X-Git-Url: https://sigrok.org/gitweb/?a=blobdiff_plain;f=README.devices;h=ecd2ffc0670e029a233f3a55b3adb81ebc5bcaea;hb=5fa12e93e3f1cf2825591e76e1f63d974fec9cc2;hp=ae3ac5098a38b9312ca1a6195b1ee6cd6efee6db;hpb=c77ed446f2c08e2906883023c85feafa19a0ec10;p=libsigrok.git diff --git a/README.devices b/README.devices old mode 100755 new mode 100644 index ae3ac509..ecd2ffc0 --- a/README.devices +++ b/README.devices @@ -42,26 +42,36 @@ The following drivers/devices require a firmware upload upon connection: These can be extracted from the vendor's Windows drivers using a tool from our 'sigrok-util' repository/project. - - nexus-osciprime: The Nexus Computing OsciPrime PC oscilloscope needs - firmware files. These are available from the vendor website. + - saleae-logic16: The Saleae Logic16 needs a firmware file for the + Cypress FX2 chip in the device, as well as two FPGA bitstream files. + These can be extracted from the vendor's Linux application using a tool + from our 'sigrok-util' repository/project. The following drivers/devices do not need any firmware upload: - agilent-dmm - alsa - brymen-dmm + - cem-dt-885x + - center-3xx - chronovu-la8 - colead-slm - demo - fluke-dmm + - ikalogic-scanalogic2 + - ikalogic-scanaplus + - kecheng-kc-330b - lascar-el-usb - link-mso19 - mic-985xx + - norma-dmm - openbench-logic-sniffer - rigol-ds1xx2 - serial-dmm + - teleinfo - tondaj-sl-814 - uni-t-dmm + - uni-t-ut32x - victor-dmm - zeroplus-logic-cube @@ -84,13 +94,16 @@ The following drivers/devices require a serial port specification: - agilent-dmm - brymen-dmm + - cem-dt-885x + - center-3xx - colead-slm - fluke-dmm - link-mso19 - mic-985xx - - nexus-osciprime + - norma-dmm - openbench-logic-sniffer - serial-dmm + - teleinfo - tondaj-sl-814 The following drivers/devices do not require a serial port specification: @@ -101,9 +114,14 @@ The following drivers/devices do not require a serial port specification: - demo - fx2lafw - hantek-dso + - ikalogic-scanalogic2 + - ikalogic-scanaplus + - kecheng-kc-330b - lascar-el-usb - rigol-ds1xx2 + - saleae-logic16 - uni-t-dmm + - uni-t-ut32x - victor-dmm - zeroplus-logic-cube @@ -215,7 +233,7 @@ UNI-T UT-D04 cable issue on Linux --------------------------------- The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have -a very specific problem on Linux. Apparently it requires a to be put into +a very specific problem on Linux. Apparently it requires to be put into suspend (and woken up again) before it is usable. This seems to be a Linux-only issue, Windows is not affected by this since apparently the Windows kernel does this for every USB device, always. @@ -234,6 +252,28 @@ See also: http://erste.de/UT61/index.html done +Enabling multimeter / data logger measurement output +---------------------------------------------------- + +Some multimeters or data loggers will not start outputting measurement data +unless a certain action has been performed by the user beforehand. This is +usually mentioned in the vendor manual of the respective device, but here's +a short list for convenience: + + - Digitek DT4000ZC: Briefly press the "RS232" button. + - PCE PCE-DM32: Briefly press the "RS232" button. + - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together. + - TekPower TP4000ZC: Briefly press the "RS232" button. + - UNI-T UT61D: Press the "REL/RS232/USB" button for roughly 1 second. + - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it + appears that in practice you don't have to press the button (at least on + some versions of the device), simply connect the device via USB. + - V&A VA18B: Keep the "Hz/DUTY" key pressed while powering on the device. + - Victor 70C: Press the "REL/RS232" button for roughly 1 second. + - Victor 86C: Press the "REL/RS232" button for roughly 1 second. + - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds. + + ALSA driver -----------