X-Git-Url: https://sigrok.org/gitweb/?p=sigrok-dumps.git;a=blobdiff_plain;f=uart%2Fcyrustek_es51978%2FREADME;h=ed7cb52975cf1e3b658c619878cf91e4d9f35c59;hp=5fec3bf2dc9aaf99f3ab1d8ba0e0f38d379af2b6;hb=980c65ccac9f78131a004e7f2dafc5756bdde951;hpb=82da1f4d59e0a69973751f51b3acc1ef951b1257 diff --git a/uart/cyrustek_es51978/README b/uart/cyrustek_es51978/README index 5fec3bf..ed7cb52 100644 --- a/uart/cyrustek_es51978/README +++ b/uart/cyrustek_es51978/README @@ -15,7 +15,7 @@ http://www.cyrustek.com.tw/spec/ES51978.pdf Logic analyzer setup -------------------- -The logic analyzer used was an OpenBench Logic Sniffer: +The logic analyzer used was an OpenBench Logic Sniffer (at 100kHz): Probe RS232 cable ----------------------- @@ -25,7 +25,7 @@ The logic analyzer used was an OpenBench Logic Sniffer: Data ---- -Contains 3 samples sent by the multimeter set in resistance mode, mesuring +Contains 3 samples sent by the multimeter set in resistance mode, measuring skin resistance, a few Mega Ohm. The sigrok command line used was: