ALL_ZERO,
};
+static const struct scpi_command cmdset_gwinstek[] = {
+ { DMM_CMD_SETUP_REMOTE, "SYST:REM", },
+ { DMM_CMD_SETUP_FUNC, "CONF:%s", },
+ { DMM_CMD_QUERY_FUNC, "CONF:STAT:FUNC?", },
+ { DMM_CMD_START_ACQ, "*CLS;SYST:REM", },
+ { DMM_CMD_STOP_ACQ, "SYST:LOC", },
+ { DMM_CMD_QUERY_VALUE, "VAL1?", },
+ { DMM_CMD_QUERY_PREC, "SENS:DET:RATE?", },
+ ALL_ZERO,
+};
+
static const struct mqopt_item mqopts_agilent_34405a[] = {
{ SR_MQ_VOLTAGE, SR_MQFLAG_DC, "VOLT:DC", "VOLT ", NO_DFLT_PREC, },
{ SR_MQ_VOLTAGE, SR_MQFLAG_AC, "VOLT:AC", "VOLT:AC ", NO_DFLT_PREC, },
{ SR_MQ_TIME, 0, "PER", "PER ", NO_DFLT_PREC, },
};
+static const struct mqopt_item mqopts_gwinstek_gdm8200a[] = {
+ { SR_MQ_VOLTAGE, SR_MQFLAG_DC, "VOLT:DC", "01", NO_DFLT_PREC, },
+ { SR_MQ_VOLTAGE, SR_MQFLAG_AC, "VOLT:AC", "02", NO_DFLT_PREC, },
+ { SR_MQ_CURRENT, SR_MQFLAG_DC, "CURR:DC", "03", NO_DFLT_PREC, },
+ { SR_MQ_CURRENT, SR_MQFLAG_AC, "CURR:AC", "04", NO_DFLT_PREC, },
+ { SR_MQ_CURRENT, SR_MQFLAG_DC, "CURR:DC", "05", NO_DFLT_PREC, }, /* mA */
+ { SR_MQ_CURRENT, SR_MQFLAG_AC, "CURR:AC", "06", NO_DFLT_PREC, }, /* mA */
+ { SR_MQ_RESISTANCE, 0, "RES", "07", NO_DFLT_PREC, },
+ { SR_MQ_RESISTANCE, SR_MQFLAG_FOUR_WIRE, "FRES", "16", NO_DFLT_PREC, },
+ { SR_MQ_CONTINUITY, 0, "CONT", "13", -1, },
+ { SR_MQ_VOLTAGE, SR_MQFLAG_DC | SR_MQFLAG_DIODE, "DIOD", "17", -4, },
+ { SR_MQ_TEMPERATURE, 0, "TEMP", "09", NO_DFLT_PREC, }, /* Celsius */
+ { SR_MQ_TEMPERATURE, 0, "TEMP", "15", NO_DFLT_PREC, }, /* Fahrenheit */
+ { SR_MQ_FREQUENCY, 0, "FREQ", "08", NO_DFLT_PREC, },
+ { SR_MQ_TIME, 0, "PER", "14", NO_DFLT_PREC, },
+};
+
SR_PRIV const struct scpi_dmm_model models[] = {
{
"Agilent", "34405A",
/* 34401A: typ. 1020ms for AC readings (default is 1000ms). */
1000 * 1500,
},
+ {
+ "GW", "GDM8251A",
+ 1, 6, cmdset_gwinstek, ARRAY_AND_SIZE(mqopts_gwinstek_gdm8200a),
+ scpi_dmm_get_meas_gwinstek,
+ ARRAY_AND_SIZE(devopts_generic),
+ 1000 * 2500,
+ },
+ {
+ "GW", "GDM8255A",
+ 1, 6, cmdset_gwinstek, ARRAY_AND_SIZE(mqopts_gwinstek_gdm8200a),
+ scpi_dmm_get_meas_gwinstek,
+ ARRAY_AND_SIZE(devopts_generic),
+ 1000 * 2500,
+ },
};
static const struct scpi_dmm_model *is_compatible(const char *vendor, const char *model)
devc->num_channels = model->num_channels;
devc->cmdset = model->cmdset;
devc->model = model;
+ devc->precision = NULL;
for (i = 0; i < devc->num_channels; i++) {
channel_name = g_strdup_printf("P%zu", i + 1);
int ret;
const struct mqopt_item *item;
const char *command;
+ char *response;
scpi = sdi->conn;
devc = sdi->priv;
if (ret != SR_OK)
return ret;
+ /*
+ * Query for current precision if DMM supports the command
