]> sigrok.org Git - sigrok-cli.git/blobdiff - doc/sigrok-cli.1
Update the manpage.
[sigrok-cli.git] / doc / sigrok-cli.1
index 8437d91f3b76ef0ea84fb25ddb5fa93c994052a3..c2e80734af466406af286f3743b613ef0ac52a8c 100644 (file)
@@ -1,4 +1,4 @@
-.TH SIGROK\-CLI 1 "Feb 05, 2013"
+.TH SIGROK\-CLI 1 "May 04, 2014"
 .SH "NAME"
 sigrok\-cli \- Command-line client for the sigrok software
 .SH "SYNOPSIS"
@@ -42,7 +42,7 @@ Some USB devices don't use a unique VendorID/ProductID combination, and thus
 need that specified as well. This also uses the \fBconn\fP option, using
 either \fBVendorID.ProductID\fP or \fBbus.address\fP:
 .sp
-.RB "  $ " "sigrok\-cli \-\-driver=nexus-osciprime:conn=04b4.8613"
+.RB "  $ " "sigrok\-cli \-\-driver=uni-t-ut61e:conn=1a86.e008"
 .TP
 .BR "\-c, \-\-config " <device>
 A colon-separated list of device options, where each option takes the form
@@ -119,33 +119,33 @@ will display 128 bits per line, in hexadecimal:
  0:ffff ffff ffff ffff ffff ffff ffff ffff
  1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
 .sp
-The lines always start with the probe number (or name, if defined), followed by a colon. If no format is specified, it defaults to
+The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to
 .BR bits:width=64 ,
 like this:
 .sp
  0:11111111 11111111 11111111 11111111 [...]
  1:11111111 00000000 11111111 00000000 [...]
 .TP
-.BR "\-p, \-\-probes " <probelist>
-A comma-separated list of probes to be used in the session.
+.BR "\-C, \-\-channels " <channellist>
+A comma-separated list of channels to be used in the session.
 .sp
-Note that sigrok always names the probes according to how they're shown on
-the enclosure of the hardware. If your logic analyzer numbers the probes 0-15,
-that's how you must specify them with this option. An oscilloscope's probes
+Note that sigrok always names the channels according to how they're shown on
+the enclosure of the hardware. If your logic analyzer numbers the channels 0-15,
+that's how you must specify them with this option. An oscilloscope's channels
 would generally be referred to as "CH1", "CH2", and so on.
-Use the \fB\-\-show\fP option to see a list of probe names for your device.
+Use the \fB\-\-show\fP option to see a list of channel names for your device.
 .sp
-The default is to use all the probes available on a device. You can name
-a probe like this:
+The default is to use all the channels available on a device. You can name
+a channel like this:
 .BR "1=CLK" .
-A range of probes can also be given, in the form
+A range of channels can also be given, in the form
 .BR "1\-5" .
 .sp
 Example:
 .sp
 .RB "  $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100"
 .br
-.B "               \-\-probes 1=CLK,2\-4,7"
+.B "               \-\-channels 1=CLK,2\-4,7"
 .br
  CLK:11111111 11111111 11111111 11111111 [...]
    2:11111111 11111111 11111111 11111111 [...]
@@ -155,24 +155,21 @@ Example:
 .sp
 The comma-separated list is processed from left to right, i.e. items farther
 to the right override previous items. For example
-.B "1=CS,1=MISO"
-will set the name of probe 1 to
+.B "1=CS,CS=MISO"
+will set the name of channel 1 to
 .BR "MISO" .
-.sp
-Also, while
-.B "5=MOSI,6=MISO"
-will only select probes 5 and 6, and set their names to MISO and MOSI, the
-command line
-.B "5=MOSI,6=MISO,1\-8"
-will select probes 1\-8 (including 5 and 6, of course), but the names specified
-for probes 5 and 6 will be reset to the defaults by the
-.B "1\-8"
-probe selection.
+.TP
+.BR "\-g, \-\-channel\-group "<channel\ group>
+Specify the channel group to operate on.
+
+Some devices organize channels into groups, the settings of which can
+only be changed as a group. The list of channel groups, if any, is displayed
+with the \fB\-\-show\fP command.
 .TP
 .BR "\-t, \-\-triggers " <triggerlist>
 A comma-separated list of triggers to use, of the form
-.BR "<probe>=<trigger>" .
-You can use the name or number of the probe, and the trigger itself is a
+.BR "<channel>=<trigger>" .
+You can use the name or number of the channel, and the trigger itself is a
 series of characters:
 .sp
 .BR "0 or 1" :
@@ -216,28 +213,30 @@ of options, where each option takes the form
 Example:
 .sp
  $
-.B "sigrok\-cli \-i <file.sr> \-P uart:baudrate=115200:parity=odd"
+.B "sigrok\-cli \-i <file.sr> "
+.br
+.B "              \-P uart:baudrate=115200:parity_type=odd"
 .sp
 The list of supported options depends entirely on the protocol decoder. Every
 protocol decoder has different options it supports.
