.TH SIGROK\-CLI 1 "May 04, 2014" .SH "NAME" sigrok\-cli \- Command-line client for the sigrok software .SH "SYNOPSIS" .B sigrok\-cli [OPTIONS] [COMMAND] .SH "DESCRIPTION" \fBsigrok\-cli\fP is a cross-platform command line utility for the \fBsigrok\fP software. .PP It cannot display graphical output, but is still sufficient to run through the whole process of hardware initialization, acquisition, protocol decoding and saving the session. .PP It is useful for running on remote or embedded systems, netbooks, PDAs, and for various other use-cases. It can display samples on standard output or save them in various file formats. .SH OPTIONS .TP .B "\-h, \-\-help" Show a help text and exit. .TP .B "\-V, \-\-version" Show .B sigrok-cli version, and information about supported hardware drivers, input file formats, output file formats, and protocol decoders. .TP \fB\-d, \-\-driver\fP A driver must always be selected (unless doing a global scan). Use the \fB-V\fP option to get a list of available drivers. .sp Drivers can take options, in the form \fBkey=value\fP separated by colons. .sp Drivers communicating with hardware via a serial port always need the port specified as the \fBconn\fP option. For example, to use the Openbench Logic Sniffer: .sp .RB " $ " "sigrok\-cli \-\-driver=ols:conn=/dev/ttyACM0" .sp Some USB devices don't use a unique VendorID/ProductID combination, and thus need that specified as well. This also uses the \fBconn\fP option, using either \fBVendorID.ProductID\fP or \fBbus.address\fP: .sp .RB " $ " "sigrok\-cli \-\-driver=uni-t-ut61e:conn=1a86.e008" .TP .BR "\-c, \-\-config " A colon-separated list of device options, where each option takes the form .BR key=value . For example, to set the samplerate to 1MHz on a device supported by the fx2lafw driver, you might specify .sp .RB " $ " "sigrok\-cli \-\-driver=fx2lafw \-\-config samplerate=1m" .sp Samplerate is an option common to most logic analyzers. The argument specifies the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz. The following are all equivalent: .sp .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config samplerate=1000000" .sp .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config samplerate=1m" .sp .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-config \(dqsamplerate=1 MHz\(dq" .TP .BR "\-i, \-\-input\-file " Load input from a file instead of a hardware device. If the .B \-\-input\-format option is not supplied, sigrok-cli attempts to autodetect the file format of the input file. .TP .BR "\-I, \-\-input\-format " When loading an input file, assume it's in the specified format. If this option is not supplied (in addition to .BR \-\-input\-file ), sigrok-cli attempts to autodetect the file format of the input file. Use the .B \-V option to see a list of available input formats. .sp The format name may optionally be followed by a colon-separated list of options, where each option takes the form .BR "key=value" . .TP .BR "\-o, \-\-output\-file " Save output to a file instead of writing it to stdout. The default format used when saving is the sigrok session file format. This can be changed with the .B \-\-output\-format option. .TP .BR "\-O, \-\-output\-format " Set the output format to use. Use the .B \-V option to see a list of available output formats. .sp The format name may optionally be followed by a colon-separated list of options, where each option takes the form .BR "key=value" . .sp Supported formats currently include .BR bits , .BR hex , .BR ascii , .BR binary , .BR vcd , .BR ols , .BR gnuplot , .BR chronovu-la8 , .BR csv ", and" .BR analog . .sp The .B bits or .B hex formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus .B hex:width=128 will display 128 bits per line, in hexadecimal: .sp 0:ffff ffff ffff ffff ffff ffff ffff ffff 1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00 .sp The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to .BR bits:width=64 , like this: .sp 0:11111111 11111111 11111111 11111111 [...] 1:11111111 00000000 11111111 00000000 [...] .TP .BR "\-C, \-\-channels " A comma-separated list of channels to be used in the session. .sp Note that sigrok always names the channels according to how they're shown on the enclosure of the hardware. If your logic analyzer numbers the channels 0-15, that's how you must specify them with this option. An oscilloscope's channels would generally be referred to as "CH1", "CH2", and so on. Use the \fB\-\-show\fP option to see a list of channel names for your device. .sp The default is to use all the channels available on a device. You can name a channel like this: .BR "1=CLK" . A range of channels can also be given, in the form .BR "1\-5" . .sp Example: .sp .RB " $ " "sigrok\-cli \-\-driver fx2lafw \-\-samples 100" .br .B " \-\-channels 1=CLK,2\-4,7" .br CLK:11111111 11111111 11111111 11111111 [...] 