknown function"
+18535056-18542966 modbus: sc-data: "0x0000 / 0"
+18539632-18542966 modbus: cs-error: "Unknown function"
+18544208-18547542 modbus: cs-error: "Unknown function"
+18544208-18552117 modbus: sc-data: "0x0000 / 0"
+18548783-18552117 modbus: cs-error: "Unknown function"
+18553359-18556693 modbus: cs-error: "Unknown function"
+18553359-18561268 modbus: sc-data: "0x0000 / 0"
+18557934-18561268 modbus: cs-error: "Unknown function"
+18562510-18565844 modbus: cs-error: "Unknown function"
+18562510-18570420 modbus: sc-data: "0x0000 / 0"
+18567086-18570420 modbus: cs-error: "Unknown function"
+18571661-18574995 modbus: cs-error: "Unknown function"
+18571661-18579571 modbus: sc-data: "0x0000 / 0"
+18576237-18579571 modbus: cs-error: "Unknown function"
+18580812-18584146 modbus: cs-error: "Unknown function"
+18580812-18588722 modbus: sc-data: "0x8000 / 32768"
+18585388-18588722 modbus: cs-error: "Unknown function"
+18589964-18593298 modbus: cs-error: "Unknown function"
+18589964-18597873 modbus: sc-data: "0x0008 / 8"
+18594539-18597873 modbus: cs-error: "Unknown function"
+18599115-18602449 modbus: cs-error: "Unknown function"
+18599115-18607024 modbus: sc-data: "0x0000 / 0"
+18603690-18607024 modbus: cs-error: "Unknown function"
+18608266-18611600 modbus: cs-error: "Unknown function"
+18608266-18616176 modbus: sc-crc: "CRC correct"
+18612842-18616176 modbus: cs-error: "Unknown function"
+18770814-18774148 modbus: sc-server-id: "Slave ID: 247"
+18770814-18774148 modbus: cs-server-id: "Slave ID: 247"
+18775463-18778797 modbus: sc-function: "Function 3: Read Holding Registers"
+18775463-18778797 modbus: cs-function: "Function 3: Read Holding Registers"
+18780135-18783469 modbus: sc-length: "Byte count: 0"
+18780135-18788119 modbus: cs-address: "Start at address 0xD / 30014"
+18784785-18792790 modbus: sc-error: "CRC should be 192 194"
+18789456-18797440 modbus: cs-length: "Read 1 units of data"
+18794106-18802112 modbus: sc-error: "Message too long"
+18798778-18806762 modbus: cs-crc: "CRC correct"
+18823632-18826966 modbus: sc-server-id: "Slave ID: 247"
+18823632-18826966 modbus: cs-server-id: "Slave ID: 247"
+18828207-18831541 modbus: sc-function: "Function 3: Read Holding Registers"
+18828207-18831541 modbus: cs-function: "Function 3: Read Holding Registers"
+18832783-18836117 modbus: sc-length: "Byte count: 2"
+18832783-18840693 modbus: cs-address: "Start at address 0x200 / 30513"
+18837359-18845268 modbus: sc-data: "0x0008 / 8"
+18841934-18849844 modbus: cs-length: "Read 2161 units of data"
+18846510-18854419 modbus: sc-crc: "CRC correct"
+18849844-18855670 modbus: cs-error: "Message too short or not finished"
+19018379-19021713 modbus: sc-server-id: "Slave ID: 247"
+19018379-19021713 modbus: cs-server-id: "Slave ID: 247"
+19023028-19026362 modbus: sc-function: "Function 3: Read Holding Registers"
+19023028-19026362 modbus: cs-function: "Function 3: Read Holding Registers"
+19027700-19031034 modbus: sc-length: "Byte count: 64"
+19027700-19035684 modbus: cs-address: "Start at address 0x4082 / 46515"
+19032350-19040355 modbus: sc-data: "0x8200 / 33280"
+19037021-19045006 modbus: cs-length: "Read 2 units of data"
+19041672-19049677 modbus: sc-data: "0x0265 / 613"
+19046343-19054327 modbus: cs-crc: "CRC correct"
+19049677-19055578 modbus: sc-error: "Message too short or not finished"
+19073262-19076596 modbus: sc-server-id: "Slave ID: 247"
+19073262-19076596 modbus: cs-server-id: "Slave ID: 247"
+19077838-19081172 modbus: sc-function: "Function 3: Read Holding Registers"
+19077838-19081172 modbus: cs-function: "Function 3: Read Holding Registers"
+19082414-19085748 modbus: sc-length: "Byte count: 4"
+19082414-19090323 modbus: cs-address: "Start at address 0x400 / 31025"
+19086989-19094899 modbus: sc-data: "0x0000 / 0"
+19091565-19099475 modbus: cs-length: "Read 0 units of data"
+19096141-19104050 modbus: sc-data: "0x0003 / 3"
+19100716-19108626 modbus: cs-error: "CRC should be 80 108"
+19105292-19113201 modbus: sc-crc: "CRC correct"
+19109867-19113201 modbus: cs-error: "Unknown function"
+19279596-19282930 modbus: sc-server-id: "Slave ID: 247"
+19279596-19282930 modbus: cs-server-id: "Slave ID: 247"
+19284245-19287579 modbus: sc-function: "Function 3: Read Holding Registers"
+19284245-19287579 modbus: cs-function: "Function 3: Read Holding Registers"
+19288917-19292251 modbus: sc-length: "Byte count: 0"
+19288917-19296901 modbus: cs-address: "Start at address 0x0 / 30001"
+19293567-19301572 modbus: sc-error: "CRC should be 192 194"
+19298238-19306223 modbus: cs-length: "Read 15 units of data"
+19302889-19310894 modbus: sc-error: "Message too long"
+19307560-19315544 modbus: cs-crc: "CRC correct"
+19332746-19336080 modbus: sc-server-id: "Slave ID: 247"
+19332746-19336080 modbus: cs-server-id: "Slave ID: 247"
+19337322-19340656 modbus: sc-function: "Function 3: Read Holding Registers"
+19337322-19340656 modbus: cs-function: "Function 3: Read Holding Registers"
+19341898-19345232 modbus: sc-length: "Byte count: 30"
+19341898-19349807 modbus: cs-address: "Start at address 0x1E00 / 37681"
+19346473-19354383 modbus: sc-data: "0x0000 / 0"
+19351049-19358959 modbus: cs-length: "Read 0 units of data"
+19355625-19363534 modbus: sc-data: "0x0000 / 0"
+19360200-19368110 modbus: cs-error: "CRC should be 87 116"
+19364776-19372685 modbus: sc-data: "0x41B8 / 16824"
+19369351-19372685 modbus: cs-error: "Unknown function"
+19373927-19377261 modbus: cs-error: "Unknown function"
+19373927-19381837 modbus: sc-data: "0x0678 / 1656"
+19378503-19381837 modbus: cs-error: "Unknown function"
+19383078-19386412 modbus: cs-error: "Unknown function"
+19383078-19390988 modbus: sc-data: "0x3E57 / 15959"
+19387654-19390988 modbus: cs-error: "Unknown function"
+19392229-19395563 modbus: cs-error: "Unknown function"
+19392229-19400139 modbus: sc-data: "0x9E9F / 40607"
+19396805-19400139 modbus: cs-error: "Unknown function"
+19401381-19404715 modbus: cs-error: "Unknown function"
+19401381-19409290 modbus: sc-data: "0x4170 / 16752"
+19405956-19409290 modbus: cs-error: "Unknown function"
+19410532-19413866 modbus: cs-error: "Unknown function"
+19410532-19418442 modbus: sc-data: "0x0000 / 0"
+19415108-19418442 modbus: cs-error: "Unknown function"
+19419683-19423017 modbus: cs-error: "Unknown function"
+19419683-19427593 modbus: sc-data: "0x3AC3 / 15043"
+19424259-19427593 modbus: cs-error: "Unknown function"
+19428834-19432168 modbus: cs-error: "Unknown function"
+19428834-19436744 modbus: sc-data: "0x0FB5 / 4021"
+19433410-19436744 modbus: cs-error: "Unknown function"
+19437986-19441320 modbus: cs-error: "Unknown function"
+19437986-19445895 modbus: sc-data: "0x0000 / 0"
+19442561-19445895 modbus: cs-error: "Unknown function"
+19447137-19450471 modbus: cs-error: "Unknown function"
+19447137-19455046 modbus: sc-data: "0x0000 / 0"
+19451712-19455046 modbus: cs-error: "Unknown function"
+19456288-19459622 modbus: cs-error: "Unknown function"
+19456288-19464198 modbus: sc-data: "0x8000 / 32768"
+19460864-19464198 modbus: cs-error: "Unknown function"
+19465439-19468773 modbus: cs-error: "Unknown function"
+19465439-19473349 modbus: sc-data: "0x0008 / 8"
+19470015-19473349 modbus: cs-error: "Unknown function"
+19474591-19477925 modbus: cs-error: "Unknown function"
+19474591-19482500 modbus: sc-data: "0x0000 / 0"
+19479166-19482500 modbus: cs-error: "Unknown function"
+19483742-19487076 modbus: cs-error: "Unknown function"
+19483742-19491651 modbus: sc-crc: "CRC correct"
+19488317-19491651 modbus: cs-error: "Unknown function"
+19645228-19648562 modbus: sc-server-id: "Slave ID: 247"
+19645228-19648562 modbus: cs-server-id: "Slave ID: 247"
+19649877-19653211 modbus: sc-function: "Function 3: Read Holding Registers"
+19649877-19653211 modbus: cs-function: "Function 3: Read Holding Registers"
+19654548-19657882 modbus: sc-length: "Byte count: 0"
+19654548-19662532 modbus: cs-address: "Start at address 0xD / 30014"
+19659198-19667204 modbus: sc-error: "CRC should be 192 194"
+19663870-19671854 modbus: cs-length: "Read 1 units of data"
+19668520-19676525 modbus: sc-error: "Message too long"
+19673191-19681175 modbus: cs-crc: "CRC correct"
+19698042-19701376 modbus: sc-server-id: "Slave ID: 247"
+19698042-19701376 modbus: cs-server-id: "Slave ID: 247"
+19702617-19705951 modbus: sc-function: "Function 3: Read Holding Registers"
+19702617-19705951 modbus: cs-function: "Function 3: Read Holding Registers"
+19707193-19710527 modbus: sc-length: "Byte count: 2"
+19707193-19715102 modbus: cs-address: "Start at address 0x200 / 30513"
+19711768-19719678 modbus: sc-data: "0x0008 / 8"
+19716344-19724254 modbus: cs-length: "Read 2161 units of data"
+19720920-19728829 modbus: sc-crc: "CRC correct"
+19724254-19730080 modbus: cs-error: "Message too short or not finished"
+19893433-19896767 modbus: sc-server-id: "Slave ID: 247"
+19893433-19896767 modbus: cs-server-id: "Slave ID: 247"
+19898082-19901416 modbus: sc-function: "Function 3: Read Holding Registers"
+19898082-19901416 modbus: cs-function: "Function 3: Read Holding Registers"
+19902753-19906087 modbus: sc-length: "Byte count: 64"
+19902753-19910737 modbus: cs-address: "Start at address 0x4082 / 46515"
+19907403-19915409 modbus: sc-data: "0x8200 / 33280"
+19912075-19920059 modbus: cs-length: "Read 2 units of data"
+19916725-19924730 modbus: sc-data: "0x0265 / 613"
+19921396-19929381 modbus: cs-crc: "CRC correct"
+19924730-19930632 modbus: sc-error: "Message too short or not finished"
+19948322-19951656 modbus: sc-server-id: "Slave ID: 247"
+19948322-19951656 modbus: cs-server-id: "Slave ID: 247"
