This directory contains waveforms generated with OWFS Tools: - Logic Analyzer: Tektronix TLA 613 - Sowtware: - Ubuntu 12.04 (Precise Pangolin) - owfs 2.8p15 - 1-Wire master: home made from: - PL2303 (USB to UART) - DS2480B (UART to 1-Wire) 1-Wire MicroLan: Two thermometers were attached to the bus (only the data line was connected, power was not): - DS28EA00 (1-Wire Digital Thermometer with Sequence Detect and PIO) - DS18B20 (Programmable Resolution 1-Wire Digital Thermometer) The server was started as: $ owserver -d /dev/ttyUSB0 Three dumps were created: 1) "owdir.sr" (samplerate = 1MHz) A request to list devices connected to the bus was performed: $ owdir /28.9BCFC8000000 /42.A8A603000000 /bus.0 /uncached /settings /system /statistics /structure /simultaneous /alarm 2) "DS18B20.sr" (samplerate = 1MHz) A read temperathure request was performed for the specified device: $ owread /28.9BCFC8000000/temperature 25.5 2) "DS28EA00.sr" (samplerate = 1MHz) A read temperathure request was performed for the specified device: $ owread /42.A8A603000000/temperature 26.875 Conversion from TXT to sigrok dumps: The provided dumps were exported from Flextronix TLA 613 logic analizer as text files. A simple Python script was used to convert this dumps first into a binary file and then into a sigrok standard dump. Decoding 1-Wire dumps sigrok-cli -i owdir.sr -a onewire:owr=0 sigrok-cli -i DS18B20.sr -a onewire:owr=0 sigrok-cli -i DS28EA00.sr -a onewire:owr=0