2:11111111 11111111 11111111 11111111 [...] 3:11111111 11111111 11111111 11111111 [...] 4:11111111 11111111 11111111 11111111 [...] 7:11111111 11111111 11111111 11111111 [...] .sp The comma-separated list is processed from left to right, i.e. items farther to the right override previous items. For example .B "1=CS,CS=MISO" will set the name of channel 1 to .BR "MISO" . .TP .BR "\-g, \-\-channel\-group " Specify the channel group to operate on. Some devices organize channels into groups, the settings of which can only be changed as a group. The list of channel groups, if any, is displayed with the \fB\-\-show\fP command. .TP .BR "\-t, \-\-triggers " A comma-separated list of triggers to use, of the form .BR "=" . You can use the name or number of the channel, and the trigger itself is a series of characters: .sp .BR "0 or 1" : A low or high value on the pin. .br .BR "r or f" : A rising or falling value on the pin. An .B r effectively corresponds to .BR 01 . .br .BR "e" : Any kind of change on a pin (either a rising or a falling edge). .sp Not every device supports all of these trigger types. Use the \fB\-\-show\fP command to see which triggers your device supports. .TP .BR "\-w, \-\-wait-trigger" Don't output any sample data (even if it's actually received from the hardware) before the trigger condition is met. In other words, do not output any pre-trigger data. This option is useful if you don't care about the data that came before the trigger (but the hardware delivers this data to sigrok nonetheless). .TP .BR "\-P, \-\-protocol\-decoders " This option allows the user to specify a comma-separated list of protocol decoders to be used in this session. The decoders are specified by their ID, as shown in the .B \-\-version output. .sp Example: .sp $ .B "sigrok\-cli \-i \-P i2c" .sp Each protocol decoder can optionally be followed by a colon-separated list of options, where each option takes the form .BR "key=value" . .sp Example: .sp $ .B "sigrok\-cli \-i " .br .B " \-P uart:baudrate=115200:parity_type=odd" .sp The list of supported options depends entirely on the protocol decoder. Every protocol decoder has different options it supports. .sp Any "options" specified for a protocol decoder which are not actually supported options, will be interpreted as being channel name/number assignments. .sp Example: .sp $ .B "sigrok\-cli \-i " .br .B " \-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0" .sp In this example, .B wordsize is an option supported by the .B spi protocol decoder. Additionally, the user tells sigrok to decode the SPI protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3 as CLK, and channel 0 as CS# signal. .TP .BR "\-A, \-\-protocol\-decoder\-annotations " By default, only the stack's topmost protocol decoder's annotation output is shown. With this option another decoder's annotation can be selected for display, by specifying its ID: .sp $ .B "sigrok\-cli \-i \-P i2c,i2cfilter,edid -A i2c" .sp If a protocol decoder has multiple annotations, you can also specify which one of them to show by specifying its short description like this: .sp $ .B "sigrok\-cli \-i \-P i2c,i2cfilter,edid" .br .B " \-A i2c=data-read" .sp Select multiple annotations by separating them with a colon: .sp $ .B "sigrok\-cli \-i \-P i2c,i2cfilter,edid" .br .B " \-A i2c=data-read:data-write" .sp You can also select multiple protocol decoders, with an optional selected annotation each, by separating them with commas: .sp $ .B "sigrok\-cli \-i \-P i2c,i2cfilter,edid" .br .B " \-A i2c=data-read:data-write,edid" .TP .BR "\-M, \-\-protocol\-decoder\-meta " When given, show protocol decoder meta output instead of annotations. The argument is the name of the decoder whose meta output to show. .sp $ .B "sigrok\-cli \-i \-M i2c" .sp Not every decoder generates meta output. .TP .BR "\-B, \-\-protocol\-decoder\-binary " When given, decoder "raw" data of various kinds is written to stdout instead of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP files, PNG files, or anything else; this is entirely dependent on the decoder and what kinds of binary output make sense for that decoder). .sp No other information is printed