--- /dev/null
+/*
+ * This file is part of the sigrok project.
+ *
+ * Copyright (C) 2012 Bert Vermeulen <bert@biot.com>
+ *
+ * This program is free software: you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License as published by
+ * the Free Software Foundation, either version 3 of the License, or
+ * (at your option) any later version.
+ *
+ * This program is distributed in the hope that it will be useful,
+ * but WITHOUT ANY WARRANTY; without even the implied warranty of
+ * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
+ * GNU General Public License for more details.
+ *
+ * You should have received a copy of the GNU General Public License
+ * along with this program. If not, see <http://www.gnu.org/licenses/>.
+ */
+
+#include <glib.h>
+#include "libsigrok.h"
+#include "libsigrok-internal.h"
+#include "config.h"
+#include "fluke-dmm.h"
+#include <stdlib.h>
+#include <math.h>
+#include <string.h>
+#include <errno.h>
+
+
+static struct sr_datafeed_analog *handle_qm_v2(const struct sr_dev_inst *sdi,
+ char **tokens)
+{
+ struct sr_datafeed_analog *analog;
+ float fvalue;
+ char *eptr;
+
+ (void)sdi;
+ fvalue = strtof(tokens[0], &eptr);
+ if (fvalue == 0.0 && eptr == tokens[0]) {
+ sr_err("fluke-dmm: invalid float");
+ return NULL;
+ }
+
+ analog = g_try_malloc0(sizeof(struct sr_datafeed_analog));
+ analog->num_samples = 1;
+ analog->data = g_try_malloc(sizeof(float));
+ *analog->data = fvalue;
+ analog->mq = -1;
+
+ if (!strcmp(tokens[1], "VAC") || !strcmp(tokens[1], "VDC")) {
+ analog->mq = SR_MQ_VOLTAGE;
+ analog->unit = SR_UNIT_VOLT;
+ if (!strcmp(tokens[2], "NORMAL")) {
+ if (tokens[1][1] == 'A') {
+ analog->mqflags |= SR_MQFLAG_AC;
+ analog->mqflags |= SR_MQFLAG_RMS;
+ } else
+ analog->mqflags |= SR_MQFLAG_DC;
+ } else if (!strcmp(tokens[2], "OL") || !strcmp(tokens[2], "OL_MINUS")) {
+ *analog->data = NAN;
+ } else
+ analog->mq = -1;
+ } if (!strcmp(tokens[1], "CEL") || !strcmp(tokens[1], "FAR")) {
+ if (!strcmp(tokens[2], "NORMAL")) {
+ analog->mq = SR_MQ_TEMPERATURE;
+ if (tokens[1][0] == 'C')
+ analog->unit = SR_UNIT_CELSIUS;
+ else
+ analog->unit = SR_UNIT_FAHRENHEIT;
+ }
+ } if (!strcmp(tokens[1], "OHM")) {
+ if (!strcmp(tokens[3], "NONE")) {
+ analog->mq = SR_MQ_RESISTANCE;
+ analog->unit = SR_UNIT_OHM;
+ if (!strcmp(tokens[2], "OL") || !strcmp(tokens[2], "OL_MINUS")) {
+ *analog->data = INFINITY;
+ } else if (strcmp(tokens[2], "NORMAL"))
+ analog->mq = -1;
+ } else if (!strcmp(tokens[3], "OPEN_CIRCUIT")) {
+ analog->mq = SR_MQ_CONTINUITY;
+ analog->unit = SR_UNIT_BOOLEAN;
+ *analog->data = 0.0;
+ } else if (!strcmp(tokens[3], "SHORT_CIRCUIT")) {
+ analog->mq = SR_MQ_CONTINUITY;
+ analog->unit = SR_UNIT_BOOLEAN;
+ *analog->data = 1.0;
+ }
+ } if (!strcmp(tokens[1], "F")
+ && !strcmp(tokens[2], "NORMAL")
+ && !strcmp(tokens[3], "NONE")) {
+ analog->mq = SR_MQ_CAPACITANCE;
+ analog->unit = SR_UNIT_FARAD;
+ } else if (!strcmp(tokens[1], "AAC") || !strcmp(tokens[1], "ADC")) {
+ analog->mq = SR_MQ_CURRENT;
+ analog->unit = SR_UNIT_AMPERE;
+ analog->mqflags = SR_MQFLAG_RMS;
+ if (!strcmp(tokens[2], "NORMAL")) {
+ if (tokens[1][1] == 'A') {
+ analog->mqflags |= SR_MQFLAG_AC;
+ analog->mqflags |= SR_MQFLAG_RMS;
+ } else
+ analog->mqflags |= SR_MQFLAG_DC;
+ } else if (!strcmp(tokens[2], "OL") || !strcmp(tokens[2], "OL_MINUS")) {
