From: Uwe Hermann Date: Tue, 10 Jan 2012 20:47:08 +0000 (+0100) Subject: READMEs: Drop GND from probelist, useless. X-Git-Tag: sigrok-dumps-0.1.0~33 X-Git-Url: https://sigrok.org/gitaction?a=commitdiff_plain;h=f793c6d26e576d436b93b3414a00b9d2fcdcdaba;p=libsigrokdecode.git READMEs: Drop GND from probelist, useless. --- diff --git a/dcf77/pollin_dcf1_module/README b/dcf77/pollin_dcf1_module/README index ef8977d..b6fce07 100644 --- a/dcf77/pollin_dcf1_module/README +++ b/dcf77/pollin_dcf1_module/README @@ -27,7 +27,6 @@ The logic analyzer probes were connected like this: ------------------------ 1 (black) PON 2 (brown) DATA - GND GND Data diff --git a/i2c/a2_dummy_write/README b/i2c/a2_dummy_write/README index d7fe4e7..73e9b88 100644 --- a/i2c/a2_dummy_write/README +++ b/i2c/a2_dummy_write/README @@ -17,7 +17,6 @@ of 1MHz. The logic analyzer probes were connected to the I2C pins like this: ------------------------ 0 (green) SCL 1 (orange) SDA - GND GND Data diff --git a/i2c/rtc_epson_8564je/README b/i2c/rtc_epson_8564je/README index a6594f8..decf739 100644 --- a/i2c/rtc_epson_8564je/README +++ b/i2c/rtc_epson_8564je/README @@ -16,7 +16,6 @@ of 1MHz. The logic analyzer probes were connected to the RTC chip like this: ------------------------ 0 (green) SCL 1 (orange) SDA - GND GND Data diff --git a/spi/mx25l1605d/README b/spi/mx25l1605d/README index 784811c..83a987f 100644 --- a/spi/mx25l1605d/README +++ b/spi/mx25l1605d/README @@ -31,7 +31,6 @@ The ChronoVu LA8 probes were connected to the MX25L1605D chip like this: 3 (red) SI/SIO0 (a.k.a MOSI) 4 (gray) WP#/ACC 5 (brown) HOLD# - GND GND Probing diff --git a/uart/hello_world/README b/uart/hello_world/README index 03d2652..5bd2f89 100644 --- a/uart/hello_world/README +++ b/uart/hello_world/README @@ -28,7 +28,6 @@ The ChronoVu LA8 probes were connected to the UART like this: Probe UART ------------------- 0 (green) TX - GND GND Data diff --git a/uart/panasonic_pan1321/README b/uart/panasonic_pan1321/README index 9338ee8..240a647 100644 --- a/uart/panasonic_pan1321/README +++ b/uart/panasonic_pan1321/README @@ -25,7 +25,6 @@ The logic analyzer probes were connected like this: ------------------- 0 (green) TX 1 (orange) RX - GND GND Successful initialization diff --git a/uart/trekstor_ebr30_a/README b/uart/trekstor_ebr30_a/README index c77de4c..d953b46 100644 --- a/uart/trekstor_ebr30_a/README +++ b/uart/trekstor_ebr30_a/README @@ -23,7 +23,6 @@ The ChronoVu LA8 probes were connected to the EBR30-a device like this: Probe EBR30-a ------------------- 1 (orange) TX - GND GND Data