+ */
+ command = sr_scpi_cmd_get(devc->cmdset, DMM_CMD_QUERY_PREC);
+ if (command && *command) {
+ scpi_dmm_cmd_delay(scpi);
+ ret = sr_scpi_get_string(scpi, command, &response);
+ if (ret == SR_OK) {
+ g_strstrip(response);
+ if (devc->precision)
+ g_free(devc->precision);
+ devc->precision=g_strdup(response);
+ g_free(response);
+ sr_dbg("%s: Precision: '%s'", __func__, devc->precision);
+ } else {
+ sr_info("%s: Precision query ('%s') failed: %d",
+ __func__, command, ret);
+ }
+ }
+
command = sr_scpi_cmd_get(devc->cmdset, DMM_CMD_START_ACQ);
if (command && *command) {
scpi_dmm_cmd_delay(scpi);
std_session_send_df_end(sdi);
+ if (devc->precision) {
+ g_free(devc->precision);
+ devc->precision = NULL;
+ }
+
return SR_OK;
}
return SR_OK;
}
+SR_PRIV int scpi_dmm_get_meas_gwinstek(const struct sr_dev_inst *sdi, size_t ch)
+{
+ struct sr_scpi_dev_inst *scpi;
+ struct dev_context *devc;
+ struct scpi_dmm_acq_info *info;
+ struct sr_datafeed_analog *analog;
+ int ret;
+ enum sr_mq mq;
+ enum sr_mqflag mqflag;
+ char *mode_response;
+ const char *p;
+ const struct mqopt_item *item;
+ const char *command;
+ char *response;
+ gboolean use_double;
+ int sig_digits, val_exp;
+ int digits;
+ enum sr_unit unit;
+ int mmode;
+
+ scpi = sdi->conn;
+ devc = sdi->priv;
+ info = &devc->run_acq_info;
+ analog = &info->analog[ch];
+
+ /*
+ * Get the meter's current mode, keep the response around.
+ * Skip the measurement if the mode is uncertain.
+ */
+ ret = scpi_dmm_get_mq(sdi, &mq, &mqflag, &mode_response, &item);
+ if (ret != SR_OK) {
+ g_free(mode_response);
+ return ret;
+ }
+ if (!mode_response)
+ return SR_ERR;
+ if (!mq) {
+ g_free(mode_response);
+ return +1;
+ }
+ mmode = atoi(mode_response);
+ g_free(mode_response);
+
+ /*
+ * Get the current reading from the meter.
+ */
+ scpi_dmm_cmd_delay(scpi);
+ command = sr_scpi_cmd_get(devc->cmdset, DMM_CMD_QUERY_VALUE);
+ if (!command || !*command)
+ return SR_ERR_NA;
+ scpi_dmm_cmd_delay(scpi);
+ ret = sr_scpi_get_string(scpi, command, &response);
+ if (ret != SR_OK)
+ return ret;
+ g_strstrip(response);
+ use_double = devc->model->digits > 6;
+ ret = sr_atod_ascii(response, &info->d_value);
+ if (ret != SR_OK) {
+ g_free(response);
+ return ret;
+ }
+ if (!response)
+ return SR_ERR;
+ if (info->d_value > +9e37) {
+ info->d_value = +INFINITY;
+ } else if (info->d_value < -9e37) {
+ info->d_value = -INFINITY;
+ } else {
+ p = response;
+ while (p && *p && g_ascii_isspace(*p))
+ p++;
+ if (p && *p && (*p == '-' || *p == '+'))
+ p++;
+ sig_digits = 0;
+ while (p && *p && g_ascii_isdigit(*p)) {
+ sig_digits++;
+ p++;
+ }
+ if (p && *p && *p == '.')
