Summary: | Russ reports that Zero Plus triggering is broken since 8dd441909 | ||
---|---|---|---|
Product: | PulseView | Reporter: | Joel Holdsworth <joel> |
Component: | Acquisition | Assignee: | Nobody <nobody> |
Status: | RESOLVED FIXED | ||
Severity: | normal | CC: | daniel.kitta |
Priority: | Normal | ||
Version: | unreleased development snapshot | ||
Target Milestone: | PulseView 0.2.0 | ||
Hardware: | All | ||
OS: | All |
Description
Joel Holdsworth
2014-02-13 10:06:09 CET
Looks like it. No per-channel triggers anymore with my LWLA1034. Turns out to be a trivial mistake. Here's the fix: https://github.com/danielkitta/pulseview/commits/bug318-broken-triggers Fixed in ab4e1fcb5fc453c811d25038f872f3326f8f846e |