+19952898-19956232 modbus: sc-function: "Function 3: Read Holding Registers"
+19952898-19956232 modbus: cs-function: "Function 3: Read Holding Registers"
+19957474-19960808 modbus: sc-length: "Byte count: 4"
+19957474-19965383 modbus: cs-address: "Start at address 0x400 / 31025"
+19962049-19969959 modbus: sc-data: "0x0000 / 0"
+19966625-19974534 modbus: cs-length: "Read 0 units of data"
+19971200-19979110 modbus: sc-data: "0x0003 / 3"
+19975776-19983686 modbus: cs-error: "CRC should be 80 108"
+19980352-19988261 modbus: sc-crc: "CRC correct"
+19984927-19988261 modbus: cs-error: "Unknown function"
diff --git a/decoder/test/modbus/flowmeter_target_20liter_per_min.output b/decoder/test/modbus/flowmeter_target_20liter_per_min.output
new file mode 100644 (file)
index 0000000..4da9009
--- /dev/null
@@ -0,0 +1,1155 @@
+19673-23007 modbus: sc-server-id: "Slave ID: 247"
+19673-23007 modbus: cs-server-id: "Slave ID: 247"
+24344-27678 modbus: sc-function: "Function 3: Read Holding Registers"
+24344-27678 modbus: cs-function: "Function 3: Read Holding Registers"
+28994-32328 modbus: sc-length: "Byte count: 64"
+28994-36999 modbus: cs-address: "Start at address 0x4082 / 46515"
+33665-41649 modbus: sc-data: "0x8200 / 33280"
+38315-46321 modbus: cs-length: "Read 2 units of data"
+42987-50971 modbus: sc-data: "0x0265 / 613"
+47637-55642 modbus: cs-crc: "CRC correct"
+50971-56893 modbus: sc-error: "Message too short or not finished"
+74582-77916 modbus: sc-server-id: "Slave ID: 247"
+74582-77916 modbus: cs-server-id: "Slave ID: 247"
+79157-82491 modbus: sc-function: "Function 3: Read Holding Registers"
+79157-82491 modbus: cs-function: "Function 3: Read Holding Registers"
+83733-87067 modbus: sc-length: "Byte count: 4"
+83733-91642 modbus: cs-address: "Start at address 0x400 / 31025"
+88308-96218 modbus: sc-data: "0x0000 / 0"
+92884-100793 modbus: cs-length: "Read 0 units of data"
+97459-105369 modbus: sc-data: "0x0003 / 3"
+102035-109945 modbus: cs-error: "CRC should be 80 108"
+106611-114520 modbus: sc-crc: "CRC correct"
+111186-114520 modbus: cs-error: "Unknown function"
+277371-280705 modbus: sc-server-id: "Slave ID: 247"
+277371-280705 modbus: cs-server-id: "Slave ID: 247"
+282041-285375 modbus: sc-function: "Function 3: Read Holding Registers"
+282041-285375 modbus: cs-function: "Function 3: Read Holding Registers"
+286691-290025 modbus: sc-length: "Byte count: 0"
+286691-294697 modbus: cs-address: "Start at address 0x0 / 30001"
+291363-299347 modbus: sc-error: "CRC should be 192 194"
+296013-304018 modbus: cs-length: "Read 15 units of data"
+300684-308668 modbus: sc-error: "Message too long"
+305334-313340 modbus: cs-crc: "CRC correct"
+330530-333864 modbus: sc-server-id: "Slave ID: 247"
+330530-333864 modbus: cs-server-id: "Slave ID: 247"
+335105-338439 modbus: sc-function: "Function 3: Read Holding Registers"
+335105-338439 modbus: cs-function: "Function 3: Read Holding Registers"
+339681-343015 modbus: sc-length: "Byte count: 30"
+339681-347590 modbus: cs-address: "Start at address 0x1E00 / 37681"
+344256-352166 modbus: sc-data: "0x0000 / 0"
+348832-356742 modbus: cs-length: "Read 0 units of data"
+353408-361317 modbus: sc-data: "0x0000 / 0"
+357983-365893 modbus: cs-error: "CRC should be 87 116"
+362559-370468 modbus: sc-data: "0x41B7 / 16823"
+367134-370468 modbus: cs-error: "Unknown function"
+371710-375044 modbus: cs-error: "Unknown function"
+371710-379620 modbus: sc-data: "0x7DC0 / 32192"
+376286-379620 modbus: cs-error: "Unknown function"
+380861-384195 modbus: cs-error: "Unknown function"
+380861-388771 modbus: sc-data: "0x3E57 / 15959"
+385437-388771 modbus: cs-error: "Unknown function"
+390013-393347 modbus: cs-error: "Unknown function"
+390013-397922 modbus: sc-data: "0x9E9F / 40607"
+394588-397922 modbus: cs-error: "Unknown function"
+399164-402498 modbus: cs-error: "Unknown function"
+399164-407073 modbus: sc-data: "0x0000 / 0"
+403739-407073 modbus: cs-error: "Unknown function"
+408315-411649 modbus: cs-error: "Unknown function"
+408315-416225 modbus: sc-data: "0x0000 / 0"
+412891-416225 modbus: cs-error: "Unknown function"
+417466-420800 modbus: cs-error: "Unknown function"
+417466-425376 modbus: sc-data: "0x3AC3 / 15043"
+422042-425376 modbus: cs-error: "Unknown function"
+426618-429952 modbus: cs-error: "Unknown function"
+426618-434527 modbus: sc-data: "0x0FB5 / 4021"
+431193-434527 modbus: cs-error: "Unknown function"
+435769-439103 modbus: cs-error: "Unknown function"
+435769-443678 modbus: sc-data: "0x0000 / 0"
+440344-443678 modbus: cs-error: "Unknown function"
+444920-448254 modbus: cs-error: "Unknown function"
+444920-452830 modbus: sc-data: "0x0000 / 0"
+449496-452830 modbus: cs-error: "Unknown function"
+454071-457405 modbus: cs-error: "Unknown function"
+454071-461981 modbus: sc-data: "0x0000 / 0"
+458647-461981 modbus: cs-error: "Unknown function"
+463222-466556 modbus: cs-error: "Unknown function"
+463222-471132 modbus: sc-data: "0x0000 / 0"
+467798-471132 modbus: cs-error: "Unknown function"
+472374-475708 modbus: cs-error: "Unknown function"
+472374-480283 modbus: sc-data: "0x0000 / 0"
+476949-480283 modbus: cs-error: "Unknown function"
+481525-484859 modbus: cs-error: "Unknown function"
+481525-489434 modbus: sc-crc: "CRC correct"
+486100-489434 modbus: cs-error: "Unknown function"
+583212-586546 modbus: sc-server-id: "Slave ID: 247"
+583212-586546 modbus: cs-server-id: "Slave ID: 247"
+587882-591216 modbus: sc-function: "Function 3: Read Holding Registers"
+587882-591216 modbus: cs-function: "Function 3: Read Holding Registers"
+592532-595866 modbus: sc-length: "Byte count: 0"
+592532-600538 modbus: cs-address: "Start at address 0xD / 30014"
+597204-605188 modbus: sc-error: "CRC should be 192 194"
+601854-609859 modbus: cs-length: "Read 1 units of data"
+606525-614510 modbus: sc-error: "Message too long"
+611176-619181 modbus: cs-crc: "CRC correct"
+636030-639364 modbus: sc-server-id: "Slave ID: 247"
+636030-639364 modbus: cs-server-id: "Slave ID: 247"
+640605-643939 modbus: sc-function: "Function 3: Read Holding Registers"
+640605-643939 modbus: cs-function: "Function 3: Read Holding Registers"
+645181-648515 modbus: sc-length: "Byte count: 2"
+645181-653091 modbus: cs-address: "Start at address 0x200 / 30513"
+649757-657666 modbus: sc-data: "0x0000 / 0"
+654332-662242 modbus: cs-length: "Read 112 units of data"
+658908-666817 modbus: sc-crc: "CRC correct"
+662242-668068 modbus: cs-error: "Message too short or not finished"
+831780-835114 modbus: sc-server-id: "Slave ID: 247"
+831780-835114 modbus: cs-server-id: "Slave ID: 247"
+836450-839784 modbus: sc-function: "Function 3: Read Holding Registers"
+836450-839784 modbus: cs-function: "Function 3: Read Holding Registers"
+841100-844434 modbus: sc-length: "Byte count: 64"
+841100-849106 modbus: cs-address: "Start at address 0x4082 / 46515"
+845772-853756 modbus: sc-data: "0x8200 / 33280"
+850422-858427 modbus: cs-length: "Read 2 units of data"
+855093-863077 modbus: sc-data: "0x0265 / 613"
+859743-867749 modbus: cs-crc: "CRC correct"
+863077-869000 modbus: sc-error: "Message too short or not finished"
+886700-890034 modbus: sc-server-id: "Slave ID: 247"
+886700-890034 modbus: cs-server-id: "Slave ID: 247"
+891276-894610 modbus: sc-function: "Function 3: Read Holding Registers"
+891276-894610 modbus: cs-function: "Function 3: Read Holding Registers"
+895852-899186 modbus: sc-length: "Byte count: 4"
+895852-903761 modbus: cs-address: "Start at address 0x400 / 31025"
+900427-908337 modbus: sc-data: "0x0000 / 0"
+905003-912912 modbus: cs-length: "Read 0 units of data"
+909578-917488 modbus: sc-data: "0x0003 / 3"
+914154-922064 modbus: cs-error: "CRC should be 80 108"
+918730-926639 modbus: sc-crc: "CRC correct"
+923305-926639 modbus: cs-error: "Unknown function"
+1089648-1092982 modbus: sc-server-id: "Slave ID: 247"
+1089648-1092982 modbus: cs-server-id: "Slave ID: 247"
+1094318-1097652 modbus: sc-function: "Function 3: Read Holding Registers"
+1094318-1097652 modbus: cs-function: "Function 3: Read Holding Registers"
+1098968-1102302 modbus: sc-length: "Byte count: 0"
+1098968-1106974 modbus: cs-address: "Start at address 0x0 / 30001"
+1103640-1111624 modbus: sc-error: "CRC should be 192 194"
+1108290-1116295 modbus: cs-length: "Read 15 units of data"
+1112961-1120946 modbus: sc-error: "Message too long"
+1117612-1125617 modbus: cs-crc: "CRC correct"
+1144677-1148011 modbus: sc-server-id: "Slave ID: 247"
+1144677-1148011 modbus: cs-server-id: "Slave ID: 247"
+1149252-1152586 modbus: sc-function: "Function 3: Read Holding Registers"
+1149252-1152586 modbus: cs-function: "Function 3: Read Holding Registers"
+1153828-1157162 modbus: sc-length: "Byte count: 30"
+1153828-1161737 modbus: cs-address: "Start at address 0x1E00 / 37681"
+1158403-1166313 modbus: sc-data: "0x0000 / 0"
+1162979-1170888 modbus: cs-length: "Read 0 units of data"
+1167554-1175464 modbus: sc-data: "0x0000 / 0"
+1172130-1180040 modbus: cs-error: "CRC should be 87 116"
+1176706-1184615 modbus: sc-data: "0x41B7 / 16823"
+1181281-1184615 modbus: cs-error: "Unknown function"
+1185857-1189191 modbus: cs-error: "Unknown function"
+1185857-1193767 modbus: sc-data: "0x82A4 / 33444"
+1190433-1193767 modbus: cs-error: "Unknown function"
+1195008-1198342 modbus: cs-error: "Unknown function"
+1195008-1202918 modbus: sc-data: "0x3E57 / 15959"
+1199584-1202918 modbus: cs-error: "Unknown function"
+1204159-1207493 modbus: cs-error: "Unknown function"
+1204159-1212069 modbus: sc-data: "0x9E9F / 40607"
+1208735-1212069 modbus: cs-error: "Unknown function"
+1213311-1216645 modbus: cs-error: "Unknown function"
