]> sigrok.org Git - libsigrokdecode.git/blobdiff - decoders/i2c/__init__.py
Change PD options to be a tuple of dictionaries.
[libsigrokdecode.git] / decoders / i2c / __init__.py
index 6af7ebedc59389c3af750379b8f5943dfd5bc3ce..ba40245ebc6aeb3d44d897789e81b4ff4b27f0b2 100644 (file)
 ##
 
 '''
-I2C protocol decoder.
-
-The Inter-Integrated Circuit (I2C) bus is a bidirectional, multi-master
+I²C (Inter-Integrated Circuit) is a bidirectional, multi-master
 bus using two signals (SCL = serial clock line, SDA = serial data line).
-
-There can be many devices on the same bus. Each device can potentially be
-master or slave (and that can change during runtime). Both slave and master
-can potentially play the transmitter or receiver role (this can also
-change at runtime).
-
-Possible maximum data rates:
- - Standard mode: 100 kbit/s
- - Fast mode: 400 kbit/s
- - Fast-mode Plus: 1 Mbit/s
- - High-speed mode: 3.4 Mbit/s
-
-START condition (S): SDA = falling, SCL = high
-Repeated START condition (Sr): same as S
-Data bit sampling: SCL = rising
-STOP condition (P): SDA = rising, SCL = high
-
-All data bytes on SDA are exactly 8 bits long (transmitted MSB-first).
-Each byte has to be followed by a 9th ACK/NACK bit. If that bit is low,
-that indicates an ACK, if it's high that indicates a NACK.
-
-After the first START condition, a master sends the device address of the
-slave it wants to talk to. Slave addresses are 7 bits long (MSB-first).
-After those 7 bits, a data direction bit is sent. If the bit is low that
-indicates a WRITE operation, if it's high that indicates a READ operation.
-
-Later an optional 10bit slave addressing scheme was added.
-
-Documentation:
-http://www.nxp.com/acrobat/literature/9398/39340011.pdf (v2.1 spec)
-http://www.nxp.com/acrobat/usermanuals/UM10204_3.pdf (v3 spec)
-http://en.wikipedia.org/wiki/I2C
-
-Protocol output format:
-
-I2C packet:
-[<cmd>, <data>]
-
-<cmd> is one of:
- - 'START' (START condition)
- - 'START REPEAT' (Repeated START condition)
- - 'ADDRESS READ' (Slave address, read)
- - 'ADDRESS WRITE' (Slave address, write)
- - 'DATA READ' (Data, read)
- - 'DATA WRITE' (Data, write)
- - 'STOP' (STOP condition)
- - 'ACK' (ACK bit)
- - 'NACK' (NACK bit)
-
-<data> is the data or address byte associated with the 'ADDRESS*' and 'DATA*'
-command. Slave addresses do not include bit 0 (the READ/WRITE indication bit).
-For example, a slave address field could be 0x51 (instead of 0xa2).
-For 'START', 'START REPEAT', 'STOP', 'ACK', and 'NACK' <data> is None.
-
 '''
 
 from .pd import *