]> sigrok.org Git - sigrok-test.git/blob - decoder/test/modbus/flowmeter_graph_tool.output
modbus: Add a few flowmeter test-cases.
[sigrok-test.git] / decoder / test / modbus / flowmeter_graph_tool.output
1 16632-19966 modbus: sc-server-id: "Slave ID: 247"
2 16632-19966 modbus: cs-server-id: "Slave ID: 247"
3 21303-24637 modbus: sc-function: "Function 3: Read Holding Registers"
4 21303-24637 modbus: cs-function: "Function 3: Read Holding Registers"
5 25953-29287 modbus: sc-length: "Byte count: 0"
6 25953-33958 modbus: cs-address: "Start at address 0x0 / 30001"
7 30624-38608 modbus: sc-error: "CRC should be 192 194"
8 35274-43280 modbus: cs-length: "Read 2 units of data"
9 39946-47930 modbus: sc-error: "Message too long"
10 44596-52601 modbus: cs-crc: "CRC correct"
11 69493-72827 modbus: sc-server-id: "Slave ID: 247"
12 69493-72827 modbus: cs-server-id: "Slave ID: 247"
13 74068-77402 modbus: sc-function: "Function 3: Read Holding Registers"
14 74068-77402 modbus: cs-function: "Function 3: Read Holding Registers"
15 78644-81978 modbus: sc-length: "Byte count: 4"
16 78644-86553 modbus: cs-address: "Start at address 0x400 / 31025"
17 83219-91129 modbus: sc-data: "0x0000 / 0"
18 87795-95705 modbus: cs-length: "Read 0 units of data"
19 92371-100280 modbus: sc-data: "0x0000 / 0"
20 96946-104856 modbus: cs-error: "CRC should be 80 108"
21 101522-109431 modbus: sc-crc: "CRC correct"
22 106097-109431 modbus: cs-error: "Unknown function"
23 266032-269366 modbus: sc-server-id: "Slave ID: 247"
24 266032-269366 modbus: cs-server-id: "Slave ID: 247"
25 270702-274036 modbus: sc-function: "Function 3: Read Holding Registers"
26 270702-274036 modbus: cs-function: "Function 3: Read Holding Registers"
27 275352-278686 modbus: sc-length: "Byte count: 0"
28 275352-283358 modbus: cs-address: "Start at address 0x6 / 30007"
29 280024-288008 modbus: sc-error: "CRC should be 192 194"
30 284674-292679 modbus: cs-length: "Read 2 units of data"
31 289345-297329 modbus: sc-error: "Message too long"
32 293995-302001 modbus: cs-crc: "CRC correct"
33 318889-322223 modbus: sc-server-id: "Slave ID: 247"
34 318889-322223 modbus: cs-server-id: "Slave ID: 247"
35 323465-326799 modbus: sc-function: "Function 3: Read Holding Registers"
36 323465-326799 modbus: cs-function: "Function 3: Read Holding Registers"
37 328041-331375 modbus: sc-length: "Byte count: 4"
38 328041-335950 modbus: cs-address: "Start at address 0x400 / 31025"
39 332616-340526 modbus: sc-data: "0x0000 / 0"
40 337192-345101 modbus: cs-length: "Read 0 units of data"
41 341767-349677 modbus: sc-data: "0x0000 / 0"
42 346343-354253 modbus: cs-error: "CRC should be 80 108"
43 350919-358828 modbus: sc-crc: "CRC correct"
44 355494-358828 modbus: cs-error: "Unknown function"
45 516264-519598 modbus: sc-server-id: "Slave ID: 247"
46 516264-519598 modbus: cs-server-id: "Slave ID: 247"
47 520934-524268 modbus: sc-function: "Function 3: Read Holding Registers"
48 520934-524268 modbus: cs-function: "Function 3: Read Holding Registers"
49 525584-528918 modbus: sc-length: "Byte count: 0"
50 525584-533589 modbus: cs-address: "Start at address 0xA / 30011"
51 530255-538239 modbus: sc-error: "CRC should be 192 194"
52 534905-542911 modbus: cs-length: "Read 2 units of data"
53 539577-547561 modbus: sc-error: "Message too long"
54 544227-552232 modbus: cs-crc: "CRC correct"
55 569118-572452 modbus: sc-server-id: "Slave ID: 247"
56 569118-572452 modbus: cs-server-id: "Slave ID: 247"
57 573694-577028 modbus: sc-function: "Function 3: Read Holding Registers"
58 573694-577028 modbus: cs-function: "Function 3: Read Holding Registers"
59 578269-581603 modbus: sc-length: "Byte count: 4"
60 578269-586179 modbus: cs-address: "Start at address 0x400 / 31025"
61 582845-590755 modbus: sc-data: "0x0000 / 0"
62 587421-595330 modbus: cs-length: "Read 0 units of data"
63 591996-599906 modbus: sc-data: "0x0000 / 0"
64 596572-604481 modbus: cs-error: "CRC should be 80 108"
65 601147-609057 modbus: sc-crc: "CRC correct"
66 605723-609057 modbus: cs-error: "Unknown function"
