asix-sigma: discuss usability of data pattern trigger specs
authorGerhard Sittig <redacted>
Sun, 31 May 2020 10:38:21 +0000 (12:38 +0200)
committerGerhard Sittig <redacted>
Sun, 31 May 2020 21:56:40 +0000 (23:56 +0200)
commit5cc292b34aa5a4c2818b0db668f2b61702b994b9
tree7ec651b0e40fe4a6d9dc5ab54311dcdd81f964d9
parente09267136518776a5afc42049d1953360f2d3966
asix-sigma: discuss usability of data pattern trigger specs

When data patterns for trigger specs span multiple bits, users may not
want to specify long lists of "<ch>=<lvl>" conditions for sigrok-cli's
--trigger option, and count channels by hand. Or click a dozen dialogs
to specify one data pattern, or modify a previous specification. Setups
with few traces may accept that, "data heavy" setups like parallel data
or address bus inspection may not.

Add comments which discuss the potential use of SR_CONF_TRIGGER_PATTERN.
Outline a syntax which may be flexible enough _and_ acceptable to users,
support data patterns and edge triggers alike, in several presentations
that serve different use cases.  This commit exclusively adds comments,
does not change behaviour.

Update a comment in the user spec to internal format trigger spec parser
to expand on hardware constraints and implementation limitations. Rename
an identifier which checks the number of edge conditions, not the number
of accepted trigger spec details.
src/hardware/asix-sigma/api.c
src/hardware/asix-sigma/protocol.c