X-Git-Url: https://sigrok.org/gitweb/?a=blobdiff_plain;ds=sidebyside;f=src%2Fhardware%2Fikalogic-scanaplus%2Fapi.c;h=79585f060dfc86f9d71209cd27f2567611bd7f82;hb=f1ba6b4b2c9a8ecf90bb31efb218752aa7e49d1a;hp=ba4652ec060d83f698ff1102312aa8c510e7e3d1;hpb=6ec6c43b4738dbc7091f4a49a4ec80ea6102cb52;p=libsigrok.git
diff --git a/src/hardware/ikalogic-scanaplus/api.c b/src/hardware/ikalogic-scanaplus/api.c
index ba4652ec..79585f06 100644
--- a/src/hardware/ikalogic-scanaplus/api.c
+++ b/src/hardware/ikalogic-scanaplus/api.c
@@ -14,8 +14,7 @@
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
- * along with this program; if not, write to the Free Software
- * Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA
+ * along with this program; if not, see .
*/
#include
@@ -44,10 +43,6 @@ static const char *channel_names[] = {
/* Note: The IKALOGIC ScanaPLUS always samples at 100MHz. */
static const uint64_t samplerates[1] = { SR_MHZ(100) };
-SR_PRIV struct sr_dev_driver ikalogic_scanaplus_driver_info;
-
-static int dev_acquisition_stop(struct sr_dev_inst *sdi, void *cb_data);
-
static void clear_helper(void *priv)
{
struct dev_context *devc;
@@ -65,26 +60,15 @@ static int dev_clear(const struct sr_dev_driver *di)
return std_dev_clear(di, clear_helper);
}
-static int init(struct sr_dev_driver *di, struct sr_context *sr_ctx)
-{
- return std_init(sr_ctx, di, LOG_PREFIX);
-}
-
static GSList *scan(struct sr_dev_driver *di, GSList *options)
{
struct sr_dev_inst *sdi;
- struct drv_context *drvc;
struct dev_context *devc;
- GSList *devices;
unsigned int i;
int ret;
(void)options;
- drvc = di->context;
-
- devices = NULL;
-
/* Allocate memory for our private device context. */
devc = g_malloc0(sizeof(struct dev_context));
@@ -119,22 +103,18 @@ static GSList *scan(struct sr_dev_driver *di, GSList *options)
/* Register the device with libsigrok. */
sdi = g_malloc0(sizeof(struct sr_dev_inst));
- sdi->status = SR_ST_INITIALIZING;
+ sdi->status = SR_ST_INACTIVE;
sdi->vendor = g_strdup(USB_VENDOR_NAME);
sdi->model = g_strdup(USB_MODEL_NAME);
- sdi->driver = di;
sdi->priv = devc;
for (i = 0; i < ARRAY_SIZE(channel_names); i++)
sr_channel_new(sdi, i, SR_CHANNEL_LOGIC, TRUE, channel_names[i]);
- devices = g_slist_append(devices, sdi);
- drvc->instances = g_slist_append(drvc->instances, sdi);
-
/* Close device. We'll reopen it again when we need it. */
scanaplus_close(devc);
- return devices;
+ return std_scan_complete(di, g_slist_append(NULL, sdi));
scanaplus_close(devc);
err_free_ftdic:
@@ -149,11 +129,6 @@ err_free_devc:
return NULL;
}
-static GSList *dev_list(const struct sr_dev_driver *di)
-{
- return ((struct drv_context *)(di->context))->instances;
-}
-
static int dev_open(struct sr_dev_inst *sdi)
{
struct dev_context *devc;
@@ -232,38 +207,21 @@ static int dev_open(struct sr_dev_inst *sdi)
sr_dbg("Received ScanaPLUS device ID successfully: %02x %02x %02x.",
devc->devid[0], devc->devid[1], devc->devid[2]);
- sdi->status = SR_ST_ACTIVE;
-
return SR_OK;
err_dev_open_close_ftdic:
scanaplus_close(devc);
+
return SR_ERR;
}
