X-Git-Url: https://sigrok.org/gitweb/?p=libsigrok.git;a=blobdiff_plain;f=README.devices;h=97aca27838dc872eda5bbba14979c1e20445388f;hp=8fc9d7b80aed58ff8e8f749ad1c922f76c850136;hb=358105152aaceb9065e4a18b2b0e0a1fc118eecb;hpb=ebc51109899008694c50977cb2574050b1bc0c89 diff --git a/README.devices b/README.devices index 8fc9d7b8..97aca278 100644 --- a/README.devices +++ b/README.devices @@ -136,6 +136,7 @@ The following drivers/devices do not need any firmware upload: - pce-322a - pipistrello-ols - rdtech-dps + - rigol-dg - rigol-ds - rohde-schwarz-sme-0x - scpi-dmm @@ -185,6 +186,7 @@ Formal syntax for serial communication: conn=hid[/]/usb=.[.] conn=hid[/]/raw= conn=hid[/]/sn= + conn=hid[/]/iokit= chip can be: bu86x, ch9325, cp2110, victor path may contain slashes path and serno are "greedy" (span to the end of the spec) @@ -274,6 +276,20 @@ rules shipped by the system will be broken. Please consult the udev docs for details. +Non-default drivers for commodity chips +--------------------------------------- + +Some vendors include common USB chips in their products yet assign device +specific VID:PID pairs. Which results in the necessity for extra steps +before the serial port can be used: + +- GW Instek VCP, found in GDM-8000 and probably other meters: Install the + vendors Windows driver to get access to a COM port. Or force the driver + assignment on Linux: + # modprobe cp210x + # echo 2184 0030 > /sys/bus/usb-serial/drivers/cp210x/new_id + + Cypress FX2 based devices ------------------------- @@ -389,6 +405,9 @@ a short list for convenience: 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must be configured to the same baud rate as the host (default 9600). Multimeter and interface must be configured to the same address. + - GW Instek GDM-397: Press the "REL/RS232C (USB)" button for roughly 1 second. + - GW Instek VCP: See the discussion on manual driver assignment to common + USB to UART chips with non-default USB identification. - MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds. - Metrix MX56C: Press the PRINT button to have the meter send acquisition data via IR. Hold the PRINT button to adjust the meter's transmission @@ -453,6 +472,16 @@ Example: $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ... +JTAGulator +---------- + +The Grand Idea Studio JTAGulator also implements the SUMP protocol and +thus is covered by the OLS driver. See the vendor's wiki on details how +to enable the Logic Analyzer mode of operation. + + https://github.com/grandideastudio/jtagulator/wiki/Logic-Analyzer + + Mooshimeter -----------