to stdout, so this is suitable for piping into other programs or saving to a file. .sp Protocol decoders that support binary output publish a list of binary classes, for example the UART decoder might have "TX" and "RX". To select TX for output, the argument to this option would be: .sp $ .B "sigrok\-cli \-i \-B uart=tx" .br .sp If only the protocol decoder is specified, without binary class, all classes are written to stdout: .sp $ .B "sigrok\-cli \-i \-B uart" .sp (this is only useful in rare cases, generally you would specify a certain binary class you're interested in) .sp Not every decoder generates binary output. .TP .BR "\-l, \-\-loglevel " Set the libsigrok and libsigrokdecode loglevel. At the moment \fBsigrok-cli\fP doesn't support setting the two loglevels independently. The higher the number, the more debug output will be printed. Valid loglevels are: .sp \fB0\fP None .br \fB1\fP Error .br \fB2\fP Warnings .br \fB3\fP Informational .br \fB4\fP Debug .br \fB5\fP Spew .TP .B "\-\-show" .br Show information about the selected option. For example, to see options for a connected fx2lafw device: .sp $ .B "sigrok\-cli \-\-driver fx2lafw \-\-show .sp In order to properly get device options for your hardware, some drivers might need a serial port specified: .sp $ .B "sigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-show .sp This also works for protocol decoders, input modules and output modules: .sp $ .B "sigrok\-cli \-\-protocol\-decoders i2c \-\-show $ .B "sigrok\-cli \-\-input\-format csv \-\-show $ .B "sigrok\-cli \-\-output\-format bits \-\-show .TP .B "\-\-scan" Scan for devices that can be detected automatically. .sp Example: .sp $ .B "sigrok\-cli \-\-scan .br The following devices were found: .br demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3 .br fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7 .sp However, not all devices are auto-detectable (e.g. serial port based ones). For those you'll have to provide a \fBconn\fP option, see above. .sp $ .B "sigrok\-cli \-\-driver digitek-dt4000zc:conn=/dev/ttyUSB0 \-\-scan .br The following devices were found: .br Digitek DT4000ZC with 1 channel: P1 .TP .BR "\-\-time " Sample for .B milliseconds, then quit. .sp You can optionally follow the number by \fBs\fP to specify the time to sample in seconds. .sp For example, .B "\-\-time 2s" will sample for two seconds. .TP .BR "\-\-samples " Acquire .B samples, then quit. .sp You can optionally follow the number by \fBk\fP, \fBm\fP, or \fBg\fP to specify the number of samples in kilosamples, megasamples, or gigasamples, respectively. .sp For example, .B "\-\-samples 3m" will acquire 3000000 samples. .TP .BR "\-\-frames " Acquire .B frames, then quit. .TP .BR "\-\-continuous" Sample continuously until stopped. Not all devices support this. .TP .BR "\-\-get " Get the value of .B from the specified device and print it. .TP .BR "\-\-set" Set one or more variables specified with the \fB\-\-config\fP option, without doing any acquisition. .SH EXAMPLES In order to get exactly 100 samples from the connected fx2lafw-supported logic analyzer hardware, run the following command: .TP .B " sigrok\-cli \-\-driver fx2lafw \-\-samples 100" .TP If you want to sample data for 3 seconds (3000 ms), use: .TP .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3000" .TP Alternatively, you can also use: .TP .B " sigrok\-cli \-\-driver fx2lafw \-\-time 3s" .TP To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition 0:high, 1:rising, 2:low, 3:high, use: .TP .nf \fBsigrok\-cli \-\-driver ols:conn=/dev/ttyACM0 \-\-config samplerate=10m \\\fP \fB\-\-output\-format bits \-\-channels 0\-3 \-\-wait\-trigger \\\fP \fB\-\-triggers 0=1,1=r,2=0,3=1 \-\-time 100\fP .TP To turn on internal logging on a Lascar EL-USB series device: .TP \fBsigrok\-cli \-\-driver lascar\-el\-usb:conn=10c4.0002 \\\fP \fB\-\-config datalog=on \-\-set\fP .SH "EXIT STATUS" .B sigrok\-cli exits with 0 on success, 1 on most failures. .SH "SEE ALSO" \fBpulseview\fP(1) .SH "BUGS" Please report any bugs via Bugzilla .RB "(" http://sigrok.org/bugzilla ")" or on the sigrok\-devel mailing list .RB "(" sigrok\-devel@lists.souceforge.net ")." .SH "LICENSE" .B sigrok\-cli is covered by the GNU General Public License (GPL). Some portions are licensed under the "GPL v2 or later", some under "GPL v3 or later". .SH "AUTHORS" Please see the individual source code files. .PP This manual page was written by Uwe Hermann . It is licensed under the terms of the GNU GPL (version 2 or later).