With trigger enabled, and with PulseView, a second (or more) acquisition
starts immediately instead of blocking. It's mandatory to try several times
to have a correct behavior.
According to http://mygizmos.org/ols/Logic-Sniffer-FPGA-Spec.pdf section 2.3.1
p.8, the Openbench Logic Sniffer must be reset before each arm command.
This fixes bug #809.
Signed-off-by: Gwenhael Goavec-Merou <redacted>
return SR_ERR;
}
if (devc->num_stages > 0) {
+ /*
+ * According to http://mygizmos.org/ols/Logic-Sniffer-FPGA-Spec.pdf
+ * reset command must be send prior each arm command
+ */
+ sr_dbg("Send reset command before trigger configure");
+ if (ols_send_reset(serial) != SR_OK)
+ return SR_ERR;
+
delaycount = readcount * (1 - devc->capture_ratio / 100.0);
devc->trigger_at = (readcount - delaycount) * 4 - devc->num_stages;
for (i = 0; i <= devc->num_stages; i++) {