X-Git-Url: https://sigrok.org/gitweb/?a=blobdiff_plain;ds=sidebyside;f=misc%2Fsquare_wave_2ch%2FREADME;fp=misc%2Fsquare_wave_2ch%2FREADME;h=0fbd17132c95508b2fc5839c3b20a48c5dc522bc;hb=3b25efe5be898dcb4d27ee4f2cb53b4a49ef56ea;hp=0000000000000000000000000000000000000000;hpb=1cd115bfa6b37e5172dfc3687ea9b70b38430c05;p=sigrok-dumps.git diff --git a/misc/square_wave_2ch/README b/misc/square_wave_2ch/README new file mode 100644 index 0000000..0fbd171 --- /dev/null +++ b/misc/square_wave_2ch/README @@ -0,0 +1,83 @@ +------------------------------------------------------------------------------- +Agilent MSO7034A +------------------------------------------------------------------------------- + +This is a set of files saved/exported from the Agilent MSO7034A oscilloscope. + +Details: +http://www.keysight.com/en/pd-1293631-pn-MSO7034A/mixed-signal-oscilloscope-350-mhz-4-analog-plus-16-digital-channels + + +Setup +----- + +The oscilloscope has the following options in the 'Save/Recall' menu, that +can be used to save the acquired/displayed data on a USB thumb drive: + + - Trace and Setup + - Used to store the data *in* the scope (not on USB thumb drive) + - BMP (8-bit) image file + - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale + - BMP (24-bit) image file + - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale + - PNG (24-bit) image file + - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale + - CSV data file + - Options: Setup info = y/n, Length = 100/250/500/1000 + - ASCII XY data file + - Options: Setup info = y/n, Length = x + (x = 100/250/500/1000/2000/5000/10000/20000/50000/100000/200000/500000 + 1000000/2000000) + - ALB data file + - Options: Setup info = y/n, Length = x (see above), + Alb serial format = Default/CAN/I2C/LIN/UART|RS232/SPI2/SPI3/SPI4 + - BIN data file + - Options: Setup info = y/n, Length = x (see above) + - Lister data file + - No options + +When "Setup info" is enabled, the scope also saves an additional file +with the respective basename and a *.txt extention (e.g. "scope_0.txt"), +which contains some ASCII info about the scope setup, any measurements +displayed on the LCD, and so on. + + +Files +----- + +Channels 1 and 2 of the (4-channel) scope were connected to the test output +of the scope (used for probe impedance matching), which outputs a 1.2kHz +square wave signal with an amplitude of 2.5V (2.72V peak-to-peak). + +After the "Stop" button was pressed, the following files were saved: + + scope_0: BMP (8-bit) + scope_1: BMP (24-bit) + scope_2: PNG (24-bit) + scope_3: CSV, 1000 + scope_4: CSV, 500 + scope_5: CSV, 250 + scope_6: CSV, 100 + scope_7: ASCII XY, 100 + scope_8: ASCII XY, 250 + ... + scope_19: ASCII XY, 1000000 + scope_20: ASCII XY, 2000000 + scope_21: ALB, 100, Default + scope_22: ALB, 100, CAN + scope_23: ALB, 100, I2C + scope_24: ALB, 100, LIN + scope_25: ALB, 100, UART/RS232 + scope_26: ALB, 100, SPI2 (SPI3/4 cannot be be used with only 2 channels) + scope_27: BIN, 100 + scope_28: BIN, 250 + scope_29: BIN, 500 + scope_30: Lister + +Only two "Setup info" files are included, scope_0.txt and scope_4.txt. +The first one is valid (and identical) for files scope_0* to scope_3*, the +latter is valid (and identical) for the files scope_4* to scope_30*. + +The *.bin files contain the device's serial number. This has been changed +(via hex editor) to "MY12345678" in the files. +