From: Gerhard Sittig Date: Sun, 3 Apr 2022 18:09:18 +0000 (+0200) Subject: README.devices: add an UT-D04 on Windows section (libwdi and hidapi) X-Git-Url: https://sigrok.org/gitaction?a=commitdiff_plain;h=c1f32601c47daec77012fd761611c503bf4cd104;p=libsigrok.git README.devices: add an UT-D04 on Windows section (libwdi and hidapi) A user reported that the Windows driver which is assigned to the CH9325 based UT-D04 cable neither provides a genuine serial port nor shows up in the sigrok enumeration which additionally uses HIDAPI. Mention that assigning a different Windows driver can help in that case. --- diff --git a/README.devices b/README.devices index e527f054..d2f4db8c 100644 --- a/README.devices +++ b/README.devices @@ -403,6 +403,18 @@ See also: http://erste.de/UT61/index.html done +UNI-T UT-D04 cable issue on Windows +----------------------------------- + +There have been reports that CH9325 based cables are not detected on +Windows out of the box when they are assigned to libwdi drivers. Though +they may be usable in that case when the USB address is manually specified. +This can happen when some "USB to serial" driver is assigned which does not +provide a genuine COM port that enumerates naturally. Manually assigning a +"USB input device" driver can improve HIDAPI compatibility and make the +cable show up in sigrok's serial port enumeration. + + Enabling multimeter / data logger measurement output ----------------------------------------------------