+ p++;
+ while (p && *p && g_ascii_isdigit(*p))
+ p++;
+ ret = SR_OK;
+ if (!p || !*p)
+ val_exp = 0;
+ else if (*p != 'e' && *p != 'E')
+ ret = SR_ERR_DATA;
+ else
+ ret = sr_atoi(++p, &val_exp);
+ }
+ g_free(response);
+ if (ret != SR_OK)
+ return ret;
+
+ /*
+ * Make sure we report "INFINITY" when meter displays "0L"
+ */
+ switch (mmode) {
+ case 7:
+ case 16:
+ /* in resitance modes 0L reads as 1.20000E8 or 1.99999E8 */
+ if (!strncmp(devc->model->model,"GDM8255A",8)) {
+ if (info->d_value >= 1.99999e8)
+ info->d_value = +INFINITY;
+ } else {
+ if (info->d_value >= 1.2e8)
+ info->d_value = +INFINITY;
+ }
+ break;
+ case 13:
+ /* In continuity mode 0L reads as 1.20000E3 */
+ if (info->d_value >= 1.2e3)
+ info->d_value = +INFINITY;
+ break;
+ case 17:
+ /* in diode mode 0L reads as 1.00000E0 */
+ if (info->d_value == 1.0e0)
+ info->d_value = +INFINITY;
+ break;
+ }
+
+ /*
+ * Calculate 'digits' based on the precision reading result
+ * done during start of acquisition.
+ *
+ * GW-Instek manual gives following info regarding resolution:
+ *
+ * Type Digit
+ * -------------------- ------------
+ * Slow 5 1/2
+ * Medium 4 1/2
+ * Fast 3 1/2
+ *
+ */
+
+ digits = devc->model->digits;
+ if (devc->precision && *devc->precision) {
+ if (!strncmp(devc->precision, "Slow", 4))
+ digits = 6;
+ else if (!strncmp(devc->precision, "Mid", 3))
+ digits = 5;
+ else if (!strncmp(devc->precision, "Fast", 4))
+ digits = 4;
+ else
+ sr_info("%s: Unknown precision: '%s'",
+ __func__, devc->precision);
+ }
+
+ /*
+ * Fill in the 'analog' description: value, encoding, meaning.
+ * Callers will fill in the sample count, and channel name,
+ * and will send out the packet.
+ */
+ if (use_double) {
+ analog->data = &info->d_value;
+ analog->encoding->unitsize = sizeof(info->d_value);
+ } else {
+ info->f_value = info->d_value;
+ analog->data = &info->f_value;
+ analog->encoding->unitsize = sizeof(info->f_value);
+ }
+ analog->encoding->is_float = TRUE;
+#ifdef WORDS_BIGENDIAN
+ analog->encoding->is_bigendian = TRUE;
+#else
+ analog->encoding->is_bigendian = FALSE;
+#endif
+ analog->encoding->digits = digits;
+ analog->meaning->mq = mq;
+ analog->meaning->mqflags = mqflag;
+ switch (mq) {
+ case SR_MQ_VOLTAGE:
+ unit = SR_UNIT_VOLT;
+ break;
+ case SR_MQ_CURRENT:
+ unit = SR_UNIT_AMPERE;
+ break;
+ case SR_MQ_RESISTANCE:
+ case SR_MQ_CONTINUITY:
+ unit = SR_UNIT_OHM;
+ break;
+ case SR_MQ_CAPACITANCE:
+ unit = SR_UNIT_FARAD;
+ break;
+ case SR_MQ_TEMPERATURE:
+ switch (mmode) {
+ case 15:
+ unit = SR_UNIT_FAHRENHEIT;
+ break;
+ case 9:
+ default:
+ unit = SR_UNIT_CELSIUS;
+ }
+ break;
+ case SR_MQ_FREQUENCY:
+ unit = SR_UNIT_HERTZ;
+ break;
+ case SR_MQ_TIME:
+ unit = SR_UNIT_SECOND;
+ break;
+ default:
+ return SR_ERR_NA;
+ }
+ analog->meaning->unit = unit;
+ analog->spec->spec_digits = digits;
+
+ return SR_OK;
+}
+
/* Strictly speaking this is a timer controlled poll routine. */
SR_PRIV int scpi_dmm_receive_data(int fd, int revents, void *cb_data)
{