The listing of the following configuration options is currently
broken in sigrok-cli (invalid values are displayed):
- "timebase" in yokogawa-dlm, rohde-schwarz-hameg, hantek-dso,
lecroy-xstream, siglent-sds and rigol-ds drivers;
- "vdiv" in hantek-6xxx, yokogawa-dlm, rohde-schwarz-hameg, hantek-dso,
lecroy-xstream, hung-chang-dso-2100, siglent-sds and rigol-ds drivers;
- "spl_meas_range" in pce-322a and cem-dt-885x drivers.
Fixes bug #1331.
Signed-off-by: Guido Trentalancia <redacted>
GVariant *gvar_dict, *gvar_list, *gvar;
gsize num_elements;
double dlow, dhigh, dcur_low, dcur_high;
- const uint64_t *uint64, p = 0, q = 0, low = 0, high = 0;
+ const uint64_t *uint64;
+ uint64_t p = 0, q = 0, low = 0, high = 0;
uint64_t tmp_uint64, mask, cur_low, cur_high, cur_p, cur_q;
GArray *opts;
const int32_t *int32;