67 954633-957967 modbus: sc-server-id: "Slave ID: 247"
68 954633-957967 modbus: cs-server-id: "Slave ID: 247"
69 959303-962637 modbus: sc-function: "Function 3: Read Holding Registers"
70 959303-962637 modbus: cs-function: "Function 3: Read Holding Registers"
71 963953-967287 modbus: sc-length: "Byte count: 0"
72 963953-971959 modbus: cs-address: "Start at address 0x0 / 30001"
73 968625-976609 modbus: sc-error: "CRC should be 192 194"
74 973275-981280 modbus: cs-length: "Read 2 units of data"
75 977946-985930 modbus: sc-error: "Message too long"
76 982596-990602 modbus: cs-crc: "CRC correct"
77 1007493-1010827 modbus: sc-server-id: "Slave ID: 247"
78 1007493-1010827 modbus: cs-server-id: "Slave ID: 247"
79 1012069-1015403 modbus: sc-function: "Function 3: Read Holding Registers"
80 1012069-1015403 modbus: cs-function: "Function 3: Read Holding Registers"
81 1016644-1019978 modbus: sc-length: "Byte count: 4"
82 1016644-1024554 modbus: cs-address: "Start at address 0x400 / 31025"
83 1021220-1029129 modbus: sc-data: "0x0000 / 0"
84 1025795-1033705 modbus: cs-length: "Read 0 units of data"
85 1030371-1038281 modbus: sc-data: "0x0000 / 0"
86 1034947-1042856 modbus: cs-error: "CRC should be 80 108"
87 1039522-1047432 modbus: sc-crc: "CRC correct"
88 1044098-1047432 modbus: cs-error: "Unknown function"
89 1203307-1206641 modbus: sc-server-id: "Slave ID: 247"
90 1203307-1206641 modbus: cs-server-id: "Slave ID: 247"
91 1207977-1211311 modbus: sc-function: "Function 3: Read Holding Registers"
92 1207977-1211311 modbus: cs-function: "Function 3: Read Holding Registers"
93 1212627-1215961 modbus: sc-length: "Byte count: 0"
94 1212627-1220633 modbus: cs-address: "Start at address 0x6 / 30007"
95 1217299-1225283 modbus: sc-error: "CRC should be 192 194"
96 1221949-1229955 modbus: cs-length: "Read 2 units of data"
97 1226621-1234605 modbus: sc-error: "Message too long"
98 1231271-1239276 modbus: cs-crc: "CRC correct"
99 1256162-1259496 modbus: sc-server-id: "Slave ID: 247"
100 1256162-1259496 modbus: cs-server-id: "Slave ID: 247"
101 1260737-1264071 modbus: sc-function: "Function 3: Read Holding Registers"
102 1260737-1264071 modbus: cs-function: "Function 3: Read Holding Registers"
103 1265313-1268647 modbus: sc-length: "Byte count: 4"
104 1265313-1273223 modbus: cs-address: "Start at address 0x400 / 31025"
105 1269889-1277798 modbus: sc-data: "0x0000 / 0"
106 1274464-1282374 modbus: cs-length: "Read 0 units of data"
107 1279040-1286949 modbus: sc-data: "0x0000 / 0"
108 1283615-1291525 modbus: cs-error: "CRC should be 80 108"
109 1288191-1296101 modbus: sc-crc: "CRC correct"
110 1292767-1296101 modbus: cs-error: "Unknown function"
111 1453880-1457214 modbus: sc-server-id: "Slave ID: 247"
112 1453880-1457214 modbus: cs-server-id: "Slave ID: 247"
113 1458550-1461884 modbus: sc-function: "Function 3: Read Holding Registers"
114 1458550-1461884 modbus: cs-function: "Function 3: Read Holding Registers"
115 1463200-1466534 modbus: sc-length: "Byte count: 0"
116 1463200-1471206 modbus: cs-address: "Start at address 0xA / 30011"
117 1467872-1475856 modbus: sc-error: "CRC should be 192 194"
118 1472522-1480527 modbus: cs-length: "Read 2 units of data"
119 1477193-1485177 modbus: sc-error: "Message too long"
120 1481843-1489849 modbus: cs-crc: "CRC correct"
121 1506728-1510062 modbus: sc-server-id: "Slave ID: 247"
122 1506728-1510062 modbus: cs-server-id: "Slave ID: 247"
123 1511304-1514638 modbus: sc-function: "Function 3: Read Holding Registers"
124 1511304-1514638 modbus: cs-function: "Function 3: Read Holding Registers"
125 1515880-1519214 modbus: sc-length: "Byte count: 4"
126 1515880-1523789 modbus: cs-address: "Start at address 0x400 / 31025"
127 1520455-1528365 modbus: sc-data: "0x0000 / 0"
128 1525031-1532941 modbus: cs-length: "Read 0 units of data"
129 1529607-1537516 modbus: sc-data: "0x0000 / 0"
130 1534182-1542092 modbus: cs-error: "CRC should be 80 108"
131 1538758-1546667 modbus: sc-crc: "CRC correct"
132 1543333-1546667 modbus: cs-error: "Unknown function"
133 1891673-1895007 modbus: sc-server-id: "Slave ID: 247"