+ *analog->data = NAN;
+ } else
+ analog->mq = -1;
+ } if (!strcmp(tokens[1], "Hz") && !strcmp(tokens[2], "NORMAL")) {
+ analog->mq = SR_MQ_FREQUENCY;
+ analog->unit = SR_UNIT_HERTZ;
+ } if (!strcmp(tokens[1], "PCT") && !strcmp(tokens[2], "NORMAL")) {
+ analog->mq = SR_MQ_DUTY_CYCLE;
+ analog->unit = SR_UNIT_PERCENTAGE;
+ } if (!strcmp(tokens[1], "S") && !strcmp(tokens[2], "NORMAL")) {
+ analog->mq = SR_MQ_PULSE_WIDTH;
+ analog->unit = SR_UNIT_SECOND;
+ } if (!strcmp(tokens[1], "SIE") && !strcmp(tokens[2], "NORMAL")) {
+ analog->mq = SR_MQ_CONDUCTANCE;
+ analog->unit = SR_UNIT_SIEMENS;
+ }
+
+
+ if (analog->mq == -1) {
+ /* Not a valid measurement. */
+ g_free(analog->data);
+ g_free(analog);
+ analog = NULL;
+ }
+
+ return analog;
+}
+
+static void handle_line(const struct sr_dev_inst *sdi)
+{
+ struct dev_context *devc;
+ struct sr_datafeed_packet packet;
+ struct sr_datafeed_analog *analog;
+ char **tokens;
+
+ devc = sdi->priv;
+ sr_spew("fluke-dmm: received line '%s' (%d)", devc->buf, devc->buflen);
+
+ if (devc->buflen == 1) {
+ if (devc->buf[0] != '0') {
+ /* Not just a CMD_ACK from the query command. */
+ sr_dbg("fluke-dmm: got CMD_ACK '%c'", devc->buf[0]);
+ devc->expect_response = FALSE;
+ }
+ devc->buflen = 0;
+ return;
+ }
+
+ analog = NULL;
+ tokens = g_strsplit(devc->buf, ",", 0);
+ if (devc->profile->model == FLUKE_187) {
+ if (!strcmp(tokens[0], "QM")) {
+ /* Yes, this is the response to the query. */
+ devc->expect_response = FALSE;
+ sr_spew("187 line");
+ /* TODO */
+ devc->buflen = 0;
+ }
+ } else if (devc->profile->model == FLUKE_287) {
+ devc->expect_response = FALSE;
+ analog = handle_qm_v2(sdi, tokens);
+ }
+ g_strfreev(tokens);
+ devc->buflen = 0;
+
+ if (analog) {
+ /* Got a measurement. */
+ sr_dbg("val %f", *analog->data);
+ packet.type = SR_DF_ANALOG;
+ packet.payload = analog;
+ sr_session_send(devc->cb_data, &packet);
+ devc->num_samples++;
+ g_free(analog->data);
+ g_free(analog);
+ }
+
+}
+
+SR_PRIV int fluke_receive_data(int fd, int revents, void *cb_data)
+{
+ const struct sr_dev_inst *sdi;
+ struct dev_context *devc;
+ int len;
+ int64_t now, elapsed;
+
+ if (!(sdi = cb_data))
+ return TRUE;
+
+ if (!(devc = sdi->priv))
+ return TRUE;
+
+ if (revents == G_IO_IN) {
+ /* Serial data arrived. */
+ while(FLUKEDMM_BUFSIZE - devc->buflen - 1 > 0) {
+ len = serial_read(fd, devc->buf + devc->buflen, 1);
+ if (len < 1)
+ break;
+ devc->buflen++;
+ *(devc->buf + devc->buflen) = '\0';
+ if (*(devc->buf + devc->buflen - 1) == '\r') {
+ *(devc->buf + --devc->buflen) = '\0';
+ handle_line(sdi);
+ break;
+ }
+ }
+ }
+
+ if (devc->num_samples >= devc->limit_samples) {
+ sdi->driver->dev_acquisition_stop(sdi, cb_data);
+ return TRUE;
+ }
+
+ now = g_get_monotonic_time() / 1000;
+ elapsed = now - devc->cmd_sent_at;
+ /* Send query command at poll_period interval, or after 1 second
+ * has elapsed. This will make it recover from any out-of-sync
+ * or temporary disconnect issues. */
+ if ((devc->expect_response == FALSE && elapsed > devc->profile->poll_period)
+ || elapsed > 1000) {
+ sr_spew("fluke-dmm: sending QM");
+ if (serial_write(devc->serial->fd, "QM\r", 3) == -1)
+ sr_err("fluke-dmm: unable to send QM: %s", strerror(errno));
+ devc->cmd_sent_at = now;
+ devc->expect_response = TRUE;
+ }
+
+ return TRUE;
+}
+
+