+1213311-1221220 modbus: sc-data: "0x0000 / 0"
+1217886-1221220 modbus: cs-error: "Unknown function"
+1222462-1225796 modbus: cs-error: "Unknown function"
+1222462-1230371 modbus: sc-data: "0x0000 / 0"
+1227037-1230371 modbus: cs-error: "Unknown function"
+1231613-1234947 modbus: cs-error: "Unknown function"
+1231613-1239523 modbus: sc-data: "0x3AC3 / 15043"
+1236189-1239523 modbus: cs-error: "Unknown function"
+1240764-1244098 modbus: cs-error: "Unknown function"
+1240764-1248674 modbus: sc-data: "0x0FB5 / 4021"
+1245340-1248674 modbus: cs-error: "Unknown function"
+1249916-1253250 modbus: cs-error: "Unknown function"
+1249916-1257825 modbus: sc-data: "0x0000 / 0"
+1254491-1257825 modbus: cs-error: "Unknown function"
+1259067-1262401 modbus: cs-error: "Unknown function"
+1259067-1266976 modbus: sc-data: "0x0000 / 0"
+1263642-1266976 modbus: cs-error: "Unknown function"
+1268218-1271552 modbus: cs-error: "Unknown function"
+1268218-1276128 modbus: sc-data: "0x0000 / 0"
+1272794-1276128 modbus: cs-error: "Unknown function"
+1277369-1280703 modbus: cs-error: "Unknown function"
+1277369-1285279 modbus: sc-data: "0x0000 / 0"
+1281945-1285279 modbus: cs-error: "Unknown function"
+1286520-1289854 modbus: cs-error: "Unknown function"
+1286520-1294430 modbus: sc-data: "0x0000 / 0"
+1291096-1294430 modbus: cs-error: "Unknown function"
+1295672-1299006 modbus: cs-error: "Unknown function"
+1295672-1303581 modbus: sc-crc: "CRC correct"
+1300247-1303581 modbus: cs-error: "Unknown function"
+1396108-1399442 modbus: sc-server-id: "Slave ID: 247"
+1396108-1399442 modbus: cs-server-id: "Slave ID: 247"
+1400778-1404112 modbus: sc-function: "Function 3: Read Holding Registers"
+1400778-1404112 modbus: cs-function: "Function 3: Read Holding Registers"
+1405428-1408762 modbus: sc-length: "Byte count: 0"
+1405428-1413433 modbus: cs-address: "Start at address 0xD / 30014"
+1410099-1418084 modbus: sc-error: "CRC should be 192 194"
+1414750-1422755 modbus: cs-length: "Read 1 units of data"
+1419421-1427405 modbus: sc-error: "Message too long"
+1424071-1432077 modbus: cs-crc: "CRC correct"
+1448929-1452263 modbus: sc-server-id: "Slave ID: 247"
+1448929-1452263 modbus: cs-server-id: "Slave ID: 247"
+1453504-1456838 modbus: sc-function: "Function 3: Read Holding Registers"
+1453504-1456838 modbus: cs-function: "Function 3: Read Holding Registers"
+1458080-1461414 modbus: sc-length: "Byte count: 2"
+1458080-1465989 modbus: cs-address: "Start at address 0x200 / 30513"
+1462655-1470565 modbus: sc-data: "0x0000 / 0"
+1467231-1475141 modbus: cs-length: "Read 112 units of data"
+1471807-1479716 modbus: sc-crc: "CRC correct"
+1475141-1480967 modbus: cs-error: "Message too short or not finished"
+1644505-1647839 modbus: sc-server-id: "Slave ID: 247"
+1644505-1647839 modbus: cs-server-id: "Slave ID: 247"
+1649175-1652509 modbus: sc-function: "Function 3: Read Holding Registers"
+1649175-1652509 modbus: cs-function: "Function 3: Read Holding Registers"
+1653825-1657159 modbus: sc-length: "Byte count: 64"
+1653825-1661831 modbus: cs-address: "Start at address 0x4082 / 46515"
+1658497-1666481 modbus: sc-data: "0x8200 / 33280"
+1663147-1671152 modbus: cs-length: "Read 2 units of data"
+1667818-1675803 modbus: sc-data: "0x0265 / 613"
+1672469-1680474 modbus: cs-crc: "CRC correct"
+1675803-1681725 modbus: sc-error: "Message too short or not finished"
+1699417-1702751 modbus: sc-server-id: "Slave ID: 247"
+1699417-1702751 modbus: cs-server-id: "Slave ID: 247"
+1703993-1707327 modbus: sc-function: "Function 3: Read Holding Registers"
+1703993-1707327 modbus: cs-function: "Function 3: Read Holding Registers"
+1708568-1711902 modbus: sc-length: "Byte count: 4"
+1708568-1716478 modbus: cs-address: "Start at address 0x400 / 31025"
+1713144-1721054 modbus: sc-data: "0x0000 / 0"
+1717720-1725629 modbus: cs-length: "Read 0 units of data"
+1722295-1730205 modbus: sc-data: "0x0003 / 3"
+1726871-1734781 modbus: cs-error: "CRC should be 80 108"
+1731447-1739356 modbus: sc-crc: "CRC correct"
+1736022-1739356 modbus: cs-error: "Unknown function"
+1902458-1905792 modbus: sc-server-id: "Slave ID: 247"
+1902458-1905792 modbus: cs-server-id: "Slave ID: 247"
+1907129-1910463 modbus: sc-function: "Function 3: Read Holding Registers"
+1907129-1910463 modbus: cs-function: "Function 3: Read Holding Registers"
+1911779-1915113 modbus: sc-length: "Byte count: 0"
+1911779-1919784 modbus: cs-address: "Start at address 0x0 / 30001"
+1916450-1924434 modbus: sc-error: "CRC should be 192 194"
+1921100-1929106 modbus: cs-length: "Read 15 units of data"
+1925772-1933756 modbus: sc-error: "Message too long"
+1930422-1938427 modbus: cs-crc: "CRC correct"
+1955626-1958960 modbus: sc-server-id: "Slave ID: 247"
+1955626-1958960 modbus: cs-server-id: "Slave ID: 247"
+1960201-1963535 modbus: sc-function: "Function 3: Read Holding Registers"
+1960201-1963535 modbus: cs-function: "Function 3: Read Holding Registers"
+1964777-1968111 modbus: sc-length: "Byte count: 30"
+1964777-1972686 modbus: cs-address: "Start at address 0x1E00 / 37681"
+1969352-1977262 modbus: sc-data: "0x0000 / 0"
+1973928-1981838 modbus: cs-length: "Read 0 units of data"
+1978504-1986413 modbus: sc-data: "0x0000 / 0"
+1983079-1990989 modbus: cs-error: "CRC should be 87 116"
+1987655-1995564 modbus: sc-data: "0x41B7 / 16823"
+1992230-1995564 modbus: cs-error: "Unknown function"
+1996806-2000140 modbus: cs-error: "Unknown function"
+1996806-2004716 modbus: sc-data: "0x82A4 / 33444"
+2001382-2004716 modbus: cs-error: "Unknown function"
+2005957-2009291 modbus: cs-error: "Unknown function"
+2005957-2013867 modbus: sc-data: "0x3E57 / 15959"
+2010533-2013867 modbus: cs-error: "Unknown function"
+2015108-2018442 modbus: cs-error: "Unknown function"
+2015108-2023018 modbus: sc-data: "0x9E9F / 40607"
+2019684-2023018 modbus: cs-error: "Unknown function"
+2024260-2027594 modbus: cs-error: "Unknown function"
+2024260-2032169 modbus: sc-data: "0x0000 / 0"
+2028835-2032169 modbus: cs-error: "Unknown function"
+2033411-2036745 modbus: cs-error: "Unknown function"
+2033411-2041320 modbus: sc-data: "0x0000 / 0"
+2037986-2041320 modbus: cs-error: "Unknown function"
+2042562-2045896 modbus: cs-error: "Unknown function"
+2042562-2050472 modbus: sc-data: "0x0000 / 0"
+2047138-2050472 modbus: cs-error: "Unknown function"
+2051713-2055047 modbus: cs-error: "Unknown function"
+2051713-2059623 modbus: sc-data: "0x0000 / 0"
+2056289-2059623 modbus: cs-error: "Unknown function"
+2060865-2064199 modbus: cs-error: "Unknown function"
+2060865-2068774 modbus: sc-data: "0x0000 / 0"
+2065440-2068774 modbus: cs-error: "Unknown function"
+2070016-2073350 modbus: cs-error: "Unknown function"
+2070016-2077925 modbus: sc-data: "0x0000 / 0"
+2074591-2077925 modbus: cs-error: "Unknown function"
+2079167-2082501 modbus: cs-error: "Unknown function"
+2079167-2087077 modbus: sc-data: "0x0000 / 0"
+2083743-2087077 modbus: cs-error: "Unknown function"
+2088318-2091652 modbus: cs-error: "Unknown function"
+2088318-2096228 modbus: sc-data: "0x0000 / 0"
+2092894-2096228 modbus: cs-error: "Unknown function"
+2097469-2100803 modbus: cs-error: "Unknown function"
+2097469-2105379 modbus: sc-data: "0x0000 / 0"
+2102045-2105379 modbus: cs-error: "Unknown function"
+2106621-2109955 modbus: cs-error: "Unknown function"
+2106621-2114530 modbus: sc-crc: "CRC correct"
+2111196-2114530 modbus: cs-error: "Unknown function"
+2271673-2275007 modbus: sc-server-id: "Slave ID: 247"
+2271673-2275007 modbus: cs-server-id: "Slave ID: 247"
+2276344-2279678 modbus: sc-function: "Function 3: Read Holding Registers"
+2276344-2279678 modbus: cs-function: "Function 3: Read Holding Registers"
+2280994-2284328 modbus: sc-length: "Byte count: 0"
+2280994-2288999 modbus: cs-address: "Start at address 0xD / 30014"
+2285665-2293649 modbus: sc-error: "CRC should be 192 194"
+2290315-2298321 modbus: cs-length: "Read 1 units of data"
+2294987-2302971 modbus: sc-error: "Message too long"
+2299637-2307642 modbus: cs-crc: "CRC correct"
+2324508-2327842 modbus: sc-server-id: "Slave ID: 247"
+2324508-2327842 modbus: cs-server-id: "Slave ID: 247"
+2329084-2332418 modbus: sc-function: "Function 3: Read Holding Registers"
+2329084-2332418 modbus: cs-function: "Function 3: Read Holding Registers"
+2333659-2336993 modbus: sc-length: "Byte count: 2"
+2333659-2341569 modbus: cs-address: "Start at address 0x200 / 30513"
+2338235-2346145 modbus: sc-data: "0x0000 / 0"
+2342811-2350720 modbus: cs-length: "Read 112 units of data"
+2347386-2355296 modbus: sc-crc: "CRC correct"
+2350720-2356547 modbus: cs-error: "Message too short or not finished"
+2519388-2522722 modbus: sc-server-id: "Slave ID: 247"
+2519388-2522722 modbus: cs-server-id: "Slave ID: 247"
+2524058-2527392 modbus: sc-function: "Function 3: Read Holding Registers"
+2524058-2527392 modbus: cs-function: "Function 3: Read Holding Registers"
+2528708-2532042 modbus: sc-length: "Byte count: 64"
+2528708-2536714 modbus: cs-address: "Start at address 0x4082 / 46515"
+2533380-2541364 modbus: sc-data: "0x8200 / 33280"
+2538030-2546036 modbus: cs-length: "Read 2 units of data"
+2542702-2550686 modbus: sc-data: "0x0265 / 613"
+2547352-2555357 modbus: cs-crc: "CRC correct"
+2550686-2556608 modbus: sc-error: "Message too short or not finished"
+2574295-2577629 modbus: sc-server-id: "Slave ID: 247"
+2574295-2577629 modbus: cs-server-id: "Slave ID: 247"
+2578871-2582205 modbus: sc-function: "Function 3: Read Holding Registers"
+2578871-2582205 modbus: cs-function: "Function 3: Read Holding Registers"
+2583446-2586780 modbus: sc-length: "Byte count: 4"