static int dev_close(struct sr_dev_inst *sdi)
{
- int ret;
struct dev_context *devc;
- ret = SR_OK;
devc = sdi->priv;
- if (sdi->status == SR_ST_ACTIVE) {
- sr_dbg("Status ACTIVE, closing device.");
- ret = scanaplus_close(devc);
- } else {
- sr_spew("Status not ACTIVE, nothing to do.");
- }
-
- sdi->status = SR_ST_INACTIVE;
-
- return ret;
-}
-
-static int cleanup(const struct sr_dev_driver *di)
-{
- return dev_clear(di);
+ return scanaplus_close(devc);
}
static int config_get(uint32_t key, GVariant **data, const struct sr_dev_inst *sdi,
@@ -291,9 +249,6 @@ static int config_set(uint32_t key, GVariant *data, const struct sr_dev_inst *sd
(void)cg;
- if (sdi->status != SR_ST_ACTIVE)
- return SR_ERR_DEV_CLOSED;
-
devc = sdi->priv;
switch (key) {
@@ -350,24 +305,18 @@ static int config_list(uint32_t key, GVariant **data, const struct sr_dev_inst *
return SR_OK;
}
-static int dev_acquisition_start(const struct sr_dev_inst *sdi, void *cb_data)
+static int dev_acquisition_start(const struct sr_dev_inst *sdi)
{
int ret;
struct dev_context *devc;
- if (sdi->status != SR_ST_ACTIVE)
- return SR_ERR_DEV_CLOSED;
-
- if (!(devc = sdi->priv))
- return SR_ERR_BUG;
+ devc = sdi->priv;
if (!devc->ftdic)
return SR_ERR_BUG;
/* TODO: Configure channels later (thresholds etc.). */
- devc->cb_data = cb_data;
-
/* Properly reset internal variables before every new acquisition. */
devc->compressed_bytes_ignored = 0;
devc->samples_sent = 0;
@@ -379,8 +328,7 @@ static int dev_acquisition_start(const struct sr_dev_inst *sdi, void *cb_data)
if ((ret = scanaplus_start_acquisition(devc)) < 0)
return ret;
- /* Send header packet to the session bus. */
- std_session_send_df_header(sdi, LOG_PREFIX);
+ std_session_send_df_header(sdi);
/* Hook up a dummy handler to receive data from the device. */
sr_session_source_add(sdi->session, -1, 0, 0, scanaplus_receive_data, (void *)sdi);
@@ -388,31 +336,22 @@ static int dev_acquisition_start(const struct sr_dev_inst *sdi, void *cb_data)
return SR_OK;
}
-static int dev_acquisition_stop(struct sr_dev_inst *sdi, void *cb_data)
+static int dev_acquisition_stop(struct sr_dev_inst *sdi)
{
- struct sr_datafeed_packet packet;
-
- (void)cb_data;
-
- sr_dbg("Stopping acquisition.");
sr_session_source_remove(sdi->session, -1);
-
- /* Send end packet to the session bus. */
- sr_dbg("Sending SR_DF_END.");
- packet.type = SR_DF_END;
- sr_session_send(sdi, &packet);
+ std_session_send_df_end(sdi);
return SR_OK;
}
-SR_PRIV struct sr_dev_driver ikalogic_scanaplus_driver_info = {
+static struct sr_dev_driver ikalogic_scanaplus_driver_info = {
.name = "ikalogic-scanaplus",
.longname = "IKALOGIC ScanaPLUS",
.api_version = 1,
- .init = init,
- .cleanup = cleanup,
+ .init = std_init,
+ .cleanup = std_cleanup,
.scan = scan,
- .dev_list = dev_list,
+ .dev_list = std_dev_list,
.dev_clear = dev_clear,
.config_get = config_get,
.config_set = config_set,
@@ -423,3 +362,4 @@ SR_PRIV struct sr_dev_driver ikalogic_scanaplus_driver_info = {
.dev_acquisition_stop = dev_acquisition_stop,
.context = NULL,
};
+SR_REGISTER_DEV_DRIVER(ikalogic_scanaplus_driver_info);