]> sigrok.org Git - libsigrok.git/commit
arachnid-labs-re-load-pro: Change serial read in acquisition mode.
authorFrank Stettner <redacted>
Sat, 11 Nov 2017 17:29:19 +0000 (18:29 +0100)
committerUwe Hermann <redacted>
Sat, 3 Mar 2018 18:10:51 +0000 (19:10 +0100)
commita2172899517ab756ca765913d9957fc1f98e892b
treed35c77bbdb404e49e4c96d1aeaf4d1fd3d9b47ff
parent4389a54204729b60c003814e7e91756b5c6ea454
arachnid-labs-re-load-pro: Change serial read in acquisition mode.

Use serial_readline in acquisition mode, otherwise data from the
Re:load Pro could get lost.
Use reloadpro_receive_data() for all commands when in acquisition
mode. When not using a single point of receiving data, data could get
lost.
src/hardware/arachnid-labs-re-load-pro/api.c
src/hardware/arachnid-labs-re-load-pro/protocol.c
src/hardware/arachnid-labs-re-load-pro/protocol.h