+2583446-2591356 modbus: cs-address: "Start at address 0x400 / 31025"
+2588022-2595931 modbus: sc-data: "0x0000 / 0"
+2592597-2600507 modbus: cs-length: "Read 0 units of data"
+2597173-2605083 modbus: sc-data: "0x0003 / 3"
+2601749-2609658 modbus: cs-error: "CRC should be 80 108"
+2606324-2614234 modbus: sc-crc: "CRC correct"
+2610900-2614234 modbus: cs-error: "Unknown function"
+2778173-2781507 modbus: sc-server-id: "Slave ID: 247"
+2778173-2781507 modbus: cs-server-id: "Slave ID: 247"
+2782844-2786178 modbus: sc-function: "Function 3: Read Holding Registers"
+2782844-2786178 modbus: cs-function: "Function 3: Read Holding Registers"
+2787494-2790828 modbus: sc-length: "Byte count: 0"
+2787494-2795499 modbus: cs-address: "Start at address 0x0 / 30001"
+2792165-2800149 modbus: sc-error: "CRC should be 192 194"
+2796815-2804821 modbus: cs-length: "Read 15 units of data"
+2801487-2809471 modbus: sc-error: "Message too long"
+2806137-2814142 modbus: cs-crc: "CRC correct"
+2831335-2834669 modbus: sc-server-id: "Slave ID: 247"
+2831335-2834669 modbus: cs-server-id: "Slave ID: 247"
+2835911-2839245 modbus: sc-function: "Function 3: Read Holding Registers"
+2835911-2839245 modbus: cs-function: "Function 3: Read Holding Registers"
+2840486-2843820 modbus: sc-length: "Byte count: 30"
+2840486-2848396 modbus: cs-address: "Start at address 0x1E00 / 37681"
+2845062-2852971 modbus: sc-data: "0x0000 / 0"
+2849637-2857547 modbus: cs-length: "Read 0 units of data"
+2854213-2862123 modbus: sc-data: "0x0000 / 0"
+2858789-2866698 modbus: cs-error: "CRC should be 87 116"
+2863364-2871274 modbus: sc-data: "0x41B7 / 16823"
+2867940-2871274 modbus: cs-error: "Unknown function"
+2872516-2875850 modbus: cs-error: "Unknown function"
+2872516-2880425 modbus: sc-data: "0x82A4 / 33444"
+2877091-2880425 modbus: cs-error: "Unknown function"
+2881667-2885001 modbus: cs-error: "Unknown function"
+2881667-2889576 modbus: sc-data: "0x3E57 / 15959"
+2886242-2889576 modbus: cs-error: "Unknown function"
+2890818-2894152 modbus: cs-error: "Unknown function"
+2890818-2898728 modbus: sc-data: "0x9E9F / 40607"
+2895394-2898728 modbus: cs-error: "Unknown function"
+2899969-2903303 modbus: cs-error: "Unknown function"
+2899969-2907879 modbus: sc-data: "0x0000 / 0"
+2904545-2907879 modbus: cs-error: "Unknown function"
+2909120-2912454 modbus: cs-error: "Unknown function"
+2909120-2917030 modbus: sc-data: "0x0000 / 0"
+2913696-2917030 modbus: cs-error: "Unknown function"
+2918272-2921606 modbus: cs-error: "Unknown function"
+2918272-2926181 modbus: sc-data: "0x3AC3 / 15043"
+2922847-2926181 modbus: cs-error: "Unknown function"
+2927423-2930757 modbus: cs-error: "Unknown function"
+2927423-2935332 modbus: sc-data: "0x0FB5 / 4021"
+2931998-2935332 modbus: cs-error: "Unknown function"
+2936574-2939908 modbus: cs-error: "Unknown function"
+2936574-2944484 modbus: sc-data: "0x0000 / 0"
+2941150-2944484 modbus: cs-error: "Unknown function"
+2945725-2949059 modbus: cs-error: "Unknown function"
+2945725-2953635 modbus: sc-data: "0x0000 / 0"
+2950301-2953635 modbus: cs-error: "Unknown function"
+2954876-2958210 modbus: cs-error: "Unknown function"
+2954876-2962786 modbus: sc-data: "0x0000 / 0"
+2959452-2962786 modbus: cs-error: "Unknown function"
+2964028-2967362 modbus: cs-error: "Unknown function"
+2964028-2971937 modbus: sc-data: "0x0000 / 0"
+2968603-2971937 modbus: cs-error: "Unknown function"
+2973179-2976513 modbus: cs-error: "Unknown function"
+2973179-2981089 modbus: sc-data: "0x0000 / 0"
+2977755-2981089 modbus: cs-error: "Unknown function"
+2982330-2985664 modbus: cs-error: "Unknown function"
+2982330-2990240 modbus: sc-crc: "CRC correct"
+2986906-2990240 modbus: cs-error: "Unknown function"
+3082692-3086026 modbus: sc-server-id: "Slave ID: 247"
+3082692-3086026 modbus: cs-server-id: "Slave ID: 247"
+3087362-3090696 modbus: sc-function: "Function 3: Read Holding Registers"
+3087362-3090696 modbus: cs-function: "Function 3: Read Holding Registers"
+3092012-3095346 modbus: sc-length: "Byte count: 0"
+3092012-3100018 modbus: cs-address: "Start at address 0xD / 30014"
+3096684-3104668 modbus: sc-error: "CRC should be 192 194"
+3101334-3109339 modbus: cs-length: "Read 1 units of data"
+3106005-3113990 modbus: sc-error: "Message too long"
+3110656-3118661 modbus: cs-crc: "CRC correct"
+3135509-3138843 modbus: sc-server-id: "Slave ID: 247"
+3135509-3138843 modbus: cs-server-id: "Slave ID: 247"
+3140085-3143419 modbus: sc-function: "Function 3: Read Holding Registers"
+3140085-3143419 modbus: cs-function: "Function 3: Read Holding Registers"
+3144660-3147994 modbus: sc-length: "Byte count: 2"
+3144660-3152570 modbus: cs-address: "Start at address 0x200 / 30513"
+3149236-3157146 modbus: sc-data: "0x0000 / 0"
+3153812-3161721 modbus: cs-length: "Read 112 units of data"
+3158387-3166297 modbus: sc-crc: "CRC correct"
+3161721-3167548 modbus: cs-error: "Message too short or not finished"
+3332326-3335660 modbus: sc-server-id: "Slave ID: 247"
+3332326-3335660 modbus: cs-server-id: "Slave ID: 247"
+3336997-3340331 modbus: sc-function: "Function 3: Read Holding Registers"
+3336997-3340331 modbus: cs-function: "Function 3: Read Holding Registers"
+3341647-3344981 modbus: sc-length: "Byte count: 64"
+3341647-3349652 modbus: cs-address: "Start at address 0x4082 / 46515"
+3346318-3354302 modbus: sc-data: "0x8200 / 33280"
+3350968-3358974 modbus: cs-length: "Read 2 units of data"
+3355640-3363624 modbus: sc-data: "0x0265 / 613"
+3360290-3368295 modbus: cs-crc: "CRC correct"
+3363624-3369546 modbus: sc-error: "Message too short or not finished"
+3387246-3390580 modbus: sc-server-id: "Slave ID: 247"
+3387246-3390580 modbus: cs-server-id: "Slave ID: 247"
+3391821-3395155 modbus: sc-function: "Function 3: Read Holding Registers"
+3391821-3395155 modbus: cs-function: "Function 3: Read Holding Registers"
+3396397-3399731 modbus: sc-length: "Byte count: 4"
+3396397-3404307 modbus: cs-address: "Start at address 0x400 / 31025"
+3400973-3408882 modbus: sc-data: "0x0000 / 0"
+3405548-3413458 modbus: cs-length: "Read 0 units of data"
+3410124-3418033 modbus: sc-data: "0x0003 / 3"
+3414699-3422609 modbus: cs-error: "CRC should be 80 108"
+3419275-3427185 modbus: sc-crc: "CRC correct"
+3423851-3427185 modbus: cs-error: "Unknown function"
+3590195-3593529 modbus: sc-server-id: "Slave ID: 247"
+3590195-3593529 modbus: cs-server-id: "Slave ID: 247"
+3594865-3598199 modbus: sc-function: "Function 3: Read Holding Registers"
+3594865-3598199 modbus: cs-function: "Function 3: Read Holding Registers"
+3599515-3602849 modbus: sc-length: "Byte count: 0"
+3599515-3607521 modbus: cs-address: "Start at address 0x0 / 30001"
+3604187-3612171 modbus: sc-error: "CRC should be 192 194"
+3608837-3616842 modbus: cs-length: "Read 15 units of data"
+3613508-3621492 modbus: sc-error: "Message too long"
+3618158-3626164 modbus: cs-crc: "CRC correct"
+3643350-3646684 modbus: sc-server-id: "Slave ID: 247"
+3643350-3646684 modbus: cs-server-id: "Slave ID: 247"
+3647926-3651260 modbus: sc-function: "Function 3: Read Holding Registers"
+3647926-3651260 modbus: cs-function: "Function 3: Read Holding Registers"
+3652501-3655835 modbus: sc-length: "Byte count: 30"
+3652501-3660411 modbus: cs-address: "Start at address 0x1E00 / 37681"
+3657077-3664986 modbus: sc-data: "0x0000 / 0"
+3661652-3669562 modbus: cs-length: "Read 0 units of data"
+3666228-3674138 modbus: sc-data: "0x0000 / 0"
+3670804-3678713 modbus: cs-error: "CRC should be 87 116"
+3675379-3683289 modbus: sc-data: "0x41B7 / 16823"
+3679955-3683289 modbus: cs-error: "Unknown function"
+3684530-3687864 modbus: cs-error: "Unknown function"
+3684530-3692440 modbus: sc-data: "0x82A4 / 33444"
+3689106-3692440 modbus: cs-error: "Unknown function"
+3693682-3697016 modbus: cs-error: "Unknown function"
+3693682-3701591 modbus: sc-data: "0x3E57 / 15959"
+3698257-3701591 modbus: cs-error: "Unknown function"
+3702833-3706167 modbus: cs-error: "Unknown function"
+3702833-3710743 modbus: sc-data: "0x9E9F / 40607"
+3707409-3710743 modbus: cs-error: "Unknown function"
+3711984-3715318 modbus: cs-error: "Unknown function"
+3711984-3719894 modbus: sc-data: "0x0000 / 0"
+3716560-3719894 modbus: cs-error: "Unknown function"
+3721135-3724469 modbus: cs-error: "Unknown function"
+3721135-3729045 modbus: sc-data: "0x0000 / 0"
+3725711-3729045 modbus: cs-error: "Unknown function"
+3730287-3733621 modbus: cs-error: "Unknown function"
+3730287-3738196 modbus: sc-data: "0x3AC3 / 15043"
+3734862-3738196 modbus: cs-error: "Unknown function"
+3739438-3742772 modbus: cs-error: "Unknown function"
+3739438-3747347 modbus: sc-data: "0x0FB5 / 4021"
+3744013-3747347 modbus: cs-error: "Unknown function"
+3748589-3751923 modbus: cs-error: "Unknown function"
+3748589-3756499 modbus: sc-data: "0x0000 / 0"
+3753165-3756499 modbus: cs-error: "Unknown function"
+3757740-3761074 modbus: cs-error: "Unknown function"
+3757740-3765650 modbus: sc-data: "0x0000 / 0"
+3762316-3765650 modbus: cs-error: "Unknown function"
+3766891-3770225 modbus: cs-error: "Unknown function"
+3766891-3774801 modbus: sc-data: "0x0000 / 0"
+3771467-3774801 modbus: cs-error: "Unknown function"
+3776043-3779377 modbus: cs-error: "Unknown function"
+3776043-3783952 modbus: sc-data: "0x0000 / 0"
+3780618-3783952 modbus: cs-error: "Unknown function"
+3785194-3788528 modbus: cs-error: "Unknown function"
+3785194-3793103 modbus: sc-data: "0x0000 / 0"
+3789769-3793103 modbus: cs-error: "Unknown function"
+3794345-3797679 modbus: cs-error: "Unknown function"
+3794345-3802255 modbus: sc-crc: "CRC correct"
+3798921-3802255 modbus: cs-error: "Unknown function"
