X-Git-Url: https://sigrok.org/gitweb/?a=blobdiff_plain;f=README.devices;h=32e2ffc00efa435a20397490fbd17d8771c8b611;hb=80e717b3cfac82d63c98614fe6179fb0e4fdaf8d;hp=935f797280c7c2925e7c055cc87e8e874e4ac5db;hpb=f3f19d1131025b68d29a11273b627c83d748e7ea;p=libsigrok.git diff --git a/README.devices b/README.devices index 935f7972..32e2ffc0 100644 --- a/README.devices +++ b/README.devices @@ -12,9 +12,13 @@ Firmware Some devices supported by libsigrok need a firmware to be uploaded every time the device is connected to the PC (usually via USB), before it can be used. -The default location where libsigrok expects the firmware files is: +The default locations where libsigrok expects the firmware files are: + $SIGROK_FIRMWARE_DIR (environment variable) + $HOME/.local/share/sigrok-firmware $prefix/share/sigrok-firmware + /usr/local/share/sigrok-firmware + /usr/share/sigrok-firmware ($prefix is usually /usr/local or /usr, depending on your ./configure options) @@ -33,30 +37,67 @@ The following drivers/devices require a firmware upload upon connection: 'sigrok-firmware' repository/project under a license which allows us to redistribute them. + - dreamsourcelab-dslogic: The DreamSourceLab DSLogic/DSCope device series + requires various firmware files and FPGA bitstream files. + These can be extracted/downloaded from the vendor's GitHub repo using a + tool from our 'sigrok-util' repository/project. + - fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the firmware files from the 'sigrok-firmware-fx2lafw' repository/project. The firmware is written from scratch and licensed under the GNU GPLv2+. + - hantek-6xxx: Certain oscilloscopes based on the Cypress FX2(LP) chip, such + as the Hantek 6022BE/6022BL, SainSmart DDS120, and Rocktech BM102, need the + firmware files from the 'sigrok-firmware-fx2lafw' repository/project. + The firmware is written from scratch and licensed under the GNU GPLv2+. + - hantek-dso: The Hantek DSO-2090 (and other supported models of the same series of Hantek PC oscilloscopes) need firmware files. These can be extracted from the vendor's Windows drivers using a tool from our 'sigrok-util' repository/project. + - lecroy-logicstudio: The LeCroy LogicStudio requires FPGA bitstream files. + These can be extracted from the vendor's Windows software using a tool + from our 'sigrok-util' repository/project. + Additionally, it requires a Cypress FX2 firmware. This can be extracted + from the vendor's Windows software using another tool. Details: + + http://sigrok.org/wiki/LeCroy_LogicStudio#Firmware + - saleae-logic16: The Saleae Logic16 needs a firmware file for the Cypress FX2 chip in the device, as well as two FPGA bitstream files. These can be extracted from the vendor's Linux application using a tool from our 'sigrok-util' repository/project. - - sysclk-lwla: The Sysclk LWLA1034 requires various bitstream files. - These files are available from our 'sigrok-firmware' repository/project - under a license which allows us to redistribute them. + - saleae-logic-pro: The Saleae Logic Pro 16 needs a firmware file for the + Cypress FX3 chip in the device, as well as an FPGA bitstream file. + These can be extracted from the vendor's Linux application using a tool + from our 'sigrok-util' repository/project. + + - sysclk-lwla: + + - The Sysclk LWLA1034 requires various bitstream files. + These files are available from our 'sigrok-firmware' repository/project + under a license which allows us to redistribute them. + + - The Sysclk LWLA1016 requires various bitstream files. + These can be extracted from the vendor's Windows drivers using a tool + from our 'sigrok-util' repository/project. + + - sysclk-sla5032: The Sysclk SLA5032 needs an FPGA bitstream file. + This file can be copied (and renamed) from the Windows vendor software + installation directory. Details: + + https://sigrok.org/wiki/Sysclk_SLA5032#Firmware The following drivers/devices do not need any firmware upload: - agilent-dmm - appa-55ii + - arachnid-labs-re-load-pro - atten-pps3xxx - - brymen-bm86x + - baylibre-acme + - beaglelogic - brymen-dmm - cem-dt-885x - center-3xx (including all subdrivers) @@ -64,34 +105,66 @@ The following drivers/devices do not need any firmware upload: - colead-slm - conrad-digi-35-cpu - demo + - fluke-45 - fluke-dmm + - ftdi-la - gmc-mh-1x-2x (including all subdrivers) + - gwinstek-gds-800 + - gwinstek-gpd - hameg-hmo + - hantek-4032l + - hp-3457a + - hp-3478a + - hung-chang-dso-2100 - ikalogic-scanalogic2 - ikalogic-scanaplus + - ipdbg-la - kecheng-kc-330b + - kern-scale + - korad-kaxxxxp - lascar-el-usb + - lecroy-xstream - link-mso19 + - manson-hcs-3xxx + - maynuo-m97 - mic-985xx (including all subdrivers) + - microchip-pickit2 + - mooshimeter-dmm + - motech-lps-30x - norma-dmm - openbench-logic-sniffer + - pce-322a - pipistrello-ols + - rdtech-dps - rigol-ds + - rohde-schwarz-sme-0x + - scpi-dmm + - scpi-pps - serial-dmm (including all subdrivers) + - serial-lcr (including all subdrivers) + - siglent-sds - teleinfo + - testo - tondaj-sl-814 - uni-t-dmm (including all subdrivers) - uni-t-ut32x - - victor-dmm - yokogawa-dlm - zeroplus-logic-cube + - zketech-ebd-usb Specifying serial ports ----------------------- Many devices supported by libsigrok use serial port based cables (real RS232 -or USB-to-serial ones) to connect to a PC. +or USB-to-serial ones, CDC class) to connect to a PC. These serial cables are +supported by the libserialport library. Some vendors prefer to use HID chips +instead of CDC chips in their serial cables. These cables can get supported +by means of the hidapi library. Note that each chip type requires specific +support in the libsigrok library. Bluetooth connected devices may be supported +as well when they communicate by means of RFCOMM channels, or one of the +implemented BLE notification/indication approaches, and one of the Bluetooth +supporting platforms is used. For all these devices, you need to specify the serial port they are connected to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan @@ -100,50 +173,42 @@ for such devices without specifying a serial port. Example: $ sigrok-cli --driver :conn=/dev/ttyUSB0 ... - -The following drivers/devices require a serial port specification: - - - agilent-dmm - - appa-55ii - - atten-pps3xxx - - brymen-dmm - - cem-dt-885x - - center-3xx (including all subdrivers) - - colead-slm - - conrad-digi-35-cpu - - fluke-dmm - - gmc-mh-1x-2x (including all subdrivers) - - hameg-hmo - - link-mso19 - - mic-985xx (including all subdrivers) - - norma-dmm - - openbench-logic-sniffer - - rigol-ds (for RS232; not required for USBTMC or TCP) - - serial-dmm (including all subdrivers) - - teleinfo - - tondaj-sl-814 - -The following drivers/devices do not require a serial port specification: - - - asix-sigma - - brymen-bm86x - - chronovu-la - - demo - - fx2lafw - - hantek-dso - - ikalogic-scanalogic2 - - ikalogic-scanaplus - - kecheng-kc-330b - - lascar-el-usb - - pipistrello-ols - - rigol-ds (USBTMC or TCP) - - saleae-logic16 - - sysclk-lwla - - uni-t-dmm (including all subdrivers) - - uni-t-ut32x - - victor-dmm - - yokogawa-dlm (USBTMC or TCP) - - zeroplus-logic-cube + $ sigrok-cli --driver :conn=hid/cp2110 ... + $ sigrok-cli --driver :conn=bt/rfcomm/01-23-45-67-89-ab ... + +Formal syntax for serial communication: + + - COM ports (RS232, USB CDC): + conn= + - USB HID cables: + conn=hid[/] + conn=hid[/]/usb=.[.] + conn=hid[/]/raw= + conn=hid[/]/sn= + chip can be: bu86x, ch9325, cp2110, victor + path may contain slashes + path and serno are "greedy" (span to the end of the spec) + - Bluetooth Classic and Bluetooth Low Energy (BLE): + conn=bt// + conn can be: rfcomm, ble122, nrf51, cc254x + addr can be "dense" or separated, bt/cc254x/0123456789ab or + bt/rfcomm/11-22-33-44-55-66 or bt/ble122/88:6b:12:34:56:78 + (note that colons may not be available when the conn= spec is taken + from a string that separates fields by colon, e.g. in the "--driver + :conn=" example, that is why the dense form and the use + of dashes for separation are supported) + +Some of the drivers implement a default for the connection. Some of the +drivers can auto-detect USB connected devices. + +Beyond strict serial communication over COM ports (discussed