Capture does not stop for sample count values which exceed the range of
a 32bit type variable. Adjust the data type to 64bit.
How to reproduce: 8MSa/s * 600s -> 4,800,000,000 samples
$ sigrok-cli -d fx2lafw -o capture.sr --config samplerate=8M --time 600000
[ gsi: rephrased the commit message ]
struct soft_trigger_logic *stl;
uint64_t num_frames;
- unsigned int sent_samples;
+ uint64_t sent_samples;
int submitted_transfers;
int empty_transfer_count;