+3895609-3898943 modbus: sc-server-id: "Slave ID: 247"
+3895609-3898943 modbus: cs-server-id: "Slave ID: 247"
+3900280-3903614 modbus: sc-function: "Function 3: Read Holding Registers"
+3900280-3903614 modbus: cs-function: "Function 3: Read Holding Registers"
+3904929-3908263 modbus: sc-length: "Byte count: 0"
+3904929-3912935 modbus: cs-address: "Start at address 0xD / 30014"
+3909601-3917585 modbus: sc-error: "CRC should be 192 194"
+3914251-3922257 modbus: cs-length: "Read 1 units of data"
+3918923-3926907 modbus: sc-error: "Message too long"
+3923573-3931578 modbus: cs-crc: "CRC correct"
+3948434-3951768 modbus: sc-server-id: "Slave ID: 247"
+3948434-3951768 modbus: cs-server-id: "Slave ID: 247"
+3953010-3956344 modbus: sc-function: "Function 3: Read Holding Registers"
+3953010-3956344 modbus: cs-function: "Function 3: Read Holding Registers"
+3957585-3960919 modbus: sc-length: "Byte count: 2"
+3957585-3965495 modbus: cs-address: "Start at address 0x200 / 30513"
+3962161-3970070 modbus: sc-data: "0x0000 / 0"
+3966736-3974646 modbus: cs-length: "Read 112 units of data"
+3971312-3979222 modbus: sc-crc: "CRC correct"
+3974646-3980473 modbus: cs-error: "Message too short or not finished"
+4145052-4148386 modbus: sc-server-id: "Slave ID: 247"
+4145052-4148386 modbus: cs-server-id: "Slave ID: 247"
+4149722-4153056 modbus: sc-function: "Function 3: Read Holding Registers"
+4149722-4153056 modbus: cs-function: "Function 3: Read Holding Registers"
+4154372-4157706 modbus: sc-length: "Byte count: 64"
+4154372-4162377 modbus: cs-address: "Start at address 0x4082 / 46515"
+4159043-4167028 modbus: sc-data: "0x8200 / 33280"
+4163694-4171699 modbus: cs-length: "Read 2 units of data"
+4168365-4176349 modbus: sc-data: "0x0265 / 613"
+4173015-4181021 modbus: cs-crc: "CRC correct"
+4176349-4182272 modbus: sc-error: "Message too short or not finished"
+4199963-4203297 modbus: sc-server-id: "Slave ID: 247"
+4199963-4203297 modbus: cs-server-id: "Slave ID: 247"
+4204538-4207872 modbus: sc-function: "Function 3: Read Holding Registers"
+4204538-4207872 modbus: cs-function: "Function 3: Read Holding Registers"
+4209114-4212448 modbus: sc-length: "Byte count: 4"
+4209114-4217023 modbus: cs-address: "Start at address 0x400 / 31025"
+4213689-4221599 modbus: sc-data: "0x0000 / 0"
+4218265-4226175 modbus: cs-length: "Read 0 units of data"
+4222841-4230750 modbus: sc-data: "0x0003 / 3"
+4227416-4235326 modbus: cs-error: "CRC should be 80 108"
+4231992-4239902 modbus: sc-crc: "CRC correct"
+4236568-4239902 modbus: cs-error: "Unknown function"
+4402685-4406019 modbus: sc-server-id: "Slave ID: 247"
+4402685-4406019 modbus: cs-server-id: "Slave ID: 247"
+4407355-4410689 modbus: sc-function: "Function 3: Read Holding Registers"
+4407355-4410689 modbus: cs-function: "Function 3: Read Holding Registers"
+4412006-4415340 modbus: sc-length: "Byte count: 0"
+4412006-4420011 modbus: cs-address: "Start at address 0x0 / 30001"
+4416677-4424661 modbus: sc-error: "CRC should be 192 194"
+4421327-4429332 modbus: cs-length: "Read 15 units of data"
+4425998-4433983 modbus: sc-error: "Message too long"
+4430649-4438654 modbus: cs-crc: "CRC correct"
+4455859-4459193 modbus: sc-server-id: "Slave ID: 247"
+4455859-4459193 modbus: cs-server-id: "Slave ID: 247"
+4460435-4463769 modbus: sc-function: "Function 3: Read Holding Registers"
+4460435-4463769 modbus: cs-function: "Function 3: Read Holding Registers"
+4465010-4468344 modbus: sc-length: "Byte count: 30"
+4465010-4472920 modbus: cs-address: "Start at address 0x1E00 / 37681"
+4469586-4477495 modbus: sc-data: "0x0000 / 0"
+4474161-4482071 modbus: cs-length: "Read 0 units of data"
+4478737-4486647 modbus: sc-data: "0x0000 / 0"
+4483313-4491222 modbus: cs-error: "CRC should be 87 116"
+4487888-4495798 modbus: sc-data: "0x41B7 / 16823"
+4492464-4495798 modbus: cs-error: "Unknown function"
+4497039-4500373 modbus: cs-error: "Unknown function"
+4497039-4504949 modbus: sc-data: "0x82A4 / 33444"
+4501615-4504949 modbus: cs-error: "Unknown function"
+4506191-4509525 modbus: cs-error: "Unknown function"
+4506191-4514100 modbus: sc-data: "0x3E57 / 15959"
+4510766-4514100 modbus: cs-error: "Unknown function"
+4515342-4518676 modbus: cs-error: "Unknown function"
+4515342-4523251 modbus: sc-data: "0x9E9F / 40607"
+4519917-4523251 modbus: cs-error: "Unknown function"
+4524493-4527827 modbus: cs-error: "Unknown function"
+4524493-4532403 modbus: sc-data: "0x0000 / 0"
+4529069-4532403 modbus: cs-error: "Unknown function"
+4533644-4536978 modbus: cs-error: "Unknown function"
+4533644-4541554 modbus: sc-data: "0x0000 / 0"
+4538220-4541554 modbus: cs-error: "Unknown function"
+4542795-4546129 modbus: cs-error: "Unknown function"
+4542795-4550705 modbus: sc-data: "0x3C5B / 15451"
+4547371-4550705 modbus: cs-error: "Unknown function"
+4551947-4555281 modbus: cs-error: "Unknown function"
+4551947-4559856 modbus: sc-data: "0x71AC / 29100"
+4556522-4559856 modbus: cs-error: "Unknown function"
+4561098-4564432 modbus: cs-error: "Unknown function"
+4561098-4569008 modbus: sc-data: "0x0000 / 0"
+4565674-4569008 modbus: cs-error: "Unknown function"
+4570249-4573583 modbus: cs-error: "Unknown function"
+4570249-4578159 modbus: sc-data: "0x0000 / 0"
+4574825-4578159 modbus: cs-error: "Unknown function"
+4579400-4582734 modbus: cs-error: "Unknown function"
+4579400-4587310 modbus: sc-data: "0x0000 / 0"
+4583976-4587310 modbus: cs-error: "Unknown function"
+4588552-4591886 modbus: cs-error: "Unknown function"
+4588552-4596461 modbus: sc-data: "0x0000 / 0"
+4593127-4596461 modbus: cs-error: "Unknown function"
+4597703-4601037 modbus: cs-error: "Unknown function"
+4597703-4605612 modbus: sc-data: "0x0000 / 0"
+4602278-4605612 modbus: cs-error: "Unknown function"
+4606854-4610188 modbus: cs-error: "Unknown function"
+4606854-4614764 modbus: sc-crc: "CRC correct"
+4611430-4614764 modbus: cs-error: "Unknown function"
+4708292-4711626 modbus: sc-server-id: "Slave ID: 247"
+4708292-4711626 modbus: cs-server-id: "Slave ID: 247"
+4712962-4716296 modbus: sc-function: "Function 3: Read Holding Registers"
+4712962-4716296 modbus: cs-function: "Function 3: Read Holding Registers"
+4717612-4720946 modbus: sc-length: "Byte count: 0"
+4717612-4725617 modbus: cs-address: "Start at address 0xD / 30014"
+4722283-4730268 modbus: sc-error: "CRC should be 192 194"
+4726934-4734939 modbus: cs-length: "Read 1 units of data"
+4731605-4739589 modbus: sc-error: "Message too long"
+4736255-4744261 modbus: cs-crc: "CRC correct"
+4761125-4764459 modbus: sc-server-id: "Slave ID: 247"
+4761125-4764459 modbus: cs-server-id: "Slave ID: 247"
+4765701-4769035 modbus: sc-function: "Function 3: Read Holding Registers"
+4765701-4769035 modbus: cs-function: "Function 3: Read Holding Registers"
+4770276-4773610 modbus: sc-length: "Byte count: 2"
+4770276-4778186 modbus: cs-address: "Start at address 0x200 / 30513"
+4774852-4782761 modbus: sc-data: "0x0000 / 0"
+4779427-4787337 modbus: cs-length: "Read 112 units of data"
+4784003-4791913 modbus: sc-crc: "CRC correct"
+4787337-4793164 modbus: cs-error: "Message too short or not finished"
+4957158-4960492 modbus: sc-server-id: "Slave ID: 247"
+4957158-4960492 modbus: cs-server-id: "Slave ID: 247"
+4961828-4965162 modbus: sc-function: "Function 3: Read Holding Registers"
+4961828-4965162 modbus: cs-function: "Function 3: Read Holding Registers"
+4966479-4969813 modbus: sc-length: "Byte count: 64"
+4966479-4974484 modbus: cs-address: "Start at address 0x4082 / 46515"
+4971150-4979134 modbus: sc-data: "0x8200 / 33280"
+4975800-4983806 modbus: cs-length: "Read 2 units of data"
+4980472-4988456 modbus: sc-data: "0x0265 / 613"
+4985122-4993127 modbus: cs-crc: "CRC correct"
+4988456-4994378 modbus: sc-error: "Message too short or not finished"
+5012082-5015416 modbus: sc-server-id: "Slave ID: 247"
+5012082-5015416 modbus: cs-server-id: "Slave ID: 247"
+5016657-5019991 modbus: sc-function: "Function 3: Read Holding Registers"
+5016657-5019991 modbus: cs-function: "Function 3: Read Holding Registers"
+5021233-5024567 modbus: sc-length: "Byte count: 4"
+5021233-5029142 modbus: cs-address: "Start at address 0x400 / 31025"
+5025808-5033718 modbus: sc-data: "0x0000 / 0"
+5030384-5038294 modbus: cs-length: "Read 0 units of data"
+5034960-5042869 modbus: sc-data: "0x0003 / 3"
+5039535-5047445 modbus: cs-error: "CRC should be 80 108"
+5044111-5052020 modbus: sc-crc: "CRC correct"
+5048686-5052020 modbus: cs-error: "Unknown function"
+5214578-5217912 modbus: sc-server-id: "Slave ID: 247"
+5214578-5217912 modbus: cs-server-id: "Slave ID: 247"
+5219249-5222583 modbus: sc-function: "Function 3: Read Holding Registers"
+5219249-5222583 modbus: cs-function: "Function 3: Read Holding Registers"
+5223899-5227233 modbus: sc-length: "Byte count: 0"
+5223899-5231904 modbus: cs-address: "Start at address 0x0 / 30001"
+5228570-5236554 modbus: sc-error: "CRC should be 192 194"
+5233220-5241226 modbus: cs-length: "Read 15 units of data"
+5237892-5245876 modbus: sc-error: "Message too long"
+5242542-5250547 modbus: cs-crc: "CRC correct"
+5267744-5271078 modbus: sc-server-id: "Slave ID: 247"
+5267744-5271078 modbus: cs-server-id: "Slave ID: 247"
+5272320-5275654 modbus: sc-function: "Function 3: Read Holding Registers"
+5272320-5275654 modbus: cs-function: "Function 3: Read Holding Registers"
+5276895-5280229 modbus: sc-length: "Byte count: 30"
+5276895-5284805 modbus: cs-address: "Start at address 0x1E00 / 37681"
+5281471-5289380 modbus: sc-data: "0x0000 / 0"
+5286046-5293956 modbus: cs-length: "Read 0 units of data"
+5290622-5298532 modbus: sc-data: "0x0000 / 0"