 .sp
 Any "options" specified for a protocol decoder which are not actually
-supported options, will be interpreted as being probe name/number assignments.
+supported options, will be interpreted as being channel name/number assignments.
 .sp
 Example:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr>"
 .br
-.B "              \-P spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0"
+.B "              \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0"
 .sp
 In this example,
 .B wordsize
 is an option supported by the
 .B spi
 protocol decoder. Additionally, the user tells sigrok to decode the SPI
-protocol using probe 1 as MISO signal for SPI, probe 5 as MOSI, probe 3
-as SCK, and probe 0 as CS# signal.
+protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3
+as CLK, and channel 0 as CS# signal.
 .TP
 .BR "\-S, \-\-protocol\-decoder\-stack " <stack>
 This option allows the user to specify a protocol decoder stack, i.e.
@@ -253,13 +252,13 @@ output. In addition to the
 .B \-S
 option, all protocol decoders that are used in a stack, must also be specified
 (together with their options, if any) using the
-.B \-A
+.B \-P
 parameter.
 .sp
 Example:
 .sp
  $
-.B "sigrok\-cli \-i <file.sr> \-A i2c:sda=4:scl=7,rtc8564"
+.B "sigrok\-cli \-i <file.sr> \-P i2c:sda=4:scl=7,rtc8564"
 .br
 .B "              \-S i2c,rtc8564"
 .sp
@@ -274,7 +273,7 @@ i.e., the
 is stacked on top of the
 .BR i2c " decoder."
 .sp
-The respective protocol decoder options and probe name/number assignments
+The respective protocol decoder options and channel name/number assignments
 must be given using the
 .B \-P
 option (you cannot specify them in the
@@ -289,21 +288,28 @@ display, by specifying its ID:
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid -A i2c"
 .sp
-If a protocol decoder has multiple annotation formats, you can also specify
-which of them to show by specifying its short description like this:
+If a protocol decoder has multiple annotations, you can also specify
+which one of them to show by specifying its short description like this:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
-.B "              \-A i2c=rawhex"
+.B "              \-A i2c=data-read"
+.sp
+Select multiple annotations by separating them with a colon:
+.sp
+ $
+.B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
+.br
+.B "              \-A i2c=data-read:data-write"
 .sp
 You can also select multiple protocol decoders, with an optional selected
-annotation format each, by separating them with commas:
+annotation each, by separating them with commas:
 .sp
  $
 .B "sigrok\-cli \-i <file.sr> \-P i2c,i2cfilter,edid"
 .br
-.B "              \-A i2c=rawhex,edid"
+.B "              \-A i2c=data-read:data-write,edid"
 .TP
 .BR "\-l, \-\-loglevel " <level>
 Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP
@@ -351,13 +357,9 @@ Example:
 .br
  The following devices were found:
 .br
- Demo device with 8 probes: 0 1 2 3 4 5 6 7
-.br
- ChronoVu LA8 with 8 probes: 0 1 2 3 4 5 6 7
-.br
- ALSA: HDA ATI SB ALC270 Analog with 2 probes: Ch_0 Ch_1
+ demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3
 .br
Saleae Logic with 8 probes: 0 1 2 3 4 5 6 7
fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7
 .sp
 However, not all devices are auto-detectable (e.g. serial port based ones).
 For those you'll have to provide a \fBconn\fP option, see above.
@@ -367,16 +369,15 @@ For those you'll have to provide a \fBconn\fP option, see above.
 .br
  The following devices were found:
 .br
- Digitek DT4000ZC with 1 probe: P1
+ Digitek DT4000ZC with 1 channel: P1
 .TP
 .BR "\-\-time " <ms>
 Sample for
 .B <ms>
 milliseconds, then quit.
 .sp
-You can optionally follow the number by \fBs\fP, \fBms\fP, \fBus\fP, or
-\fBns\fP to specify the time to sample in seconds, milliseconds, microseconds,
-or nanoseconds, respectively.
+You can optionally follow the number by \fBs\fP to specify the time to
+sample in seconds.
 .sp
 For example,
 .B "\-\-time 2s"
@@ -415,12 +416,12 @@ Alternatively, you can also use:
 .TP
 .B "  sigrok\-cli \-\-driver fx2lafw \-\-time 3s"
 .TP
-To capture data from the first 4 probes using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
+To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition
 0:high, 1:rising, 2:low, 3:high, use:
 .TP
 .nf
 \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP
-\fB\-\-output\-format bits \-\-probes 0\-3 \-\-wait\-trigger \\\fP
+\fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP
 \fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP
 .TP
 To turn on internal logging on a Lascar EL-USB series device: