From: Wolfram Sang Date: Wed, 2 Jan 2019 12:15:22 +0000 (+0100) Subject: ols: extend reponse delay when scanning device X-Git-Url: https://sigrok.org/gitweb/?p=libsigrok.git;a=commitdiff_plain;h=ae4e6999c5de46d54cf76ce6cb2184cab7c18341 ols: extend reponse delay when scanning device My Pepino needs 15ms instead of 10ms, so let's use 20ms to be on the safe side. Signed-off-by: Wolfram Sang --- diff --git a/src/hardware/openbench-logic-sniffer/api.c b/src/hardware/openbench-logic-sniffer/api.c index 8ff1456d..26490c05 100644 --- a/src/hardware/openbench-logic-sniffer/api.c +++ b/src/hardware/openbench-logic-sniffer/api.c @@ -83,7 +83,7 @@ static const uint64_t samplerates[] = { SR_HZ(1), }; -#define RESPONSE_DELAY_US (10 * 1000) +#define RESPONSE_DELAY_US (20 * 1000) static GSList *scan(struct sr_dev_driver *di, GSList *options) {