+5295198-5303107 modbus: cs-error: "CRC should be 87 116"
+5299773-5307683 modbus: sc-data: "0x41B7 / 16823"
+5304349-5307683 modbus: cs-error: "Unknown function"
+5308924-5312258 modbus: cs-error: "Unknown function"
+5308924-5316834 modbus: sc-data: "0x82A4 / 33444"
+5313500-5316834 modbus: cs-error: "Unknown function"
+5318076-5321410 modbus: cs-error: "Unknown function"
+5318076-5325985 modbus: sc-data: "0x3E57 / 15959"
+5322651-5325985 modbus: cs-error: "Unknown function"
+5327227-5330561 modbus: cs-error: "Unknown function"
+5327227-5335136 modbus: sc-data: "0x9E9F / 40607"
+5331802-5335136 modbus: cs-error: "Unknown function"
+5336378-5339712 modbus: cs-error: "Unknown function"
+5336378-5344288 modbus: sc-data: "0x0000 / 0"
+5340954-5344288 modbus: cs-error: "Unknown function"
+5345529-5348863 modbus: cs-error: "Unknown function"
+5345529-5353439 modbus: sc-data: "0x0000 / 0"
+5350105-5353439 modbus: cs-error: "Unknown function"
+5354680-5358014 modbus: cs-error: "Unknown function"
+5354680-5362590 modbus: sc-data: "0x3AC3 / 15043"
+5359256-5362590 modbus: cs-error: "Unknown function"
+5363832-5367166 modbus: cs-error: "Unknown function"
+5363832-5371741 modbus: sc-data: "0x0FB5 / 4021"
+5368407-5371741 modbus: cs-error: "Unknown function"
+5372983-5376317 modbus: cs-error: "Unknown function"
+5372983-5380893 modbus: sc-data: "0x0000 / 0"
+5377559-5380893 modbus: cs-error: "Unknown function"
+5382134-5385468 modbus: cs-error: "Unknown function"
+5382134-5390044 modbus: sc-data: "0x0000 / 0"
+5386710-5390044 modbus: cs-error: "Unknown function"
+5391285-5394619 modbus: cs-error: "Unknown function"
+5391285-5399195 modbus: sc-data: "0x0000 / 0"
+5395861-5399195 modbus: cs-error: "Unknown function"
+5400437-5403771 modbus: cs-error: "Unknown function"
+5400437-5408346 modbus: sc-data: "0x0000 / 0"
+5405012-5408346 modbus: cs-error: "Unknown function"
+5409588-5412922 modbus: cs-error: "Unknown function"
+5409588-5417497 modbus: sc-data: "0x0000 / 0"
+5414163-5417497 modbus: cs-error: "Unknown function"
+5418739-5422073 modbus: cs-error: "Unknown function"
+5418739-5426649 modbus: sc-crc: "CRC correct"
+5423315-5426649 modbus: cs-error: "Unknown function"
+5583921-5587255 modbus: sc-server-id: "Slave ID: 247"
+5583921-5587255 modbus: cs-server-id: "Slave ID: 247"
+5588591-5591925 modbus: sc-function: "Function 3: Read Holding Registers"
+5588591-5591925 modbus: cs-function: "Function 3: Read Holding Registers"
+5593242-5596576 modbus: sc-length: "Byte count: 0"
+5593242-5601247 modbus: cs-address: "Start at address 0xD / 30014"
+5597913-5605897 modbus: sc-error: "CRC should be 192 194"
+5602563-5610569 modbus: cs-length: "Read 1 units of data"
+5607235-5615219 modbus: sc-error: "Message too long"
+5611885-5619890 modbus: cs-crc: "CRC correct"
+5636757-5640091 modbus: sc-server-id: "Slave ID: 247"
+5636757-5640091 modbus: cs-server-id: "Slave ID: 247"
+5641332-5644666 modbus: sc-function: "Function 3: Read Holding Registers"
+5641332-5644666 modbus: cs-function: "Function 3: Read Holding Registers"
+5645908-5649242 modbus: sc-length: "Byte count: 2"
+5645908-5653817 modbus: cs-address: "Start at address 0x200 / 30513"
+5650483-5658393 modbus: sc-data: "0x0000 / 0"
+5655059-5662969 modbus: cs-length: "Read 112 units of data"
+5659635-5667544 modbus: sc-crc: "CRC correct"
+5662969-5668795 modbus: cs-error: "Message too short or not finished"
+5832148-5835482 modbus: sc-server-id: "Slave ID: 247"
+5832148-5835482 modbus: cs-server-id: "Slave ID: 247"
+5836818-5840152 modbus: sc-function: "Function 3: Read Holding Registers"
+5836818-5840152 modbus: cs-function: "Function 3: Read Holding Registers"
+5841468-5844802 modbus: sc-length: "Byte count: 64"
+5841468-5849474 modbus: cs-address: "Start at address 0x4082 / 46515"
+5846140-5854124 modbus: sc-data: "0x8200 / 33280"
+5850790-5858795 modbus: cs-length: "Read 2 units of data"
+5855461-5863445 modbus: sc-data: "0x0265 / 613"
+5860111-5868117 modbus: cs-crc: "CRC correct"
+5863445-5869368 modbus: sc-error: "Message too short or not finished"
+5887063-5890397 modbus: sc-server-id: "Slave ID: 247"
+5887063-5890397 modbus: cs-server-id: "Slave ID: 247"
+5891639-5894973 modbus: sc-function: "Function 3: Read Holding Registers"
+5891639-5894973 modbus: cs-function: "Function 3: Read Holding Registers"
+5896214-5899548 modbus: sc-length: "Byte count: 4"
+5896214-5904124 modbus: cs-address: "Start at address 0x400 / 31025"
+5900790-5908700 modbus: sc-data: "0x0000 / 0"
+5905366-5913275 modbus: cs-length: "Read 0 units of data"
+5909941-5917851 modbus: sc-data: "0x0003 / 3"
+5914517-5922426 modbus: cs-error: "CRC should be 80 108"
+5919092-5927002 modbus: sc-crc: "CRC correct"
+5923668-5927002 modbus: cs-error: "Unknown function"
+6089525-6092859 modbus: sc-server-id: "Slave ID: 247"
+6089525-6092859 modbus: cs-server-id: "Slave ID: 247"
+6094196-6097530 modbus: sc-function: "Function 3: Read Holding Registers"
+6094196-6097530 modbus: cs-function: "Function 3: Read Holding Registers"
+6098846-6102180 modbus: sc-length: "Byte count: 0"
+6098846-6106851 modbus: cs-address: "Start at address 0x0 / 30001"
+6103517-6111501 modbus: sc-error: "CRC should be 192 194"
+6108167-6116173 modbus: cs-length: "Read 15 units of data"
+6112839-6120823 modbus: sc-error: "Message too long"
+6117489-6125494 modbus: cs-crc: "CRC correct"
+6142700-6146034 modbus: sc-server-id: "Slave ID: 247"
+6142700-6146034 modbus: cs-server-id: "Slave ID: 247"
+6147275-6150609 modbus: sc-function: "Function 3: Read Holding Registers"
+6147275-6150609 modbus: cs-function: "Function 3: Read Holding Registers"
+6151851-6155185 modbus: sc-length: "Byte count: 30"
+6151851-6159760 modbus: cs-address: "Start at address 0x1E00 / 37681"
+6156426-6164336 modbus: sc-data: "0x0000 / 0"
+6161002-6168912 modbus: cs-length: "Read 0 units of data"
+6165578-6173487 modbus: sc-data: "0x0000 / 0"
+6170153-6178063 modbus: cs-error: "CRC should be 87 116"
+6174729-6182638 modbus: sc-data: "0x41B7 / 16823"
+6179304-6182638 modbus: cs-error: "Unknown function"
+6183880-6187214 modbus: cs-error: "Unknown function"
+6183880-6191790 modbus: sc-data: "0x82A4 / 33444"
+6188456-6191790 modbus: cs-error: "Unknown function"
+6193031-6196365 modbus: cs-error: "Unknown function"
+6193031-6200941 modbus: sc-data: "0x3E57 / 15959"
+6197607-6200941 modbus: cs-error: "Unknown function"
+6202182-6205516 modbus: cs-error: "Unknown function"
+6202182-6210092 modbus: sc-data: "0x9E9F / 40607"
+6206758-6210092 modbus: cs-error: "Unknown function"
+6211334-6214668 modbus: cs-error: "Unknown function"
+6211334-6219243 modbus: sc-data: "0x0000 / 0"
+6215909-6219243 modbus: cs-error: "Unknown function"
+6220485-6223819 modbus: cs-error: "Unknown function"
+6220485-6228394 modbus: sc-data: "0x0000 / 0"
+6225060-6228394 modbus: cs-error: "Unknown function"
+6229636-6232970 modbus: cs-error: "Unknown function"
+6229636-6237546 modbus: sc-data: "0x3C5B / 15451"
+6234212-6237546 modbus: cs-error: "Unknown function"
+6238787-6242121 modbus: cs-error: "Unknown function"
+6238787-6246697 modbus: sc-data: "0x71AC / 29100"
+6243363-6246697 modbus: cs-error: "Unknown function"
+6247939-6251273 modbus: cs-error: "Unknown function"
+6247939-6255848 modbus: sc-data: "0x0000 / 0"
+6252514-6255848 modbus: cs-error: "Unknown function"
+6257090-6260424 modbus: cs-error: "Unknown function"
+6257090-6264999 modbus: sc-data: "0x0000 / 0"
+6261665-6264999 modbus: cs-error: "Unknown function"
+6266241-6269575 modbus: cs-error: "Unknown function"
+6266241-6274151 modbus: sc-data: "0x0000 / 0"
+6270817-6274151 modbus: cs-error: "Unknown function"
+6275392-6278726 modbus: cs-error: "Unknown function"
+6275392-6283302 modbus: sc-data: "0x0000 / 0"
+6279968-6283302 modbus: cs-error: "Unknown function"
+6284543-6287877 modbus: cs-error: "Unknown function"
+6284543-6292453 modbus: sc-data: "0x0000 / 0"
+6289119-6292453 modbus: cs-error: "Unknown function"
+6293695-6297029 modbus: cs-error: "Unknown function"
+6293695-6301604 modbus: sc-crc: "CRC correct"
+6298270-6301604 modbus: cs-error: "Unknown function"
+6395665-6398999 modbus: sc-server-id: "Slave ID: 247"
+6395665-6398999 modbus: cs-server-id: "Slave ID: 247"
+6400335-6403669 modbus: sc-function: "Function 3: Read Holding Registers"
+6400335-6403669 modbus: cs-function: "Function 3: Read Holding Registers"
+6404985-6408319 modbus: sc-length: "Byte count: 0"
+6404985-6412991 modbus: cs-address: "Start at address 0xD / 30014"
+6409657-6417641 modbus: sc-error: "CRC should be 192 194"
+6414307-6422313 modbus: cs-length: "Read 1 units of data"
+6418979-6426963 modbus: sc-error: "Message too long"
+6423629-6431634 modbus: cs-crc: "CRC correct"
+6448486-6451820 modbus: sc-server-id: "Slave ID: 247"
+6448486-6451820 modbus: cs-server-id: "Slave ID: 247"
+6453061-6456395 modbus: sc-function: "Function 3: Read Holding Registers"
+6453061-6456395 modbus: cs-function: "Function 3: Read Holding Registers"
+6457637-6460971 modbus: sc-length: "Byte count: 2"
+6457637-6465546 modbus: cs-address: "Start at address 0x200 / 30513"
+6462212-6470122 modbus: sc-data: "0x0000 / 0"
+6466788-6474698 modbus: cs-length: "Read 112 units of data"
+6471364-6479273 modbus: sc-crc: "CRC correct"
+6474698-6480524 modbus: cs-error: "Message too short or not finished"
+6644489-6647823 modbus: sc-server-id: "Slave ID: 247"
+6644489-6647823 modbus: cs-server-id: "Slave ID: 247"
+6649159-6652493 modbus: sc-function: "Function 3: Read Holding Registers"
+6649159-6652493 modbus: cs-function: "Function 3: Read Holding Registers"
+6653809-6657143 modbus: sc-length: "Byte count: 64"
+6653809-6661815 modbus: cs-address: "Start at address 0x4082 / 46515"
+6658481-6666465 modbus: sc-data: "0x8200 / 33280"
+6663131-6671137 modbus: cs-length: "Read 2 units of data"
+6667803-6675786 modbus: sc-data: "0x0265 / 613"
+6672452-6680458 modbus: cs-crc: "CRC correct"
+6675786-6681709 modbus: sc-error: "Message too short or not finished"
+6699390-6702724 modbus: sc-server-id: "Slave ID: 247"
+6699390-6702724 modbus: cs-server-id: "Slave ID: 247"
+6703966-6707300 modbus: sc-function: "Function 3: Read Holding Registers"
+6703966-6707300 modbus: cs-function: "Function 3: Read Holding Registers"
+6708541-6711875 modbus: sc-length: "Byte count: 4"
+6708541-6716451 modbus: cs-address: "Start at address 0x400 / 31025"
+6713117-6721027 modbus: sc-data: "0x0000 / 0"
+6717693-6725602 modbus: cs-length: "Read 0 units of data"
+6722268-6730178 modbus: sc-data: "0x0003 / 3"
+6726844-6734753 modbus: cs-error: "CRC should be 80 108"
+6731419-6739329 modbus: sc-crc: "CRC correct"
+6735995-6739329 modbus: cs-error: "Unknown function"
+7052270-7055604 modbus: sc-server-id: "Slave ID: 247"
+7052270-7055604 modbus: cs-server-id: "Slave ID: 247"
+7056940-7060274 modbus: sc-function: "Function 16: Write Multiple Registers"
+7056940-7060274 modbus: cs-function: "Function 16: Write Multiple Registers"
+7061591-7069596 modbus: sc-address: "Start at address 0x6 / 30007"
+7061591-7069596 modbus: cs-address: "Start at address 0x6 / 30007"
+7070912-7078918 modbus: sc-data: "Write 2 Registers"
+7070912-7078918 modbus: cs-length: "Write 2 Registers"
+7080234-7083568 modbus: cs-length: "Byte count: 4"
+7080234-7088239 modbus: sc-error: "CRC should be 181 95"
+7084905-7088239 modbus: cs-data: "Value 0x41"
+7089555-7092889 modbus: sc-error: "Message too long"
+7089555-7092889 modbus: cs-data: "Value 0xA0"
+7094227-7097561 modbus: sc-error: "Message too long"
+7094227-7097561 modbus: cs-data: "Value 0x0"
+7098877-7102211 modbus: sc-error: "Message too long"
+7098877-7102211 modbus: cs-data: "Value 0x0"
+7103548-7106882 modbus: sc-error: "Message too long"
+7108198-7111532 modbus: sc-error: "Message too long"
+7103548-7111532 modbus: cs-crc: "CRC correct"
+7128484-7131818 modbus: sc-server-id: "Slave ID: 247"
+7128484-7131818 modbus: cs-server-id: "Slave ID: 247"
+7133059-7136393 modbus: sc-function: "Function 16: Write Multiple Registers"
+7133059-7136393 modbus: cs-function: "Function 16: Write Multiple Registers"
+7137635-7145545 modbus: sc-address: "Start at address 0x6 / 30007"
+7137635-7145545 modbus: cs-address: "Start at address 0x6 / 30007"
+7146786-7154696 modbus: sc-data: "Write 2 Registers"
+7146786-7154696 modbus: cs-length: "Write 2 Registers"
+7155937-7159271 modbus: cs-error: "Bad byte count, is 181, should be 4"
+7155937-7163847 modbus: sc-crc: "CRC correct"
+7160513-7163847 modbus: cs-data: "Value 0x5F"
+7707681-7711015 modbus: sc-server-id: "Slave ID: 247"
+7707681-7711015 modbus: cs-server-id: "Slave ID: 247"
+7712329-7715663 modbus: sc-function: "Function 3: Read Holding Registers"
+7712329-7715663 modbus: cs-function: "Function 3: Read Holding Registers"
+7717001-7720335 modbus: sc-length: "Byte count: 0"
+7717001-7724985 modbus: cs-address: "Start at address 0x0 / 30001"
+7721651-7729656 modbus: sc-error: "CRC should be 192 194"
+7726322-7734307 modbus: cs-length: "Read 15 units of data"
+7730973-7738978 modbus: sc-error: "Message too long"
+7735644-7743628 modbus: cs-crc: "CRC correct"
+7760828-7764162 modbus: sc-server-id: "Slave ID: 247"
+7760828-7764162 modbus: cs-server-id: "Slave ID: 247"
+7765404-7768738 modbus: sc-function: "Function 3: Read Holding Registers"
+7765404-7768738 modbus: cs-function: "Function 3: Read Holding Registers"
+7769979-7773313 modbus: sc-length: "Byte count: 30"
+7769979-7777889 modbus: cs-address: "Start at address 0x1E00 / 37681"
+7774555-7782464 modbus: sc-data: "0x0000 / 0"
+7779130-7787040 modbus: cs-length: "Read 0 units of data"
+7783706-7791616 modbus: sc-data: "0x0000 / 0"
+7788282-7796191 modbus: cs-error: "CRC should be 87 116"
+7792857-7800767 modbus: sc-data: "0x41B7 / 16823"
+7797433-7800767 modbus: cs-error: "Unknown function"
+7802008-7805342 modbus: cs-error: "Unknown function"
+7802008-7809918 modbus: sc-data: "0x82A4 / 33444"
+7806584-7809918 modbus: cs-error: "Unknown function"
+7811160-7814494 modbus: cs-error: "Unknown function"
+7811160-7819069 modbus: sc-data: "0x3E57 / 15959"
+7815735-7819069 modbus: cs-error: "Unknown function"
+7820311-7823645 modbus: cs-error: "Unknown function"
+7820311-7828221 modbus: sc-data: "0x9E9F / 40607"
+7824887-7828221 modbus: cs-error: "Unknown function"
+7829462-7832796 modbus: cs-error: "Unknown function"
+7829462-7837372 modbus: sc-data: "0x41A0 / 16800"
+7834038-7837372 modbus: cs-error: "Unknown function"
+7838613-7841947 modbus: cs-error: "Unknown function"
+7838613-7846523 modbus: sc-data: "0x0000 / 0"
+7843189-7846523 modbus: cs-error: "Unknown function"
+7847765-7851099 modbus: cs-error: "Unknown function"
+7847765-7855674 modbus: sc-data: "0x0000 / 0"
+7852340-7855674 modbus: cs-error: "Unknown function"
+7856916-7860250 modbus: cs-error: "Unknown function"
+7856916-7864825 modbus: sc-data: "0x0000 / 0"
+7861491-7864825 modbus: cs-error: "Unknown function"
+7866067-7869401 modbus: cs-error: "Unknown function"
+7866067-7873977 modbus: sc-data: "0x4225 / 16933"
+7870643-7873977 modbus: cs-error: "Unknown function"
+7875218-7878552 modbus: cs-error: "Unknown function"
+7875218-7883128 modbus: sc-data: "0x4E1E / 19998"
+7879794-7883128 modbus: cs-error: "Unknown function"
+7884369-7887703 modbus: cs-error: "Unknown function"
+7884369-7892279 modbus: sc-data: "0x0000 / 0"
+7888945-7892279 modbus: cs-error: "Unknown function"
+7893521-7896855 modbus: cs-error: "Unknown function"
+7893521-7901430 modbus: sc-data: "0x0000 / 0"
+7898096-7901430 modbus: cs-error: "Unknown function"
+7902672-7906006 modbus: cs-error: "Unknown function"
+7902672-7910581 modbus: sc-data: "0x0000 / 0"
+7907247-7910581 modbus: cs-error: "Unknown function"
+7911823-7915157 modbus: cs-error: "Unknown function"
+7911823-7919733 modbus: sc-crc: "CRC correct"
+7916399-7919733 modbus: cs-error: "Unknown function"
+8021691-8025025 modbus: sc-server-id: "Slave ID: 247"
+8021691-8025025 modbus: cs-server-id: "Slave ID: 247"
+8026340-8029674 modbus: sc-function: "Function 3: Read Holding Registers"
+8026340-8029674 modbus: cs-function: "Function 3: Read Holding Registers"
+8031012-8034346 modbus: sc-length: "Byte count: 0"
+8031012-8038996 modbus: cs-address: "Start at address 0xD / 30014"
+8035662-8043667 modbus: sc-error: "CRC should be 192 194"
+8040333-8048317 modbus: cs-length: "Read 1 units of data"
+8044983-8052989 modbus: sc-error: "Message too long"
+8049655-8057639 modbus: cs-crc: "CRC correct"
+8074491-8077825 modbus: sc-server-id: "Slave ID: 247"
+8074491-8077825 modbus: cs-server-id: "Slave ID: 247"
+8079067-8082401 modbus: sc-function: "Function 3: Read Holding Registers"
+8079067-8082401 modbus: cs-function: "Function 3: Read Holding Registers"
+8083642-8086976 modbus: sc-length: "Byte count: 2"
+8083642-8091552 modbus: cs-address: "Start at address 0x200 / 30513"
+8088218-8096128 modbus: sc-data: "0x0000 / 0"
+8092794-8100703 modbus: cs-length: "Read 112 units of data"
+8097369-8105279 modbus: sc-crc: "CRC correct"
+8100703-8106530 modbus: cs-error: "Message too short or not finished"
+8269555-8272889 modbus: sc-server-id: "Slave ID: 247"
+8269555-8272889 modbus: cs-server-id: "Slave ID: 247"
+8274204-8277538 modbus: sc-function: "Function 3: Read Holding Registers"
+8274204-8277538 modbus: cs-function: "Function 3: Read Holding Registers"
+8278876-8282210 modbus: sc-length: "Byte count: 64"
+8278876-8286860 modbus: cs-address: "Start at address 0x4082 / 46515"
+8283526-8291531 modbus: sc-data: "0x8200 / 33280"
+8288197-8296181 modbus: cs-length: "Read 2 units of data"
+8292847-8300853 modbus: sc-data: "0x0265 / 613"
+8297519-8305503 modbus: cs-crc: "CRC correct"
+8300853-8306754 modbus: sc-error: "Message too short or not finished"
+8324433-8327767 modbus: sc-server-id: "Slave ID: 247"
+8324433-8327767 modbus: cs-server-id: "Slave ID: 247"
+8329010-8332344 modbus: sc-function: "Function 3: Read Holding Registers"
+8329010-8332344 modbus: cs-function: "Function 3: Read Holding Registers"
+8333585-8336919 modbus: sc-length: "Byte count: 4"
+8333585-8341495 modbus: cs-address: "Start at address 0x400 / 31025"
+8338161-8346070 modbus: sc-data: "0x0000 / 0"
+8342736-8350646 modbus: cs-length: "Read 0 units of data"
+8347312-8355222 modbus: sc-data: "0x0003 / 3"
+8351888-8359797 modbus: cs-error: "CRC should be 80 108"
+8356463-8364373 modbus: sc-crc: "CRC correct"
+8361039-8364373 modbus: cs-error: "Unknown function"
+8529663-8532997 modbus: sc-server-id: "Slave ID: 247"
+8529663-8532997 modbus: cs-server-id: "Slave ID: 247"
+8534312-8537646 modbus: sc-function: "Function 3: Read Holding Registers"
+8534312-8537646 modbus: cs-function: "Function 3: Read Holding Registers"
+8538983-8542317 modbus: sc-length: "Byte count: 0"
+8538983-8546968 modbus: cs-address: "Start at address 0x0 / 30001"
+8543634-8551639 modbus: sc-error: "CRC should be 192 194"
+8548305-8556289 modbus: cs-length: "Read 15 units of data"
+8552955-8560961 modbus: sc-error: "Message too long"
+8557627-8565611 modbus: cs-crc: "CRC correct"
+8584594-8587928 modbus: sc-server-id: "Slave ID: 247"
+8584594-8587928 modbus: cs-server-id: "Slave ID: 247"
+8589170-8592504 modbus: sc-function: "Function 3: Read Holding Registers"
