]> sigrok.org Git - sigrok-cli.git/blobdiff - doc/sigrok-cli.1
Rename 'probe' to 'channel' in most places.
[sigrok-cli.git] / doc / sigrok-cli.1
index 400152eab29840b94c2844df11cb5d81e6da563c..e8d98b062db20ce05c11ae5fc338fa9a4997d142 100644 (file)
@@ -119,7 +119,7 @@ will display 128 bits per line, in hexadecimal:
  0:ffff ffff ffff ffff ffff ffff ffff ffff
  1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
 .sp
  0:ffff ffff ffff ffff ffff ffff ffff ffff
  1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
 .sp
-The lines always start with the probe number (or name, if defined), followed by a colon. If no format is specified, it defaults to
+The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to
 .BR bits:width=64 ,
 like this:
 .sp
 .BR bits:width=64 ,
 like this:
 .sp
@@ -127,18 +127,18 @@ like this:
  1:11111111 00000000 11111111 00000000 [...]
 .TP
 .BR "\-p, \-\-probes " <probelist>
  1:11111111 00000000 11111111 00000000 [...]
 .TP
 .BR "\-p, \-\-probes " <probelist>
-A comma-separated list of probes to be used in the session.
+A comma-separated list of channels to be used in the session.
 .sp
 .sp
-Note that sigrok always names the probes according to how they're shown on
-the enclosure of the hardware. If your logic analyzer numbers the probes 0-15,
-that's how you must specify them with this option. An oscilloscope's probes
+Note that sigrok always names the channels according to how they're shown on
+the enclosure of the hardware. If your logic analyzer numbers the channels 0-15,
+that's how you must specify them with this option. An oscilloscope's channels
 would generally be referred to as "CH1", "CH2", and so on.
 would generally be referred to as "CH1", "CH2", and so on.
-Use the \fB\-\-show\fP option to see a list of probe names for your device.
+Use the \fB\-\-show\fP option to see a list of channel names for your device.
 .sp
 .sp
-The default is to use all the probes available on a device. You can name
-a probe like this:
+The default is to use all the channels available on a device. You can name
+a channel like this:
 .BR "1=CLK" .
 .BR "1=CLK" .
-A range of probes can also be given, in the form
+A range of channels can also be given, in the form
 .BR "1\-5" .
 .sp
 Example:
 .BR "1\-5" .
 .sp
 Example:
@@ -156,18 +156,18 @@ Example:
 The comma-separated list is processed from left to right, i.e. items farther
 to the right override previous items. For example
 .B "1=CS,1=MISO"
 The comma-separated list is processed from left to right, i.e. items farther
 to the right override previous items. For example
 .B "1=CS,1=MISO"
-will set the name of probe 1 to
+will set the name of channel 1 to
 .BR "MISO" .
 .sp
 Also, while
 .B "5=MOSI,6=MISO"
 .BR "MISO" .
 .sp
 Also, while
 .B "5=MOSI,6=MISO"
-will only select probes 5 and 6, and set their names to MISO and MOSI, the
+will only select channels 5 and 6, and set their names to MISO and MOSI, the
 command line
 .B "5=MOSI,6=MISO,1\-8"
 command line
 .B "5=MOSI,6=MISO,1\-8"
-will select probes 1\-8 (including 5 and 6, of course), but the names specified
-for probes 5 and 6 will be reset to the defaults by the
+will select channels 1\-8 (including 5 and 6, of course), but the names specified
+for channels 5 and 6 will be reset to the defaults by the
 .B "1\-8"
 .B "1\-8"
-probe selection.
+channel selection.
 .TP
 .BR "\-g, \-\-channel\-group "<channel\ group>
 Specify the channel group to operate on.
 .TP
 .BR "\-g, \-\-channel\-group "<channel\ group>
 Specify the channel group to operate on.
@@ -178,8 +178,8 @@ with the \-\-show command.
 .TP
 .BR "\-t, \-\-triggers " <triggerlist>
 A comma-separated list of triggers to use, of the form
 .TP
 .BR "\-t, \-\-triggers " <triggerlist>
 A comma-separated list of triggers to use, of the form
-.BR "<probe>=<trigger>" .