134 1891673-1895007 modbus: cs-server-id: "Slave ID: 247"
135 1896343-1899677 modbus: sc-function: "Function 3: Read Holding Registers"
136 1896343-1899677 modbus: cs-function: "Function 3: Read Holding Registers"
137 1900994-1904328 modbus: sc-length: "Byte count: 0"
138 1900994-1908999 modbus: cs-address: "Start at address 0x0 / 30001"
139 1905665-1913649 modbus: sc-error: "CRC should be 192 194"
140 1910315-1918321 modbus: cs-length: "Read 2 units of data"
141 1914987-1922971 modbus: sc-error: "Message too long"
142 1919637-1927642 modbus: cs-crc: "CRC correct"
143 1944531-1947865 modbus: sc-server-id: "Slave ID: 247"
144 1944531-1947865 modbus: cs-server-id: "Slave ID: 247"
145 1949107-1952441 modbus: sc-function: "Function 3: Read Holding Registers"
146 1949107-1952441 modbus: cs-function: "Function 3: Read Holding Registers"
147 1953683-1957017 modbus: sc-length: "Byte count: 4"
148 1953683-1961592 modbus: cs-address: "Start at address 0x400 / 31025"
149 1958258-1966168 modbus: sc-data: "0x0000 / 0"
150 1962834-1970743 modbus: cs-length: "Read 0 units of data"
151 1967409-1975319 modbus: sc-data: "0x0000 / 0"
152 1971985-1979895 modbus: cs-error: "CRC should be 80 108"
153 1976561-1984470 modbus: sc-crc: "CRC correct"
154 1981136-1984470 modbus: cs-error: "Unknown function"
155 2141585-2144919 modbus: sc-server-id: "Slave ID: 247"
156 2141585-2144919 modbus: cs-server-id: "Slave ID: 247"
157 2146255-2149589 modbus: sc-function: "Function 3: Read Holding Registers"
158 2146255-2149589 modbus: cs-function: "Function 3: Read Holding Registers"
159 2150905-2154239 modbus: sc-length: "Byte count: 0"
160 2150905-2158911 modbus: cs-address: "Start at address 0x6 / 30007"
161 2155577-2163561 modbus: sc-error: "CRC should be 192 194"
162 2160227-2168232 modbus: cs-length: "Read 2 units of data"
163 2164898-2172882 modbus: sc-error: "Message too long"
164 2169548-2177554 modbus: cs-crc: "CRC correct"
165 2194423-2197757 modbus: sc-server-id: "Slave ID: 247"
166 2194423-2197757 modbus: cs-server-id: "Slave ID: 247"
167 2198998-2202332 modbus: sc-function: "Function 3: Read Holding Registers"
168 2198998-2202332 modbus: cs-function: "Function 3: Read Holding Registers"
169 2203573-2206907 modbus: sc-length: "Byte count: 4"
170 2203573-2211483 modbus: cs-address: "Start at address 0x400 / 31025"
171 2208149-2216059 modbus: sc-data: "0x0000 / 0"
172 2212725-2220634 modbus: cs-length: "Read 0 units of data"
173 2217300-2225210 modbus: sc-data: "0x0000 / 0"
174 2221876-2229785 modbus: cs-error: "CRC should be 80 108"
175 2226451-2234361 modbus: sc-crc: "CRC correct"
176 2231027-2234361 modbus: cs-error: "Unknown function"
177 2391134-2394468 modbus: sc-server-id: "Slave ID: 247"
178 2391134-2394468 modbus: cs-server-id: "Slave ID: 247"
179 2395804-2399138 modbus: sc-function: "Function 3: Read Holding Registers"
180 2395804-2399138 modbus: cs-function: "Function 3: Read Holding Registers"
181 2400454-2403788 modbus: sc-length: "Byte count: 0"
182 2400454-2408460 modbus: cs-address: "Start at address 0xA / 30011"
183 2405126-2413110 modbus: sc-error: "CRC should be 192 194"
184 2409776-2417781 modbus: cs-length: "Read 2 units of data"
185 2414447-2422431 modbus: sc-error: "Message too long"
186 2419097-2427103 modbus: cs-crc: "CRC correct"
187 2444001-2447335 modbus: sc-server-id: "Slave ID: 247"
188 2444001-2447335 modbus: cs-server-id: "Slave ID: 247"
189 2448577-2451911 modbus: sc-function: "Function 3: Read Holding Registers"
190 2448577-2451911 modbus: cs-function: "Function 3: Read Holding Registers"
191 2453152-2456486 modbus: sc-length: "Byte count: 4"
192 2453152-2461062 modbus: cs-address: "Start at address 0x400 / 31025"
193 2457728-2465637 modbus: sc-data: "0x0000 / 0"
194 2462303-2470213 modbus: cs-length: "Read 0 units of data"
195 2466879-2474789 modbus: sc-data: "0x0000 / 0"
196 2471455-2479364 modbus: cs-error: "CRC should be 80 108"
197 2476030-2483940 modbus: sc-crc: "CRC correct"
198 2480606-2483940 modbus: cs-error: "Unknown function"