+8589170-8592504 modbus: cs-function: "Function 3: Read Holding Registers"
+8593745-8597079 modbus: sc-length: "Byte count: 30"
+8593745-8601655 modbus: cs-address: "Start at address 0x1E00 / 37681"
+8598321-8606230 modbus: sc-data: "0x0000 / 0"
+8602896-8610806 modbus: cs-length: "Read 0 units of data"
+8607472-8615382 modbus: sc-data: "0x0000 / 0"
+8612048-8619957 modbus: cs-error: "CRC should be 87 116"
+8616623-8624533 modbus: sc-data: "0x41B7 / 16823"
+8621199-8624533 modbus: cs-error: "Unknown function"
+8625774-8629108 modbus: cs-error: "Unknown function"
+8625774-8633684 modbus: sc-data: "0x82A4 / 33444"
+8630350-8633684 modbus: cs-error: "Unknown function"
+8634926-8638260 modbus: cs-error: "Unknown function"
+8634926-8642835 modbus: sc-data: "0x3E57 / 15959"
+8639501-8642835 modbus: cs-error: "Unknown function"
+8644077-8647411 modbus: cs-error: "Unknown function"
+8644077-8651986 modbus: sc-data: "0x9E9F / 40607"
+8648652-8651986 modbus: cs-error: "Unknown function"
+8653228-8656562 modbus: cs-error: "Unknown function"
+8653228-8661138 modbus: sc-data: "0x41A0 / 16800"
+8657804-8661138 modbus: cs-error: "Unknown function"
+8662379-8665713 modbus: cs-error: "Unknown function"
+8662379-8670289 modbus: sc-data: "0x0000 / 0"
+8666955-8670289 modbus: cs-error: "Unknown function"
+8671530-8674864 modbus: cs-error: "Unknown function"
+8671530-8679440 modbus: sc-data: "0x3AC3 / 15043"
+8676106-8679440 modbus: cs-error: "Unknown function"
+8680682-8684016 modbus: cs-error: "Unknown function"
+8680682-8688591 modbus: sc-data: "0x0FB5 / 4021"
+8685257-8688591 modbus: cs-error: "Unknown function"
+8689833-8693167 modbus: cs-error: "Unknown function"
+8689833-8697743 modbus: sc-data: "0x4259 / 16985"
+8694409-8697743 modbus: cs-error: "Unknown function"
+8698984-8702318 modbus: cs-error: "Unknown function"
+8698984-8706894 modbus: sc-data: "0xC1DA / 49626"
+8703560-8706894 modbus: cs-error: "Unknown function"
+8708135-8711469 modbus: cs-error: "Unknown function"
+8708135-8716045 modbus: sc-data: "0x0000 / 0"
+8712711-8716045 modbus: cs-error: "Unknown function"
+8717287-8720621 modbus: cs-error: "Unknown function"
+8717287-8725196 modbus: sc-data: "0x0000 / 0"
+8721862-8725196 modbus: cs-error: "Unknown function"
+8726438-8729772 modbus: cs-error: "Unknown function"
+8726438-8734347 modbus: sc-data: "0x0000 / 0"
+8731013-8734347 modbus: cs-error: "Unknown function"
+8735589-8738923 modbus: cs-error: "Unknown function"
+8735589-8743499 modbus: sc-crc: "CRC correct"
+8740165-8743499 modbus: cs-error: "Unknown function"
+8833329-8836663 modbus: sc-server-id: "Slave ID: 247"
+8833329-8836663 modbus: cs-server-id: "Slave ID: 247"
+8837977-8841311 modbus: sc-function: "Function 3: Read Holding Registers"
+8837977-8841311 modbus: cs-function: "Function 3: Read Holding Registers"
+8842649-8845983 modbus: sc-length: "Byte count: 0"
+8842649-8850633 modbus: cs-address: "Start at address 0xD / 30014"
+8847299-8855304 modbus: sc-error: "CRC should be 192 194"
+8851970-8859955 modbus: cs-length: "Read 1 units of data"
+8856621-8864626 modbus: sc-error: "Message too long"
+8861292-8869276 modbus: cs-crc: "CRC correct"
+8886142-8889476 modbus: sc-server-id: "Slave ID: 247"
+8886142-8889476 modbus: cs-server-id: "Slave ID: 247"
+8890718-8894052 modbus: sc-function: "Function 3: Read Holding Registers"
+8890718-8894052 modbus: cs-function: "Function 3: Read Holding Registers"
+8895293-8898627 modbus: sc-length: "Byte count: 2"
+8895293-8903203 modbus: cs-address: "Start at address 0x200 / 30513"
+8899869-8907779 modbus: sc-data: "0x0000 / 0"
+8904445-8912354 modbus: cs-length: "Read 112 units of data"
+8909020-8916930 modbus: sc-crc: "CRC correct"
+8912354-8918181 modbus: cs-error: "Message too short or not finished"
+9081448-9084782 modbus: sc-server-id: "Slave ID: 247"
+9081448-9084782 modbus: cs-server-id: "Slave ID: 247"
+9086097-9089431 modbus: sc-function: "Function 3: Read Holding Registers"
+9086097-9089431 modbus: cs-function: "Function 3: Read Holding Registers"
+9090769-9094103 modbus: sc-length: "Byte count: 64"
+9090769-9098753 modbus: cs-address: "Start at address 0x4082 / 46515"
+9095419-9103424 modbus: sc-data: "0x8200 / 33280"
+9100090-9108074 modbus: cs-length: "Read 2 units of data"
+9104740-9112746 modbus: sc-data: "0x0265 / 613"
+9109412-9117396 modbus: cs-crc: "CRC correct"
+9112746-9118647 modbus: sc-error: "Message too short or not finished"
+9136345-9139679 modbus: sc-server-id: "Slave ID: 247"
+9136345-9139679 modbus: cs-server-id: "Slave ID: 247"
+9140921-9144255 modbus: sc-function: "Function 3: Read Holding Registers"
+9140921-9144255 modbus: cs-function: "Function 3: Read Holding Registers"
+9145496-9148830 modbus: sc-length: "Byte count: 4"
+9145496-9153406 modbus: cs-address: "Start at address 0x400 / 31025"
+9150072-9157981 modbus: sc-data: "0x0000 / 0"
+9154647-9162557 modbus: cs-length: "Read 0 units of data"
+9159223-9167133 modbus: sc-data: "0x0003 / 3"
+9163799-9171708 modbus: cs-error: "CRC should be 80 108"
+9168374-9176284 modbus: sc-crc: "CRC correct"
+9172950-9176284 modbus: cs-error: "Unknown function"
+9339935-9343269 modbus: sc-server-id: "Slave ID: 247"
+9339935-9343269 modbus: cs-server-id: "Slave ID: 247"
+9344584-9347918 modbus: sc-function: "Function 3: Read Holding Registers"
+9344584-9347918 modbus: cs-function: "Function 3: Read Holding Registers"
+9349256-9352590 modbus: sc-length: "Byte count: 0"
+9349256-9357240 modbus: cs-address: "Start at address 0x0 / 30001"
+9353906-9361911 modbus: sc-error: "CRC should be 192 194"
+9358577-9366561 modbus: cs-length: "Read 15 units of data"
+9363227-9371233 modbus: sc-error: "Message too long"
+9367899-9375883 modbus: cs-crc: "CRC correct"
+9393073-9396407 modbus: sc-server-id: "Slave ID: 247"
+9393073-9396407 modbus: cs-server-id: "Slave ID: 247"
+9397649-9400983 modbus: sc-function: "Function 3: Read Holding Registers"
+9397649-9400983 modbus: cs-function: "Function 3: Read Holding Registers"
+9402224-9405558 modbus: sc-length: "Byte count: 30"
+9402224-9410134 modbus: cs-address: "Start at address 0x1E00 / 37681"
+9406800-9414710 modbus: sc-data: "0x0000 / 0"
+9411376-9419285 modbus: cs-length: "Read 0 units of data"
+9415951-9423861 modbus: sc-data: "0x0000 / 0"
+9420527-9428436 modbus: cs-error: "CRC should be 87 116"
+9425102-9433012 modbus: sc-data: "0x41B7 / 16823"
+9429678-9433012 modbus: cs-error: "Unknown function"
+9434254-9437588 modbus: cs-error: "Unknown function"
+9434254-9442163 modbus: sc-data: "0x82A4 / 33444"
+9438829-9442163 modbus: cs-error: "Unknown function"
+9443405-9446739 modbus: cs-error: "Unknown function"
+9443405-9451314 modbus: sc-data: "0x3E57 / 15959"
+9447980-9451314 modbus: cs-error: "Unknown function"
+9452556-9455890 modbus: cs-error: "Unknown function"
+9452556-9460466 modbus: sc-data: "0x9E9F / 40607"
+9457132-9460466 modbus: cs-error: "Unknown function"
+9461707-9465041 modbus: cs-error: "Unknown function"
+9461707-9469617 modbus: sc-data: "0x41A0 / 16800"
+9466283-9469617 modbus: cs-error: "Unknown function"
+9470859-9474193 modbus: cs-error: "Unknown function"
+9470859-9478768 modbus: sc-data: "0x0000 / 0"
+9475434-9478768 modbus: cs-error: "Unknown function"
+9480010-9483344 modbus: cs-error: "Unknown function"
+9480010-9487919 modbus: sc-data: "0x3C5B / 15451"
+9484585-9487919 modbus: cs-error: "Unknown function"
+9489161-9492495 modbus: cs-error: "Unknown function"
+9489161-9497071 modbus: sc-data: "0x71AC / 29100"
+9493737-9497071 modbus: cs-error: "Unknown function"
+9498312-9501646 modbus: cs-error: "Unknown function"
+9498312-9506222 modbus: sc-data: "0x4284 / 17028"
+9502888-9506222 modbus: cs-error: "Unknown function"
+9507463-9510797 modbus: cs-error: "Unknown function"
+9507463-9515373 modbus: sc-data: "0xB871 / 47217"
+9512039-9515373 modbus: cs-error: "Unknown function"
+9516615-9519949 modbus: cs-error: "Unknown function"
+9516615-9524524 modbus: sc-data: "0x0000 / 0"
+9521190-9524524 modbus: cs-error: "Unknown function"
+9525766-9529100 modbus: cs-error: "Unknown function"
+9525766-9533675 modbus: sc-data: "0x0000 / 0"
+9530341-9533675 modbus: cs-error: "Unknown function"
+9534917-9538251 modbus: cs-error: "Unknown function"
+9534917-9542827 modbus: sc-data: "0x0000 / 0"
+9539493-9542827 modbus: cs-error: "Unknown function"
+9544068-9547402 modbus: cs-error: "Unknown function"
+9544068-9551978 modbus: sc-crc: "CRC correct"
+9548644-9551978 modbus: cs-error: "Unknown function"
index 2dfda15bcdc79329dab8c706e9474be847ba8778..3949895f5e5267ce0d238ca43b7431ab703be732 100644 (file)
@@ -4,3 +4,38 @@ test brainchild_io_16do
        stack uart modbus
        input uart/modbus_rtu/brainchild_io_16do/brainchild-io-16do.sr
        output modbus annotation match brainchild_io_16do.output
+
+test flowmeter_graph_tool
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr
+       output modbus annotation match flowmeter_graph_tool.output
+
+test flowmeter_target0_val0
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr
+       output modbus annotation match flowmeter_graph_tool.output
+
+test flowmeter_target_0liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_0liter_per_min.sr
+       output modbus annotation match flowmeter_target_0liter_per_min.output
+
+test flowmeter_target_15liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_15liter_per_min.sr
+       output modbus annotation match flowmeter_target_15liter_per_min.output
+
+test flowmeter_target_20liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_20liter_per_min.sr
+       output modbus annotation match flowmeter_target_20liter_per_min.output