]> sigrok.org Git - sigrok-dumps.git/commitdiff
rc-6: initial commit of 3 RC-6 dumps
authorBenediktO <redacted>
Sun, 1 Dec 2019 11:53:04 +0000 (12:53 +0100)
committerUwe Hermann <redacted>
Tue, 3 Dec 2019 20:48:56 +0000 (21:48 +0100)
ir/rc-6/kathrein/README [new file with mode: 0644]
ir/rc-6/kathrein/kathrein_rc674_numbers.sr [new file with mode: 0644]
ir/rc-6/philips/README [new file with mode: 0644]
ir/rc-6/philips/philips_rc2143604_numbers.sr [new file with mode: 0644]
ir/rc-6/philips/philips_unknown_numbers.sr [new file with mode: 0644]

diff --git a/ir/rc-6/kathrein/README b/ir/rc-6/kathrein/README
new file mode 100644 (file)
index 0000000..6b50fe6
--- /dev/null
@@ -0,0 +1,30 @@
+-------------------------------------------------------------------------------
+Philips RC-6 remote control captures
+-------------------------------------------------------------------------------
+
+These captures contain the IR data sent by various remote controls.
+
+
+Logic analyzer setup
+--------------------
+
+The logic analyzer used was a Saleae Logic (at 1MHz):
+
+  Probe       RC-6
+  ----------------
+  0           IR
+  1           Raw
+
+The data was captured using a TSOP1736 directly connected to channel 0.
+For comparison a phototransistor is connected to channel 1. Only channel 0
+should be used for decoding.
+
+
+kathrein_RC674_numbers.sr
+-------------------------
+
+This capture was taken with a Kathrein RC(U)674 remote control. The
+sequence of keys is "power", 1, 2, ..., 9, 0.
+
+Note that this remote uses Mode 6B and does not make use of the 
+integrated toggle bit, but uses the first data bit for that purpose.
diff --git a/ir/rc-6/kathrein/kathrein_rc674_numbers.sr b/ir/rc-6/kathrein/kathrein_rc674_numbers.sr
new file mode 100644 (file)
index 0000000..7dcdb9b
Binary files /dev/null and b/ir/rc-6/kathrein/kathrein_rc674_numbers.sr differ
diff --git a/ir/rc-6/philips/README b/ir/rc-6/philips/README
new file mode 100644 (file)
index 0000000..3d85749
--- /dev/null
@@ -0,0 +1,37 @@
+-------------------------------------------------------------------------------
+Philips RC-6 remote control captures
+-------------------------------------------------------------------------------
+
+These captures contain the IR data sent by various remote controls.
+
+Logic analyzer setup
+--------------------
+
+The logic analyzer used was a Saleae Logic (at 1MHz):
+
+  Probe       RC-6
+  ----------------
+  0           IR
+  1           Raw
+
+The data was captured using a TSOP1736 directly connected to channel 0.
+For comparison a phototransistor is connected to channel 1. Only channel 0
+should be used for decoding.
+
+
+philips_RC2143604_numbers.sr
+----------------------------
+
+This capture was taken with a Philips RC2143604 remote control. The
+sequence of keys is "power", 1, 2, ..., 9, 0.
+
+Note that this remote uses Mode 0.
+
+
+philips_unknown_numbers.sr
+--------------------------
+
+This capture was taken with an unknown Philips remote control. The
+sequence of keys is "power", 1, 2, ..., 9.
+
+Note that this remote uses Mode 0.
diff --git a/ir/rc-6/philips/philips_rc2143604_numbers.sr b/ir/rc-6/philips/philips_rc2143604_numbers.sr
new file mode 100644 (file)
index 0000000..6e3efaa
Binary files /dev/null and b/ir/rc-6/philips/philips_rc2143604_numbers.sr differ
diff --git a/ir/rc-6/philips/philips_unknown_numbers.sr b/ir/rc-6/philips/philips_unknown_numbers.sr
new file mode 100644 (file)
index 0000000..d793eb8
Binary files /dev/null and b/ir/rc-6/philips/philips_unknown_numbers.sr differ