-You can use the name or number of the probe, and the trigger itself is a
+.BR "<channel>=<trigger>" .
+You can use the name or number of the channel, and the trigger itself is a
 series of characters:
 .sp
 .BR "0 or 1" :
 series of characters:
 .sp
 .BR "0 or 1" :
@@ -231,7 +231,7 @@ The list of supported options depends entirely on the protocol decoder. Every
 protocol decoder has different options it supports.
 .sp
 Any "options" specified for a protocol decoder which are not actually
 protocol decoder has different options it supports.
 .sp
 Any "options" specified for a protocol decoder which are not actually
-supported options, will be interpreted as being probe name/number assignments.
+supported options, will be interpreted as being channel name/number assignments.
 .sp
 Example:
 .sp
 .sp
 Example:
 .sp
@@ -245,8 +245,8 @@ In this example,
 is an option supported by the
 .B spi
 protocol decoder. Additionally, the user tells sigrok to decode the SPI
 is an option supported by the
 .B spi
 protocol decoder. Additionally, the user tells sigrok to decode the SPI
-protocol using probe 1 as MISO signal for SPI, probe 5 as MOSI, probe 3
-as SCK, and probe 0 as CS# signal.
+protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3
+as SCK, and channel 0 as CS# signal.
 .TP
 .BR "\-S, \-\-protocol\-decoder\-stack " <stack>
 This option allows the user to specify a protocol decoder stack, i.e.
 .TP
 .BR "\-S, \-\-protocol\-decoder\-stack " <stack>
 This option allows the user to specify a protocol decoder stack, i.e.
@@ -283,7 +283,7 @@ i.e., the
 is stacked on top of the
 .BR i2c " decoder."
 .sp
 is stacked on top of the
 .BR i2c " decoder."
 .sp
-The respective protocol decoder options and probe name/number assignments
+The respective protocol decoder options and channel name/number assignments
 must be given using the
 .B \-P
 option (you cannot specify them in the
 must be given using the
 .B \-P
 option (you cannot specify them in the
@@ -367,13 +367,13 @@ Example:
 .br
  The following devices were found:
 .br
 .br
  The following devices were found:
 .br
- Demo device with 8 probes: 0 1 2 3 4 5 6 7
+ Demo device with 8 channels: 0 1 2 3 4 5 6 7
 .br
 .br
- ChronoVu LA8 with 8 probes: 0 1 2 3 4 5 6 7
+ ChronoVu LA8 with 8 channels: 0 1 2 3 4 5 6 7
 .br
 .br
- ALSA: HDA ATI SB ALC270 Analog with 2 probes: Ch_0 Ch_1
+ ALSA: HDA ATI SB ALC270 Analog with 2 channels: Ch_0 Ch_1
 .br
 .br
- Saleae Logic with 8 probes: 0 1 2 3 4 5 6 7
+ Saleae Logic with 8 channels: 0 1 2 3 4 5 6 7
 .sp
 However, not all devices are auto-detectable (e.g. serial port based ones).
 For those you'll have to provide a \fBconn\fP option, see above.
 .sp
 However, not all devices are auto-detectable (e.g. serial port based ones).
 For those you'll have to provide a \fBconn\fP option, see above.
@@ -383,7 +383,7 @@ For those you'll have to provide a \fBconn\fP option, see above.
 .br
  The following devices were found:
 .br
 .br
  The following devices were found:
 .br
- Digitek DT4000ZC with 1 probe: P1
+ Digitek DT4000ZC with 1 channel: P1
 .TP
 .BR "\-\-time " <ms>
 Sample for
 .TP
 .BR "\-\-time " <ms>
 Sample for
@@ -431,7 +431,7 @@ Alternatively, you can also use:
 .TP
 .B "  sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
 .TP
 .TP
 .B "  sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
 .TP
-To capture data from the first 4 probes using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
+To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
 0:high, 1:rising, 2:low, 3:high, use:
 .TP
 .nf
 0:high, 1:rising, 2:low, 3:high, use:
 .TP
 .nf