above), the +conn= property can also address specific USB devices, as well as specify TCP +or VXI communication parameters. See these examples: + + $ sigrok-cli --driver :conn=. ... + $ sigrok-cli --driver :conn=tcp-raw// ... + $ sigrok-cli --driver :conn=vxi/ ... + $ sigrok-cli --driver :conn=usbtmc/. ... Specifying serial port parameters @@ -174,33 +239,39 @@ For USB-to-serial based devices, we recommended using our udev rules file (see below for details). -Permissions for USB devices (udev rules file) ---------------------------------------------- +Permissions for USB devices (udev rules files) +---------------------------------------------- When using USB-based devices supported by libsigrok, the user running the libsigrok frontend (e.g. sigrok-cli) has to have (read/write) permissions for the respective USB device. -On Linux, this is accomplished using either 'chmod' (not recommended) or -using the udev rules file shipped with libsigrok (recommended). +On Linux, this is accomplished using udev rules. libsigrok ships a rules +file containing all supported devices which can be detected reliably +(generic USB-to-serial converters are omitted, as these are used for a wide +range of devices, e.g. GPS receivers, which are not handled by libsigrok). -The file is available in contrib/z60_libsigrok.rules. It contains entries -for all libsigrok-supported (USB-based) devices and changes their group -to 'plugdev' and the permissions to '664'. +The file is available in contrib/60-libsigrok.rules. This file just contains +the list of devices and flags these devices with ID_SIGROK="1". Access is +granted by the 61-libsigrok-plugdev.rules or 61-libsigrok-uaccess.rules files, +allowing access to members of the plugdev group or to currently logged in +users, respectively. When using a libsigrok package from your favorite Linux distribution, the -packager will have already taken care of properly installing the udev file -in the correct (distro-specific) place, and you don't have to do anything. -The packager might also have adapted 'plugdev' and '664' as needed. +files should already be installed in /usr/lib/udev/rules.d/, i.e. +60-libsigrok.rules and one of the access granting rules files. Use of +61-libsigrok-uaccess.rules is encouraged on systemd distributions. + +The access policy can be locally overridden by placing appropriate rules in +/etc/udev/rules.d/, disabling or ammending the default policy. See the +udev documentation, e.g. man 7 udev, for details. If you're building from source, you need to copy the file to the place -where your distro expects such files. This is beyond the scope of this README, -but generally the location could be e.g. /etc/udev/rules.d, or maybe -/lib/udev/rules.d, or something else. Afterwards you might have to restart -udev, e.g. via '/etc/init.d/udev restart' or similar, and you'll have to -re-attach your device via USB. +where udev will read these rules. Local rules should go to /etc/udev/rules.d. +Keep the file naming, otherwise interaction between the libsigrok rules and +rules shipped by the system will be broken. -Please consult the udev docs of your distro for details. +Please consult the udev docs for details. Cypress FX2 based devices @@ -222,9 +293,11 @@ UNI-T DMM (and rebranded models) cables UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can ship with different PC connectivity cables: + - UT-D02 (RS232 cable) - UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490) - UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008) - - UT-D02 (RS232 cable) + - UT-D07 (Bluetooth adapter, ISSC BL79 BLETR chip) + - UT-D09 (USB/HID cable with SiL CP2110 chip, USB VID/PID 10c4:ea80) The above cables are all physically compatible (same IR connector shape) with all/most currently known UNI-T multimeters. For example, you can @@ -299,7 +372,12 @@ a short list for convenience: - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the interface panel on top. + - Brymen BM257s: Press HOLD during power-on. - Digitek DT4000ZC: Briefly press the "RS232" button. + - EEVBlog 121GW: Hold "1ms PEAK" until the "BT" indicator is shown. + - ES51919 based LCR meters (DER EE DE-5000, PeakTech 2170, UNI-T UT612): + Press the button with the "RS232" or "USB" or "PC link" label (usually + the "up" cursor button). - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232: - Power on the device with the "DATA" button pressed. - Metrahit 2x devices must be configured for the respective interface type. @@ -311,6 +389,10 @@ a short list for convenience: 'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must be configured to the same baud rate as the host (default 9600). Multimeter and interface must be configured to the same address. + - MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds. + - Metrix MX56C: Press the PRINT button to have the meter send acquisition + data via IR. Hold the PRINT button to adjust the meter's transmission + interval. - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power on the device with "FUNC" pressed (to power the interface from the DMM). - PCE PCE-DM32: Briefly press the "RS232" button. @@ -369,3 +451,74 @@ Example: $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ... + +Mooshimeter +----------- + +The Mooshim Engineering Mooshimeter is controlled via Bluetooth Low Energy +(sometimes called Bluetooth 4.0), as such it requires a supported Bluetooth +interface available. The 'conn' option is required and must contain the +Bluetooth MAC address of the meter. + +Example: + + $ sigrok-cli --driver mooshimeter-dmm:conn=12-34-56-78-9A-BC ... + +Since the Mooshimeter has no physical interface on the meter itself, the +channel configuration is set with the 'channel_config' option. The format +of this option is 'CH1,CH2' where each channel configuration has the form +'MODE:RANGE:ANALYSIS', with later parts being optional. In addition for +CLI compatibility, the ',' in the channels can also be a '/' and the ':' in +the individual configuration can be a ';'. + +Available channel 1 modes: + + - Current, A: Current in amps + - Temperature, T, K: Internal meter temperature in Kelvin + - Resistance, Ohm, W: Resistance in ohms + - Diode, D: Diode voltage + - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max) + +Available channel 2 modes: + + - Voltage, V: Voltage + - Temperature, T, K: Internal meter temperature in Kelvin + - Resistance, Ohm, W: Resistance in ohms + - Diode, D: Diode voltage + - Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max) + +Only one channel can use the shared inputs at a time (e.g. if CH1 is measuring +resistance, CH2 cannot measure low voltage). Temperature is excepted from +this, so the meter can measure internal temperature and low voltage at the +same time. + +Additionally, the meter can calculate the real power of both channels. This +generally only makes sense when CH1 is set to current and CH2 is set to a +voltage and so it is disabled by default. It must be enabled by enabling the +'P' channel (the third channel). + +The range of the channel specification sets the maximum input for that channel +and is rounded up to the next value the meter itself supports. For example, +specifying 50 for the voltage will result in the actual maximum of 60. +Specifying 61 would result in 600. If omitted, sigrok will perform +auto-ranging of the channel by selecting the next greater value than the +latest maximum. + +The analysis option sets how the meter reports its internal sampling buffer +to sigrok: + + - Mean, DC: The default is a simple arithmetic mean of the sample buffer + - RMS, AC: The root mean square of the sample buffer + - Buf, Buffer, Samples: Report the entire sample buffer to sigrok. This + results in packets that contain all the samples in the buffer instead + of a single output value. + +The size of the sample buffer is set with the 'avg_samples' option, while +the sampling rate is set with the 'samplerate' option. So the update rate +is avg_samples/samplerate. Both are rounded up to the next supported value +by the meter. + +Example: + + $ sigrok-cli -c channel_config="Aux;0.1/T" --driver mooshimeter-dmm... + $ sigrok-cli -c channel_config="A;;AC/V;;AC" --driver mooshimeter-dmm...