------------------------------------------------------------------------------- BTHR968: OOK data ------------------------------------------------------------------------------- This is an example capture of a virtual Oregon Scientific BTHR968 temperature, humidity and pressure sensor which transmits at 433.92 MHz using Manchester encoding and amplitude modulation. The signal was received by an RF Solutions RX12 superhet decoder chip and then passed to the logic analyser. In order to decode the Oregon v2.1 BTHR968 you will need to change the preamble to '1010 ...' in the ook decoder. Currently you can ook decode either a preamble of '1111 ...' or '1010 ...' but not both at the same time, so you can see Oregon v2.1 or v3 sensors. Details: https://gist.github.com/RouquinBlanc/5cb6ff88cd02e68d48ea BTHR918N_ArduinoSender.ino https://www.rfsolutions.co.uk/downloads/1481732062DS-AM-RX12.pdf Logic analyzer setup -------------------- The logic analyzer used was a USBee AX Pro / Saleae Logic clone (at 25kHz): Probe RX12 ---------------- 0 OUT 1 Output from Arduino running virtual BTHR968 Data ---- * oregon_bthr968.sr: Contains a single set of pulses that belong to a virtual Oregon Scientific BTHR968 temperature, humidity and pressure sensor. These should decode as channel 2, battery OK, rollingcode BC, temp 11.2 deg C, humidity 52%, pressure 1013mb, checksum OK.